We report patient-reported outcomes and complications
associated with contemporary periacetabular osteotomy (PAO) surgery
in treating symptomatic acetabular dysplasia and compare these outcomes
with total hip arthroplasty (THA) in patients with similar demographic
details. Two consecutive cohorts included patients between aged
18 to 40 years who had undergone either PAO (100 hips; 24 male,
76 female) or THA (55 hips; 18 male, 37 female). At a mean follow-up
of 5.9 years (2 to 13), there was significant improvement in the
modified Harris hip pain (p <
0.001, PAO and p <
0.001, THA),
function (p <
0.001, PAO and p = 0.001, THA), and total scores
(p <
0.001, PAO and p <
0.001, THA) within each cohort. There
were no significant differences in the clinical outcome scores between
the groups. Complication rates were low and similar in each cohort
(p = 0.68). Similar to THA, contemporary PAO surgery is a clinically
effective procedure that improves function and activity levels,
provides pain relief and is associated with an acceptable complication
rate. Cite this article:
We prospectively followed 171 patients who underwent
bilateral unicompartmental knee replacement (UKR) over a period
of two years. Of these, 124 (72.5%) underwent a simultaneous bilateral
procedure and 47 (27.5%) underwent a staged procedure. The mean
cumulative operating time and length of hospital stay were both
shorter in the simultaneous group, by 22.5 minutes (p <
0.001)
and three days (p <
0.001), respectively. The mean reduction
in haemoglobin level post-operatively was greater by 0.15 g/dl in
the simultaneous group (p = 0.023), but this did not translate into
a significant increase in the number of patients requiring blood
transfusion (p = 1.000). The mean hospital cost was lower by $8892
in the simultaneous group (p <
0.001). There was no significant
difference in the rate of complications between the groups, and
at two-year follow-up there was no difference in the outcomes between
the two groups. We conclude that simultaneous bilateral UKR can be recommended
as an appropriate treatment for patients with bilateral medial compartment
osteoarthritis of the knee. Cite this article:
The aims of this study were to compare the diagnostic test characteristics
of ultrasound alone, metal artefact reduction sequence MRI (MARS-MRI)
alone, and ultrasound combined with MARS-MRI for identifying intra-operative
pseudotumours in metal-on-metal hip resurfacing (MoMHR) patients
undergoing revision surgery. This retrospective diagnostic accuracy study involved 39 patients
(40 MoMHRs). The time between imaging modalities was a mean of 14.6
days (0 to 90), with imaging performed at a mean of 5.3 months (0.06
to 12) before revision. The prevalence of intra-operative pseudotumours
was 82.5% (n = 33).Aims
Methods
We report on the long-term results of 163 bicruciate-retaining
Hermes 2C total knee replacements in 130 patients at a mean follow-up
of 22.4 years (20.3 to 23.5). Even when the anterior cruciate ligament
had a partially degenerative appearance it was preserved as long
as the knee had a normal anterior drawer and Lachman’s test pre-operatively. The
description and surgical technique of this minimally constrained
prosthesis were published in 1983 and the ten-year clinical results
in 1999. A total of 12% of the knees (20 of 163) in this study were revised
because of wear of the polyethylene tibial insert. Excellent stability
was achieved and the incidence of aseptic component loosening was
4.3% (seven of 163). The survival rate using revision for any reason
as the endpoint was 82% (95% confidence interval 76.2 to 88.0). Although this series included a relatively small number of replacements,
it demonstrated that the anterior cruciate ligament, even when partially
degenerated at the time of TKR, remained functional and provided
adequate stability at a long-term follow-up. Cite this article:
We performed a systematic review and meta-analysis
of modern total ankle replacements (TARs) to determine the survivorship,
outcome, complications, radiological findings and range of movement,
in patients with end-stage osteoarthritis (OA) of the ankle who
undergo this procedure. We used the methodology of the Cochrane Collaboration,
which uses risk of bias profiling to assess the quality of papers
in favour of a domain-based approach. Continuous outcome scores
were pooled across studies using the generic inverse variance method
and the random-effects model was used to incorporate clinical and
methodological heterogeneity. We included 58 papers (7942 TARs)
with an interobserver reliability (Kappa) for selection, performance,
attrition, detection and reporting bias of between 0.83 and 0.98.
The overall survivorship was 89% at ten years with an annual failure
rate of 1.2% (95% confidence interval (CI) 0.7 to 1.6). The mean
American Orthopaedic Foot and Ankle Society score changed from 40 (95%
CI 36 to 43) pre-operatively to 80 (95% CI 76 to 84) at a mean follow-up
of 8.2 years (7 to 10) (p <
0.01). Radiolucencies were identified
in up to 23% of TARs after a mean of 4.4 years (2.3 to 9.6). The
mean total range of movement improved from 23° (95% CI 19 to 26)
to 34° (95% CI 26 to 41) (p = 0.01). Our study demonstrates that TAR has a positive impact on patients’
lives, with benefits lasting ten years, as judged by improvement
in pain and function, as well as improved gait and increased range
of movement. However, the quality of evidence is weak and fraught
with biases and high quality randomised controlled trials are required
to compare TAR with other forms of treatment such as fusion. Cite this article:
Because there have been no standard methods to determine pre-operatively
the thickness of resection of the proximal tibia in unicompartmental
knee arthroplasty (UKA), information about the relationship between
the change of limb alignment and the joint line elevation would
be useful for pre-operative planning. The purpose of this study
was to clarify the correlation between the change of limb alignment
and the change of joint line height at the medial compartment after
UKA. A consecutive series of 42 medial UKAs was reviewed retrospectively.
These patients were assessed radiographically both pre- and post-operatively
with standing anteroposterior radiographs. The thickness of bone
resection at the proximal tibia and the distal femur was measured
radiographically. The relationship between the change of femorotibial
angle (δFTA) and the change of joint line height, was analysed.Objectives
Methods
The early failure and revision of bimodular primary
total hip arthroplasty prostheses requires the identification of the
risk factors for material loss and wear at the taper junctions through
taper wear analysis. Deviations in taper geometries between revised
and pristine modular neck tapers were determined using high resolution
tactile measurements. A new algorithm was developed and validated
to allow the quantitative analysis of material loss, complementing
the standard visual inspection currently used. The algorithm was applied to a sample of 27 retrievals ( Cite this article:
This study reports on the first 150 consecutive
Oxford cementless unicompartmental knee arthroplasties (UKA) performed
in an independent centre (126 patients). All eligible patients had
functional scores (Oxford knee score and high activity arthroplasty
score) recorded pre-operatively and at two- and five-years of follow-up. Fluoroscopically
aligned radiographs were taken at five years and analysed for any
evidence of radiolucent lines (RLLs), subsidence or loosening. The
mean age of the cohort was 63.6 years (39 to 86) with 81 (53.1%)
males. Excellent functional scores were maintained at five years
and there were no progressive RLLs demonstrated on radiographs.
Two patients underwent revision to a total knee arthroplasty giving
a revision rate of 0.23/100 (95% confidence interval 0.03 to 0.84)
component years with overall component survivorship of 98.7% at
five years. There were a further four patients who underwent further
surgery on the same knee, two underwent bearing exchanges for dislocation
and two underwent lateral UKAs for disease progression. This was
a marked improvement from other UKAs reported in New Zealand Joint
Registry data and supports the designing centre’s early results. Cite this article:
Despite the worldwide usage of the cemented Contemporary
acetabular component (Stryker), no published data are available
regarding its use in patients aged <
50 years. We undertook a
mid- to long-term follow-up study, including all consecutive patients
aged
<
50 years who underwent a primary total hip replacement using
the Contemporary acetabular component with the Exeter cemented stem
between January 1999 and January 2006. There were 152 hips in 126
patients, 61 men and 65 women, mean age at surgery 37.6 years (16
to 49 yrs). One patient was lost to follow-up. Mean clinical follow-up of all implants was 7.6 years (0.9 to
12.0). All clinical questionnaire scores, including Harris hip score,
Oxford hip score and several visual analogue scales, were found
to have improved. The eight year survivorship of all acetabular
components for the endpoints revision for any reason or revision
for aseptic loosening was 94.4% (95% confidence interval (CI) 89.2
to 97.2) and 96.4% (95% CI 91.6 to 98.5), respectively. Radiological follow-up
was complete for 146 implants. The eight year survival for the endpoint
radiological loosening was 93.1% (95% CI 86.2 to 96.6). Three surviving
implants were considered radiologically loose but were asymptomatic.
The presence of acetabular osteolysis (n = 17, 11.8%) and radiolucent
lines (n = 20, 13.9%) in the 144 surviving cups indicates a need
for continued observation in the second decade of follow-up in order
to observe their influence on long-term survival. The clinical and radiological data resulting in a ten-year survival
rate >
90% in young patients support the use of the Contemporary
acetabular component in this specific patient group. Cite this article:
This randomised trial evaluated the outcome of
a single design of unicompartmental arthroplasty of the knee (UKA) with
either a cemented all-polyethylene or a metal-backed modular tibial
component. A total of 63 knees in 45 patients (17 male, 28 female)
were included, 27 in the all-polyethylene group and 36 in the metal-backed
group. The mean age was 57.9 years (39.6 to 76.9). At a mean follow-up
of 6.4 years (5 to 9.9), 11 all-polyethylene components (41%) were
revised (at a mean of 5.8 years; 1.4 to 8.0) post-operatively and
two metal-backed components were revised (at one and five years).
One revision in both groups was for unexplained pain, one in the
metal-backed group was for progression of osteoarthritis. The others
in the all-polyethylene group were for aseptic loosening. The survivorship
at seven years calculated by the Kaplan–Meier method for the all-polyethylene
group was 56.5% (95% CI 31.9 to 75.2, number at risk 7) and for
the metal-backed group was 93.8% (95% CI 77.3 to 98.4, number at
risk 16) This difference was statistically significant (p <
0.001).
At the most recent follow-up, significantly better mean Western
Ontario and McMaster Universities Arthritis Index Scores were found
in the all-polyethylene group (13.4 This randomised study demonstrates that all-polyethylene components
in this design of fixed bearing UKA had unsatisfactory results with
significantly higher rates of failure before ten years compared
with the metal-back components. Cite this article:
The June 2015 Knee Roundup360 looks at: Cruciate substituting
The April 2015 Foot &
Ankle Roundup360 looks at: Plantar pressures linked to radiographs; Strength training for ankle instability?; Is weight loss good for your feet?; Diabetes and foot surgery complications; Tantalum for failed ankle arthroplasty?; Steroids, costs and Morton’s neuroma; Ankle arthritis and subtalar joint
Adverse reaction to wear and corrosion debris
is a cause for concern in total hip arthroplasty (THA). Modular junctions
are a potential source of such wear products and are associated
with secondary pseudotumour formation. We present a consecutive series of 17 patients treated at our
unit for this complication following metal-on-highly cross-linked
polyethylene (MoP) THA. We emphasise the risk of misdiagnosis as
infection, and present the aggregate laboratory results and pathological
findings in this series. The clinical presentation was pain, swelling or instability.
Solid, cystic and mixed soft-tissue lesions were noted on imaging
and confirmed intra-operatively. Corrosion at the head–neck junction
was noted in all cases. No bacteria were isolated on multiple pre-
and intra-operative samples yet the mean erythrocyte sedimentation
rate was 49 (9 to 100) and C-reactive protein 32 (0.6 to 106) and
stromal polymorphonuclear cell counts were noted in nine cases. Adverse soft–tissue reactions can occur in MoP THA owing to corrosion
products released from the head–neck junction. The diagnosis should
be carefully considered when investigating pain after THA. This
may avoid the misdiagnosis of periprosthetic infection with an unidentified
organism and mitigate the unnecessary management of these cases
with complete single- or two-stage exchange. Cite this article:
This study reports the results of 38 total hip
arthroplasties (THAs) in 33 patients aged <
50 years, using the
JRI Furlong hydroxyapatite ceramic (HAC)-coated femoral component.
This represents an update of previous reports of the same cohort
at ten and 16 years, which were reported in 2004 and 2009, respectively.
We describe the survival, radiological and functional outcomes at
a mean follow-up of 21 years (17 to 25). Of the surviving 34 THAs,
one underwent femoral revision for peri-prosthetic fracture after
21 years, and one patient (one hip) was lost to follow-up. Using
aseptic loosening as the end-point, 12 hips (31.5%) needed acetabular
revision but none needed femoral revision, demonstrating 100% survival
(95% confidence interval 89 to 100). In young patients with high demands, the Furlong HAC–coated femoral
component gives excellent long-term results. Cite this article:
The long term biological effects of wear products
following total hip arthroplasty (THA) are unclear. However, the indications
for THA are expanding, with increasingly younger patients undergoing
the procedure. This prospective, randomised study compared two groups of patients
undergoing THA after being randomised to receive one of two different
bearing surfaces: metal-on-polyethylene (MoP) n = 22 and metal-on-metal
(MoM) n = 23. We investigated the relationship between three variables:
bearing surface (MoP Our results demonstrated significantly higher mean cobalt and
chromium (Co and Cr) blood levels in the MoM group at all follow-up
points following surgery (p <
0.01), but there were no significant
differences in the chromosomal aberration indices between MoM and
MoP at two or five years (two years: p = 0.56, p = 0.08, p = 0.91, p
= 0.51 and five years: p = 0.086, p = 0.73, p = 0.06, p = 0.34)
for translocations, breaks, loss and gain of chromosomes respectively.
Regression analysis showed a strong linear relationship between
Cr levels and the total chromosomal aberration indices in the MoM
group (R2 = 0.90016), but this was not as strong for
Co (R2 = 0.68991). In the MoP group, the analysis revealed
a poor relationship between Cr levels and the total chromosomal
aberration indices (R2 = 0.23908) but a slightly stronger
relationship for Co (R2 = 0.64292). Across both groups,
Spearman’s correlation detected no overall association between Co and Cr
levels and each of the studied chromosomal aberrations. There remains
no clear indication which THA bearing couple is the most biocompatible,
especially in young active patients. While THA continues to be very
successful at alleviating pain and restoring function, the long-term
biological implications of the procedure still require further scrutiny. Cite this article:
In this study we evaluated whether pre-operative
Western Ontario and McMaster Universities (WOMAC) osteoarthritis
scores can predict satisfaction following total hip arthroplasty
(THA). Prospective data for a cohort of patients undergoing THA
from two large academic centres were collected, and pre-operative
and one-year post-operative WOMAC scores and a 25-point satisfaction
questionnaire were obtained for 446 patients. Satisfaction scores
were dichotomised into either improvement or deterioration. Scatter
plots and Spearman’s rank correlation coefficient were used to describe
the association between pre-operative WOMAC and one-year post-operative WOMAC
scores and patient satisfaction. Satisfaction was compared using
receiver operating characteristic (ROC) analysis against pre-operative,
post-operative and δ WOMAC scores. We found no relationship between pre-operative WOMAC scores and
one-year post-operative WOMAC or satisfaction scores, with Spearman’s
rank correlation coefficients of 0.16 and –0.05, respectively. The
ROC analysis showed areas under the curve (AUC) of 0.54 (pre-operative
WOMAC), 0.67 (post-operative WOMAC) and 0.43 (δ WOMAC), respectively,
for an improvement in satisfaction. We conclude that the pre-operative WOMAC score does not predict
the post-operative WOMAC score or patient satisfaction after THA,
and that WOMAC scores can therefore not be used to prioritise patient
care. Cite this article:
The aim of our study was to describe the characteristics,
treatment, and outcomes of patients with periprosthetic joint infection
(PJI) and normal inflammatory markers after total knee arthroplasty
(TKA) and total hip arthroplasty (THA). In total 538 TKAs and 414 THAs underwent surgical treatment for
PJI and met the inclusion criteria. Pre-operative erythrocyte sedimentation
rate (ESR) and C-reactive protein level (CRP) were reviewed to identify
the seronegative cohort. An age- and gender-matched cohort was identified
from the remaining patients for comparison. Overall, 4% of confirmed
infections were seronegative (21 TKA and 17 THA). Of those who underwent
pre-operative aspiration, cultures were positive in 76% of TKAs
(n = 13) and 64% of THAs (n = 7). Cell count and differential were
suggestive of infection in 85% of TKA (n = 11) and all THA aspirates
(n = 5). The most common organism was coagulase-negative Cite this article:
Tribocorrosion at the head–neck taper interface
– so-called ‘taperosis’ – may be a source of metal ions and particulate
debris in metal-on-polyethylene total hip arthroplasty (THA). We examined the effect of femoral head length on fretting and
corrosion in retrieved head–neck tapers Head length was observed to affect fretting (p = 0.03), with
28 mm + 8 mm femoral heads showing greater total fretting scores
than all other head lengths. The central zone of the femoral head
bore taper was subject to increased fretting damage (p = 0.01),
regardless of head length or stem offset. High-offset femoral stems
were associated with greater total fretting of the bore taper (p
= 0.04). Increased fretting damage is seen with longer head lengths and
high-offset femoral stems, and occurs within a central concentric
zone of the femoral head bore taper. Further investigation is required
to determine the effect of increased head size, and variations in
head–neck taper design. Cite this article:
In a randomised controlled pragmatic trial we
investigated whether local infiltration analgesia would result in earlier
readiness for discharge from hospital after total knee replacement
(TKR) than patient-controlled epidural analgesia (PCEA) plus femoral
nerve block. A total of 45 patients with a mean age of 65 years
(49 to 81) received a local infiltration with a peri-articular injection
of bupivacaine, morphine and methylprednisolone, as well as adjuvant
analgesics. In 45 PCEA+femoral nerve blockade patients with a mean
age of 67 years (50 to 84), analgesia included a bupivacaine nerve
block, bupivacaine/hydromorphone PCEA, and adjuvant analgesics.
The mean time until ready for discharge was 3.2 days (1 to 14) in
the local infiltration group and 3.2 days (1.8 to 7.0) in the PCEA+femoral
nerve blockade group. The mean pain scores for patients receiving
local infiltration were higher when walking (p = 0.0084), but there
were no statistically significant differences at rest. The mean
opioid consumption was higher in those receiving local infiltration. The choice between these two analgesic pathways should not be
made on the basis of time to discharge after surgery. Most secondary
outcomes were similar, but PCEA+femoral nerve blockade patients
had lower pain scores when walking and during continuous passive
movement. If PCEA+femoral nerve blockade is not readily available, local
infiltration provides similar length of stay and similar pain scores
at rest following TKR. Cite this article:
Tranexamic acid (TXA) has been used to reduce
blood loss during total hip arthroplasty (THA), but its use could increase
the risk of venous thromboembolic disease (VTE). Several studies
have reported that TXA does not increase the prevalence of deep
vein thrombosis (DVT), but most of those used routine chemical thromboprophylaxis,
thereby masking the potential increased risk of TXA on VTE. We wished
to ascertain whether TXA increases the prevalence of VTE in patients
undergoing THA without routine chemical thromboprophylaxis. We carried
out a retrospective case-control study in 254 patients who underwent
a primary THA, 127 of whom received TXA (1 g given pre-operatively)
and a control group of 127 who did not. All patients had mechanical
but no chemical thomboprophylaxis. Each patient was examined for
DVT by bilateral ultrasonography pre-operatively and on post-operative
days 1 and 7. TXA was found to statistically significantly increase
the incidence of total DVT on post-operative day 7 compared with
the control group (24 (18.9%) and 12 (9.4%), respectively; p <
0.05) but most cases of DVT were isolated distal DVT, with the exception
of one patient with proximal DVT in each group. One patient in the control
group developed a non-fatal symptomatic pulmonary embolism (PE).
The use of TXA did not appear to affect the prevalence of either
proximal DVT or PE. Cite this article: