We retrospectively reviewed 60 fractures of the tibial plafond treated by either an ankle-sparing diaphyseal-epiphyseal technique using the Ilizarov ring fixator or by an ankle-spanning technique using a monolateral articulated external fixator. The Ilizarov ring fixator was applied in 24 fractures and the monolateral articulated transarticular external fixator in 20. Both techniques were combined with limited open reduction and internal fixation of the articular surface if necessary. Between three and nine years after the injury, all patients returned for clinical and radiological assessment and evaluation of ankle function using the modified Mazur score. There were no significant differences between the two groups in terms of age, gender, mechanism of injury, type of fracture or length of follow-up. The mean functional ankle score was 86 points for the Ilizarov group and 82 points for the articulated fixator group. The difference was not significant (p = 0.07). There were no significant differences between the groups with regard to the radiographic score and late complications. Patients treated with the Ilizarov ring fixator had significantly better ankle and subtalar
The different attributes of the Patient Evaluation Measure (PEM) questionnaire were investigated in 80 patients with a fracture of the scaphoid. Assessments were made at 2, 8, 12, 26 and 52 weeks. Reliability was assessed by measurement of the internal consistency of the different questions in 275 completed PEM forms. Cronbach’s alpha, which needs to lie between 0.7 and 0.9, was 0.9 for the PEM. Pain, tenderness, swelling, wrist
The β-angle is a radiological tool for measuring the distance between the pathological head-neck junction and the acetabular rim with the hip in 90° of flexion in patients with femoroacetabular impingement. Initially it was measured using an open-chamber MRI. We have developed a technique to measure this angle on plain radiographs. Correlation analysis was undertaken to determine the relationship between the range of
Cementless acetabular components rely on press-fit fixation for initial stability. In certain cases, initial stability is more difficult to obtain (such as during revision). No current study evaluates how a surgeon’s impaction technique (mallet mass, mallet velocity, and number of strikes) may affect component fixation. This study seeks to answer the following research questions: 1) how does impaction technique affect a) bone strain generation and deterioration (and hence implant stability) and b) seating in different density bones?; and 2) can an impaction technique be recommended to minimize risk of implant loosening while ensuring seating of the acetabular component? A custom drop tower was used to simulate surgical strikes seating acetabular components into synthetic bone. Strike velocity and drop mass were varied. Synthetic bone strain was measured using strain gauges and stability was assessed via push-out tests. Polar gap was measured using optical trackers.Aims
Methods
1. Two hundred and seventeen low-friction arthroplasties performed between November 1962 and April 1969 in 203 patients with failed previous operations have been analysed. 2. The technical details of operation in relation to these conversion problems have been outlined. 3. The quality of the results in relation to pain, mobility and ability to walk has been assessed before operation and one year afterwards, with small numbers at three and five years. 4. Pain was completely relieved or was minimal in 96·3 per cent of the patients, and in no case was the pain worse. 5. The total range of
1. The customary method of broaching and of knocking the prosthesis down into the neck of the femur produces an indeterminate interference fit. 2. The usual interference fit may suffer progressive breakdown under even small, steady loads. This results in a permanent relative
1. A study of the late results of 343 soundly united tibial shaft fractures was carried out. Limitation of ankle and/or foot
Some surgeons are reluctant to perform a reverse
total shoulder arthroplasty (RTSA) on both shoulders because of concerns
regarding difficulty with activities of daily living post-operatively
as a result of limited rotation of the shoulders. Nevertheless,
we hypothesised that outcomes and patient satisfaction following
bilateral RTSA would be comparable to those following unilateral
RTSA. A single-surgeon RTSA registry was reviewed for patients who underwent
bilateral staged RTSA with a minimum follow-up of two years. A unilateral
RTSA matched control was selected for each shoulder in those patients
undergoing bilateral procedures. The Constant–Murley score (CMS), American
Shoulder and Elbow Surgeons (ASES) score, Subjective Shoulder Values
(SSV), visual analogue scale (VAS) for pain, range of
Before proceeding to longer-term studies, we have studied the early clinical results of a new mobile-bearing total knee prosthesis in comparison with an established fixed-bearing device. Patients requiring bilateral knee replacement consented to have their operations under one anaesthetic using one of each prosthesis. They also agreed to accept the random choice of knee (right or left) and to remain ignorant as to which side had which implant. Outcomes were measured using the American Knee Society Score (AKSS), the Oxford Knee Score (OKS), and determination of the range of
Gunshot injuries to the shoulder are rare and
difficult to manage. We present a case series of seven patients
who sustained a severe shoulder injury to the non-dominant side
as a result of a self-inflicted gunshot wound. We describe the injury
as ‘suicide shoulder’ caused by upward and outward
We have reviewed 81 patients with fractures of the odontoid process treated between May 1983 and July 1997, by anterior screw fixation. There were 29 patients with Anderson and D’Alonzo type-II fractures and 52 with type III. Roy-Camille’s classification identified the direction and instability of the fracture. Operative fixation was carried out on 48 men and 33 women with a mean age of 57 years. Associated injuries of the cervical spine were present in 15 patients, neurological signs in 13, and 18 had an Injury Severity Score of more than 15. Nine patients died and 11 were lost to follow-up. Of 61 patients, 56 (92%) achieved bony union at an average of 14.1 weeks. Two patients required a secondary posterior fusion after failure of the index operation. A full range of
Of 44 patients (55 hips) with slipped upper femoral epiphysis treated from 1963 to 1989, 13 (14 hips) developed chondrolysis. Eight hips had chondrolysis at the time of presentation, all in female patients who were either coloured or black and who had moderate or severe slips. The other six hips had persistent pin penetration of the joint; in five of these the pin penetrated the anterosuperior quadrant of the head. Removal of penetrating pins resulted in improvement in pain in all six hips and in the range of
Lumbar spondylolysis is a stress fracture of the pars interarticularis. We have evaluated the site of origin of the fracture clinically and biomechanically. Ten adolescents with incomplete stress fractures of the pars (four bilateral) were included in our study. There were seven boys and three girls aged between 11 and 17 years. The site of the fracture was confirmed by axial and sagittal reconstructed CT. The maximum principal tensile stresses and their locations in the L5 pars during lumbar
Forty patients with acute complete rupture of the calcaneal tendon were managed conservatively and randomly allocated to treatment groups using either cast immobilisation for eight weeks, or cast immobilisation for three weeks, followed by controlled early mobilisation in a Sheffield splint. The splint is an ankle-foot orthosis which holds the ankle in 15 degrees of plantar flexion, but allows some
Fractures of the scaphoid are most common in young men; immobilisation in a cast usually means a long period away from work and athletic activities. Early rigid fixation has been shown to promote a rapid functional recovery, but open reduction and internal fixation is technically demanding with the dangers of damage to the radiocarpal ligaments, the scaphotrapezial joint, and the blood supply of the scaphoid. For minimally displaced or undisplaced B1 or B2 fractures, these problems can be overcome by percutaneous fixation. We report our technique and the results of a pilot study in 15 patients. There was no immobilisation; patients were allowed
The results of 63 operative repairs of chronic tears of the rotator cuff in 61 patients are reviewed retrospectively; the mean follow-up was 32.7 months. Fifty-four patients presented with symptoms of persistent pain and seven patients with gross loss of
Our aim was to determine the effect of the initial pattern of fracture and the displacement of fragments on the outcome of proximal humeral fractures treated conservatively. We followed 93 consecutive patients prospectively for one year. Final
1. Tendon grafts, in order to survive, have to develop a blood supply from their immediate environment. This causes adhesions. 2. Their final range of
We report the clinical and radiological outcome of total ankle replacement performed in conjunction with hindfoot fusion or in isolation. Between May 2003 and June 2008, 60 ankles were treated with total ankle replacement with either subtalar or triple fusion, and the results were compared with a control group of 288 ankles treated with total ankle replacement alone. After the mean follow-up of 39.5 months (12 to 73), the ankles with hindfoot fusion showed significant improvement in the mean visual analogue score for pain (p <
0.001), the mean American Orthopaedic Foot and Ankle Society score (p <
0.001), and the mean of a modified version of this score (p <
0.001). The mean visual analogue pain score (p = 0.304) and mean modified American Orthopaedic Foot and Ankle Society score (p = 0.119) were not significantly different between the hindfoot fusion and the control groups. However, the hindfoot fusion group had a significantly lower mean range of