Surgical treatment of hip fracture is challenging; the bone is porotic and fixation failure can be catastrophic. Novel implants are available which may yield superior clinical outcomes. This study compared the clinical effectiveness of the novel X-Bolt Hip System (XHS) with the sliding hip screw (SHS) for the treatment of fragility hip fractures. We conducted a multicentre, superiority, randomized controlled trial. Patients aged 60 years and older with a trochanteric hip fracture were recruited in ten acute UK NHS hospitals. Participants were randomly allocated to fixation of their fracture with XHS or SHS. A total of 1,128 participants were randomized with 564 participants allocated to each group. Participants and outcome assessors were blind to treatment allocation. The primary outcome was the EuroQol five-dimension five-level health status (EQ-5D-5L) utility at four months. The minimum clinically important difference in utility was pre-specified at 0.075. Secondary outcomes were EQ-5D-5L utility at 12 months, mortality, residential status, mobility, revision surgery, and radiological measures.Aims
Methods
A group of 109 patients with unilateral low back pain for over three months were randomised to receive one of three types of injection treatment: cortisone and local anaesthetic injected into two facet joints (28), the same mixture around two facet joints (39), or physiological saline into two facet joints (42). The effect of the treatment was evaluated in relation to work attendance, pain, disability and movements of the lumbar spine. Patients were examined one hour and two and six weeks after treatment and also completed a questionnaire after three months. A significant improvement was observed in work attendance, pain and disability scores, but this was independent of the treatment given and movements of the lumbar spine were not improved. Of the 70 patients with initial pain relief after injection, 36% reported persisting benefit at the three month follow-up, independent of the mode of treatment given. We conclude that facet joint injection is a non-specific method of treatment and the good results depend on a tendency to spontaneous regression and to the psychosocial aspects of back pain.
1. A systematic collection of the clinical findings in fifty patients with pyrophosphate synovitis,among some 300 patients with obscure disorder of the knee, has been made over a period of eighteen months. The numbers of men and women were equal, the mean age being seventy years (range thirty-seven to ninety), and the mean age at the onset of symptoms fifty-nine years. 2. A difference in the clinical picture between the sexes was found. In men an acute synovitis predominated, in women chronic joint complaints. 3. A high incidence of accompanying disease was found, but none had a significant relationship to the arthropathy, although the high frequency (20 per cent) of synovitis following an acute severe illness of some other kind was striking. 4. No specific radiological sign except for calcifications in articular cartilage and menisci was found in these patients, and no relationship to osteoarthrosis could be established. 5. The great variability of symptoms and the surprisingly high incidence attracts attention to pyrophosphate synovitis as a cause of joint symptoms, especially in elderly patients.
Arthroplasty of the hip using an interposed multi-layered cap of amniotic membrane is reported in 28 patients with tuberculous arthritis. The disease had been present from one to seven years, and five patients had multiple discharging sinuses. Follow-up was from 30 to 46 months. Amniotic tissue caused no inflammatory reaction, or obvious rejection, and 25 patients were free of symptoms, with a good range of movement and a stable joint. The three failures were caused by dislocation, fracture of the femoral neck and extra-articular bone formation respectively. Amniotic arthroplasty seems to be capable of providing a painless, mobile and stable joint in patients with tuberculosis of the hip.
Therapeutic injection of facet joints is now widely practised, but British experience has been infrequently reported. We studied the results of injecting facet joints with a corticosteroid preparation in 50 patients suffering from the "facet syndrome". Our series included a number of extra-articular injections and these "failed injections" provide a useful control group. Results indicate that only intra-articular injections are effective; certainty of joint penetration can be ensured only by the routine use of joint arthrography.
Low lumbar pain with radiation into the leg is a common symptom pattern caused by a number of pathological processes. Isolated disc resorption is one such entity which can be readily identified and is amenable to surgical treatment. This study consisted of two groups of patients. Group I were 50 patients suffering from isolated disc resorption at L5--S1 with ill-defined low backache extending into the buttocks and down one or both legs, but not into the feet. Clinical signs of nerve root dysfunction were found in 16 per cent of patients. Radiographic changes with loss of disc height, facet over-riding and intrusion into the nerve root canal and intervertebral foramen were common and frequently associated with sclerosis of the vertebral end-plate. Group II were a series of 45 patients with isolated disc resorption independently reviewed an average of 45 months after surgical decompression of the S1 (98 per cent) or lower lumbar nerve roots. Based on objective grading by the clinician and subjective assessment by the patient complete success was achieved in 62 per cent of the patients and partial success in 24 per cent. Provided there is full appreciation of the pathological anatomy, strict diagnostic criteria and meticulous surgery, decompression of the nerve root canal is a useful surgical procedure in severely disabled patients suffering from isolated disc resorption.
We have developed an apparatus to measure the anteroposterior stability of the knee to forces of up to 250 N, applied at 20 degrees of flexion. We measured anterior laxity at 200 N, anterior stiffness at 50 N and total laxity at +/- 200 N. A study of cadaveric knees revealed that the soft tissues surrounding the bones had a significant influence on the force-displacement curve, and emphasised that differences between injured and normal pairs of knees are much more important than the absolute values of the parameters. In 61 normal volunteers we found no significant left to right differences in anterior laxity at 200 N and anterior stiffness at 50 N. In 92 patients with unilateral anterior cruciate deficiency there were significant differences (p less than 0.0005) in anterior laxity, anterior stiffness and total laxity, the injured-normal differences averaging 6.7 mm, 1.3 N/mm, and 8.1 mm respectively.
In order to determine the usefulness of MRI in assessing autologous chondrocyte implantation (ACI) the first 57 patients (81 chondral lesions) with a 12-month review were evaluated clinically and with specialised MRI at three and 12 months. Improvement 12 months after operation was found subjectively (37.6 to 51.9) and in knee function levels (from 85% International Cartilage Repair Society (ICRS) III/IV to 61% I/II). The International Knee Documentation Committee (IKDC) scores showed an initial deterioration at three months (56% IKDC A/B) but marked improvement at 12 months (88% A/B). The MRI at three months showed 82% of patients with at least 50% defect fill, 59% with a normal or nearly normal signal at repair sites, 71% with a mild or no effusion and 80% with a mild or no underlying bone-marrow oedema. These improved at 12 months to 93%, 93%, 94% and 91%, respectively. The overall MR score at 12 months suggested production of normal or nearly normal cartilage in 82%, corresponding to a subjective improvement in 81% of patients and 88% IKDC A/B scores. Second-look surgery and biopsies in 15 patients (22 lesions) showed a moderate correlation of MRI with visual scoring; 70% of biopsies showed hyaline and hyaline-like cartilage. Thus, MRI at 12 months is a reasonable non-invasive means of assessment of ACI.
Biodegradable implants made from polyglycolic and polylactic acid co-polymers undergo degradation by hydrolysis which results in loss of their mechanical strength. The degradation of 1.5 mm polyglycolide rods (Biofix) was studied after intramedullary and subcutaneous implantation in rabbits. Two weeks after implantation there was a 73% reduction in strength of the intramedullary implants and a 64% reduction in the subcutaneous implants. Polyglycolide implants were compared with Kirschner wires for intramedullary fixation of extra-articular fractures in the hand. In one group of patients fractures were fixed with a 1.5 mm intramedullary rod and in a similar group a Kirschner wire was used. In both a wire loop was added for extra fixation. At six months there was no significant difference between the two groups. There were no allergic reactions to the polyglycolide implants.
We performed a randomised trial on 37 hips (33 patients) with early-stage osteonecrosis (ON). After the initial clinical evaluation, including plain radiography and MRI, 18 hips were randomly assigned to a core-decompression group and 19 to a conservatively-treated group. All the patients were regularly followed up by clinical evaluation, plain radiography and MRI at intervals of three months. Hip pain was relieved in nine out of ten initially symptomatic hips in the core-decompression group but persisted in three out of four initially painful hips in the conservatively-treated group at the second assessment (p <
0.05). At a minimum follow-up of 24 months, 14 of the 18 core-decompressed hips (78%) and 15 of the 19 non-operated hips (79%) developed collapse of the femoral head. By survival analysis, there was no significant difference in the time to collapse between the two groups (log-rank test p = 0.79). Core decompression may be effective tin symptomatic relief, but is of no greater value than conservative management in preventing collapse in early osteonecrosis of the femoral head.
We report the use of a new method of locked intramedullary flexible osteosynthesis (LIFO) in the treatment of 118 unstable fractures of the femur and tibia. The implant utilises a set of flexible pins with a separate locking device for their proximal ends. The LIFO system proved capable of stabilising unstable fractures, and most of the complications occurred during the early testing. At follow-up, 19 of 21 femoral fractures had healed; one become infected and one showed defective callus. Of the 78 tibial shaft fractures, five failed to consolidate and five had inadequate callus. Reaming of the tibial medullary canal was never necessary. Of 28 open fractures only one became infected. The system was most difficult to use in comminuted distal fractures of the tibia, with five failures of healing in 19 cases; these cases require considerable technical proficiency. The flexibility of the system appears to promote earlier consolidation of open fractures, and normal consolidation times for fractures with interfragmentary gaps of up to 10 to 12 mm. A comparative study of callus density in tibial fractures showed a mean improvement of 50 days in cases treated by the LIFO system compared with similar cases treated by rigid nailing.
A consecutive series of 31 displaced fractures of the proximal humerus were randomly selected for treatment either by closed manipulation or by transcutaneous reduction and external fixation. Follow-up assessed the quality of reduction and healing as well as the functional outcome. The external fixation method gave better reduction, safer healing and superior function.
Failure of union of the tibia with a large defect is difficult to treat, especially in the presence of sepsis and adherent scars. Conventional methods of fixation and bone grafting are not easily applicable. Experiments on Macaca monkeys showed that a vascularised pedicle graft of the shaft of the ipsilateral fibula could be fixed across a defect in the tibia and remain viable, even if it was isolated from surrounding soft tissues. Transfer of part of the shaft of the ipsilateral fibula on a vascular and muscle pedicle was carried out in 11 patients with large tibial defects and sepsis. There was one failure because of severe infection, but the other 10 patients gained sound union in about four months. The tibia was then protected by a caliper for the 18 months of full reconstitution. The bone infection healed and there was no evidence of avascular necrosis. Although the salvaged limbs were scarred, stiff and ugly, none of the patients suffered from pain, recurrent oedema or persistent infection.
Aims. People with severe, persistent low back pain (LBP) may be offered lumbar spine fusion surgery if they have had insufficient benefit from recommended non-surgical treatments. However, National Institute for Health and Care Excellence (NICE) 2016 guidelines recommended not offering spinal fusion surgery for adults with LBP, except as part of a randomized
Aims. Complete ruptures of the ulnar collateral ligament (UCL) of the thumb are a common injury, yet little is known about their current management in the UK. The objective of this study was to assess the way complete UCL ruptures are managed in the UK. Methods. We carried out a multicentre, survey-based cross-sectional study in 37 UK centres over a 16-month period from June 2022 to September 2023. The survey results were analyzed descriptively. Results. A total of 37 centres participated, of which nine were tertiary referral hand centres and 28 were district general hospitals. There was a total of 112 respondents (69 surgeons and 43 hand therapists). The strongest influence on the decision to offer surgery was the lack of a firm ‘endpoint’ to stressing the metacarpophalangeal joint (MCPJ) in either full extension or with the MCPJ in 30° of flexion. There was variability in whether additional imaging was used in managing acute UCL injuries, with 46% routinely using additional imaging while 54% did not. The use of a bone anchor was by far the most common surgical option for reconstructing an acute ligament avulsion (97%, n = 67) with a transosseous suture used by 3% (n = 2). The most common duration of immobilization for those managed conservatively was six weeks (58%, n = 65) and four weeks (30%, n = 34). Most surgeons (87%, n = 60) and hand therapists (95%, n = 41) would consider randomizing patients with complete UCL ruptures in a future
The December 2022 Trauma Roundup. 360. looks at: Anterior approach for acetabular fractures using anatomical plates; Masquelet–Ilizarov for the management of bone loss post debridement of infected tibial nonunion; Total hip arthroplasty – better results after low-energy displaced femoral neck fracture in young patients; Unreamed intramedullary nailing versus external fixation for the treatment of open tibial shaft fractures in Uganda: a randomized