Advertisement for orthosearch.org.uk
Results 641 - 660 of 849
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1567 - 1572
1 Nov 2012
Berkes MB Little MTM Lazaro LE Sculco PK Cymerman RM Daigl M Helfet DL Lorich DG

It has previously been suggested that among unstable ankle fractures, the presence of a malleolar fracture is associated with a worse outcome than a corresponding ligamentous injury. However, previous studies have included heterogeneous groups of injury. The purpose of this study was to determine whether any specific pattern of bony and/or ligamentous injury among a series of supination-external rotation type IV (SER IV) ankle fractures treated with anatomical fixation was associated with a worse outcome.

We analysed a prospective cohort of 108 SER IV ankle fractures with a follow-up of one year. Pre-operative radiographs and MRIs were undertaken to characterise precisely the pattern of injury. Operative treatment included fixation of all malleolar fractures. Post-operative CT was used to assess reduction. The primary and secondary outcome measures were the Foot and Ankle Outcome Score (FAOS) and the range of movement of the ankle.

There were no clinically relevant differences between the four possible SER IV fracture pattern groups with regard to the FAOS or range of movement. In this population of strictly defined SER IV ankle injuries, the presence of a malleolar fracture was not associated with a significantly worse clinical outcome than its ligamentous injury counterpart. Other factors inherent to the injury and treatment may play a more important role in predicting outcome.


Bone & Joint 360
Vol. 1, Issue 4 | Pages 29 - 31
1 Aug 2012

The August 2012 Children’s orthopaedics Roundup360 looks at: whether 3D-CT gives a better idea of coverage than plain radiographs; forearm fractures after trampolining accidents; forearm fractures and the Rush pin; the fractured distal radius; elastic stable intramedullary nailing for long-bone fractures; aponeurotic recession for the equinus foot; the torn medial patellofemoral ligament and the adductor tubercle; slipped capital femoral epiphysis; paediatric wrist arthroscopy; and Pirani scores and clubfoot.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 202 - 208
1 Feb 2010
Berton C Girard J Krantz N Migaud H

Implantation of a large-diameter femoral head prosthesis with a metal-on-metal bearing surface reduces the risk of dislocation, increases the range of movement, minimises the risk of impingement and, in theory, results in little wear.

Between February 2004 and March 2007 we implanted 100 consecutive total hip replacements with a metal-on-metal bearing and a large femoral head into 92 patients. There were 51 men and 41 women with a mean age of 50 years (18 to 70) at the time of surgery.

Outcome was assessed using the Western Ontario McMaster University osteoarthritis index and the Harris hip score as well as the Devane activity score. These all improved significantly (p < 0.0001). At the last follow-up there were no cases of dislocation, no impingement, a good range of movement and no osteolysis, but seven revisions, two for infection and five for aseptic loosening. The probability of groin pain increased if the other acetabular component inclination exceeded 50° (p = 0.0007). At 4.8 years of follow-up, the projected survival of the Durom acetabular component, with revision for any reason, was 92.4% (sd 2.8) (95% confidence interval 89.6 to 95.2).

The design of the component made it difficult both to orientate and seat, which when combined with a poor porous coating, produced unpredictable fixation and a low survival at five years.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 5 | Pages 629 - 637
1 May 2008
Forward DP Davis TRC Sithole JS

Fractures of the distal radius occurring in young adults are treated increasingly by open surgical techniques, partly because of concern that failure to restore the alignment of the fracture accurately may cause symptomatic post-traumatic osteoarthritis in future years. We reviewed 106 adults who had sustained a fracture of the distal radius between 1960 and 1968 and who were below the age of 40 years at the time of injury. We carried out a clinical and radiological assessment at a mean follow-up of 38 years (33 to 42).

No patient had required a salvage procedure. While there was radiological evidence of post-traumatic osteoarthritis after an intra-articular fracture in 68% of patients (27 of 40), the disabilities of the arm, shoulder and hand (DASH) scores were not different from population norms, and function, as assessed by the Patient Evaluation Measure, was impaired by less than 10%. Ordinal logistic regression analysis showed a significant relationship between narrowing of the joint space and extra-articular malunion (dorsal angulation and radial shortening) as well as intra-articular injury. Multivariate analysis revealed that grip strength had fallen to 89% of that of the uninjured side in the presence of dorsal malunion, but no measure of extra-articular malunion was significantly related to either the Patient Evaluation Measure or DASH scores.

While anatomical reduction is the principal aim of treatment, imperfect reduction of these fractures may not result in symptomatic arthritis in the long term, and this should be considered when counselling patients on the risks and benefits of the many treatment options available.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 10 | Pages 1309 - 1316
1 Oct 2007
Gosvig KK Jacobsen S Palm H Sonne-Holm S Magnusson E

Femoroacetabular cam impingement is thought to be a cause of premature osteoarthritis of the hip.

The presence of cam malformation was determined in 2803 standardised anteroposterior (AP) pelvic radiographs from the Copenhagen Osteoarthritis Study by measuring the alpha (α) angle and the triangular index, a new measure of asphericity of the femoral head. In addition, the α-angle and the triangular index were assessed on the AP and lateral hip radiographs of 82 men and 82 women randomly selected from patients scheduled for total hip replacement (THR). The influence of varying femoral rotation on the α angle and the triangular index was also determined in femoral specimens under experimental conditions.

From the 2803 radiographs the mean AP α-angle was 55° (30° to 100°) in men and 45° (34° to 108°) in women. Approximately 6% of men and 2% of women had cam malformation. The α-angle and triangular index were highly inter-related. Of those patients scheduled for THR, 36 men (44%) and 28 women (35%) had cam malformation identifiable on the AP radiographs. The triangular index proved to be more reliable in detecting cam malformation when the hip was held in varying degrees of rotation.

The combination of the α-angle and the triangular index will allow examination of historical radiographs for epidemiological purposes in following the natural history of the cam deformity.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1271 - 1276
1 Sep 2012
Luyckx T Peeters T Vandenneucker H Victor J Bellemans J

Obtaining a balanced flexion gap with correct femoral component rotation is one of the prerequisites for a successful outcome after total knee replacement (TKR). Different techniques for achieving this have been described. In this study we prospectively compared gap-balancing versus measured resection in terms of reliability and accuracy for femoral component rotation in 96 primary TKRs performed in 96 patients using the Journey system. In 48 patients (18 men and 30 women) with a mean age of 65 years (45 to 85) a tensor device was used to determine rotation. In the second group of 48 patients (14 men and 34 women) with a mean age of 64 years (41 to 86), an ‘adapted’ measured resection technique was used, taking into account the native rotational geometry of the femur as measured on a pre-operative CT scan.

Both groups systematically reproduced a similar external rotation of the femoral component relative to the surgical transepicondylar axis: 2.4° (sd 2.5) in the gap-balancing group and 1.7° (sd 2.1) in the measured resection group (p = 0.134). Both gap-balancing and adapted measured resection techniques proved equally reliable and accurate in determining femoral component rotation after TKR. There was a tendency towards more external rotation in the gap-balancing group, but this difference was not statistically significant (p = 0.134). The number of outliers for our ‘adapted’ measured resection technique was much lower than reported in the literature.


Bone & Joint 360
Vol. 1, Issue 3 | Pages 10 - 12
1 Jun 2012

The June 2012 Hip & Pelvis Roundup360 looks at: whether metal-on-metal is really such a disaster; resurfacings with unexplained pain; large heads and high ion levels; hip arthroscopy for FAI; the inaccuracy of clinical tests for impingement; arthroscopic lengthening of iliopsoas; the OA hip; the injured hamstring – football’s most common injury; an algorithm for hip fracture surgery; and sparing piriformis at THR.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1431 - 1438
1 Nov 2007
Hing CB Back DL Bailey M Young DA Dalziel RE Shimmin AJ

We report an independent prospective review of the first 230 Birmingham hip resurfacings in 212 patients at a mean follow-up of five years (4 to 6).

Two patients, one with a loose acetabular component and the other with suspected avascular necrosis of the femoral head, underwent revision. There were two deaths from unrelated causes and one patient was lost to follow-up. The survivorship with the worst-case scenario was 97.8% (95% confidence interval 95.8 to 99.5). The mean Harris hip score improved significantly (paired t-test, p < 0.05) from 62.54 (8 to 92) pre-operatively to 97.7 (61 to 100) at a mean of three years (2.1 to 4.3), then deteriorated slightly to a mean of 95.2 (47 to 100) at a mean of five years. The mean flexion improved from 91.5° (25° to 140°) to 110.4° (80° to 145°) at a mean of three years with no further improvement at five years (111.2°; 70° to 160°).

On radiological review at five years, one patient had a progressive lucent line around the acetabular component and six had progressive lucent lines around the femoral component. A total of 18 femoral components (8%) had migrated into varus and those with lucent lines present migrated a mean of 3.8° (1.02° to 6.54°) more than the rest. Superolateral notching of the femoral neck and reactive sclerosis at the tip of the peg of the femoral component were associated with the presence of lucent lines (chi-squared test, p < 0.05), but not with migration of the femoral component, and are of unknown significance.

Our results with the Birmingham hip resurfacing continue to be satisfactory at a mean follow-up of five years.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 8 | Pages 1045 - 1053
1 Aug 2010
Phillips CL Silver DAT Schranz PJ Mandalia V

Many radiographic techniques have been described for measuring patellar height. They can be divided into two groups: those that relate the position of the patella to the femur (direct) and those that relate it to the tibia (indirect). This article looks at the methods that have been described, the logic behind their conception and the critical analyses that have been performed to test them.


Bone & Joint 360
Vol. 1, Issue 4 | Pages 12 - 15
1 Aug 2012

The August 2012 Knee Roundup360 looks at: meniscal defects and a polyurethane scaffold; which is best between a single or double bundle; OA of the knee; how to resolve anterior knee pain; whether yoga can be bad for your menisci; metal ions in the serum; whether ACI is any good; the ACL; whether hyaluronic acid delays collagen degradation; and hyaluronan and patellar tendinopathy.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 12 | Pages 1612 - 1617
1 Dec 2009
Venkatesh KP Modi HN Devmurari K Yoon JY Anupama BR Song HR

Extensive limb lengthening may be indicated in achondroplastic patients who wish to achieve a height within the normal range for their population. However, increasing the magnitude of lengthening is associated with further complications particularly adjacent joint stiffness and fractures. We studied the relationship between the magnitude of femoral lengthening and callus pattern, adjacent joint stiffness and fracture of the regenerate bone in 40 femoral lengthenings in 20 achondroplastic patients. They were divided into two groups; group A had lengthening of less than 50% and group B of more than 50% of their initial femoral length. The patterns of radiological callus formation were classified according to shape, type and features. The incidence of callus features, knee stiffness and regenerate bone fracture were analysed in the two groups. Group B was associated with an increased incidence of concave, lateral and central callus shapes, adjacent joint and stiffness and fracture. Statistically, the incidence of stiffness in adjacent joints and regenerate bone fracture was significantly associated with the magnitude of lengthening.

We suggest that careful radiological assessment of the patterns of callus formation is a useful method for the evaluation and monitoring of regenerate bone.


Bone & Joint 360
Vol. 1, Issue 3 | Pages 19 - 21
1 Jun 2012

The June 2012 Shoulder & Elbow Roundup360 looks at: reverse shoulder replacement; torn rotator cuffs and platelet-rich fibrin; rotator cuff repair; frozen shoulder; whether an arthroscopic rotator cuff repair actually heals; the torn rotator cuff’s effect on activities of daily living; subacromial impingement; how to improve the reliability of the Constant-Murley score; and failure of the Neer modification of an open Bankart procedure.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 11 | Pages 1498 - 1501
1 Nov 2005
Grelsamer RP Dubey A Weinstein CH

The Q angle is an important determinant of patellar tracking, though its clinical relevance is debatable. One controversy centres around any possible differences in its value between men and women. The accepted, though unproven explanation, for the greater Q angle in women is that a woman has a wider pelvis. However, because of the long distance between the pelvis and patella, relative to the distance from the patella to the tibial tuberosity, large changes in the position of the anterior superior iliac spine are necessary to effect significant changes in the Q angle. In our study of 69 subjects, we did not find such large differences in the position of the anterior superior iliac spine, and found a mean difference of only 2.3° between the Q angles of men and women.

Furthermore, we found that men and women of equal height demonstrated similar Q angles, with taller people having slightly smaller Q angles. The slight difference in Q angles between men and women can be explained by the fact that men tend to be taller.


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 583 - 597
1 May 2013
Kurien T Pearson RG Scammell BE

We reviewed 59 bone graft substitutes marketed by 17 companies currently available for implantation in the United Kingdom, with the aim of assessing the peer-reviewed literature to facilitate informed decision-making regarding their use in clinical practice. After critical analysis of the literature, only 22 products (37%) had any clinical data. Norian SRS (Synthes), Vitoss (Orthovita), Cortoss (Orthovita) and Alpha-BSM (Etex) had Level I evidence. We question the need for so many different products, especially with limited published clinical evidence for their efficacy, and conclude that there is a considerable need for further prospective randomised trials to facilitate informed decision-making with regard to the use of current and future bone graft substitutes in clinical practice.

Cite this article: Bone Joint J 2013;95-B:583–97.


Bone & Joint Research
Vol. 1, Issue 11 | Pages 289 - 296
1 Nov 2012
Savaridas T Wallace RJ Muir AY Salter DM Simpson AHRW

Objectives

Small animal models of fracture repair primarily investigate indirect fracture healing via external callus formation. We present the first described rat model of direct fracture healing.

Methods

A rat tibial osteotomy was created and fixed with compression plating similar to that used in patients. The procedure was evaluated in 15 cadaver rats and then in vivo in ten Sprague-Dawley rats. Controls had osteotomies stabilised with a uniaxial external fixator that used the same surgical approach and relied on the same number and diameter of screw holes in bone.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1221 - 1227
1 Sep 2012
Kim Y Park J Kim J

Despite many claims of good wear properties following total knee replacement (TKR) with an oxidised zirconium (OxZr) femoral component, there are conflicting clinical results. We hypothesised that there would be no difference in either the mid-term clinical and radiological outcomes or the characteristics of the polyethylene wear particles (weight, size and shape) in patients using an OxZr or cobalt-chrome (CoCr) femoral component. In all 331 patients underwent bilateral TKR, receiving an OxZr femoral component in one knee and a CoCr femoral component in the other. The mean follow-up was 7.5 years (6 to 8). Following aspiration, polyethylene wear particles were analysed using thermogravimetric methods and scanning electron microscopy. At the most recent follow-up, the mean Knee Society score, Western Ontario and McMaster Universities Osteoarthritis Index score, range of movement and satisfaction score were not significantly different in the two groups. The mean weight, size, aspect ratio and roundness of the aspirated wear particles were similar for each femoral component. Survivorship of the femoral, tibial and patellar components was 100% in both groups.

In the absence of evidence of an advantage in the medium term we cannot justify the additional expense of an OxZr femoral component.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 950 - 955
1 Jul 2012
Helenius I Serlo J Pajulo O

We report the results of vertebral column resection (VCR) for paediatric patients with spinal deformity. A total of 49 VCRs in paediatric patients from four university hospitals between 2005 and 2009 with a minimum two-year follow-up were retrospectively identified. After excluding single hemivertebral resections (n = 25) and VCRs performed for patients with myelomeningocele (n = 6), as well as spondylectomies performed for tumour (n = 4), there were 14 patients who had undergone full VCR at a mean age of 12.3 years (6.5 to 17.9). The aetiology was congenital scoliosis in five, neuromuscular scoliosis in three, congenital kyphosis in two, global kyphosis in two, adolescent idiopathic scoliosis in one and secondary scoliosis in one. A total of seven anteroposterior and seven posterolateral approaches were used.

The mean major curve deformity was 86° (67° to 120°) pre-operatively and 37° (17° to 80°) at the two-year follow-up; correction was a mean of 54% (18% to 86%) in the anteroposterior and 60% (41% to 70%) in the posterolateral group at the two-year follow-up (p = 0.53). The mean Scoliosis Research Society-24 total scores were 100 (92 to 108) for the anteroposterior and 102 (95 to 105) for the posterolateral group. There was one paraparesis in the anteroposterior group necessitating urgent re-decompression, with a full recovery.

Patients undergoing VCR are highly satisfied after a successful procedure.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1107 - 1112
1 Aug 2012
Bugler KE Watson CD Hardie AR Appleton P McQueen MM Court-Brown CM White TO

Techniques for fixation of fractures of the lateral malleolus have remained essentially unchanged since the 1960s, but are associated with complication rates of up to 30%. The fibular nail is an alternative method of fixation requiring a minimal incision and tissue dissection, and has the potential to reduce the incidence of complications.

We reviewed the results of 105 patients with unstable fractures of the ankle that were fixed between 2002 and 2010 using the Acumed fibular nail. The mean age of the patients was 64.8 years (22 to 95), and 80 (76%) had significant systemic medical comorbidities. Various different configurations of locking screw were assessed over the study period as experience was gained with the device. Nailing without the use of locking screws gave satisfactory stability in only 66% of cases (4 of 6). Initial locking screw constructs rendered between 91% (10 of 11) and 96% (23 of 24) of ankles stable. Overall, seven patients had loss of fixation of the fracture and there were five post-operative wound infections related to the distal fibula. This lead to the development of the current technique with a screw across the syndesmosis in addition to a distal locking screw. In 21 patients treated with this technique there have been no significant complications and only one superficial wound infection. Good fracture reduction was achieved in all of these patients. The mean physical component Short-Form 12, Olerud and Molander score, and American Academy of Orthopaedic Surgeons Foot and Ankle outcome scores at a mean of six years post-injury were 46 (28 to 61), 65 (35 to 100) and 83 (52 to 99), respectively. There have been no cases of fibular nonunion.

Nailing of the fibula using our current technique gives good radiological and functional outcomes with minimal complications, and should be considered in the management of patients with an unstable ankle fracture.


Bone & Joint 360
Vol. 1, Issue 1 | Pages 10 - 12
1 Feb 2012


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 8 | Pages 1081 - 1084
1 Aug 2005
Han I Chang CB Lee S Lee MC Seong SC Kim TK

We sought to determine the degree of correlation between the condition of the patellar articular cartilage and patellofemoral symptoms and function in osteoarthritic patients undergoing total knee arthroplasty. The depth of the osteoarthritic lesion, as graded by the Outerbridge classification and its size and location were assessed to determine the condition of the patellar cartilage in 80 consecutive osteoarthritic knees undergoing total knee arthroplasty. The association between the condition of the cartilage and patellofemoral symptoms and function was investigated by correlation analysis.

The depth and size of the lesion had a significant but weak correlation with anterior knee pain (r = −0.300 and −0.289; p = 0.007 and 0.009, respectively), whereas location had no significant association (p > 0.05). None had a significant association with patellofemoral functional parameters (chair-rising, stair-climbing, and quadriceps power) (p > 0.05).

Our study indicates that patellofemoral symptoms and function are not completely determined by the condition of the cartilage. Caution should be taken when the symptoms and functional limitations are attributed to a lesion in the patellofemoral joint in making a decision regarding patellar resurfacing in total knee arthroplasty.