Advertisement for orthosearch.org.uk
Results 761 - 780 of 982
Results per page:
The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 830 - 835
1 Jun 2015
Li SL Lu Y Wang MY

This study compares the outcomes of two methods of fixation of displaced fractures of the radial neck. The 58 patients with a mean age of 38.5 years (18 to 56), were treated in a non randomised study with screws (n = 29) or a plate and screws (n = 29) according to the surgeon’s preference.

The patients were reviewed at one year. Radiographs and functional evaluations were carried out up to one year post-operatively, using the Broberg and Morrey functional evaluation score, range of movement, and assessment of complications.

The mean functional scores did not differ significantly between groups (90 (55 to 100) vs 84; 50 to 100, p = 0.09), but the mean range of forearm rotation in screw group was significantly better than in the plate group (152°; 110° to 170° vs 134°; 80° to 170°, p = 0.001). Although not statistically significant, the screw group had a lower incidence of heterotopic ossification than the plate group (n = 1) than the plated group (n = 3) and the pathology was graded as less severe.

Cite this article: Bone Joint J 2015;97-B:830–5


Bone & Joint Research
Vol. 3, Issue 5 | Pages 161 - 168
1 May 2014
Mundi R Chaudhry H Mundi S Godin K Bhandari M

High-quality randomised controlled trials (RCTs) evaluating surgical therapies are fundamental to the delivery of evidence-based orthopaedics. Orthopaedic clinical trials have unique challenges; however, when these challenges are overcome, evidence from trials can be definitive in its impact on surgical practice. In this review, we highlight several issues that pose potential challenges to orthopaedic investigators aiming to perform surgical randomised controlled trials. We begin with a discussion on trial design issues, including the ethics of sham surgery, the importance of sample size, the need for patient-important outcomes, and overcoming expertise bias. We then explore features surrounding the execution of surgical randomised trials, including ethics review boards, the importance of organisational frameworks, and obtaining adequate funding.

Cite this article: Bone Joint Res 2014;3:161–8.


Bone & Joint Research
Vol. 4, Issue 6 | Pages 99 - 104
1 Jun 2015
Savaridas T Wallace RJ Dawson S Simpson AHRW

Objectives

There remains conflicting evidence regarding cortical bone strength following bisphosphonate therapy. As part of a study to assess the effects of bisphosphonate treatment on the healing of rat tibial fractures, the mechanical properties and radiological density of the uninjured contralateral tibia was assessed.

Methods

Skeletally mature aged rats were used. A total of 14 rats received 1µg/kg ibandronate (iban) daily and 17 rats received 1 ml 0.9% sodium chloride (control) daily. Stress at failure and toughness of the tibial diaphysis were calculated following four-point bending tests.


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1082 - 1089
1 Aug 2015
Tubeuf S Yu G Achten J Parsons NR Rangan A Lamb SE Costa ML

We present an economic evaluation using data from the Distal Radius Acute Fracture Fixation Trial (DRAFFT) to compare the relative cost effectiveness of percutaneous Kirschner wire (K-wire) fixation and volar locking-plate fixation for patients with dorsally-displaced fractures of the distal radius.

The cost effectiveness analysis (cost per quality-adjusted life year; QALY) was derived from a multi-centre, two-arm, parallel group, assessor-blind, randomised controlled trial which took place in 18 trauma centres in the United Kingdom. Data from 460 patients were available for analysis, which includes both a National Health Service cost perspective including costs of surgery, implants and healthcare resource use over a 12-month period after surgery, and a societal perspective, which includes the cost of time off work and the need for additional private care.

There was only a small difference in QALYs gained for patients treated with locking-plate fixation over those treated with K-wires. At a mean additional cost of £714 (95% confidence interval 588 to 865) per patient, locking-plate fixation presented an incremental cost effectiveness ratio (ICER) of £89 322 per QALY within the first 12 months of treatment. Sensitivity analyses were undertaken to assess the ICER of locking-plate fixation compared with K-wires. These were greater than £30 000.

Compared with locking-plate fixation, K-wire fixation is a ‘cost saving’ intervention, with similar health benefits.

Cite this article: Bone Joint J 2015;97-B:1082–9.


Bone & Joint 360
Vol. 4, Issue 1 | Pages 28 - 29
1 Feb 2015

The February 2015 Oncology Roundup360 looks at: Achieving global collaboration; A new standard for limb salvage; Inoperable chondrosarcoma and chemotherapy; Soft-tissue sarcoma and adjuvant chemotherapy; Missed diagnoses and malpractice in sarcoma; Radiofrequency and cartilage tumours


Bone & Joint 360
Vol. 2, Issue 3 | Pages 6 - 14
1 Jun 2013
Wallace WA

In the UK we have many surgeon inventors – surgeons who innovate and create new ways of doing things, who invent operations, who design new instruments to facilitate surgery or design new implants for using in patients. However truly successful surgeon inventors are a rare breed and they need to develop additional knowledge and skills during their career in order to push forward their devices and innovations. This article reviews my own experiences as a surgeon inventor and the highs and lows over the whole of my surgical career.


The aims of this study were to assess the efficacy of a newly designed radiological technique (the radial groove view) for the detection of protrusion of screws in the groove for the extensor pollicis longus tendon (EPL) during plating of distal radial fractures. We also aimed to determine the optimum position of the forearm to obtain this view. We initially analysed the anatomy of the EPL groove by performing three-dimensional CT on 51 normal forearms. The mean horizontal angle of the groove was 17.8° (14° to 23°). We found that the ideal position of the fluoroscopic beam to obtain this view was 20° in the horizontal plane and 5° in the sagittal plane.

We then intra-operatively assessed the use of the radial groove view for detecting protrusion of screws in the EPL groove in 93 fractures that were treated by volar plating. A total of 13 protruding screws were detected. They were changed to shorter screws and these patients underwent CT scans of the wrist immediately post-operatively. There remained one screw that was protruding. These findings suggest that the use of the radial groove view intra-operatively is a good method of assessing the possible protrusion of screws into the groove of EPL when plating a fracture of the distal radius.

Cite this article: Bone Joint J 2013;95-B:1372–6.


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 689 - 695
1 May 2015
Basques BA Bohl DD Golinvaux NS Samuel AM Grauer JG

The aim of this study was to compare the operating time, length of stay (LOS), adverse events and rate of re-admission for elderly patients with a fracture of the hip treated using either general or spinal anaesthesia. Patients aged ≥ 70 years who underwent surgery for a fracture of the hip between 2010 and 2012 were identified from the American College of Surgeons National Surgical Quality Improvement Program (ACS-NSQIP) database. Of the 9842 patients who met the inclusion criteria, 7253 (73.7%) were treated with general anaesthesia and 2589 (26.3%) with spinal anaesthesia. On propensity-adjusted multivariate analysis, general anaesthesia was associated with slightly increased operating time (+5 minutes, 95% confidence interval (CI) +4 to +6, p < 0.001) and post-operative time in the operating room (+5 minutes, 95% CI +2 to +8, p < 0.001) compared with spinal anaesthesia. General anaesthesia was associated with a shorter LOS (hazard ratio (HR) 1.28, 95% CI 1.22 to 1.34, p < 0.001). Any adverse event (odds ratio (OR) 1.21, 95% CI 1.10 to 1.32, p < 0.001), thromboembolic events (OR 1.90, 95% CI 1.24 to 2.89, p = 0.003), any minor adverse event (OR 1.19, 95% CI 1.09 to 1.32, p < 0.001), and blood transfusion (OR 1.34, 95% CI 1.22 to 1.49, p < 0.001) were associated with general anaesthesia. General anaesthesia was associated with decreased rates of urinary tract infection (OR 0.73, 95% CI 0.62 to 0.87, p < 0.001). There was no clear overall advantage of one type of anaesthesia over the other, and surgeons should be aware of the specific risks and benefits associated with each type.

Cite this article: Bone Joint J 2015; 97-B:689–95.


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 696 - 704
1 May 2015
Kenawey M Krettek C Addosooki A Salama W Liodakis E

Unstable pelvic injuries in young children with an immature pelvis have different modes of failure from those in adolescents and adults. We describe the pathoanatomy of unstable pelvic injuries in these children, and the incidence of associated avulsion of the iliac apophysis and fracture of the ipsilateral fifth lumbar transverse process (L5-TP). We retrospectively reviewed the medical records of 33 children with Tile types B and C pelvic injuries admitted between 2007 and 2014; their mean age was 12.6 years (2 to 18) and 12 had an immature pelvis. Those with an immature pelvis commonly sustained symphyseal injuries anteriorly with diastasis, rather than the fractures of the pubic rami seen in adolescents. Posteriorly, transsacral fractures were more commonly encountered in mature children, whereas sacroiliac dislocations and fracture-dislocations were seen in both age groups. Avulsion of the iliac apophysis was identified in eight children, all of whom had an immature pelvis with an intact ipsilateral L5-TP. Young children with an immature pelvis are more susceptible to pubic symphysis and sacroiliac diastasis, whereas bony failures are more common in adolescents. Unstable pelvic injuries in young children are commonly associated with avulsion of the iliac apophysis, particularly with displaced SI joint dislocation and an intact ipsilateral L5-TP.

Cite this article: Bone Joint J 2015; 97-B:696–704.


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 391 - 397
1 Mar 2015
van Embden D Stollenwerck GANL Koster LA Kaptein BL Nelissen RGHH Schipper IB

The aim of this study was to quantify the stability of fracture-implant complex in fractures after fixation. A total of 15 patients with an undisplaced fracture of the femoral neck, treated with either a dynamic hip screw or three cannulated hip screws, and 16 patients with an AO31-A2 trochanteric fracture treated with a dynamic hip screw or a Gamma Nail, were included. Radiostereometric analysis was used at six weeks, four months and 12 months post-operatively to evaluate shortening and rotation.

Migration could be assessed in ten patients with a fracture of the femoral neck and seven with a trochanteric fracture. By four months post-operatively, a mean shortening of 5.4 mm (-0.04 to 16.1) had occurred in the fracture of the femoral neck group and 5.0 mm (-0.13 to 12.9) in the trochanteric fracture group. A wide range of rotation occurred in both types of fracture. Right-sided trochanteric fractures seem more rotationally stable than left-sided fractures.

This prospective study shows that migration at the fracture site occurs continuously during the first four post-operative months, after which stabilisation occurs. This information may allow the early recognition of patients at risk of failure of fixation.

Cite this article: Bone Joint J 2015;97-B:391–7.


Bone & Joint Research
Vol. 4, Issue 2 | Pages 23 - 28
1 Feb 2015
Auston DA Werner FW Simpson RB

Objectives

This study tests the biomechanical properties of adjacent locked plate constructs in a femur model using Sawbones. Previous studies have described biomechanical behaviour related to inter-device distances. We hypothesise that a smaller lateral inter-plate distance will result in a biomechanically stronger construct, and that addition of an anterior plate will increase the overall strength of the construct.

Methods

Sawbones were plated laterally with two large-fragment locking compression plates with inter-plate distances of 10 mm or 1 mm. Small-fragment locking compression plates of 7-hole, 9-hole, and 11-hole sizes were placed anteriorly to span the inter-plate distance. Four-point bend loading was applied, and the moment required to displace the constructs by 10 mm was recorded.


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1610 - 1616
1 Dec 2013
Epinette J Asencio G Essig J Llagonne B Nourissat C

We report a multicentre prospective consecutive study assessing the long-term outcome of the proximally hydroxyapatite (HA)-coated ABG II monobloc femoral component in a series of 1148 hips in 1053 patients with a mean age at surgery of 64.77 years (22 to 80) at a mean follow-up of 10.84 years (10 to 15.25). At latest follow-up, the mean total Harris hip score was 94.7 points (sd; 6.87; 49 to 100), and the mean Merle d’Aubigné–Postel score was 17.6 points (sd 1.12; 7 to 18). The mean total Engh radiological score score was 21.54 (sd 5.77; 3.5 to 27), with 95.81% of ‘confirmed ingrowth’, according to Engh’s classification. With aseptic loosening or pain as endpoints, three AGB II stems (0.26%) failed, giving a 99.7% survival rate (se 0.002; 95% confidence interval (CI) 0.994 to 1) at 14 years’ follow-up. The survival of patients ≤ 50 years of age (99.0% (se 0.011; 95% CI 0.969 to 1)) did not differ significantly from those of patients aged > 50 years (99.8% (se 0.002; 95% CI 0.994 to 1)). This study confirmed the excellent long-term results currently achieved with the ABG II proximally HA-coated monobloc stem.

Cite this article: Bone Joint J 2013;95-B:1610–16.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 100 - 103
1 Jan 2015
Rushton PRP Reed MR Pratt RK

The Nottingham Hip Fracture Score (NHFS) was developed to assess the risk of death following a fracture of the hip, based on pre-operative patient characteristics. We performed an independent validation of the NHFS, assessed the degree of geographical variation that exists between different units within the United Kingdom and attempted to define a NHFS level that is associated with high risk of mortality.

The NHFS was calculated retrospectively for consecutive patients presenting with a fracture of the hip to two hospitals in England. The observed 30-day mortality for each NHFS cohort was compared with that predicted by the NHFS using the Hosmer–Lemeshow test. The distribution of NHFS in the observed group was compared with data from other hospitals in the United Kingdom. The proportion of patients identified as high risk and the mortality within the high risk group were assessed for groups defined using different thresholds for the NHFS.

In all 1079 hip fractures were included in the analysis, with a mean age of 83 years (60 to 105), 284 (26%) male. Overall 30-day mortality was 7.3%. The NHFS was a significant predictor of 30-day mortality. Statistically significant differences in the distribution of the NHFS were present between different units in England (p < 0.001). A NHFS ≥ 6 appears to be an appropriate cut-point to identify patients at high risk of mortality following a fracture of the hip.

Cite this article: Bone Joint J 2015;96-B:100–3.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 672 - 678
1 May 2010
Robinson CM Wylie JR Ray AG Dempster NJ Olabi B Seah KTM Akhtar MA

We treated 47 patients with a mean age of 57 years (22 to 88) who had a proximal humeral fracture in which there was a severe varus deformity, using a standard operative protocol of anatomical reduction, fixation with a locking plate and supplementation by structural allografts in unstable fractures. The functional and radiological outcomes were reviewed.

At two years after operation the median Constant score was 86 points and the median Disabilities of the Arm, Shoulder and Hand score 17 points. Seven of the patients underwent further surgery, two for failure of fixation, three for dysfunction of the rotator cuff, and two for shoulder stiffness. The two cases of failure of fixation were attributable to violation of the operative protocol. In the 46 patients who retained their humeral head, all the fractures healed within the first year, with no sign of collapse or narrowing of the joint space. Longer follow-up will be required to confirm whether these initially satisfactory results are maintained.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 94 - 99
1 Jan 2015
Grammatopoulos G Wilson HA Kendrick BJL Pulford EC Lippett J Deakin M Andrade AJ Kambouroglou G

National Institute of Clinical Excellence guidelines state that cemented stems with an Orthopaedic Data Evaluation Panel (ODEP) rating of > 3B should be used for hemiarthroplasty when treating an intracapsular fracture of the femoral neck. These recommendations are based on studies in which most, if not all stems, did not hold such a rating.

This case-control study compared the outcome of hemiarthroplasty using a cemented (Exeter) or uncemented (Corail) femoral stem. These are the two prostheses most commonly used in hip arthroplasty in the UK.

Data were obtained from two centres; most patients had undergone hemiarthroplasty using a cemented Exeter stem (n = 292/412). Patients were matched for all factors that have been shown to influence mortality after an intracapsular fracture of the neck of the femur. Outcome measures included: complications, re-operations and mortality rates at two, seven, 30 and 365 days post-operatively. Comparable outcomes for the two stems were seen.

There were more intra-operative complications in the uncemented group (13% vs 0%), but the cemented group had a greater mortality in the early post-operative period (n = 6). There was no overall difference in the rate of re-operation (5%) or death (365 days: 26%) between the two groups at any time post-operatively.

This study therefore supports the use of both cemented and uncemented stems of proven design, with an ODEP rating of 10A, in patients with an intracapsular fracture of the neck of the femur.

Cite this article: Bone Joint J 2015;97-B:94–9.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 104 - 108
1 Jan 2015
Bretherton CP Parker MJ

There has been extensive discussion about the effect of delay to surgery on mortality in patients sustaining a fracture of the hip. Despite the low level of evidence provided by many studies, a consensus has been accepted that delay of > 48 hours is detrimental to survival. The aim of this prospective observational study was to determine if early surgery confers a survival benefit at 30 days.

Between 1989 and 2013, data were prospectively collected on patients sustaining a fracture of the hip at Peterborough City Hospital. They were divided into groups according to the time interval between admission and surgery. These thresholds ranged from <  6 hours to between 49 and 72 hours. The outcome which was assessed was the 30-day mortality. Adjustment for confounders was performed using multivariate binary logistic regression analysis. In all, 6638 patients aged > 60 years were included.

Worsening American Society of Anaesthesiologists grade (p < 0.001), increased age (p <  0.001) and extracapsular fracture (p < 0.019) increased the risk of 30-day mortality.

Increasing mobility score (p = 0.014), mini mental test score (p < 0.001) and female gender (p = 0.014) improved survival. After adjusting for these confounders, surgery before 12 hours improved survival compared with surgery after 12 hours (p = 0.013). Beyond this the increasing delay to surgery did not significantly affect the 30-day mortality.

Cite this article: Bone Joint J 2015;97-B:104–8.


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 56 - 59
1 Nov 2014
Konan S Garbuz DS Masri BA Duncan CP

Non-modular tapered fluted, titanium stems are available for use in femoral revision. The combination of taper and flutes on the stem provides axial and rotational stability, respectively. The material and surface properties of the stem promotes bone on-growth. If the surgeon is confident and reasonably experienced in the surgical use of this sort of design and the case is relatively straightforward, a non-modular design is effective. It also potentially reduces implant inventory, and circumvents the potential problems of taper junction corrosion and fatigue fracture. There are reports of excellent survival, good clinical and functional results and evidence of subsequent increase in proximal bone stock.

Cite this article: Bone Joint J 2014;96-B(11 Suppl A):56–9.


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 358 - 365
1 Mar 2015
Zhu L F. Zhang Yang D Chen A

The aim of this study was to evaluate the feasibility of using the intact S1 nerve root as a donor nerve to repair an avulsion of the contralateral lumbosacral plexus. Two cohorts of patients were recruited. In cohort 1, the L4–S4 nerve roots of 15 patients with a unilateral fracture of the sacrum and sacral nerve injury were stimulated during surgery to establish the precise functional distribution of the S1 nerve root and its proportional contribution to individual muscles. In cohort 2, the contralateral uninjured S1 nerve root of six patients with a unilateral lumbosacral plexus avulsion was transected extradurally and used with a 25 cm segment of the common peroneal nerve from the injured leg to reconstruct the avulsed plexus.

The results from cohort 1 showed that the innervation of S1 in each muscle can be compensated for by L4, L5, S2 and S3. Numbness in the toes and a reduction in strength were found after surgery in cohort 2, but these symptoms gradually disappeared and strength recovered. The results of electrophysiological studies of the donor limb were generally normal.

Severing the S1 nerve root does not appear to damage the healthy limb as far as clinical assessment and electrophysiological testing can determine. Consequently, the S1 nerve can be considered to be a suitable donor nerve for reconstruction of an avulsed contralateral lumbosacral plexus.

Cite this article: Bone Joint J 2015; 97-B:358–65.


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1631 - 1636
1 Dec 2014
Parkkinen M Madanat R Mäkinen TJ Mustonen A Koskinen SK Lindahl J

The role of arthroscopy in the treatment of soft-tissue injuries associated with proximal tibial fractures remains debatable. Our hypothesis was that MRI over-diagnoses clinically relevant associated soft-tissue injuries. This prospective study involved 50 consecutive patients who underwent surgical treatment for a split-depression fracture of the lateral tibial condyle (AO/OTA type B3.1). The mean age of patients was 50 years (23 to 86) and 27 (54%) were female. All patients had MRI and arthroscopy. Arthroscopy identified 12 tears of the lateral meniscus, including eight bucket-handle tears that were sutured and four that were resected, as well as six tears of the medial meniscus, of which five were resected. Lateral meniscal injuries were diagnosed on MRI in four of 12 patients, yielding an overall sensitivity of 33% (95% confidence interval (CI) 11 to 65). Specificity was 76% (95% CI 59 to 88), with nine tears diagnosed among 38 menisci that did not contain a tear. MRI identified medial meniscal injuries in four of six patients, yielding an overall sensitivity of 67% (95% CI 24 to 94). Specificity was 66% (95% CI 50 to 79), with 15 tears diagnosed in 44 menisci that did not contain tears.

MRI appears to offer only a marginal benefit as the specificity and sensitivity for diagnosing meniscal injuries are poor in patients with a fracture. There were fewer arthroscopically-confirmed associated lesions than reported previously in MRI studies.

Cite this article: Bone Joint J 2014;96-B:1631–6.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1287 - 1288
1 Sep 2011
Khanduja V