Advertisement for orthosearch.org.uk
Results 721 - 740 of 1511
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 6 | Pages 938 - 942
1 Nov 1994
Karachalios T Sarangi P Newman J

We report a prospective case-controlled study which compared the outcome of knee replacement in seriously deformed and slightly deformed knees. There were 51 knees with varus or valgus deformity greater than 20 degrees matched for age, gender, disease, type of prosthesis and time of operation with a control group in which the alignment of the leg was within 5 degrees of normal. The clinical outcome at a mean 5.5 years was similar in the two groups. Some deformity persisted in 14 patients in the first group, 13 of whom were initially in valgus. These patients had a significantly poorer mean clinical outcome. Lateral dislocation or subluxation of the patella was found in four knees, all of which had had valgus deformity of 30 degrees or more


Objectives

Posterior condylar offset (PCO) and posterior tibial slope (PTS) are critical factors in total knee arthroplasty (TKA). A computational simulation was performed to evaluate the biomechanical effect of PCO and PTS on cruciate retaining TKA.

Methods

We generated a subject-specific computational model followed by the development of ± 1 mm, ± 2 mm and ± 3 mm PCO models in the posterior direction, and -3°, 0°, 3° and 6° PTS models with each of the PCO models. Using a validated finite element (FE) model, we investigated the influence of the changes in PCO and PTS on the contact stress in the patellar button and the forces on the posterior cruciate ligament (PCL), patellar tendon and quadriceps muscles under the deep knee-bend loading conditions.


Bone & Joint 360
Vol. 7, Issue 3 | Pages 27 - 29
1 Jun 2018


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 2 | Pages 242 - 248
1 Mar 1985
Bertin K Freeman M Samuelson K Ratcliffe S Todd R

Fifty-three failed knee replacements were revised using minimally constrained implants with smooth uncemented intramedullary stems and metal-backed tibial components. Polymethylmethacrylate was used only to replace lost bone near the surface of the implant. Excluding four knees which had serious postoperative complications, 91% had successful relief of pain, 84% had over 90 degrees of movement and 80% could walk for more than 30 minutes. Review of the radiographs showed that there were no progressive lucencies at the interface between bone and cement, and no subsidence of components or changes in alignment. At the uncemented stem-to-bone interface, thin white lines developed near the metal, and their significance is discussed. This revision technique is an effective treatment for aseptic failure of primary total knee arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 5 | Pages 737 - 741
1 Nov 1984
Rydholm U Tjornstrand B Pettersson H Lidgren L

Fifteen patients with rheumatoid arthritis had 19 elbow arthroplasties with the Wadsworth type of surface replacement prosthesis. After a follow-up period averaging 30 months, 11 patients with 15 elbow arthroplasties were entirely satisfied with their freedom from pain and range of movement. Radiologically, however, the humeral component was loose in 10 of the 19 elbows and the ulnar component in 5. Two patients had reoperation, one to remove a prosthesis for early deep infection and one to exchange a humeral component which was loose. The risk of mechanical loosening is reduced by accurate positioning of the humeral component, but there is a high potential for failure. Changes in the design of the prosthesis and better instrumentation for alignment of the components are desirable. Prosthetic replacement of the elbow should still be regarded as experimental


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 5 | Pages 653 - 657
1 Jul 2002
Robinson BJ Rees JL Price AJ Beard DJ Murray DW Smith PM Dodd CAF

When the Oxford unicompartmental meniscal bearing arthroplasty is used in the lateral compartment of the knee, 10% of the bearings dislocate. A radiological review was carried out to establish if dislocation was related to surgical technique. The postoperative radiographs of 46 lateral unicompartmental arthroplasties were analysed. Five variables which related to the position and alignment of the components were measured. Dislocations occurred in six knees. Only one of the five variables, the proximal tibial varus angle, had a statistically significant relationship to dislocation. This variable quantifies the height of the lateral joint line. The mean proximal tibial varus angle for knees the bearings of which had dislocated was 9° and for those which had not it was 5°. In both groups it was greater than would be expected in the normal knee (3°). Our study suggests that a high proximal tibial varus angle is associated with dislocation. The surgical technique should be modified to account for this, with care being taken to avoid damage to or over-distraction of the lateral soft tissues


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 5 | Pages 765 - 769
1 Sep 1992
Wallace M Hoffman E

We reviewed 28 children with unilateral middle-third fractures of the femoral shaft who had an angular deformity after union of 10 degrees to 26 degrees. At an average follow-up of 45 months (20 to 66), we measured remodelling of the proximal physis, the distal physis and the femoral shaft. The average correction was 85% of the initial deformity. We found that 74% of correction occurred at the physes and only 26% at the fracture site. Neither the direction nor the magnitude of the angulation much influenced the degree of remodelling. Younger children remodelled only a little better than older children. We conclude that in children under 13 years of age, malunion of as much as 25 degrees in any plane will remodel enough to give normal alignment of the joint surfaces


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 5 | Pages 666 - 671
1 Nov 1984
Allen P Denham R Swan A

Late degenerative changes are known to follow meniscectomy, but there is little agreement on their incidence or on which patients are most at risk. A total of 210 patients have been reviewed 10 to 22 years after meniscectomy, and long leg radiographs taken of both knees. Radiological degeneration was seen in 18%, while 7% had significant symptoms and signs. Statistical analysis showed increased changes in older patients, in those with abnormal leg alignment, and in those who had undergone lateral as against medial meniscectomy. Our findings emphasise the important mechanical function of the meniscus and support the current cautious approach to meniscectomy, especially for patients in high risk groups. They also indicate the value of early high tibial osteotomy for symptomatic varus deformity after medial meniscectomy


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 2 | Pages 267 - 269
1 Mar 1995
Pritchett J

Fifty patients with complex distal radial fractures treated by primary external fixation were compared with 50 with similar fractures treated by closed medullary pinning. All the patients had Frykman type-VIII injuries. The two groups were similar in regard to demographic characteristics and the method of treatment was randomly chosen. All the fractures healed within three months. In the external fixation group 92% of fractures healed in excellent alignment as did 88% of the medullary pinning group. Both groups had similar results with respect to eventual function, range of motion, and grip strength. Complications and complaints were fewer and the estimated costs of treatment were significantly less in the medullary pinning group. More patients were satisfied with closed medullary fixation than with external fixation


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 4 | Pages 498 - 499
1 Aug 1982
Shakespeare D Henderson N

The effect of calcaneal traction on the compartmental pressure in the legs of five individuals with tibial fractures was studied. Mean resting pressures without traction were found to be 31.9 mmHg for the deep posterior compartment and 27.0 mmHg for the anterior compartment. For each kilogram weight of traction applied the deep posterior pressure rose by 5.7 per cent of the resting value and the anterior pressure by 1.6 per cent. It is suggested that the weight of traction should be only sufficient to render the patient comfortable and maintain alignment of the limb. Excessive traction is likely to increase the risk of compartmental ischaemia. The application of six kilograms of traction would raise the mean resting pressure by 34 per cent from 31.9 to 42.7 mmHg


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1442 - 1448
1 Nov 2018
Hipfl C Janz V Löchel J Perka C Wassilew GI

Aims

Severe acetabular bone loss and pelvic discontinuity (PD) present particular challenges in revision total hip arthroplasty. To deal with such complex situations, cup-cage reconstruction has emerged as an option for treating this situation. We aimed to examine our success in using this technique for these anatomical problems.

Patients and Methods

We undertook a retrospective, single-centre series of 35 hips in 34 patients (seven male, 27 female) treated with a cup-cage construct using a trabecular metal shell in conjunction with a titanium cage, for severe acetabular bone loss between 2011 and 2015. The mean age at the time of surgery was 70 years (42 to 85) and all patients had an acetabular defect graded as Paprosky Type 2C through to 3B, with 24 hips (69%) having PD. The mean follow-up was 47 months (25 to 84).


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 3 | Pages 413 - 417
1 Apr 2002
McLauchlan GJ Cowan B Annan IH Robb JE

In a prospective, randomised controlled trial, 68 children who had a completely displaced metaphyseal fracture of the distal radius were treated either by manipulation (MUA) and application of an above-elbow cast alone or by the additional insertion of a percutaneous Kirschner (K-) wire. Full radiological follow-up to union was obtained in 65 children and 56 returned for clinical evaluation three months after injury. Maintenance of reduction was significantly better in the K-wire group and fewer follow-up radiographs were required. There was no significant difference in the clinical outcome measured three months after injury. Seven of 33 patients in the MUA group had to undergo a second procedure because of an unacceptable position compared with none of the 35 in the K-wire group (chi-squared test, p < 0.01). One patient in the K-wire group required exploration for recovery of a migrated wire. We conclude that the use of a percutaneous K-wire to augment the reduction of the fracture in children who have a completely displaced metaphyseal fracture of the distal radius is a safe and reliable way of maintaining alignment of the fracture


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1524 - 1532
1 Nov 2018
Angélico ACC Garcia LM Icuma TR Herrero CF Maranho DA

Aims

The aims of this study were to evaluate the abductor function in moderate and severe slipped capital femoral epiphysis (SCFE), comparing the results of a corrective osteotomy at the base of the femoral neck and osteoplasty with 1) in situ epiphysiodesis for mild SCFE, 2) contralateral unaffected hips, and 3) hips from healthy individuals.

Patients and Methods

A total of 24 patients (mean age 14.9 years (sd 1.6); 17 male and seven female patients) with moderate or severe SCFE (28 hips) underwent base of neck osteotomy and osteoplasty between 2012 and 2015. In situ epiphysiodesis was performed in seven contralateral hips with mild slip. A control cohort was composed of 15 healthy individuals (mean age 16.5 years (sd 2.5); six male and nine female patients). The abductor function was assessed using isokinetic dynamometry and range of abduction, with a minimum one-year follow-up.


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 3 | Pages 358 - 364
1 May 1993
Eyres K Bell M Kanis J

We studied the quantity and rate of formation of new bone during lengthening of 17 limb segments in 10 patients using dual-energy X-ray absorptiometry (DEXA), ultrasonography and radiography. Whereas new bone was detected by both DEXA and ultrasonography within 1 to 2 weeks of distraction, it was not visible on the radiographs until 4 to 8 weeks. Limb alignment and gap measurement were accurately assessed by DEXA without the need for standard radiographs or scanograms. With ultrasound the distraction gap appeared as an echolucent window which narrowed progressively producing a hyper-reflecting line after which further consolidation could not be assessed. As measured by DEXA the density of the new bone at this stage was approximately 45% of control values and did not represent normal cortication. Whereas ultrasound could be used to identify defects in mineralisation and to determine when to dynamise the fixator system, DEXA could measure the quantity and rate of formation of bone throughout lengthening


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 6 | Pages 1044 - 1049
1 Nov 1990
Horibe S Shino K Nagano J Nakamura H Tanaka M Ono K

In order to determine whether an allogeneic tendon could be used to replace an extra-articular ligament, the right medial collateral ligament from 11 adult dogs was replaced with a fresh-frozen allogeneic patellar tendon. At each of 3, 6, 15, 30 and 52 weeks postoperatively, one dog was killed for micro-angiographical and histological studies; at 52 weeks the remaining six dogs were killed for tensile testing. Micro-angiograms showed that the allogeneic tendon was revascularised with infiltration of the mesenchymal cells from the surrounding tissues and both ends of the graft. Histologically, the alignment of the fibroblasts and collagen bundles became more regular over time, without any immunological rejection. A biomechanical study performed at 52 weeks found no significant difference in stiffness or ultimate load between normal and reconstructed ligaments. Fresh-frozen allogeneic tendons are therefore considered useful for extra-articular ligament reconstruction


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 2 | Pages 211 - 216
1 Mar 1988
Aglietti P Buzzi R

We have reviewed 85 knees in 71 patients after total-condylar posteriorly stabilised (Insall-Burstein) knee replacement with an average follow-up of five years. Excellent or good results were obtained in 90% with an average maximum flexion of 98 degrees. The four poor results (5%) included two with deep infection, one with patellar dislocation and one with loosening. Four other knees (5%) showed signs of probable tibial loosening, but the patients were asymptomatic, the clinical results had not deteriorated with time and lucent lines had not progressed. Varus alignment of the knee and a varus tilt of more than 2 degrees of the tibial component correlated with the incidence of lucent lines around the tibial implant. No patellar stress fractures were seen but impingement symptoms were present in 20%, although they were troublesome in less than half of them. The virtue of the prosthesis lies in its versatility for use in the severely deformed joint


The Journal of Bone & Joint Surgery British Volume
Vol. 42-B, Issue 4 | Pages 749 - 760
1 Nov 1960
Piggott H

1. Pathological hallux valgus may be differentiated from an increase in the normal valgus alignment of the great toe by the relationship to each other of the articular surfaces of the first metatarso-phalangeal joint; these are congruous in the normal joint, but displaced on each other in the pathological. 2. The earliest change is lateral deviation of the proximal phalanx on the metatarsal head, which may progress rapidly to subluxation. 3. Subluxation is an early change in a high proportion of cases, and is frequently present when the patient is first seen in adolescence. 4. Once subluxation has occurred progression of the deformity is likely. 5. Metatarsus primus varus and hallux valgus increase pari passu. There is not enough evidence to be certain which of these is the primary change, but such as there is suggests that lateral deviation of the great toe occurs first, and increase in the intermetatarsal angle is secondary to this. 6. It is suggested that hallux valgus should be regarded primarily and fundamentally as a subluxation, or tendency to subluxation, of the first metatarso-phalangeal joint


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1434 - 1441
1 Nov 2018
Blakeney WG Beaulieu Y Puliero B Lavigne M Roy A Massé V Vendittoli P

Aims

This study reports the mid-term results of total hip arthroplasty (THA) performed using a monoblock acetabular component with a large-diameter head (LDH) ceramic-on-ceramic (CoC) bearing.

Patients and Methods

Of the 276 hips (246 patients) included in this study, 264 (96%) were reviewed at a mean of 67 months (48 to 79) postoperatively. Procedures were performed with a mini posterior approach. Clinical and radiological outcomes were recorded at regular intervals. A noise assessment questionnaire was completed at last follow-up.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 6 | Pages 982 - 986
1 Nov 1999
Ritter MA Zhou H Keating CM Keating EM Faris PM Meding JB Berend ME

We have made a retrospective review of 185 cemented Charnley total hip arthroplasties performed between 1970 and 1974 to determine the relationships between radiological variables and failure of the femoral and acetabular components. We measured the acetabular wear, the orientation of the cup, the thickness and consistency of acetabular and femoral cement mantles, radiolucency and femoral alignment. The mean follow-up was for 11.7 years. Femoral loosening was demonstrable radiologically in 15 hips (8.1%), ten (5.4%) of which were revised during the period of follow-up. Only when the first postoperative radiograph showed a thin cement mantle in Gruen zone 5 was there a significant association with failure of the femoral component. There were 12 loose acetabular components (6.5%), nine (4.8%) of which were revised. When the initial radiograph after operation showed radiolucency in DeLee and Charnley zone 1, the incidence of acetabular loosening was 28.21%. If such radiolucency was not present, the incidence of acetabular loosening was only 0.69%. Our findings emphasise the importance of careful cementing


Bone & Joint 360
Vol. 7, Issue 5 | Pages 24 - 27
1 Oct 2018