The study objective was to prospectively assess clinical outcomes for a pilot cohort of tibial shaft fractures treated with a new tibial nailing system that produces controlled axial interfragmentary micromotion. The hypothesis was that axial micromotion enhances fracture healing compared to static interlocking. Patients were treated in a single level I trauma centre over a 2.5-year period. Group allocation was not randomized; both the micromotion nail and standard-of-care static locking nails (control group) were commercially available and selected at the discretion of the treating surgeons. Injury risk levels were quantified using the Nonunion Risk Determination (NURD) score. Radiological healing was assessed until 24 weeks or clinical union. Low-dose CT scans were acquired at 12 weeks and virtual mechanical testing was performed to objectively assess structural bone healing.Aims
Methods
To determine the likelihood of achieving a successful closed reduction (CR) of a dislocated hip in developmental dysplasia of the hip (DDH) after failed Pavlik harness treatment We report the rate of avascular necrosis (AVN) and the need for further surgical procedures. Data was obtained from the Northern Ireland DDH database. All children who underwent an attempted closed reduction between 2011 and 2016 were identified. Children with a dislocated hip that failed Pavlik harness treatment were included in the study. Successful closed reduction was defined as a hip that reduced in theatre and remained reduced. Most recent imaging was assessed for the presence of AVN using the Kalamchi and MacEwen classification.Aims
Methods
Between March 1994 and June 2003, 80 patients with brachial plexus palsy underwent a trapezius transfer. There were 11 women and 69 men with a mean age of 31 years (18 to 69). Before operation a full evaluation of muscle function in the affected arm was carried out. A completely flail arm was found in 37 patients (46%). Some peripheral function in the elbow and hand was seen in 43 (54%). No patient had full active movement of the elbow in combination with adequate function of the hand. Patients were followed up for a mean of 2.4 years (0.8 to 8). We performed the operations according to Saha’s technique, with a modification in the last 22 cases. We demonstrated a difference in the results according to the pre-operative status of the muscles and the operative technique. The transfer resulted in an increase of function in all patients and in 74 (95%) a decrease in multidirectional
We aimed to compare the implant survival, complications, readmissions, and mortality of Vancouver B2 periprosthetic femoral fractures (PFFs) treated with internal fixation with that of B1 PFFs treated with internal fixation and B2 fractures treated with revision arthroplasty. We retrospectively reviewed the data of 112 PFFs, of which 47 (42%) B1 and 27 (24%) B2 PFFs were treated with internal fixation, whereas 38 (34%) B2 fractures underwent revision arthroplasty. Decision to perform internal fixation for B2 PFFs was based on specific radiological (polished femoral components, intact bone-cement interface) and clinical criteria (low-demand patient). Median follow-up was 36.4 months (24 to 60). Implant survival and mortality over time were estimated with the Kaplan-Meier method. Adverse events (measured with a modified Dindo-Clavien classification) and 90-day readmissions were additionally compared between groups.Aims
Methods
Aims. Our aim was to investigate the prevalence of Propionibacterium
(P.) acnes in the subcutaneous fat and capsule of patients
undergoing shoulder surgery for frozen shoulder or
Dislocation is a common and well-studied complication after total hip replacement. However, subluxation, which we define as a clinically recognised episode of incomplete movement of the femoral head outside the acetabulum with spontaneous reduction, has not been studied previously. Out of a total of 2521 hip replacements performed over 12 years by one surgeon, 30 patients experienced subluxations which occurred in 31 arthroplasties. Data were collected prospectively with a minimum follow-up of two years. Subluxation occurred significantly more frequently after revision than after primary hip replacement, and resolved in 19 of 31 cases (61.3%). In six of the 31 hips (19.4%) the patient subsequently dislocated the affected hip, and in six hips (19.4%) intermittent subluxation continued. Four patients had a revision operation for
To establish our early clinical results of a new total knee arthroplasty (TKA) tibial component introduced in 2013 and compare it to other designs in use at our hospital during the same period. This is a retrospective study of 166 (154 patients) consecutive cemented, fixed bearing, posterior-stabilized (PS) TKAs (ATTUNE) at one hospital performed by five surgeons. These were compared with a reference cohort of 511 knees (470 patients) of other designs (seven manufacturers) performed at the same hospital by the same surgeons. There were no significant differences in age, sex, BMI, or follow-up times between the two cohorts. The primary outcome was revision performed or pending.Aims
Methods
Dual mobility implants in total hip arthroplasty are designed to increase the functional head size, thus decreasing the potential for dislocation. Modular dual mobility (MDM) implants incorporate a metal liner (e.g. cobalt-chromium alloy) in a metal shell (e.g. titanium alloy), raising concern for mechanically assisted crevice corrosion at the modular liner-shell connection. We sought to examine fretting and corrosion on MDM liners, to analyze the corrosion products, and to examine histologically the periprosthetic tissues. A total of 60 retrieved liners were subjectively scored for fretting and corrosion. The corrosion products from the three most severely corroded implants were removed from the implant surface, imaged using scanning electron microscopy, and analyzed using Fourier-transform infrared spectroscopy.Aims
Methods
We describe a modified technique of micro-decompression of the lumbar spine involving the use of an operating microscope, a malleable retractor and a high-speed burr, which allows decompression to be performed on both sides of the spine through a unilateral, hemi-laminectomy approach. The first 100 patients to be treated with this technique have been evaluated prospectively using a visual analogue score for sciatica and back pain, the MacNab criteria for patient satisfaction, and functional assessment with the Oswestry Disability Index. After a period of follow-up from 12 months to six years and four months, sciatica had improved in 90 patients and back pain in 84 patients. Their result was graded as good or excellent by 82 patients according to the MacNab criteria, and 75 patients had subjective improvement in their walking distance. Late
Rotating-hinge knee prostheses are commonly used to reconstruct the distal femur after resection of a tumour, despite the projected long-term burden of reoperation due to complications. Few studies have examined the factors that influence their failure and none, to our knowledge, have used competing risk models to do so. The purpose of this study was to determine the risk factors for failure of a rotating-hinge knee distal femoral arthroplasty using the Fine-Gray competing risk model. We retrospectively reviewed 209 consecutive patients who, between 1991 and 2016, had undergone resection of the distal femur for tumour and reconstruction using a rotating-hinge knee prosthesis. The study endpoint was failure of the prosthesis, defined as removal of the femoral component, the tibial component, or the bone-implant fixation; major revision (exchange of the femoral component, tibial component, or the bone-implant fixation); or amputation.Aims
Methods
It has previously been shown that higher-volume hospitals have better outcomes following revision total knee arthroplasty (rTKA). We were unable to identify any studies which investigated the effect of surgeon volume on the outcome of rTKA. We sought to investigate whether patients of high-volume (HV) rTKA surgeons have better outcomes following this procedure compared with those of low-volume (LV) surgeons. This retrospective study involved patients who underwent aseptic unilateral rTKA between January 2016 and March 2019, using the database of a large urban academic medical centre. Surgeons who performed ≥ 19 aseptic rTKAs per year during the study period were considered HV and those who performed < 19 per year were considered LV. Demographic characteristics, surgical factors, and postoperative outcomes were compared between the two groups.Aims
Methods
The aim of this study was to identify the origin and development of the threshold for surgical intervention, highlight the consequences of residual displacement, and justify the importance of accurate measurement. A systematic review of three databases was performed to establish the origin and adaptations of the threshold, with papers screened and relevant citations reviewed. This search identified papers investigating functional outcome, including presence of arthritis, following injury. Orthopaedic textbooks were reviewed to ensure no earlier mention of the threshold was present.Aims
Methods
Limb alignment in total knee arthroplasty (TKA) influences periarticular soft-tissue tension, biomechanics through knee flexion, and implant survival. Despite this, there is no uniform consensus on the optimal alignment technique for TKA. Neutral mechanical alignment facilitates knee flexion and symmetrical component wear but forces the limb into an unnatural position that alters native knee kinematics through the arc of knee flexion. Kinematic alignment aims to restore native limb alignment, but the safe ranges with this technique remain uncertain and the effects of this alignment technique on component survivorship remain unknown. Anatomical alignment aims to restore predisease limb alignment and knee geometry, but existing studies using this technique are based on cadaveric specimens or clinical trials with limited follow-up times. Functional alignment aims to restore the native plane and obliquity of the joint by manipulating implant positioning while limiting soft tissue releases, but the results of high-quality studies with long-term outcomes are still awaited. The drawbacks of existing studies on alignment include the use of surgical techniques with limited accuracy and reproducibility of achieving the planned alignment, poor correlation of intraoperative data to long-term functional outcomes and implant survivorship, and a paucity of studies on the safe ranges of limb alignment. Further studies on alignment in TKA should use surgical adjuncts (e.g. robotic technology) to help execute the planned alignment with improved accuracy, include intraoperative assessments of knee biomechanics and periarticular soft-tissue tension, and correlate alignment to long-term functional outcomes and survivorship.
Alternative alignment concepts, including kinematic and restricted kinematic, have been introduced to help improve clinical outcomes following total knee arthroplasty (TKA). The purpose of this study was to evaluate the clinical results, along with patient satisfaction, following TKA using the concept of restricted kinematic alignment. A total of 121 consecutive TKAs performed between 11 February 2018 to 11 June 2019 with preoperative varus deformity were reviewed at minimum one-year follow-up. Three knees were excluded due to severe preoperative varus deformity greater than 15°, and a further three due to requiring revision surgery, leaving 109 patients and 115 knees to undergo primary TKA using the concept of restricted kinematic alignment with advanced technology. Patients were stratified into three groups based on the preoperative limb varus deformity: Group A with 1° to 5° varus (43 knees); Group B between 6° and 10° varus (56 knees); and Group C with varus greater than 10° (16 knees). This study group was compared with a matched cohort of 115 TKAs and 115 patients using a neutral mechanical alignment target with manual instruments performed from 24 October 2016 to 14 January 2019.Aims
Methods
Objectives. A variety of operative techniques have been described as under
the term ‘Bristow-Latarjet’ procedure. This review aims to define
the original procedure, and compare the variation in techniques
described in the literature, assessing any effect on clinical outcomes. Materials and Methods. A systematic review of 24 studies was performed to compare specific
steps of the technique (coracoid osteotomy site, subscapularis approach,
orientation and position of coracoid graft fixation and fixation
method, additional labral and capsular repair) and detect any effect
this variability had on outcomes. Results. Overall recurrence rate was 5.36% (2.94% to 43%). Half of the
studies performed the procedure for recurrent shoulder instability,
with only five studies documenting glenoid bone loss as an indication:
12 studies used the procedure as the primary surgical intervention
for recurrent