Advertisement for orthosearch.org.uk
Results 41 - 56 of 56
Results per page:
The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 647 - 652
1 May 2017
Abdel MP Ledford CK Kobic A Taunton MJ Hanssen AD

Aims

The number of revision total knee arthroplasties (TKA) that are performed is expected to increase. However, previous reports of the causes of failure after TKA are limited in that they report the causes at specific institutions, which are often dependent on referral patterns. Our aim was to report the most common indications for re-operations and revisions in a large series of posterior-stabilised TKAs undertaken at a single institution, excluding referrals from elsewhere, which may bias the causes of failure.

Patients and Methods

A total of 5098 TKAs which were undertaken between 2000 and 2012 were included in the study. Re-operations, revisions with modular component exchange, and revisions with non-modular component replacement or removal were identified from the medical records. The mean follow-up was five years (two to 12).


The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1477 - 1481
1 Nov 2017
Hernandez NM Taunton MJ Perry KI Mara KC Hanssen AD Abdel MP

Aims

Patients with flexion instability after total knee arthroplasty (TKA) often present with a recurrent effusion, which may be a haemarthrosis. While the radiographic factors contributing to flexion instability have been elucidated, the clinical diagnosis remains challenging. Our aim, in this study, was to determine the mean white cell count and differential profile in pre-operative aspirations of synovial fluid in a consecutive series of patients undergoing revision TKA for flexion instability.

Patients and Methods

Between 2000 and 2010, 60 patients undergoing aseptic revision TKA for flexion instability were identified. The results of the pre-operative aspiration of synovial fluid were available for 53 patients (88%). These patients were 1:2 matched to 106 patients who underwent aseptic TKA for indications other than flexion instability. The mean age of the patients at revision TKA was 65 years (44 to 82) and 55% were women. The mean follow-up was 4.3 years (2 to 10.2).


The Bone & Joint Journal
Vol. 98-B, Issue 4 | Pages 461 - 467
1 Apr 2016
Abdel MP Watts CD Houdek MT Lewallen DG Berry DJ

Aim and Methods

The goals of this study were to define the risk factors, nature, chronology, and treatment strategies adopted for periprosthetic femoral fractures in 32 644 primary total hip arthroplasties (THAs).

Results

There were 564 intra-operative fractures (1.7%); 529 during uncemented stem placement (3.0%) and 35 during cemented stem placement (0.23%). Intra-operative fractures were more common in females and patients over 65 years (p < 0.001). The majority occurred during placement of the femoral component (60%), and involved the calcar (69%). There were 557 post-operative fractures (20-year probability: 3.5%; 95% confidence interval (CI) 3.2 to 3.9); 335 fractures after placement of an uncemented stem (20-year probability: 7.7%; 95% CI 6.2 to 9.1) and 222 after placement of a cemented stem (20-year probability: 2.1%; 95% CI 1.8 to 2.5). The probability of a post-operative fracture within 30 days after an uncemented stem was ten times higher than a cemented stem. The most common post-operative fracture type was a Vancouver AG (32%; n = 135), with 67% occurring after a fall. In all, 36% (n = 152) were treated with revision arthroplasty.


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 666 - 673
1 May 2017
Werthel J Lonjon G Jo S Cofield R Sperling JW Elhassan BT

Aims

In the initial development of total shoulder arthroplasty (TSA), the humeral component was usually fixed with cement. Cementless components were subsequently introduced. The aim of this study was to compare the long-term outcome of cemented and cementless humeral components in arthroplasty of the shoulder.

Patients and Methods

All patients who underwent primary arthroplasty of the shoulder at our institution between 1970 and 2012 were included in the study. There were 4636 patients with 1167 cemented humeral components and 3469 cementless components. Patients with the two types of fixation were matched for nine different covariates using a propensity score analysis. A total of 551 well-balanced pairs of patients with cemented and cementless components were available after matching for comparison of the outcomes. The clinical outcomes which were analysed included loosening of the humeral component determined at revision surgery, periprosthetic fractures, post-operative infection and operating time.


The Bone & Joint Journal
Vol. 98-B, Issue 4 | Pages 468 - 474
1 Apr 2016
Abdel MP Houdek MT Watts CD Lewallen DG Berry DJ

Aims

The goals of this study were to define the risk factors, characteristics, and chronology of fractures in 5417 revision total hip arthroplasties (THAs).

Patients and Methods

From our hospital’s prospectively collected database we identified all patients who had undergone a revision THA between 1969 and 2011 which involved the femoral stem. The patients’ medical records and radiographs were examined and the relevant data extracted. Post-operative periprosthetic fractures were classified using the Vancouver system. A total of 5417 revision THAs were identified.


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 312 - 317
1 Mar 2015
Amanatullah DF Howard JL Siman H Trousdale RT Mabry TM Berry DJ

Revision total hip arthroplasty (THA) is challenging when there is severe loss of bone in the proximal femur. The purpose of this study was to evaluate the clinical and radiographic outcomes of revision THA in patients with severe proximal femoral bone loss treated with a fluted, tapered, modular femoral component. Between January 1998 and December 2004, 92 revision THAs were performed in 92 patients using a single fluted, tapered, modular femoral stem design. Pre-operative diagnoses included aseptic loosening, infection and peri-prosthetic fracture. Bone loss was categorised pre-operatively as Paprosky types III-IV, or Vancouver B3 in patients with a peri-prosthetic fracture. The mean clinical follow-up was 6.4 years (2 to 12). A total of 47 patients had peri-operative complications, 27 of whom required further surgery. However, most of these further operations involved retention of a well-fixed femoral stem, and 88/92 femoral components (97%) remained in situ. Of the four components requiring revision, three were revised for infection and were well fixed at the time of revision; only one (1%) was revised for aseptic loosening. The most common complications were post-operative instability (17 hips, 19%) and intra-operative femoral fracture during insertion of the stem (11 hips, 12%). Diaphyseal stress shielding was noted in 20 hips (22%). There were no fractures of the femoral component. At the final follow-up 78% of patients had minimal or no pain.

Revision THA in patients with extensive proximal femoral bone loss using the Link MP fluted, tapered, modular stem led to a high rate of osseointegration of the stem at mid-term follow-up.

Cite this article: Bone Joint J 2015; 97-B:312–17.


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1644 - 1648
1 Dec 2014
Abdel MP Pulido L Severson EP Hanssen AD

Instability in flexion after total knee replacement (TKR) typically occurs as a result of mismatched flexion and extension gaps. The goals of this study were to identify factors leading to instability in flexion, the degree of correction, determined radiologically, required at revision surgery, and the subsequent clinical outcomes. Between 2000 and 2010, 60 TKRs in 60 patients underwent revision for instability in flexion associated with well-fixed components. There were 33 women (55%) and 27 men (45%); their mean age was 65 years (43 to 82). Radiological measurements and the Knee Society score (KSS) were used to assess outcome after revision surgery. The mean follow-up was 3.6 years (2 to 9.8). Decreased condylar offset (p < 0.001), distalisation of the joint line (p < 0.001) and increased posterior tibial slope (p < 0.001) contributed to instability in flexion and required correction at revision to regain stability. The combined mean correction of posterior condylar offset and joint line resection was 9.5 mm, and a mean of 5° of posterior tibial slope was removed. At the most recent follow-up, there was a significant improvement in the mean KSS for the knee and function (both p < 0.001), no patient reported instability and no patient underwent further surgery for instability.

The following step-wise approach is recommended: reduction of tibial slope, correction of malalignment, and improvement of condylar offset. Additional joint line elevation is needed if the above steps do not equalise the flexion and extension gaps.

Cite this article: Bone Joint J 2014;96-B:1644–8.


Bone & Joint 360
Vol. 1, Issue 6 | Pages 10 - 12
1 Dec 2012

The December 2012 Hip & Pelvis Roundup360 looks at: swimming against the tide with resurfacing; hip impingement surgery; the relationship between obesity and co-morbidities and joint replacement infection; cemented hips; cross-linked polyethylene notching; whether cement is necessary in oncological arthroplasty; and how total hip replacement may result in weight gain.


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 367 - 370
1 Mar 2013
Bini SA Chen Y Khatod M Paxton EW

We evaluated the impact of pre-coating the tibial component with polymethylmethacrylate (PMMA) on implant survival in a cohort of 16 548 primary NexGen total knee replacements (TKRs) in 14 113 patients. In 13 835 TKRs a pre-coated tray was used while in 2713 TKRs the non-pre-coated version of the same tray was used. All the TKRs were performed between 2001 and 2009 and were cemented. TKRs implanted with a pre-coated tibial component had a lower cumulative survival than those with a non-pre-coated tibial component (p = 0.01). After adjusting for diagnosis, age, gender, body mass index, American Society of Anesthesiologists grade, femoral coupling design, surgeon volume and hospital volume, pre-coating was an independent risk factor for all-cause aseptic revision (hazard ratio 2.75, p = 0.006). Revision for aseptic loosening was uncommon for both pre-coated and non-pre-coated trays (rates of 0.12% and 0%, respectively). Pre-coating with PMMA does not appear to be protective of revision for this tibial tray design at short-term follow-up.

Cite this article: Bone Joint J 2013;95-B:367–70.


Bone & Joint 360
Vol. 1, Issue 2 | Pages 21 - 23
1 Apr 2012

The April 2012 Shoulder & Elbow Roundup360 looks at katakori in Japan, frozen shoulder, if shoulder impingement actually exists, shoulder arthroscopy and suprascapular nerve blocks, why shoulder replacements fail, the infected elbow replacement, the four-part fracture, the acromion index, and arm transplantation


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 11 | Pages 1513 - 1517
1 Nov 2011
Singh JA Sperling JW Cofield RH

Our objective was to examine the rate of revision and its predictive factors in patients undergoing total shoulder arthroplasty (TSA). We used prospectively collected data from the Mayo Clinic Total Joint Registry to examine five-, ten- and 20-year revision-free survival following TSA and the predictive factors. We examined patient characteristics (age, gender, body mass index, comorbidity), implant fixation (cemented versus uncemented), American Society of Anesthesiologists class and underlying diagnosis. Univariate and multivariable adjusted hazard rates were calculated using Cox regression analysis. A total of 2207 patients underwent 2588 TSAs. Their mean age was 65.0 years (19 to 91) and 1163 (53%) were women; osteoarthritis was the underlying diagnosis in 1640 shoulders (63%). In all, 212 TSAs (8.2%) were revised during the follow-up period. At five, ten and 20 years, survival rates were 94.2% (95% confidence interval (CI) 93.2 to 95.3), 90.2% (95% CI 88.7 to 91.7) and 81.4% (95% CI 78.4 to 84.5), respectively. In multivariable analyses men had a higher hazard ratio of revision of 1.72 (95% CI 1.28 to 2.31) (p < 0.01) compared with women, and those with rotator cuff disease had a hazard ratio of 4.71 (95% CI 2.09 to 10.59) (p < 0.001) compared with patients with rheumatoid arthritis. We concluded that male gender and rotator cuff disease are independent risk factors for revision after TSA. Future studies are needed to understand the biological rationale for these differences.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 1 | Pages 21 - 24
1 Jan 2005
Sierra RJ Trousdale RT Cabanela ME

We surveyed 343 young women with 420 total hip arthroplasties (THAs) regarding pregnancy and childbirth after THA. The mean age at surgery was 35 years (18 to 45). The mean length of follow-up after the initial arthroplasty was 16 years (6 to 27).

Of these 343 women, 47 (13.7%) had a successful pregnancy after their primary THA. The first baby after a THA was delivered vaginally in 30 patients and by Caesarean section in 17. Of the 343 patients, 138 underwent a revision. For the entire series, the risk of revision at five years was 5%, at ten years 24%, and at 20 years 50%. After adjusting for age at surgical intervention, the risk of revision was not significantly associated with childbirth. Of the 47 patients who had a successful pregnancy, 28 (60%) noted an increase in pain in the hip during pregnancy and ten of these patients had persistent pain after their pregnancy. Seven patients complained of pain in the groin in the replaced hip after childbirth. At the time of this survey, five of these patients (70%) had had revision THA.

Childbirth is not affected by the presence of a THA. Pregnancy after THA is not associated with decreased survival of the prosthesis. Pain in the hip is common during pregnancy in these patients. Pain in the groin which persists after delivery commonly leads to revision of the THA.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 3 | Pages 387 - 392
1 Mar 2010
Kasten P Pape G Raiss P Bruckner T Rickert M Zeifang F Loew M

We have investigated the mid-term outcome of total shoulder replacement using a keeled cemented glenoid component and a modern cementing technique with regard to the causes of failure and loosening of the components.

Between 1997 and 2003 we performed 96 total shoulder replacements on 88 patients, 24 men and 64 women with a mean age of 69.7 years (31 to 82). The minimum follow-up was five years and at the time of review 87 shoulders (77 patients) were examined at a mean follow-up of 89.1 months (60 to 127). Cumulative survival curves were generated with re-operations (accomplished and planned), survivorship of the proshesis, loosening of the glenoid (defined as tilt > 5° or subsidence > 5 mm), the presence of radiolucent lines and a Constant score of < 30 as the endpoints.

There were two re-operations not involving revision of the implants and the survival rate of the prosthesis was 100.0% for the follow-up period, with an absolute Constant score of > 30 as the endpoint the survival rate was 98%. Radiological glenoid loosening was 9% after five years, and 33% after nine years. There was an incidence of 8% of radiolucent lines in more than three of six zones in the immediate post-operative period, of 37.0% after the first year which increased to 87.0% after nine years. There was no correlation between the score of Boileau and the total Constant score at the latest follow-up, but there was correlation between glenoid loosening and pain (p = 0.001).

We found that total shoulder replacement had an excellent mid-term survivorship and clinical outcome. The surgical and cementing techniques were related to the decrease in radiolucent lines around the glenoid compared with earlier studies. One concern, however, was the fact that radiolucent lines increased over time and there was a rate of glenoid loosening of 9% after five years and 33% after nine years. This suggests that the design of the glenoid component, and the implantation and cementing techniques may need further improvement.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 4 | Pages 460 - 465
1 Apr 2008
Strickland JP Sperling JW Cofield RH

While frequently discussed as a standard treatment for the management of an infected shoulder replacement, there is little information on the outcome of two-stage re-implantation.

We examined the outcome of 17 consecutive patients (19 shoulders) who were treated between 1995 and 2004 with a two-stage re-implantation for the treatment of a deep-infection after shoulder replacement. All 19 shoulders were followed for a minimum of two years or until the time of further revision surgery. The mean clinical follow-up was for 35 months (24 to 80). The mean radiological follow-up was 27 months (7 to 80). There were two excellent results, four satisfactory and 13 unsatisfactory. In 12 of the 19 shoulders (63%) infection was considered to be eradicated. The mean pain score improved from 4.2 (3 to 5 (out of 5)) to 1.8 (1 to 4). The mean elevation improved from 42° (0° to 140°) to 89° (0° to 165°), mean external rotation from 30° (0° to 90°) to 43° (0° to 90°), and mean internal rotation from the sacrum to L5. There were 14 complications.

Our study suggests that two-stage re-implantation for an infected shoulder replacement is associated with a high rate of unsatisfactory results, marginal success at eradicating infection and a high complication rate.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 1 | Pages 75 - 81
1 Jan 2009
Cil A Veillette CJH Sanchez-Sotelo J Sperling JW Schleck C Cofield RH

Between 1976 and 2004, 38 revision arthroplasties (35 patients) were performed for aseptic loosening of the humeral component. The mean interval from primary arthroplasty to revision was 7.1 years (0.4 to 16.6). A total of 35 shoulders (32 patients) were available for review at a mean follow-up of seven years (2 to 19.3).

Pre-operatively, 34 patients (97%) had moderate or severe pain; at final follow-up, 29 (83%) had no or only mild pain (p < 0.0001). The mean active abduction improved from 88° to 107° (p < 0.01); and the mean external rotation from 37° to 46° (p = 0.27). Excellent or satisfactory results were achieved in 25 patients (71%) according to the modified Neer rating system. Humeral components were cemented in 29, with ingrowth implants used in nine cases. There were 19 of standard length and 17 were longer (two were custom replacements and are not included). Bone grafting was required for defects in 11 humeri. Only two glenoid components were left unrevised. Intra-operative complications included cement extrusion in eight cases, fracture of the shaft of the humerus is two and of the tuberosity in four. There were four re-operations, one for recurrent humeral loosening, with 89% survival free of re-operations at ten years.

Revision surgery for aseptic loosening of the humeral component provides reliable pain relief and modest improvement of movement, although there is a substantial risk of intra-operative complications. Revision to a total shoulder replacement gives better results than to a hemiarthroplasty.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 4 | Pages 496 - 500
1 Apr 2005
Mileti J Sperling JW Cofield RH Harrington JR Hoskin TL

There are theoretical and practical advantages to modular rather than monoblock designs of prostheses for shoulder arthroplasty, but there are no reported studies which specifically compare the clinical and radiological results of their use. We have compared the results of unconstrained total shoulder arthroplasty for osteoarthritis using both types of implant. The monoblock design was used between 1992 and 1995 and the modular design after 1995. Both had cemented all-polyethylene glenoids, the monoblock with matched and the modular with mismatched radii of curvature. There were 34 consecutive shoulders in each group with a mean follow-up of 6.1 years in the first and 5.2 years in the second.

There were no significant differences in improvement of pain scores, active elevation, external rotation, internal rotation, patient satisfaction, or the Neer ratings between the two groups. Two of 28 glenoid components in the first group and six of 30 in the second met the criteria for being radiologically at risk for loosening (p = 0.25). There were no significant differences in clinical outcome or radiological changes between the first- and second-generation designs of implant for shoulder arthroplasty.