Advertisement for orthosearch.org.uk
Results 661 - 680 of 776
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 12 | Pages 1613 - 1617
1 Dec 2006
Karunakar MA Sen A Bosse MJ Sims SH Goulet JA Kellam JF

Our study was designed to compare the effect of indometacin with that of a placebo in reducing the incidence of heterotopic ossification in a prospective, randomised trial. A total of 121 patients with displaced fractures of the acetabulum treated by operation through a Kocher-Langenbeck approach was randomised to receive either indometacin (75 mg) sustained release, or a placebo once daily for six weeks. The extent of heterotopic ossification was evaluated on plain radiographs three months after operation. Significant ossification of Brooker grade III to IV occurred in nine of 59 patients (15.2%) in the indometacin group and 12 of 62 (19.4%) receiving the placebo.

We were unable to demonstrate a statistically significant reduction in the incidence of severe heterotopic ossification with the use of indometacin when compared with a placebo (p = 0.722). Based on these results we cannot recommend the routine use of indometacin for prophylaxis against heterotopic ossification after isolated fractures of the acetabulum.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 215 - 221
1 Feb 2007
Krieg AH Hefti F

We evaluated 31 patients who were treated with a non-vascularised fibular graft after resection of primary musculoskeletal tumours, with a median follow-up of 5.6 years (3 to 26.7 years). Primary union was achieved in 89% (41 of 46) of the grafts in a median period of 24 weeks. All 25 grafts in 18 patients without additional chemotheraphy and/or radiotherapy achieved primary union, compared with 16 of the 21 grafts (76%; 13 patients) with additional therapy (p = 0.017). Radiographs showed an increase in diameter in 70% (59) of the grafts. There were seven fatigue fractures in six patients, but only two needed treatment.

Non-vascularised fibular transfer is a simpler, less expensive and a shorter procedure than the use of vascularised grafts and allows remodelling of the fibula at the donor site. It is a biological reconstruction with good long-term results, and a relatively low donor site complication rate of 16%.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 5 | Pages 686 - 692
1 May 2007
Bolland BJRF New AMR Madabhushi SPG Oreffo ROC Dunlop DG

The complications of impaction bone grafting in revision hip replacement includes fracture of the femur and subsidence of the prosthesis. In this in vitro study we aimed to investigate whether the use of vibration, combined with a perforated tamp during the compaction of morsellised allograft would reduce peak loads and hoop strains in the femur as a surrogate marker of the risk of fracture and whether it would also improve graft compaction and prosthetic stability.

We found that the peak loads and hoop strains transmitted to the femoral cortex during graft compaction and subsidence of the stem in subsequent mechanical testing were reduced. This innovative technique has the potential to reduce the risk of intra-operative fracture and to improve graft compaction and therefore prosthetic stability.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 8 | Pages 1104 - 1110
1 Aug 2011
Ji T Guo W Yang R Tang S Sun X

We set out to determine the impact of surgery on quality of life and function in patients who had undergone surgery for symptomatic peri-acetabular metastases. From a prospective database we retrospectively reviewed 46 consecutive patients who had been treated operatively between June 2003 and June 2009. The mean age of the patients was 56.4 years (20 to 73) and the mean post-operative follow-up was 19.2 months (4 to 70). Functional evaluation and quality-of-life assessments were performed. At the most recent follow-up, 26 patients (56.5%) were alive. Their median survival time was 25.0 months. Ten major postoperative complications had occurred in eight patients (17.4%). The mean post-operative Musculoskeletal Tumor Society score (MSTS 93) was 56.3% (6.7% to 90.0%). Improvement in the Eastern Cooperative Oncology Group (ECOG) performance status was seen in 32 patients (69.6%). On the European Organisation for Research and Treatment of Cancer core quality-of-life questionnaire (QLQ-C30) measure of global health status there was a statistically significant improvement from the patients’ pre-operative status (42.8 (sd 13.7)) to that found at the latest follow-up (58.0 (sd 12.5)) (p = 0.001). The only statistically significant change in the nine symptom domains of the QLQ-C30 was a reduction in the mean level of pain (from 59.1 to 29.5 (out of 100)) (p < 0.001).

Surgery for patients with peri-acetabular metastases reduces pain and improves their quality of life, and has a low rate of surgical complications.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 928 - 932
1 Jul 2006
Patil S Montgomery R

We reviewed 78 femoral and tibial nonunions treated between January 1992 and December 2003. Of these, we classified 41 in 40 patients as complex cases because of infection (22), bone loss (6) or failed previous surgery (13). The complex cases were all treated with Ilizarov frames. At a mean time of 14.1 months (4 to 38), 39 had healed successfully.

Using the Association for the Study and Application of the Methods of Ilizarov scoring system we obtained 17 excellent, 14 good, four fair and six poor bone results. The functional results were excellent in 14 patients, good in 14, fair in two and poor in two. A total of six patients were lost to follow-up and two had amputations so were not evaluated for final functional assessment. All but two patients were very satisfied with the results. The average cost of treatment to the treating hospital was approximately £30 000 per patient.

We suggest that early referral to a tertiary centre could reduce the morbidity and prolonged time off work for these patients. The results justify the expense, but the National Health Service needs to make financial provision for the reconstruction of this type of complex nonunion.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 928 - 933
1 Jul 2005
Berli BJ Schäfer D Morscher EW

The Morscher-Spotorno (MS-30) femoral stem is a stainless-steel, straight, three-dimensionally tapered, collarless implant for cemented fixation in total hip replacement.

We report the results at ten years of a consecutive series of 124 total hip replacements in 121 patients with the matt-surfaced MS-30 stem and an alumina ceramic head of 28-mm diameter. All the stems were fixed with Palacos bone cement with gentamicin using a modern cementing technique. They were combined with an uncemented, press-fit cup. The mean period of observation was 10.2 years (8.3 to 12.1) and no patient was lost to follow-up. Twenty-seven patients (22%) died with the implant in situ. Nine could only be interviewed by telephone. We included 85 patients with 88 hips in the clinical and radiological follow-up examinations.

None of the stems or cups had been revised. The Harris hip score was excellent or good in 97% (85 hips) and moderate in 3% (three hips). Radiologically, six hips (6.8%) had osteolysis adjacent to the stem, mostly in Gruen zone 7. Twenty (22.7%) showed one or more radiolucent lines. Twenty-two stems (25%) had subsided by 2 mm to 5 mm. In these cases two showed osteolysis (9.1%) with subsidence and four without (6.1%). Radiolucent lines were seen in seven with migration (31.8%) and in 13 without (19.7%). No infections and no acetabular osteolysis were observed.

The clinical results were excellent with survivorship after ten years of 100% and only a slightly statistically non-significant higher rate of osteolysis and radiolucency in cases of subsidence.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 601 - 607
1 May 2011
Hartofilakidis G Babis GC Georgiades G Kourlaba G

We studied the effect of trochanteric osteotomy in 192 total hip replacements in 140 patients with congenital hip disease. There was bony union in 158 hips (82%), fibrous union in 29 (15%) and nonunion in five (3%). The rate of union had a statistically significant relationship with the position of reattachment of the trochanter, which depended greatly on the pre-operative diagnosis. The pre-operative Trendelenburg gait substantially improved in all three disease types (dysplasia, low and high dislocation) and all four categories of reattachment position. A persistent Trendelenburg gait post-operatively was noticed mostly in patients with defective union (fibrous or nonunion). Acetabular and femoral loosening had a statistically significant relationship with defective union and the position of reattachment of the trochanter.

These results suggest that the complications of trochanteric osteotomy in total hip replacement for patients with congenital hip disease are less important than the benefits of this surgical approach.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1286 - 1292
1 Oct 2006
McLaughlin JR Lee KR

We studied a consecutive series of 285 uncemented total hip replacements in 260 patients using the Taperloc femoral component and the T-Tap acetabular component. The outcome of every hip was determined in both living and deceased patients. A complete clinical and radiological follow-up was obtained for 209 hips in 188 living patients, followed for a mean of 14.5 years (10 to 18.9). They were divided into two groups, obese and non-obese, as determined by their body mass index. There were 100 total hip replacements in 89 patients in the obese cohort (body mass index ≥ 30 kg/m2), and 109 in 99 non-obese (body mass index < 30 kg/m2) patients. A subgroup analysis of 31 patients of normal weight (body mass index 20 kg/m2 to 25 kg/m2) (33 hips) and 26 morbidly obese patients (body mass index ≥ 35 kg/m2) (30 hips) was also carried out.

In the obese group five femoral components (5%) were revised and one (1%) was loose by radiological criteria. Femoral cortical osteolysis was seen in eight hips (8%). The acetabular component was revised in 57 hips (57%) and a further 17 (17%) were loose. The mean Harris hip score improved from 52 (30 to 66) pre-operatively to 89 (49 to 100) at final follow-up. Peri-operative complications occurred in seven patients (7%).

In the non-obese group six (6%) femoral components were revised and one (1%) was loose. Femoral cortical osteolysis occurred in six hips (6%). The acetabular component was revised in 72 hips (66%) and a further 18 (17%) were loose. The mean Harris hip score increased from 53 (25 to 73) prior to surgery to 89 (53 to 100) at the time of each patient’s final follow-up radiograph.

No statistically significant difference was identified between the obese and non-obese patients with regards to clinical and radiological outcome or complications. The subgroup analysis of patients of normal weight and those who were morbidly obese showed no statistically significant difference in the rate of revision of either component.

Our findings suggest there is no evidence to support withholding total hip replacement from obese patients with arthritic hips on the grounds that their outcome will be less satisfactory than those who are not obese.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 832 - 836
1 Jun 2006
Barker R Takahashi T Toms A Gregson P Kuiper JH

The use of impaction bone grafting during revision arthroplasty of the hip in the presence of cortical defects has a high risk of post-operative fracture. Our laboratory study addressed the effect of extramedullary augmentation and length of femoral stem on the initial stability of the prosthesis and the risk of fracture.

Cortical defects in plastic femora were repaired using either surgical mesh without extramedullary augmentation, mesh with a strut graft or mesh with a plate. After bone impaction, standard or long-stem Exeter prostheses were inserted, which were tested by cyclical loading while measuring defect strain and migration of the stem.

Compared with standard stems without extramedullary augmentation, defect strains were 31% lower with longer stems, 43% lower with a plate and 50% lower with a strut graft. Combining extramedullary augmentation with a long stem showed little additional benefit (p = 0.67). The type of repair did not affect the initial stability. Our results support the use of impaction bone grafting and extramedullary augmentation of diaphyseal defects after mesh containment.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 4 | Pages 455 - 459
1 Apr 2006
Shetty NR Hamer AJ Kerry RM Stockley I Eastell R Wilkinson JM

The aims of this study were to examine the repeatability of measurements of bone mineral density (BMD) around a cemented polyethylene Charnley acetabular component using dual-energy x-ray absorptiometry and to determine the longitudinal pattern of change in BMD during the first 24 months after surgery.

The precision of measurements of BMD in 19 subjects ranged from 7.7% to 10.8% between regions, using a four-region-of-interest model. A longitudinal study of 27 patients demonstrated a transient decrease in net pelvic BMD during the first 12 months, which recovered to baseline at 24 months. The BMD in the region medial to the dome of the component reduced by between 7% and 10% during the first three months, but recovered to approximately baseline values by two years.

Changes in BMD in the pelvis around cemented acetabular components may be measured using dual-energy x-ray absorptiometry. Bone loss after insertion of a cemented Charnley acetabular component is small, transient and occurs mainly at the medial wall of the acetabulum. After two years, bone mass returns to baseline values, with a pattern suggesting a uniform transmission of load to the acetabulum.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 3 | Pages 315 - 320
1 Mar 2006
Field RE Singh PJ Latif AMH Cronin MD Matthews DJ

We describe the results at five years of a prospective study of a new tri-tapered polished, cannulated, cemented femoral stem implanted in 51 patients (54 hips) with osteoarthritis. The mean age and body mass index of the patients was 74 years and 27.9, respectively. Using the anterolateral approach, half of the stems were implanted by a consultant orthopaedic surgeon and half by six different registrars. There were three withdrawals from the study because of psychiatric illness, a deep infection and a recurrent dislocation. Five deaths occurred prior to five-year follow-up and one patient withdrew from clinical review.

In the remaining 51 hips the mean pre-operative Oxford hip score was 47 points which decreased to 19 points at five years (45 hips). Of the stems 49 (98%) were implanted within 1° of neutral in the femoral canal. The mean migration of the stem at five years was 1.9 mm and the survivorship for aseptic loosening was 100%. There was no significant difference in outcome between the consultant and registrar groups. At five years, the results were comparable with those of other polished, tapered, cemented stems. Long-term surveillance continues.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 658 - 664
1 May 2011
Karantana A Boulton C Bouliotis G Shu KSS Scammell BE Moran CG

We examined prospectively collected data from 6782 consecutive hip fractures and identified 327 fractures in 315 women aged ≤65 years. We report on their demographic characteristics, treatment and outcome and compare them with a cohort of 4810 hip fractures in 4542 women aged > 65 years.

The first significant increase in age-related incidence of hip fracture was at 45, rather than 50, which is when screening by the osteoporosis service starts in most health areas. Hip fractures in younger women are sustained by a population at risk as a result of underlying disease. Mortality of younger women with hip fracture was 46 times the background mortality of the female population. Smoking had a strong influence on the relative risk of ‘early’ (≤ 65 years of age) fracture.

Lag screw fixation was the most common method of operative treatment. General complication rates were low, as were re-operation rates for cemented prostheses. Kaplan-Meier implant survivorship of displaced intracapsular fractures treated by reduction and lag screw fixation was 71% (95% confidence interval 56 to 81) at five years. The best form of treatment remains controversial.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 12 | Pages 1557 - 1566
1 Dec 2006
Khanduja V Villar RN

This review describes the development of arthroscopy of the hip over the past 15 years with reference to patient assessment and selection, the technique, the conditions for which it is likely to prove useful, the contraindications and complications related to the procedure and, finally, to discuss possible developments in the future.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 8 | Pages 1033 - 1044
1 Aug 2011
Periasamy K Watson WS Mohammed A Murray H Walker B Patil S Meek RMD

The ideal acetabular component is characterised by reliable, long-term fixation with physiological loading of bone and a low rate of wear. Trabecular metal is a porous construct of tantalum which promotes bony ingrowth, has a modulus of elasticity similar to that of cancellous bone, and should be an excellent material for fixation.

Between 2004 and 2006, 55 patients were randomised to receive either a cemented polyethylene or a monobloc trabecular metal acetabular component with a polyethylene articular surface. We measured the peri-prosthetic bone density around the acetabular components for up to two years using dual-energy x-ray absorptiometry.

We found evidence that the cemented acetabular component loaded the acetabular bone centromedially whereas the trabecular metal monobloc loaded the lateral rim and behaved like a hemispherical rigid metal component with regard to loading of the acetabular bone. We suspect that this was due to the peripheral titanium rim used for the mechanism of insertion.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 1012 - 1018
1 Jul 2005
Beck M Kalhor M Leunig M Ganz R

Recently, femoroacetabular impingement has been recognised as a cause of early osteoarthritis. There are two mechanisms of impingement: 1) cam impingement caused by a non-spherical head and 2) pincer impingement caused by excessive acetabular cover. We hypothesised that both mechanisms result in different patterns of articular damage. Of 302 analysed hips only 26 had an isolated cam and 16 an isolated pincer impingement. Cam impingement caused damage to the anterosuperior acetabular cartilage with separation between the labrum and cartilage. During flexion, the cartilage was sheared off the bone by the non-spherical femoral head while the labrum remained untouched. In pincer impingement, the cartilage damage was located circumferentially and included only a narrow strip. During movement the labrum is crushed between the acetabular rim and the femoral neck causing degeneration and ossification.

Both cam and pincer impingement lead to osteoarthritis of the hip. Labral damage indicates ongoing impingement and rarely occurs alone.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 4 | Pages 467 - 471
1 Apr 2006
Leichtle UG Leichtle CI Schmidt B Martini F

Peri-prosthetic bone loss caused by stress shielding may be associated with aseptic loosening of femoral components. In order to increase primary stability and to reduce stress shielding, a three-dimensional, cementless individual femoral (Evolution K) component was manufactured using pre-operative CT scans. Using dual energy x-ray absorptiometry, peri-prosthetic bone density was measured in 43 patients, three months, six months, 3.6 and 4.6 years after surgery. At final follow-up there was a significant reduction in mean bone density in the proximal Gruen zones of −30.3% (zone 7) and −22.8% (zone 1). The density in the other zones declined by a mean of between −4% and −16%. We conclude that the manufacture of a three-dimensional, custom-made femoral component could not prevent a reduction in peri-prosthetic bone density.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 188 - 193
1 Feb 2011
Rudol G Wilcox R Jin Z Tsiridis E

The mechanical performance of the cement-in-cement interface in revision surgery has not been fully investigated. The quantitative effect posed by interstitial fluids and roughening of the primary mantle remains unclear. We have analysed the strength of the bilaminar cement-bone interface after exposure of the surface of the primary mantle to roughening and fluid interference. The end surfaces of cylindrical blocks of cement were machined smooth (Ra = 200 nm) or rough (Ra = 5 μm) and exposed to either different volumes of water and carboxymethylcellulose (a bone-marrow equivalent) or left dry. Secondary blocks were cast against the modelled surface. Monoblocks of cement were used as a control group. The porosity of the samples was investigated using micro-CT. Samples were exposed to a single shearing force to failure.

The mean failure load of the monoblock control was 5.63 kN (95% confidence interval (CI) 5.17 to 6.08) with an estimated shear strength of 36 MPa. When small volumes of any fluid or large volumes were used, the respective values fell between 4.66 kN and 4.84 kN with no significant difference irrespective of roughening (p > 0.05). Large volumes of carboxymethylcellulose significantly weakened the interface. Roughening in this group significantly increased the strength with failure loads of 2.80 kN (95% CI 2.37 to 3.21) compared with 0.86 kN (95% CI 0.43 to 1.27) in the smooth variant. Roughening of the primary mantle may not therefore be as crucial as has been previously thought in clinically relevant circumstances.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 769 - 776
1 Jun 2011
Hogervorst T Bouma H de Boer SF de Vos J

We examined the morphology of mammalian hips asking whether evolution can explain the morphology of impingement in human hips. We describe two stereotypical mammalian hips, coxa recta and coxa rotunda. Coxa recta is characterised by a straight or aspherical section on the femoral head or head-neck junction. It is a sturdy hip seen mostly in runners and jumpers. Coxa rotunda has a round femoral head with ample head-neck offset, and is seen mostly in climbers and swimmers.

Hominid evolution offers an explanation for the variants in hip morphology associated with impingement. The evolutionary conflict between upright gait and the birth of a large-brained fetus is expressed in the female pelvis and hip, and can explain pincer impingement in a coxa profunda. In the male hip, evolution can explain cam impingement in coxa recta as an adaptation for running.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 12 | Pages 1636 - 1641
1 Dec 2010
McLaughlin JR Lee KR

We reviewed 123 second-generation uncemented total hip replacements performed on 115 patients by a single surgeon between 1993 and 1994. The acetabular component used in all cases was a fully porous-coated threaded hemispheric titanium shell (T-Tap ST) with a calcium ion stearate-free, isostatically compression-moulded polyethylene liner. The titanium femoral component used was a Taperloc with a reduced distal stem. No patient was lost to follow-up. Complete clinical and radiological follow-up was obtained for all 123 hips at a mean of 14 years (12 to 16). One femoral component was revised after a fracture, and three acetabular components for aseptic loosening. No additional femoral or acetabular components were judged loose by radiological criteria. Mild proximal femoral osteolysis was identified in two hips and minor acetabular osteolysis was present in four. The mean rate of penetration of the femoral head was 0.036 mm/year (0.000 to 0.227).

These findings suggest that refinements in component design may be associated with excellent long-term fixation in cementless primary total hip replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 880 - 884
1 Jun 2010
Hassan A Whately C Letts M

Stüve-Wiedemann syndrome is an autosomal-recessive disorder characterised by bowing of the long bones, progressive scoliosis, episodic hyperthermia and respiratory distress, usually resulting in death in infancy. We reviewed five children with the condition who had been followed since birth and who survived into childhood with a mean age at operation of 7.8 years (5 to 14). There was marked functional impairment with dysplasia of the long bones and scoliosis. Treatment of the triplanar deformities of the femora involved the use of the Ilizarov technique with the Taylor Spatial Frame.

Walking was preserved and improved in three children along with considerable enhancement of the appearance. Early insertion of a growing rod to control the progressive juvenile scoliosis was beneficial. The use of the Taylor Spatial Frame is strongly recommended to address the major complex deformities of the lower limbs which are encountered in this condition and to prevent their progression.