We describe our technique and rationale using
hybrid fixation for primary total hip arthroplasty (THA) at the Hospital
for Special Surgery. Modern uncemented acetabular components have
few screw holes, or no holes, polished inner surfaces, improved
locking mechanisms, and maximised thickness and shell-liner conformity. Uncemented
sockets can be combined with highly cross-linked polyethylene liners,
which have demonstrated very low wear and osteolysis rates after
ten to 15 years of implantation. The results of cement fixation
with a smooth or polished surface finished stem have been excellent,
virtually eliminating complications seen with cementless fixation
like peri-operative femoral fractures and thigh pain. Although mid-term
results of modern cementless stems are encouraging, the long-term
data do not show reduced revision rates for cementless stems compared
with cemented smooth stems. In this paper we review the conduct
of a hybrid THA, with emphasis on pre-operative planning, surgical
technique, hypotensive epidural anaesthesia, and intra-operative
physiology. Cite this article:
Direct anterior approaches to the hip have gained
popularity as a minimally invasive method when performing primary
total hip replacement (THR). A retrospective review of a single
institution joint registry was performed in order to compare patient
outcomes after THR using the Anterior Supine Intermuscular (ASI)
approach Cite this article
Pain, swelling and inflammation are expected
during the recovery from total knee arthroplasty (TKA) surgery.
The severity of these factors and how a patient copes with them
may determine the ultimate outcome of a TKA. Cryotherapy and compression
are frequently used modalities to mitigate these commonly experienced
sequelae. However, their effect on range of motion, functional testing,
and narcotic consumption has not been well-studied. A prospective, multi-center, randomised trial was conducted to
evaluate the effect of a cryopneumatic device on post-operative
TKA recovery. Patients were randomised to treatment with a cryopneumatic
device or ice with static compression. A total of 280 patients were
enrolled at 11 international sites. Both treatments were initiated
within three hours post-operation and used at least four times per
day for two weeks. The cryopneumatic device was titrated for cooling
and pressure by the patient to their comfort level. Patients were evaluated by physical therapists blinded to the
treatment arm. Range of motion (ROM), knee girth, six minute walk
test (6MWT) and timed up and go test (TUG) were measured pre-operatively,
two- and six-weeks post-operatively. A visual analog pain score
and narcotic consumption was also measured post-operatively. At two weeks post-operatively, both the treatment and control
groups had diminished ROM and function compared to pre-operatively.
Both groups had increased knee girth compared to pre- operatively.
There was no significant difference in ROM, 6MWT, TUG, or knee girth
between the 2 groups. We did find a significantly lower amount of
narcotic consumption (509 mg morphine equivalents) in the treatment
group compared with the control group (680 mg morphine equivalents)
at up to two weeks postop, when the cryopneumatic device was being
used (p <
0.05). Between two and six weeks, there was no difference
in the total amount of narcotics consumed between the two groups.
At six weeks, there was a trend toward a greater distance walked
in the 6MWT in the treatment group (29.4 meters A cryopneumatic device used after TKA appeared to decrease the
need for narcotic medication from hospital discharge to 2 weeks
post-operatively. There was also a trend toward a greater distance
walked in the 6MWT. Patient satisfaction with the cryopneumatic
cooling regimen was significantly higher than with the control treatment.
A moderator and panel of five experts led an
interactive session in discussing five challenging and interesting patient
case presentations involving surgery of the hip. The hip pathologies
reviewed included failed open reduction internal fixation of subcapital
femoral neck fracture, bilateral hip disease, evaluation of pain
after metal-on-metal hip arthroplasty, avascular necrosis, aseptic
loosening secondary to osteolysis and polyethylene wear, and management
of ceramic femoral head fracture.
Symptomatic cobalt toxicity from a failed total
hip replacement is a rare but devastating complication. It has been reported
following revision of fractured ceramic components, as well as in
patients with failed metal-on-metal articulations. Potential clinical
findings include fatigue, weakness, hypothyroidism, cardiomyopathy,
polycythaemia, visual and hearing impairment, cognitive dysfunction,
and neuropathy. We report a case of an otherwise healthy 46-year-old
patient, who developed progressively worsening symptoms of cobalt
toxicity beginning approximately six months following synovectomy
and revision of a fractured ceramic-on-ceramic total hip replacement
to a metal-on-polyethylene bearing. The whole blood cobalt levels
peaked at 6521 µg/l. The patient died from cobalt-induced cardiomyopathy.
Implant retrieval analysis confirmed a loss of 28.3 g mass of the
cobalt–chromium femoral head as a result of severe abrasive wear
by ceramic particles embedded in the revision polyethylene liner.
Autopsy findings were consistent with heavy metal-induced cardiomyopathy. We recommend using new ceramics at revision to minimise the risk
of wear-related cobalt toxicity following breakage of ceramic components. Cite this article:
In 1994, a register for cerebral palsy and a health-care programme were started in southern Sweden with the aim of preventing dislocation of the hip in children with cerebral palsy. It involved all children with cerebral palsy born in 1992 or later. None of the 206 affected children born between 1992 and 1997 has developed a dislocation following the introduction of the prevention programme. Another 48 children moved into the area and none developed any further dislocation. Of the 251 children with cerebral palsy, aged between five and 11 years, living in the area on January 1, 2003, only two had a dislocated hip. One boy had moved into the area at age of nine with a dislocation and a girl whose parents chose not to participate in the programme developed bilateral dislocation. One boy, whose condition was considered to be too poor for preventative surgery, developed a painful dislocation of the hip at the age of five years and died three years later. Eight of 103 children in a control group, consisting of all children with cerebral palsy living in the area between 1994 and 2002, and born between 1990 and 1991, developed a dislocation of the hip before the age of six years. The decreased incidence of dislocation after the introduction of the prevention programme was significant (p <
0.001). Dislocation of the hip in cerebral palsy remains a serious problem, and prevention is important. Our screening programme and early intervention when lateral displacement of the femoral head was detected appear to be successful.
We reviewed the outcome in 24 children with bilateral spastic cerebral palsy aged seven years or younger for whom surgery was recommended between 1999 and 2005 following gait analysis. A total of 13 children (operative group) had surgery and the remaining 11 (control group) did not, for family or administrative reasons. The operative group had at least two post-operative gait analyses at yearly intervals, with eight children having a third and six children a fourth. The control group had a second analysis after a mean interval of 1.5 years (95% confidence interval 1.1 to 1.9). In the operative group, the Gillette gait index, the ranges of movement in the lower limb joint and knee extension in stance improved following surgery, and this was maintained overall at the second post-operative analysis. The minimum knee flexion in stance in the control group increased between analyses. These results suggest that surgical intervention in selected children can result in improvements in gait and function in the short to medium term compared with non-operative management.
Custom-made intercalary endoprostheses may be used for the reconstruction of diaphyseal defects following the resection of bone tumours. The aim of this study was to determine the survival of intercalary endoprostheses with a lap joint design, and to evaluate the clinical results, complications and functional outcome. We retrospectively reviewed six consecutive patients, three of whom underwent limb salvage with intercalary endoprostheses of the tibia, two of the femur, and one of the humerus. Their mean age was 42 years (28 to 64). The mean follow-up was 21.6 months (9 to 58). The humeral prosthesis required revision at 14 months owing to aseptic loosening. There were no implant-related failures. Musculoskeletal Tumour Society functional outcome scores indicated that patients achieved 90% of premorbid function. Custom intercalary endoprostheses result in reconstructions comparable with, if not better than, those of allografts. Using this design of implant reduces the incidence of early complications and difficulties experienced with previous versions.
A percutaneous supramalleolar osteotomy with multiple drill holes and closed osteoclasis was used to correct rotational deformities of the tibia in patients with cerebral palsy. The technique is described and the results in 247 limbs (160 patients) are reported. The mean age at the time of surgery was 10.7 years (4 to 20). The radiographs were analysed for time to union, loss of correction, and angulation at the site of the osteotomy. Bone healing was obtained in all patients except one in a mean period of seven weeks (5 to 12). Malunion after loss of reduction at the site of the osteotomy developed in one tibia. Percutaneous supramalleolar osteotomy of the tibia is a safe and simple surgical procedure.
We report the clinical and radiological outcome of 86 revisions of cemented hip arthroplasties using JRI-Furlong hydroxyapatite-ceramic-coated acetabular and femoral components. The acetabular component was revised in 62 hips and the femoral component in all hips. The mean follow-up was 12.6 years and no patient was lost to follow-up. The mean age of the patients was 71.2 years. The mean Harris hip and Oxford scores were 82 (59 to 96) and 23.4 (14 to 40), respectively. The mean Charnley modification of the Merle d’Aubigné and Postel score was 5 (3 to 6) for pain, 4.9 (3 to 6) for movement and 4.4 (3 to 6) for mobility. Migration of the acetabular component was seen in two hips and the mean acetabular inclination was 42.6°. The mean linear polyethylene wear was 0.05 mm/year. The mean subsidence of the femoral component was 1.9 mm and stress shielding was seen in 23 (28%) with bony ingrowth in 76 (94%). Heterotopic ossification was seen in 12 hips (15%). There were three re-revisions, two for deep sepsis and one for recurrent dislocation and there were no re-revisions for aseptic loosening. The mean EuroQol EQ-5D description scores and health thermometer scores were 0.69 (0.51 to 0.89) and 79 (54 to 95), respectively. With an end-point of definite or probable loosening, the probability of survival at 12 years was 93.9% and 95.6% for the acetabular and femoral components, respectively. Overall survival at 12 years, with removal or further revision of either component for any reason as the end-point, was 92.3%. Our study supports the continued use of this arthroplasty and documents the durability of hydroxyapatite-ceramic-coated components.