The aim of this study was to assess the role
of synovial C-reactive protein (CRP) in the diagnosis of chronic periprosthetic
hip infection. We prospectively collected synovial fluid from 89
patients undergoing revision hip arthroplasty and measured synovial
CRP, serum CRP, erythrocyte sedimentation rate (ESR), synovial white
blood cell (WBC) count and synovial percentages of polymorphonuclear
neutrophils (PMN). Patients were classified as septic or aseptic
by means of clinical, microbiological, serum and synovial fluid
findings. The high viscosity of the synovial fluid precluded the
analyses in nine patients permitting the results in 80 patients
to be studied. There was a significant difference in synovial CRP
levels between the septic (n = 21) and the aseptic (n = 59) cohort.
According to the receiver operating characteristic curve, a synovial
CRP threshold of 2.5 mg/l had a sensitivity of 95.5% and specificity
of 93.3%. The area under the curve was 0.96. Compared with serum
CRP and ESR, synovial CRP showed a high diagnostic value. According
to these preliminary results, synovial CRP may be a useful parameter
in diagnosing chronic periprosthetic hip infection. Cite this article:
The February 2015 Children’s orthopaedics Roundup360 looks at: Hip dislocation in children with CTEV: two decades of experience; Population-based prevention of DDH in cerebral palsy: 20 years’ experience; Shoulder derotation in congenital plexus palsy; Back pain in the paediatric population: could MRI be the answer?; Intercondylar fracture of the humerus in children; The Dunn osteotomy in SUFE; Radiocapitellar line a myth!; Do ‘flatfooted’ children suffer?
The aim of this study was to establish the natural
course of unrevised asymptomatic pseudotumours after metal-on-metal
(MoM) hip resurfacing during a six- to 12-month follow-up period.
We used repeated metal artefact reduction sequence (MARS)-magnetic
resonance imaging (MRI), serum metal ion analysis and clinical examination to
study 14 unrevised hips (mean patient age 52.7 years, 46 to 68,
5 female, 7 male) with a pseudotumour and 23 hips (mean patient
age 52.8 years, 38 to 69, 7 female, 16 male) without a pseudotumour.
The mean post-operative time to the first MARS-MRI scan was 4.3 years
(2.2 to 8.3), and mean time between the first and second MARS-MRI scan
was eight months (6 to 12). At the second MRI scan, the grade of
severity of the pseudotumour had not changed in 35 hips. One new
pseudotumour (Anderson C2 score, moderate) was observed, and one
pseudotumour was downgraded from C2 (moderate) to C1 (mild). In
general, the characteristics of the pseudotumours hardly changed. Repeated MARS-MRI scans within one year in patients with asymptomatic
pseudotumours after MoM hip resurfacing showed little or no variation.
In 23 patients without pseudotumour, one new asymptomatic pseudotumour
was detected. This is the first longitudinal study on the natural history of
pseudotumours using MARS-MRI scans in hip resurfacing, and mirrors
recent results for 28 mm diameter MoM total hip replacement. Cite this article:
Hypovitaminosis D has been identified as a common
risk factor for fragility fractures and poor fracture healing. Epidemiological
data on vitamin D deficiency have been gathered in various populations,
but the association between vertebral fragility fractures and hypovitaminosis
D, especially in males, remains unclear. The purpose of this study
was to evaluate serum levels of 25-hydroxyvitamin D (25-OH D) in
patients presenting with vertebral fragility fractures and to determine
whether patients with a vertebral fracture were at greater risk
of hypovitaminosis D than a control population. Furthermore, we
studied the seasonal variations in the serum vitamin D levels of
tested patients in order to clarify the relationship between other
known risk factors for osteoporosis and vitamin D levels. We measured
the serum 25-OH D levels of 246 patients admitted with vertebral
fractures (105 men, 141 female, mean age 69 years, Cite this article:
The objective of this study was to compare the early migration
characteristics and functional outcome of the Triathlon cemented
knee prosthesis with its predecessor, the Duracon cemented knee
prosthesis (both Stryker). A total 60 patients were prospectively randomised and tibial
component migration was measured by radiostereometric analysis (RSA)
at three months, one year and two years; clinical outcome was measured
by the American Knee Society score and the Knee Osteoarthritis and
Injury Outcome Score.Objectives
Methods
We examined the one-year risk of symptomatic
venous thromboembolism (VTE) following primary total hip replacement
(THR) among Danish patients and a comparison cohort from the general
population. From the Danish Hip Arthroplasty Registry we identified
all primary THRs performed in Denmark between 1995 and 2010 (n =
85 965). In all, 97% of patients undergoing THR received low-molecular-weight
heparin products during hospitalisation. Through the Danish Civil
Registration System we sampled a comparison cohort who had not undergone
THR from the general population (n = 257 895). Among the patients
undergoing THR, the risk of symptomatic VTE was 0.79% between 0
and 90 days after surgery and 0.29% between 91 and 365 days after
surgery. In the comparison cohort the corresponding risks were 0.05%
and 0.12%, respectively. The adjusted relative risks of symptomatic
VTE among patients undergoing THR were 15.84 (95% confidence interval
(CI) 13.12 to 19.12) during the first 90 days after surgery and
2.41 (95% CI 2.04 to 2.85) during 91 to 365 days after surgery,
compared with the comparison cohort. The relative risk of VTE was
elevated irrespective of the gender, age and level of comorbidity
at the time of THR. We concluded that THR was associated with an increased risk of
symptomatic VTE up to one year after surgery compared with the general
population, although the absolute risk is small.
We aimed to examine the characteristics of deep venous flow in
the leg in a cast and the effects of a wearable neuromuscular stimulator
(geko; FirstKind Ltd) and also to explore the participants’ tolerance
of the stimulator. This is an open-label physiological study on ten healthy volunteers.
Duplex ultrasonography of the superficial femoral vein measured
normal flow and cross-sectional area in the standing and supine
positions (with the lower limb initially horizontal and then elevated).
Flow measurements were repeated during activation of the geko stimulator
placed over the peroneal nerve. The process was repeated after the
application of a below-knee cast. Participants evaluated discomfort
using a questionnaire (verbal rating score) and a scoring index
(visual analogue scale).Objectives
Methods
The aims of this piece of work were to: 1) record the background
concentrations of blood chromium (Cr) and cobalt (Co) concentrations
in a large group of subjects; 2) to compare blood/serum Cr and Co
concentrations with retrieved metal-on-metal (MoM) hip resurfacings;
3) to examine the distribution of Co and Cr in the serum and whole
blood of patients with MoM hip arthroplasties; and 4) to further
understand the partitioning of metal ions between the serum and
whole blood fractions. A total of 3042 blood samples donated to the local transfusion
centre were analysed to record Co and Cr concentrations. Also, 91
hip resurfacing devices from patients who had given pre-revision
blood/serum samples for metal ion analysis underwent volumetric
wear assessment using a coordinate measuring machine. Linear regression analysis
was carried out and receiver operating characteristic curves were
constructed to assess the reliability of metal ions to identify
abnormally wearing implants. The relationship between serum and
whole blood concentrations of Cr and Co in 1048 patients was analysed
using Bland-Altman charts. This relationship was further investigated
in an Objectives
Methods
It has been proposed that intervertebral disc degeneration might be caused by low-grade infection. The purpose of the present study was to assess the incidence of herpes viruses in intervertebral disc specimens from patients with lumbar disc herniation. A polymerase chain reaction based assay was applied to screen for the DNA of eight different herpes viruses in 16 patients and two controls. DNA of at least one herpes virus was detected in 13 specimens (81.25%). Herpes Simplex Virus type-1 (HSV-1) was the most frequently detected virus (56.25%), followed by Cytomegalovirus (CMV) (37.5%). In two patients, co-infection by both HSV-1 and CMV was detected. All samples, including the control specimens, were negative for Herpes Simplex Virus type-2, Varicella Zoster Virus, Epstein Barr Virus, Human Herpes Viruses 6, 7 and 8. The absence of an acute infection was confirmed both at the serological and mRNA level. To our knowledge this is the first unequivocal evidence of the presence of herpes virus DNA in intervertebral disc specimens of patients with lumbar disc herniation suggesting the potential role of herpes viruses as a contributing factor to the pathogenesis of degenerative disc disease.
A national, multi-centre study was designed in
which a questionnaire quantifying the degree of patient satisfaction
and residual symptoms in patients following total knee replacement
(TKR) was administered by an independent, blinded third party survey
centre. A total of 90% of patients reported satisfaction with the
overall functioning of their knee, but 66% felt their knee to be
‘normal’, with the reported incidence of residual symptoms and functional
problems ranging from 33% to 54%. Female patients and patients from
low-income households had increased odds of reporting dissatisfaction.
Neither the use of contemporary implant designs (gender-specific,
high-flex, rotating platform) or custom cutting guides (CCG) with
a neutral mechanical axis target improved patient-perceived outcomes.
However, use of a CCG to perform a so-called kinematically aligned
TKR showed a trend towards more patients reporting their knee to
feel ‘normal’ when compared with a so called mechanically aligned
TKR This data shows a degree of dissatisfaction and residual symptoms
following TKR, and that several recent modifications in implant
design and surgical technique have not improved the current situation. Cite this article:
The August 2014 Hip &
Pelvis Roundup360 looks at: Serial MRIs best for pseudotumour surveillance; Is ultrasound good enough for MOM follow-up?; Does weight loss in obese patients help?; Measuring acetabular anteversion on plain films; Two-stage one-stage too many in fungal hip revisions? and 35 is the magic number in arthroplasty.
Twins are often considered to be at an increased
risk of developmental dysplasia of the hip (DDH); we therefore investigated
whether multiple births have a higher incidence of DDH, and if selective
ultrasound scanning should be considered for these infants. We reviewed our records of all live births between 1 January
2004 and 31 December 2008 and included 25 246 single and 990 multiple
births. Multiple births did not have a significantly higher incidence
of DDH compared with single births (0.0030 We conclude that being a twin or triplet in itself is not a risk
factor for DDH and that selective ultrasound scanning is not indicated
for this population. Cite this article:
To assess the sensitivity and specificity of self-reported osteoporosis
compared with dual energy X-ray absorptiometry (DXA) defined osteoporosis,
and to describe medication use among participants with the condition. Data were obtained from a population-based longitudinal study
and assessed for the prevalence of osteoporosis, falls, fractures
and medication use. DXA scans were also undertaken.Objectives
Methods
There have been several studies examining the
association between the morphological characteristics seen in acetabular
dysplasia and the incidence of the osteoarthritis (OA). However, most studies focus mainly on acetabular morphological
analysis, and few studies have scrutinised the effect of femoral
morphology. In this study we enrolled 36 patients with bilateral
acetabular dysplasia and early or mid-stage OA in one hip and no
OA in the contralateral hip. CT scans were performed from the iliac
crest to 2 cm inferior to the tibial tuberosity, and the morphological
characteristics of both acetabulum and femur were studied. In addition, 200 hips in 100 healthy volunteer Chinese adults
formed a control group. The results showed that the dysplastic group
with OA had a significantly larger femoral neck anteversion and
a significantly shorter abductor lever arm than both the dysplastic
group without OA and the controls. Femoral neck anteversion had
a significant negative correlation with the length of the abductor
lever arm and we conclude that it may contribute to the development
of OA in dysplastic hips. Cite this article:
The August 2014 Spine Roundup360 looks at: rhBMP complicates cervical spine surgery; posterior longitudinal ligament revisited; thoracolumbar posterior instrumentation without fusion in burst fractures; risk modelling for VTE events in spinal surgery; the consequences of dural tears in microdiscectomy; trends in revision spinal surgery; radiofrequency denervation likely effective in facet joint pain and hooks optimally biomechanically transition posterior instrumentation.
A small proportion of patients have persistent
pain after total knee replacement (TKR). The primary aim of this study
was to record the prevalence of pain after TKR at specific intervals
post-operatively and to ascertain the impact of neuropathic pain.
The secondary aim was to establish any predictive factors that could
be used to identify patients who were likely to have high levels
of pain or neuropathic pain after TKR. A total of 96 patients were included in the study. Their mean
age was 71 years (48 to 89); 54 (56%) were female. The mean follow-up
was 46 months (39 to 51). Pre-operative demographic details were
recorded including a Visual Analogue Score (VAS) for pain, the Hospital
Anxiety and Depression score as well as the painDETECT score for neuropathic
pain. Functional outcome was assessed using the Oxford Knee score. The mean pre-operative VAS was 5.8 (1 to 10); and it improved
significantly at all time periods post-operatively (p <
0.001):
(from 4.5 at day three to five (1 to 10), 3.2 at six weeks (0 to
9), 2.4 at three months (0 to 7), 2.0 at six months (0 to 9), 1.7
at nine months (0 to 9), 1.5 at one year (0 to 8) and 2.0 at mean
46 months (0 to 10)). There was a high correlation (r >
0.7; p <
0.001) between the mean VAS scores for pain and the mean painDETECT
scores at three months, one year and three years post-operatively.
There was no correlation between the pre-operative scores and any
post-operative scores at any time point. We report the prevalence of pain and neuropathic pain at various
intervals up to three years after TKR. Neuropathic pain is an underestimated
problem in patients with pain after TKR. It peaks at between six
weeks and three-months post-operatively. However, from these data
we were unable to predict which patients are most likely to be affected. Cite this article:
We report the results of six trauma and orthopaedic
projects to Kenya in the last three years. The aims are to deliver both
a trauma service and teaching within two hospitals; one a district
hospital near Mount Kenya in Nanyuki, the other the largest public
hospital in Kenya in Mombasa. The Kenya Orthopaedic Project team
consists of a wide range of multidisciplinary professionals that
allows the experience to be shared across those specialties. A follow-up
clinic is held three months after each mission to review the patients.
To our knowledge there are no reported outcomes in the literature
for similar projects. A total of 211 operations have been performed and 400 patients
seen during the projects. Most cases were fractures of the lower
limb; we have been able to follow up 163 patients (77%) who underwent
surgical treatment. We reflect on the results so far and discuss
potential improvements for future missions.
Blood metal ions have been widely used to investigate
metal-on-metal hip replacements, but their ability to discriminate
between well-functioning and failed hips is not known. The Medicines
and Healthcare products Regulatory Agency (MHRA) has suggested a
cut-off level of 7 parts per billion (ppb). We performed a pair-matched, case-control study to investigate
the sensitivity and specificity of blood metal ion levels for diagnosing
failure in 176 patients with a unilateral metal-on-metal hip replacement.
We recruited 88 cases with a pre-revision, unexplained failed hip
and an equal number of matching controls with a well-functioning
hip. We investigated the 7 ppb cut-off level for the maximum of
cobalt or chromium and determined optimal mathematical cut-off levels
from receiver-operating characteristic curves. The 7 ppb cut-off level for the maximum of cobalt or chromium
had a specificity of 89% and sensitivity 52% for detecting a pre-operative
unexplained failed metal on metal hip replacement. The optimal cut-off
level for the maximum of cobalt or chromium was 4.97 ppb and had
sensitivity 63% and specificity 86%. Blood metal ions had good discriminant ability to separate failed
from well-functioning hip replacements. The MHRA cut-off level of
7 ppb provides a specific test but has poor sensitivity.
The aim of this study was first, to determine
whether CT scans undertaken to identify serious injury to the viscera were
of use in detecting clinically unrecognised fractures of the thoracolumbar
vertebrae, and second, to identify patients at risk of ‘missed injury’. We retrospectively analysed CT scans of the chest and abdomen
performed for blunt injury to the torso in 303 patients. These proved
to be positive for thoracic and intra-abdominal injuries in only
2% and 1.3% of cases, respectively. However, 51 (16.8%) showed a
fracture of the thoracolumbar vertebrae and these constituted our subset
for study. There were eight women and 43 men with mean age of 45.2
years (15 to 94). There were 29 (57%) stable and 22 (43%) unstable
fractures. Only 17 fractures (33.3%) had been anticipated after
clinical examination. Of the 22 unstable fractures, 11 (50%) were
anticipated. Thus, within the whole group of 303 patients, an unstable spinal
injury was missed in 11 patients (3.6%); no harm resulted as they
were all protected until the spine had been cleared. A subset analysis
revealed that patients with a high Injury Severity Score, a low
Glasgow Coma Scale and haemodynamic instability were most likely
to have a significant fracture in the absence of positive clinical
findings. This is the group at greatest risk. Clinical examination alone cannot detect significant fractures
of the thoracolumbar spine. It should be combined with CT imaging
to reduce the risk of missed injury.