Advertisement for orthosearch.org.uk
Results 681 - 700 of 878
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1259 - 1264
1 Sep 2011
Wähnert D Windolf M Brianza S Rothstock S Radtke R Brighenti V Schwieger K

We investigated the static and cyclical strength of parallel and angulated locking plate screws using rigid polyurethane foam (0.32 g/cm3) and bovine cancellous bone blocks. Custom-made stainless steel plates with two conically threaded screw holes with different angulations (parallel, 10° and 20° divergent) and 5 mm self-tapping locking screws underwent pull-out and cyclical pull and bending tests. The bovine cancellous blocks were only subjected to static pull-out testing. We also performed finite element analysis for the static pull-out test of the parallel and 20° configurations. In both the foam model and the bovine cancellous bone we found the significantly highest pull-out force for the parallel constructs. In the finite element analysis there was a 47% more damage in the 20° divergent constructs than in the parallel configuration. Under cyclical loading, the mean number of cycles to failure was significantly higher for the parallel group, followed by the 10° and 20° divergent configurations.

In our laboratory setting we clearly showed the biomechanical disadvantage of a diverging locking screw angle under static and cyclical loading.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 8 | Pages 1045 - 1048
1 Aug 2011
Avery PP Baker RP Walton MJ Rooker JC Squires B Gargan MF Bannister GC

We reviewed the seven- to ten-year results of our previously reported prospective randomised controlled trial comparing total hip replacement and hemiarthroplasty for the treatment of displaced intracapsular fracture of the femoral neck. Of our original study group of 81 patients, 47 were still alive.

After a mean follow up of nine years (7 to 10) overall mortality was 32.5% and 51.2% after total hip replacement and hemiarthroplasty, respectively (p = 0.09). At 100 months postoperatively a significantly greater proportion of hemiarthroplasty patients had died (p = 0.026). Three hips dislocated following total hip replacement and none after hemiarthroplasty. In both the total hip replacement and hemiarthroplasty groups a deterioration had occurred in walking distance (p = 0.02 and p < 0.001, respectively). One total hip replacement required revision compared with four hemiarthroplasties which were revised to total hip replacements. All surviving patients with a total hip replacement demonstrated wear of the cemented polyethylene component and all hemiarthroplasties had produced acetabular erosion.

There was lower mortality (p = 0.013) and a trend towards superior function in patients with a total hip replacement in the medium term.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 8 | Pages 1088 - 1092
1 Aug 2011
Lizaur A Sanz-Reig J Gonzalez-Parreño S

The purpose of this study was to review the long-term outcomes of a previously reported prospective series of 46 type III acromioclavicular dislocations. These were treated surgically with temporary fixation of the acromioclavicular joint with wires, repair of the acromioclavicular ligaments, and overlapped suture of the deltoid and trapezius muscles. Of the 46 patients, one had died, four could not be traced, and three declined to return for follow-up, leaving 38 patients in the study. There were 36 men and two women, with a mean age at follow-up of 57.3 years (41 to 71). The mean follow-up was 24.2 years (21 to 26).

Patients were evaluated using the Imatani and University of California, Los Angeles (UCLA) scoring systems. Their subjective status was assessed using the Disabilities of the Arm, Shoulder and Hand and Simple Shoulder Test questionnaires, and a visual analogue scale for patient satisfaction. The examination included radiographs of the shoulder.

At a follow-up of 21 years, the results were satisfactory in 35 (92.1%) patients and unsatisfactory in three (7.9%). In total, 35 patients (92.1%) reported no pain, one slight pain, and two moderate pain. All except two patients had a full range of shoulder movement compared with the opposite side. Unsatisfactory results were the result of early redisplacement in two patients, and osteoarthritis without redisplacement in one. According to the Imatani and UCLA scores, there was no difference between the operated shoulder and the opposite shoulder (p > 0.05). Given the same situation, 35 (92.1%) patients would opt for the same surgical treatment again.

Operative treatment of type III acromioclavicular joint injuries produces satisfactory long-term results.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 7 | Pages 881 - 885
1 Jul 2011
Cobb JP Davda K Ahmad A Harris SJ Masjedi M Hart AJ

Large-head metal-on-metal total hip replacement has a failure rate of almost 8% at five years, three times the revision rate of conventional hip replacement. Unexplained pain remains a feature of this type of arthroplasty.

All designs of the femoral component of large-head metal-on-metal total hip replacements share a unique characteristic: a subtended angle of 120° defining the proportion of a sphere that the head represents. Using MRI, we measured the contact area of the iliopsoas tendon on the femoral head in sagittal reconstruction of 20 hips of patients with symptomatic femoroacetabular impingement. We also measured the articular extent of the femoral head on 40 normal hips and ten with cam-type deformities. Finally, we performed virtual hip resurfacing on normal and cam-type hips, avoiding overhang of the metal rim inferomedially.

The articular surface of the femoral head has a subtended angle of 120° anteriorly and posteriorly, but only 100° medially. Virtual surgery in a normally shaped femoral head showed a 20° skirt of metal protruding medially where iliopsoas articulates.

The excessive extent of the large-diameter femoral components may cause iliopsoas impingement independently of the acetabular component. This may be the cause of postoperative pain with these implants.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 8 | Pages 1176 - 1181
1 Aug 2010
Tayton E Evans S O’Doherty D

We implanted titanium and carbon fibre-reinforced plastic (CFRP) femoral prostheses of the same dimensions into five prosthetic femora. An abductor jig was attached and a 1 kN load applied. This was repeated with five control femora. Digital image correlation was used to give a detailed two-dimensional strain map of the medial cortex of the proximal femur. Both implants caused stress shielding around the calcar. Distally, the titanium implant showed stress shielding, whereas the CFRP prosthesis did not produce a strain pattern which was statistically different from the controls. There was a reduction in strain beyond the tip of both the implants.

This investigation indicates that use of the CFRP stem should avoid stress shielding in total hip replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 7 | Pages 914 - 920
1 Jul 2011
Rogers BA Middleton FR Shearwood-Porter N Kinch S Roques A Bradley NW Browne M

Two-stage revision surgery for infected total knee replacement offers the highest rate of success for the elimination of infection. The use of articulating antibiotic-laden cement spacers during the first stage to eradicate infection also allows protection of the soft tissues against excessive scarring and stiffness. We have investigated the effect of cyclical loading of cement spacers on the elution of antibiotics. Femoral and tibial spacers containing vancomycin at a constant concentration and tobramycin of varying concentrations were studied in vitro. The specimens were immersed and loaded cyclically to 250 N, with a flexion excursion of 45°, for 35 000 cycles. The buffered solution was sampled at set intervals and the antibiotic concentration was established so that the elution could be calculated. Unloaded samples were used as a control group for statistical comparison.

The elution of tobramycin increased proportionately with its concentration in cement and was significantly higher at all sampling times from five minutes to 1680 minutes in loaded components compared with the control group (p = 0.021 and p = 0.003, respectively). A similar trend was observed with elution of vancomycin, but this failed to reach statistical significance at five, 1320 and 1560 minutes (p = 0.0508, p = 0.067 and p = 0.347, respectively). However, cyclically loaded and control components showed an increased elution of vancomycin with increasing tobramycin concentration in the specimens, despite all components having the same vancomycin concentration. The concentration of tobramycin influences both tobramycin and vancomycin elution from bone cement. Cyclical loading of the cement spacers enhanced the elution of vancomycin and tobramycin.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 7 | Pages 949 - 954
1 Jul 2011
Bisseling P Zeilstra DJ Hol AM van Susante JLC

The purpose of this study was to evaluate whether concerns about the release of metal ions in metal-on-metal total hip replacements (THR) should be extended to patients with metal-bearing total disc replacements (TDR).

Cobalt and chromium levels in whole blood and serum were measured in ten patients with a single-level TDR after a mean follow-up of 34.5 months (13 to 61) using inductively-coupled plasma mass spectrometry. These metal ion levels were compared with pre-operative control levels in 81 patients and with metal ion levels 12 months after metal-on-metal THR (n = 21) and resurfacing hip replacement (n = 36). Flexion-extension radiographs were used to verify movement of the TDR.

Cobalt levels in whole blood and serum were significantly lower in the TDR group than in either the THR (p = 0.007) or the resurfacing group (p < 0.001). Both chromium levels were also significantly lower after TDR versus hip resurfacing (p < 0.001), whereas compared with THR this difference was only significant for serum levels (p = 0.008). All metal ion levels in the THR and resurfacing groups were significantly higher than in the control group (p < 0.001). In the TDR group only cobalt in whole blood appeared to be significantly higher (p < 0.001). The median range of movement of the TDR was 15.5° (10° to 22°).

These results suggest that there is minimal cause for concern about high metal ion concentrations after TDR, as the levels appear to be only moderately elevated. However, spinal surgeons using a metal-on-metal TDR should still be aware of concerns expressed in the hip replacement literature about toxicity from elevated metal ion levels, and inform their patients appropriately.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 811 - 816
1 Jun 2011
Duckworth AD Bennet SJ Aderinto J Keating JF

The aim of this study was to determine the comorbid risk factors for failure in young patients who undergo fixation of a displaced fracture of the femoral neck. We identified from a prospective database all such patients ≤ 60 years of age treated with reduction and internal fixation. The main outcome measures were union, failure of fixation, nonunion and the development of avascular necrosis.

There were 122 patients in the study. Union occurred in 83 patients (68%) at a mean follow-up of 58 months (18 to 155). Complications occurred in 39 patients (32%) at a mean of 11 months (0.5 to 39). The rate of nonunion was 7.4% (n = 9) and of avascular necrosis was 11.5% (n = 14). Failures were more common in patients over 40 years of age (p = 0.03). Univariate analysis identified that delay in time to fixation (> 24 hours), alcohol excess and pre-existing renal, liver or respiratory disease were all predictive of failure (all p < 0.05). Of these, alcohol excess, renal disease and respiratory disease were most predictive of failure on multivariate analysis.

Younger patients with fractures of the femoral neck should be carefully evaluated for comorbidities that increase the risk of failure after reduction and fixation. In patients with a history of alcohol abuse, renal or respiratory disease, arthroplasty should be considered as an alternative treatment.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 634 - 638
1 May 2011
Cho T Kim J Lee JW Lee K Park MS Yoo WJ Chung CY Choi IH

We investigated the fracture-free survival of long bones stabilised by a telescopic intramedullary rod (TIMR) in patients with osteogenesis imperfecta with respect to the remodelling status of fracture or osteotomy sites and TIMR regions, in order to identify risk factors for fracture. A total of 44 femora and 28 tibiae in 25 patients with a mean age of 5.0 years (1.9 to 10.5) at presentation were studied. There were six patients with Sillence type I, five with type III, 13 with type IV and one with type V osteogenesis imperfecta. All received bisphosphonate treatment at the same stage during the mean follow-up of 7.3 years (0.5 to 18.1). The fracture-free survival was estimated at 6.2 years (95% confidence interval 5.1 to 7.3) by Kaplan-Meier analysis. More than half the fracture or osteotomy sites remained in a less-remodelled state at the latest follow-up or time of fracture. Of the 33 fractures, 29 (87.9%) occurred in long bones containing a less-remodelled site, and these fractures were located at this site. The relative fracture risk at the rod tip was significantly greater than in any other TIMR region (p < 0.001), and this was higher in bone segments having a less-remodelled site.

This study shows a persistent fracture risk in TIMR-stabilised long bones, especially at less-remodelled fracture or osteotomy sites and at the rod tip.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 3 | Pages 378 - 384
1 Mar 2012
Tsutsumimoto T Shimogata M Yui M Ohta H Misawa H

We retrospectively examined the prevalence and natural history of asymptomatic lumbar canal stenosis in patients treated surgically for cervical compressive myelopathy in order to assess the influence of latent lumbar canal stenosis on the recovery after surgery. Of 214 patients who had undergone cervical laminoplasty for cervical myelopathy, we identified 69 (32%) with myelographically documented lumbar canal stenosis. Of these, 28 (13%) patients with symptomatic lumbar canal stenosis underwent simultaneous cervical and lumbar decompression. Of the remaining 41 (19%) patients with asymptomatic lumbar canal stenosis who underwent only cervical surgery, 39 were followed up for ≥ 1 year (mean 4.9 years (1 to 12)) and were included in the analysis (study group). Patients without myelographic evidence of lumbar canal stenosis, who had been followed up for ≥ 1 year after the cervical surgery, served as controls (135 patients; mean follow-up period 6.5 years (1 to 17)). Among the 39 patients with asymptomatic lumbar canal stenosis, seven had lumbar-related leg symptoms after the cervical surgery.

Kaplan–Meier analysis showed that 89.6% (95% confidence interval (CI) 75.3 to 96.0) and 76.7% (95% CI 53.7 to 90.3) of the patients with asymptomatic lumbar canal stenosis were free from leg symptoms for three and five years, respectively. There were no significant differences between the study and control groups in the recovery rate measured by the Japanese Orthopaedic Association score or improvement in the Nurick score at one year after surgery or at the final follow-up.

These results suggest that latent lumbar canal stenosis does not influence recovery following surgery for cervical myelopathy; moreover, prophylactic lumbar decompression does not appear to be warranted as a routine procedure for coexistent asymptomatic lumbar canal stenosis in patients with cervical myelopathy, when planning cervical surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 689 - 694
1 May 2011
Garrett BR Hoffman EB Carrara H

Distal femoral physeal fractures in children have a high incidence of physeal arrest, occurring in a mean of 40% of cases. The underlying nature of the distal femoral physis may be the primary cause, but other factors have been postulated to contribute to the formation of a physeal bar. The purpose of this study was to assess the significance of contributing factors to physeal bar formation, in particular the use of percutaneous pins across the physis.

We reviewed 55 patients with a median age of ten years (3 to 13), who had sustained displaced distal femoral physeal fractures. Most (40 of 55) were treated with percutaneous pinning after reduction, four were treated with screws and 11 with plaster. A total of 40 patients were assessed clinically and radiologically after skeletal maturity or at the time of formation of a bar. The remaining 15 were followed up for a minimum of two years.

Formation of a physeal bar occurred in 12 (21.8%) patients, with the rate rising to 30.6% in patients with high-energy injuries compared with 5.3% in those with low-energy injuries. There was a significant trend for physeal arrest according to increasing severity using the Salter-Harris classification. Percutaneous smooth pins across the physis were not statistically associated with growth arrest.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 4 | Pages 571 - 575
1 Apr 2010
Clint SA Morris TP Shaw OM Oddy MJ Rudge B Barry M

The databases of the Picture Archiving and Communication Systems of two hospitals were searched and all children who had a lateral radiograph of the ankle during their attendance at the emergency department were identified. In 227 radiographs, Bohler’s and Gissane’s angles were measured on two separate occasions and by two separate authors to allow calculation of inter- and intra-observer variation. Intraclass correlation coefficients were used to assess the reliability of the measurements.

For Bohler’s angle the overall inter-observer reliability, the intraclass correlation coefficient was 0.90 and the intra-observer reliability 0.95, giving excellent agreement. This reliability was maintained across the age groups. For Gissane’s angle, inter- and intra-observer reliability was only fair or poor across most age groups.

Further analysis of the Bohler’s angle showed a significant variation in the mean angle with age. Contrary to published opinion, the angle is not uniformly lower than that of adults but varies with age, peaking towards the end of the first decade before attaining adult values. The age-related radiologic changes presented here may help in the interpretation of injuries to the hindfoot in children.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 793 - 800
1 Jun 2011
Yalçin N Öztürk A Özkan Y Çelimli N Özocak E Erdogan A Sahin N Ilgezdi S

We studied the effects of hyperbaric oxygen (HBO) and zoledronic acid (ZA) on posterior lumbar fusion using a validated animal model. A total of 40 New Zealand white rabbits underwent posterior lumbar fusion at L5–6 with autogenous iliac bone grafting. They were divided randomly into four groups as follows: group 1, control; group 2, HBO (2.4 atm for two hours daily); group 3, local ZA (20 μg of ZA mixed with bone graft); and group 4, combined HBO and local ZA. All the animals were killed six weeks after surgery and the fusion segments were subjected to radiological analysis, manual palpation, biomechanical testing and histological examination.

Five rabbits died within two weeks of operation. Thus, 35 rabbits (eight in group 1 and nine in groups 2, 3 and 4) completed the study. The rates of fusion in groups 3 and 4 (p = 0.015) were higher than in group 1 (p < 0.001) in terms of radiological analysis and in group 4 was higher than in group 1 with regard to manual palpation (p = 0.015). We found a statistically significant difference in the biomechanical analysis between groups 1 and 4 (p = 0.024). Histological examination also showed a statistically significant difference between groups 1 and 4 (p = 0.036).

Our results suggest that local ZA combined with HBO may improve the success rate in posterior lumbar spinal fusion.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 4 | Pages 537 - 541
1 Apr 2011
Song WS Kong C Jeon D Cho WH Kim JR Lee S

The use of allografts for the treatment of bone tumours in children is limited by nonunion and the difficulty of finding a suitable graft. Furthermore, appositional growth can’t be expected of an allograft.

We used an overlapping allograft in 11 children, with a mean age of ten years (4 to 15), with a mean follow-up of 24.1 months (20 to 33). There were five intercalary and six intra-articular resections, and the tumours were in the femur in six cases and the humerus in five. Rates of union, times to union, remodelling patterns and allograft-associated complications were evaluated.

No allograft was removed due to a complication. Of the 16 junctional sites, 15 (94%) showed union at a mean of 3.1 months (2 to 5). Remodelling between host and allograft was seen at 14 junctions at a mean of five months (4 to 7). The mean Musculoskeletal Tumor Society score was 26.5 of 30 (88.3%). One case of nonunion and another with screw protrusion required re-operation.

Overlapping allografts have the potential to shorten time to union, decrease rates of nonunion and have positive appositional growth effect.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 4 | Pages 439 - 442
1 Apr 2011
Sexton SA Yeung E Jackson MP Rajaratnam S Martell JM Walter WL Zicat BA Walter WK

We investigated factors that were thought to be associated with an increased incidence of squeaking of ceramic-on-ceramic total hip replacements. Between June 1997 and December 2008 the three senior authors implanted 2406 primary total hip replacements with a ceramic-on-ceramic bearing surface. The mean follow-up was 10.6 years. The diagnosis was primary osteoarthritis in each case, and no patient had undergone previous surgery to the hip. We identified 74 squeaking hips (73 patients) giving an incidence of 3.1% at a mean follow-up of 9.5 years (4.1 to 13.3).

Taller, heavier and younger patients were significantly more likely to have hips that squeaked. Squeaking hips had a significantly higher range of post-operative internal (p = 0.001) and external rotation (p = 0.003) compared with silent hips. Patients with squeaking hips had significantly higher activity levels (p = 0.009). A squeaking hip was not associated with a significant difference in patient satisfaction (p = 0.24) or Harris hip score (p = 0.34). Four implant position factors enabled good prediction of squeaking. These were high acetabular component inclination, high femoral offset, lateralisation of the hip centre and either high or low acetabular component anteversion.

This is the largest study to date to examine patient factors and implant position factors that predispose to squeaking of a ceramic-on-ceramic hip. The results suggest that factors which increase the mechanical forces across the hip joint and factors which increase the risk of neck-to-rim impingement, and therefore edge-loading, are those that predispose to squeaking.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 738 - 745
1 Jun 2011
Davda K Lali FV Sampson B Skinner JA Hart AJ

We retrospectively analysed concentrations of chromium and cobalt ions in samples of synovial fluid and whole blood taken from a group of 92 patients with failed current-generation metal-on-metal hip replacements. We applied acid oxidative digestion to our trace metal analysis protocol, which found significantly higher levels of metal ion concentrations in blood and synovial fluid than a non-digestive method. Patients were subcategorised by mode of failure as either ‘unexplained pain’ or ‘defined causes’. Using this classification, chromium and cobalt ion levels were present over a wider range in synovial fluid and not as strongly correlated with blood ion levels as previously reported. There was no significant difference between metal ion concentrations and manufacturer of the implant, nor femoral head size below or above 50 mm. There was a moderately positive correlation between metal ion levels and acetabular component inclination angle as measured on three-dimensional CT imaging.

Our results suggest that acid digestion of samples of synovial fluid samples is necessary to determine metal ion concentrations accurately so that meaningful comparisons can be made between studies.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 367 - 373
1 Mar 2009
Allom R Colegate-Stone T Gee M Ismail M Sinha J

A consecutive series of 372 patients who underwent surgery for disorders of the rotator cuff involving arthroscopic subacromial decompression and open or arthroscopic repairs of the cuff were prospectively investigated as to the comparability of subjective and objective assessment scores of shoulder function. Assessments were made before operation and at 3, 6, 12, 18 and 24 months after surgery using the Disabilities of the Arm, Shoulder, and Hand score, the Oxford shoulder score and the Constant-Murley score, which was used as a reference. All scores were standardised to a scale of 0 to 100 for comparison. Statistical analysis compared the post-operative course and the mean score for the subjective Disabilities to the Arm, Shoulder and Hand score and Oxford shoulder score, with the objective Constant score at each interval. A strong correlation was evident between both subjective scores and the Constant score. We concluded that both the subjective scores would be useful substitutes for the Constant score, obviating the need for a trained investigator and the specialist equipment required to perform the Constant score.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 4 | Pages 470 - 475
1 Apr 2011
Kendrick BJL Simpson DJ Kaptein BL Valstar ER Gill HS Murray DW Price AJ

The Oxford unicompartmental knee replacement (UKR) was designed to minimise wear utilising a fully-congruent, mobile, polyethylene bearing. Wear of polyethylene is a significant cause of revision surgery in UKR in the first decade, and the incidence increases in the second decade. Our study used model-based radiostereometric analysis to measure the combined wear of the upper and lower bearing surfaces in 13 medial-compartment Oxford UKRs at a mean of 20.9 years (17.2 to 25.9) post-operatively.

The mean linear penetration of the polyethylene bearing was 1.04 mm (0.307 to 2.15), with a mean annual wear rate of 0.045 mm/year (0.016 to 0.099). The annual wear rate of the phase-2 bearings (mean 0.022 mm/year) was significantly less (p = 0.01) than that of phase-1 bearings (mean 0.07 mm/year).

The linear wear rate of the Oxford UKR remains very low into the third decade. We believe that phase-2 bearings had lower wear rates than phase-1 implants because of the improved bearing design and surgical technique which decreased the incidence of impingement. We conclude that the design of the Oxford UKR gives low rates of wear in the long term.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 3 | Pages 293 - 297
1 Mar 2011
Labek G Thaler M Janda W Agreiter M Stöckl B

In a systematic review, reports from national registers and clinical studies were identified and analysed with respect to revision rates after joint replacement, which were calculated as revisions per 100 observed component years.

After primary hip replacement, a mean of 1.29 revisions per 100 observed component years was seen. The results after primary total knee replacement are 1.26 revisions per 100 observed component years, and 1.53 after medial unicompartmental replacement. After total ankle replacement a mean of 3.29 revisions per 100 observed component years was seen.

The outcomes of total hip and knee replacement are almost identical. Revision rates of about 6% after five years and 12% after ten years are to be expected.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 3 | Pages 421 - 426
1 Mar 2011
Maličev E Barlič A Kregar-Velikonja N Stražar K Drobnič M

The aim of this study was to evaluate the cultivation potential of cartilage taken from the debrided edge of a chronic lesion of the articular surface. A total of 14 patients underwent arthroscopy of the knee for a chronic lesion on the femoral condyles or trochlea. In addition to the routine cartilage biopsy, a second biopsy of cartilage was taken from the edge of the lesion. The cells isolated from both sources underwent parallel cultivation as monolayer and three-dimensional (3D) alginate culture. The cell yield, viability, capacity for proliferation, morphology and the expressions of typical cartilage genes (collagen I, COL1; collagen II, COL2; aggrecan, AGR; and versican, VER) were assessed. The cartilage differentiation indices (COL2/COL1, AGR/VER) were calculated. The control biopsies revealed a higher mean cell yield (1346 cells/mg vs 341 cells/mg), but similar cell proliferation, viability and morphology compared with the cells from the edge of the lesion. The cartilage differentiation indices were superior in control cells: COL2/COL1 (threefold in biopsies (non-significant)); sixfold in monolayer cultures (p = 0.012), and 7.5-fold in hydrogels (non-significant), AGR/VER (sevenfold in biopsies (p = 0.04), threefold (p = 0.003) in primary cultures and 3.5-fold in hydrogels (non-significant)).

Our results suggest that the cultivation of chondrocytes solely from the edges of the lesion cannot be recommended for use in autologous chondrocyte implantation.