Advertisement for orthosearch.org.uk
Results 681 - 700 of 1504
Results per page:
Bone & Joint 360
Vol. 9, Issue 1 | Pages 4 - 9
1 Feb 2020
Logishetty K Muirhead-Allwood SK Cobb JP


Bone & Joint Research
Vol. 3, Issue 6 | Pages 183 - 186
1 Jun 2014
Wyatt MC Jesani S Frampton C Devane P Horne JG

Objectives. Our study aimed to examine not only the incidence but also the impact of noise from two types of total hip replacement articulations: ceramic-on-ceramic and ceramic-on-polyethylene. . Methods . We performed a case-controlled study comparing subjective and objective questionnaire scores of patients receiving a ceramic-on-ceramic or a ceramic-on-polyethylene total hip replacement by a single surgeon. Results. There was a threefold higher incidence of noise from patients in the ceramic-on-ceramic group compared with the control group. The impact of this noise was significant for patients both subjectively and objectively. Conclusions. This study reports a high patient impact of noise from ceramic-on-ceramic total hip replacements. This has led to a change in practice by the principal author. Cite this article: Bone Joint Res 2014;3:183–6


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 9 | Pages 1227 - 1230
1 Sep 2010
Gregory JJ Starks I Aulakh T Phillips SJ

Between January 2000 and December 2007, 31 patients 90 years of age or older underwent total hip replacement at our hospital. Their data were collected prospectively. The rate of major medical complications was 9%. The surgical re-operation rate was 3%. The requirement for blood transfusion was 71% which was much higher than for younger patients. The 30-day, one-year and current mortality figures were 6.4% (2 of 31), 9.6% (3 of 31) and 55% (17 of 31), respectively, with a mean follow-up for the 14 surviving patients of six years. Cox’s regression analysis revealed no significant independent predictors of mortality. Only 52% of patients returned immediately to their normal abode, with 45% requiring a prolonged period of rehabilitation. This is the first series to assess survival five years after total hip replacement for patients in their 90th year and beyond. Hip replacement in the extreme elderly should not be discounted on the grounds of age alone, although the complication rate exceeds that for younger patients. It can be anticipated that almost half of the patients will survive five years after surgery


Bone & Joint 360
Vol. 8, Issue 6 | Pages 12 - 15
1 Dec 2019


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 401 - 402
1 Apr 2020
Chang JS Haddad FS


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 66 - 69
1 Nov 2014
Lombardi Jr AV Berend KR Adams JB

The common recommended treatment for infected total hip replacement is two-staged exchange including removal of all components. However, removal of well-fixed femoral stems can result in structural bone damage. We recently reported on an alternative treatment of partial two-stage exchange used in selected cases, in which a well-fixed femoral stem was left and only the acetabular component removed, the joint space was debrided thoroughly, an antibiotic-laden polymethylmethacrylate spacer was moulded using a bulb-type syringe and placed in the acetabulum, intravenous antibiotics were administered during the interval, and delayed re-implantation was performed. In 19 patients treated with this technique from January 2000 to January 2011, 89% were free of infection at a mean follow-up of four years (2 to 11). Since then, disposable silicone moulds have become available to fabricate spacers in separate femoral and head units. The head spacer mould, which incorporates various neck taper adapter options, greatly facilitates the technique of partial two-stage exchange. We report our early experience using disposable silicone head spacer moulds for partial two-stage exchange in seven patients with infected primary hip replacements. Cite this article: Bone Joint J 2014;96-B(11 Suppl A):66–9


Bone & Joint 360
Vol. 9, Issue 2 | Pages 43 - 44
1 Apr 2020


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 181 - 187
1 Feb 2014
Owen DH Russell NC Smith PN Walter WL

Squeaking arising from a ceramic-on-ceramic (CoC) total hip replacement (THR) may cause patient concern and in some cases causes patients to seek revision surgery. We performed a meta-analysis to determine the incidence of squeaking and the incidence of revision surgery for squeaking. A total of 43 studies including 16 828 CoC THR that reported squeaking, or revision for squeaking, were entered into the analysis. The incidence of squeaking was 4.2% and the incidence of revision for squeaking was 0.2%. The incidence of squeaking in patients receiving the Accolade femoral stem was 8.3%, and the incidence of revision for squeaking in these patients was 1.3%. Cite this article: Bone Joint J 2014;96-B:181–7


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 94 - 99
1 Jan 2015
Grammatopoulos G Wilson HA Kendrick BJL Pulford EC Lippett J Deakin M Andrade AJ Kambouroglou G

National Institute of Clinical Excellence guidelines state that cemented stems with an Orthopaedic Data Evaluation Panel (ODEP) rating of > 3B should be used for hemiarthroplasty when treating an intracapsular fracture of the femoral neck. These recommendations are based on studies in which most, if not all stems, did not hold such a rating. . This case-control study compared the outcome of hemiarthroplasty using a cemented (Exeter) or uncemented (Corail) femoral stem. These are the two prostheses most commonly used in hip arthroplasty in the UK. Data were obtained from two centres; most patients had undergone hemiarthroplasty using a cemented Exeter stem (n = 292/412). Patients were matched for all factors that have been shown to influence mortality after an intracapsular fracture of the neck of the femur. Outcome measures included: complications, re-operations and mortality rates at two, seven, 30 and 365 days post-operatively. Comparable outcomes for the two stems were seen. . There were more intra-operative complications in the uncemented group (13% vs 0%), but the cemented group had a greater mortality in the early post-operative period (n = 6). There was no overall difference in the rate of re-operation (5%) or death (365 days: 26%) between the two groups at any time post-operatively. This study therefore supports the use of both cemented and uncemented stems of proven design, with an ODEP rating of 10A, in patients with an intracapsular fracture of the neck of the femur. Cite this article: Bone Joint J 2015;97-B:94–9


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 32 - 35
1 Nov 2014
Mirza AJ Lombardi Jr AV Morris MJ Berend KR

Direct anterior approaches to the hip have gained popularity as a minimally invasive method when performing primary total hip replacement (THR). A retrospective review of a single institution joint registry was performed in order to compare patient outcomes after THR using the Anterior Supine Intermuscular (ASI) approach versus a more conventional direct lateral approach. An electronic database identified 1511 patients treated with 1690 primary THRs between January 2006 and December 2010. Our results represent a summary of findings from our previously published work. We found that patients that underwent an ASI approach had faster functional recovery and higher Harris hip scores in the early post-operative period when compared with patients who had a direct lateral approach The overall complication rate in our ASI group was relatively low (1.7%) compared with other series using the same approach. The most frequent complication was early periprosthetic femoral fractures (0.9%). The dislocation rate in our series was 0.4% and the prosthetic joint infection rate was 0.1%. We suggest that the ASI approach is acceptable and safe when performing THR and encourages early functional recovery of our patients. Cite this article: Bone Joint J 2014;96- B(11 Suppl A):32–5


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1455 - 1458
1 Nov 2014
Amanatullah DF Rachala SR Trousdale RT Sierra RJ

Dysplasia of the hip, hypotonia, osteopenia, ligamentous laxity, and mental retardation increase the complexity of performing and managing patients with Down syndrome who require total hip replacement (THR). We identified 14 patients (six males, eight females, 21 hips) with Down syndrome and degenerative disease of the hip who underwent THR, with a minimum follow-up of two years from 1969 to 2009. In seven patients, bilateral THRs were performed while the rest had unilateral THRs. The mean clinical follow-up was 5.8 years (standard deviation (. sd. ) 4.7; 2 to 17). The mean Harris hip score was 37.9 points (. sd. 7.8) pre-operatively and increased to 89.2 (. sd. 12.3) at final follow-up (p = 1x10. -9. ). No patient suffered a post-operative dislocation. In three patients, four hips had revision THR for aseptic loosening at a mean follow-up of 7.7 years (. sd. 6.3; 3 to 17). This rate of revision THR was higher than expected. Our patients with Down syndrome benefitted clinically from THR at mid-term follow-up. Cite this article: Bone Joint J 2014;96-B:1455–8


Bone & Joint 360
Vol. 9, Issue 2 | Pages 46 - 48
1 Apr 2020
Evans JT Whitehouse MR


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 593 - 600
1 May 2011
Kuzyk PRT Saccone M Sprague S Simunovic N Bhandari M Schemitsch EH

We conducted a systematic review and meta-analysis of randomised controlled trials comparing cross-linked with conventional polyethylene liners for total hip replacement in order to determine whether these liners reduce rates of wear, radiological evidence of osteolysis and the need for revision. The MEDLINE, EMBASE and COCHRANE databases were searched from their inception to May 2010 for all trials involving the use of cross-linked polyethylene in total hip replacement. Eligibility for inclusion in the review included the random allocation of treatments, the use of cross-linked and conventional polyethylene, and radiological wear as an outcome measure. The pooled mean differences were calculated for bedding-in, linear wear rate, three-dimensional linear wear rate, volumetric wear rate and total linear wear. Pooled risk ratios were calculated for radiological osteolysis and revision hip replacement. A search of the literature identified 194 potential studies, of which 12 met the inclusion criteria. All reported a significant reduction in radiological wear for cross-linked polyethylene. The pooled mean differences for linear rate of wear, three-dimensional linear rate of wear, volumetric wear rate and total linear wear were all significantly reduced for cross-linked polyethylene. The risk ratio for radiological osteolysis was 0.40 (95% confidence interval 0.27 to 0.58; I. 2. = 0%), favouring cross-linked polyethylene. The follow-up was not long enough to show a difference in the need for revision surgery


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1155 - 1157
1 Sep 2007
Suzuki K Kawachi S Matsubara M Morita S Jinno T Shinomiya K

We present a series of 30 uncemented total hip replacements performed between June 1985 and January 2002 with a mean follow-up of seven years (5 to 20) in 27 patients who had previously undergone a valgus intertrochanteric osteotomy. No further osteotomy was undertaken to enable hip replacement. We used a number of uncemented modular or monoblock femoral components, acetabular components and bearings. The patients were followed up clinically and radiologically. We report 100% survival of the femoral component. One acetabular component was revised at five years post-implantation for aseptic loosening. We noted cortical hypertrophy around the tip of the monoblock stems in six patients. We believe that modular femoral components should be used when undertaking total hip replacement in patients who have previously undergone valgus femoral osteotomy


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 524 - 529
1 Apr 2020
Jamshidi K Mirkazemi M Gharedaghi M Izanloo A Mohammadpour M Pisoudeh K Bagherifard A Mirzaei A

Aims

The consensus is that bipolar hemiarthroplasty (BHA) in allograft-prosthesis composite (APC) reconstruction of the proximal femur following primary tumour resection provides more stability than total hip arthroplasty (THA). However, no comparative study has been performed. In this study, we have compared the outcome and complication rates of these two methods.

Methods

In a retrospective study, 57 patients who underwent APC reconstruction of proximal femur following the primary tumour resection, either using BHA (29) or THA (28), were included. Functional outcome was assessed using the Musculoskeletal Tumour Society (MSTS) scoring system and Harris Hip Score (HHS). Postoperative complications of the two techniques were also compared.


Bone & Joint 360
Vol. 9, Issue 2 | Pages 33 - 37
1 Apr 2020


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1423 - 1430
1 Nov 2019
Wiik AV Lambkin R Cobb JP

Aims

The aim of this study was to assess the functional gain achieved following hip resurfacing arthroplasty (HRA).

Patients and Methods

A total of 28 patients (23 male, five female; mean age, 56 years (25 to 73)) awaiting Birmingham HRA volunteered for this prospective gait study, with an age-matched control group of 26 healthy adults (16 male, ten female; mean age, 56 years (33 to 84)). The Oxford Hip Score (OHS) and gait analysis using an instrumented treadmill were used preoperatively and more than two years postoperatively to measure the functional change attributable to the intervention.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 120 - 122
1 Jan 2006
Kwong FNK Power RA

The outcome of a cemented hip arthroplasty is partly dependent on the type of cement which is used. The production of an interface gap between the stem and the cement mantle as a result of shrinkage of the cement, may be a factor involved. Palacos R, Palacos LV (both with gentamicin), CMW 1, CMW 2, CMW Endurance (CMWE) and Simplex were prepared under vacuum and allowed to cure overnight in similar cylinders. The next day this volume was determined by the displacement of water. Shrinkage varied between 3.82% and 7.08% with CMWE having the lowest and Palacos LV the highest. This could be a factor to consider when choosing a cement for a shape-closed stem


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 26 - 31
1 Nov 2012
Mayle RE Della Valle CJ

The purpose of this paper is to discuss the risk factors, prevention strategies, classification, and treatment of intra-operative femur fractures sustained during primary and revision total hip arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 12 - 19
1 Jan 2010
Vendittoli P Roy A Mottard S Girard J Lusignan D Lavigne M

We have updated our previous randomised controlled trial comparing release of chromium (Cr) and cobalt (Co) ions and included levels of titanium (Ti) ions. We have compared the findings from 28 mm metal-on-metal total hip replacement, performed using titanium CLS/Spotorno femoral components and titanium AlloFit acetabular components with Metasul bearings, with Durom hip resurfacing using a Metasul articulation or bearing and a titanium plasma-sprayed coating for fixation of the acetabular component. Although significantly higher blood ion levels of Cr and Co were observed at three months in the resurfaced group than in total hip replacement, no significant difference was found at two years post-operatively for Cr, 1.58 μg/L and 1.62 μg/L respectively (p = 0.819) and for Co, 0.67 μg/L and 0.94 μg/L respectively (p = 0.207). A steady state was reached at one year in the resurfaced group and after three months in the total hip replacement group. Interestingly, Ti, which is not part of the bearing surfaces with its release resulting from metal corrosion, had significantly elevated ion levels after implantation in both groups. The hip resurfacing group had significantly higher Ti levels than the total hip replacement group for all periods of follow-up. At two years the mean blood levels of Ti ions were 1.87 μg/L in hip resurfacing and and 1.30 μg/L in total hip replacement (p = 0.001). The study confirms even with different bearing diameters and clearances, hip replacement and 28 mm metal-on-metal total hip replacement produced similar Cr and Co metal ion levels in this randomised controlled trial study design, but apart from wear on bearing surfaces, passive corrosion of exposed metallic surfaces is a factor which influences ion concentrations. Ti plasma spray coating the acetabular components for hip resurfacing produces significantly higher release of Ti than Ti grit-blasted surfaces in total hip replacement