Advertisement for orthosearch.org.uk
Results 41 - 60 of 918
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 494 - 498
1 Apr 2009
Cho NH Kim S Kwon D Kim HA

There are few data available regarding the association between hallux valgus and pain or functional limitation. We determined the prevalence of hallux valgus in a rural Korean population aged between 40 and 69 years, and its association with pain and function. A total of 563 subjects was examined using the foot health status questionnaire, the Short Form-36 questionnaire and weight-bearing anteroposterior radiographs. Hallux valgus was present in 364 subjects (64.7%). It did not significantly correlate with age and was more common in women. Of the 364 subjects, 48 (13.2%) had moderate or greater deformity, defined as a hallux valgus angle > 25°. This was significantly associated with pain, worse function and worse foot health. The putative risk factors associated with painful hallux valgus were female gender, low educational attainment and the presence of pain in the knee


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 2 | Pages 197 - 201
1 Mar 1990
Engesaeter L Wilson D Nag D Benson M

One-hundred newborn children at high risk of hip instability were prospectively assessed clinically and by ultrasound. The decision to treat was based only on the clinical examination. At the age of three months all the children were evaluated clinically and with an anteroposterior radiograph of the pelvis. None of the standard ultrasound measurements of acetabular depth and femoral head cover correlated with the outcome at three months. Dynamic assessment of stability was the only ultrasound technique that had a significant relation with outcome


The Journal of Bone & Joint Surgery British Volume
Vol. 62-B, Issue 3 | Pages 346 - 349
1 Aug 1980
Johnson F Leitl S Waugh W

An anteroposterior radiograph of the leg to include the hip and ankle, taken with the patient standing, provides an estimate of the line of load-bearing at the knee. Gait analysis may be used to determine the way in which the load in the knee is shared between the medial and lateral compartments during normal walking. A comparison of the results from the two methods, carried out on a group of 47 patients, led to the conclusion that both calculations are required for the successful outcome of a tibial osteotomy or a total arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 5 | Pages 751 - 756
1 Sep 1991
Sambatakakis A Wilton T Newton G

We report on the radiological findings in a series of 871 consecutive primary condylar knee replacements followed up for an average of four years. A new radiological sign has been identified, consisting of a smoothly tapering wedge of cement visible beneath the horizontal portion of the tibial component on the anteroposterior radiograph. This was found in 25.4% of our cases and appears to indicate a persistent soft-tissue imbalance following condylar arthroplasty of the knee. The cement-wedge sign was associated with a highly significant increase in radiolucent lines at the tibial cement-bone interface


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 6 | Pages 799 - 804
1 Aug 2001
Court-Brown CM Garg A McQueen MM

We have undertaken a five-year prospective study of 126 translated two-part fractures of the proximal humerus and present an analysis of the epidemiology and of the factors which affect outcome in elderly patients. The fracture has a unimodal age distribution and rarely affects adults under the age of 50 years. Analysis showed that patients with two-part translated fractures of the surgical neck tended to be independent and relatively fit, despite the fact that their mean age was 72 years. Outcome was determined by the age of each patient and the degree of translation on the initial anteroposterior radiograph. Surgery did not improve the outcome, regardless of the degree of translation


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 57 - 61
1 Jan 2007
Lee ST Song HR Mahajan R Makwana V Suh SW Lee SH

Genu varum in the achondroplastic patient has a complex and multifactorial aetiology. There is little mention in the literature of the role of fibular overgrowth. Using the ratio of fibular to tibial length as a measurement of possible fibular overgrowth, we have related it to the development of genu varum. Full-length standing anteroposterior radiographs of 53 patients with achondroplasia were analysed. There were 30 skeletally-immature and 23 skeletally-mature patients. Regression analysis was performed in order to determine if there was a causal relationship between fibular overgrowth and the various indices of alignment of the lower limb. Analysis showed that the fibular to tibial length ratio had a significant correlation with the medial proximal tibial angle and the mechanical axial deviation in the skeletally-immature group. We conclude that there is a significant relationship between fibular overgrowth and the development of genu varum in the skeletally-immature achondroplastic patient


The Journal of Bone & Joint Surgery British Volume
Vol. 58-B, Issue 3 | Pages 353 - 355
1 Aug 1976
Matev I

Two boys with entrapment of the median nerve in the elbow joint after closed reduction of a posterior dislocation with fracture of the medial epicondyle showed a characteristic radiological sign in the anteroposterior radiograph after two to three months. The sign was a depression in the cortex on the ulnar side of the distal humeral metaphysis, with interruption of the local periosteal reaction. At operation in both patients the depression was found to correspond with the place where the median nerve reached the posterior surface of the humerus. Radiographs taken after transverse section of the nerve above and below the joint capsule and end-to-end suture showed gradual disappearance of the cortical depression


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 2 | Pages 190 - 196
1 Mar 1990
Ogata S Moriya H Tsuchiya K Akita T Kamegaya M Someya M

The exact measurement of femoral head cover is essential for an assessment of reduction of congenital dislocation of the hip. We have compared standard anteroposterior radiographs with computerised tomograms and thereby classified the shape of the acetabular roof into four types. We found that the CE angle of Wiberg is a more reliable measure of head cover when the lateral point of bony condensation of the roof is chosen as the reference point rather than the edge of the bone, where these two points do not overlap. We conclude that head cover can be more accurately determined in younger children with dysplastic hips by our 'refined' CE angle, than by the original method of Wiberg


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 1 | Pages 52 - 53
1 Feb 1982
Sondergard-Petersen P Mikkelsen P

Posterior dislocation of the acromioclavicular joint with the lateral end of the clavicle locked behind the acromion has only rarely been described. This paper present such a case diagnosed two weeks after the shoulder was injured in an accident. The clavicle was locked behind the articular surface of the acromion, restricting the movement of the shoulder and causing considerable pain. Anteroposterior radiographs showed a high-riding clavicle but no gap in the joint, but the axial view showed the dislocation. At operation the coracoclavicular ligaments were found overstretched but not ruptured. As reduction of the acromioclavicular joint was not possible, the lateral end of the clavicle was resected. Although the result was perfect, we consider the correct treatment should be early closed or open reduction of the acromioclavicular joint


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1508 - 1512
1 Nov 2006
Wimsey S Pickard R Shaw G

Magnification of anteroposterior radiographs of the pelvis is variable. To improve the accuracy of templating, reliable and radiographer-friendly methods of scaling are necessary. We assessed two methods of scaling digital radiographs of the pelvis: placing a coin of known diameter in the plane of interest between the patient’s thighs, and using a caliper to measure the bony width of the pelvis. A total of 39 patients who had recently undergone hemiarthroplasty of the hip or total hip replacement were enrolled in the study. The accuracy of the methods was assessed by comparing the actual diameter of the head of the prosthesis with the measured on-screen value. The coin method was within a mean of 1.12% (0% to 2.38%) of the actual measurement, the caliper group within 6.99% (0% to 16.67%). The coin method was significantly more accurate (p < 0.001). It was also reliable and radiographer friendly. We recommend it as the method of choice for scaling radiographs of the pelvis before hip surgery


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 155 - 159
1 Feb 2007
Saudan M Saudan P Perneger T Riand N Keller A Hoffmeyer P

We examined whether a selective cyclooxygenase-2 (COX-2) inhibitor (celecoxib) was as effective as a non-selective inhibitor (ibuprofen) for the prevention of heterotopic ossification following total hip replacement. A total of 250 patients were randomised to receive celecoxib (200 mg b/d) or ibuprofen (400 mg t.d.s) for ten days after surgery. Anteroposterior radiographs of the pelvis were examined for heterotopic ossification three months after surgery. Of the 250 patients, 240 were available for assessment. Heterotopic ossification was more common in the ibuprofen group (none 40.7% (50), Brooker class I 46.3% (57), classes II and III 13.0% (16)) than in the celecoxib group (none 59.0% (69), Brooker class I 35.9% (42), classes II and III 5.1% (6), p = 0.002). Celecoxib was more effective than ibuprofen in preventing heterotopic bone formation after total hip replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 60-B, Issue 3 | Pages 345 - 352
1 Aug 1978
Denham R Bishop R

Static force transmission at the knee is analysed using measurements from radiographs showing the position of the line of body weight and also the bones of the knee in their correct orientation during function. With this technique it is possible to suggest values for a variety of forces acting at the knee. During function the degree of knee flexion is not as important as the angle that the thigh makes with the vertical. The tension in the extensor mechanism is not the same above and below the patella. Failure to recognise these two features results in fundamental errors. The patella, the effects of patellectomy and of forward displacement of the attachment of the patellar ligament are discussed. The importance of the transmission of force in the coronal plane is emphasised with particular reference to total knee replacement. It is suggested that small errors of geometry, as seen in the anteroposterior radiograph, can produce large changes of load


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 1 | Pages 130 - 133
1 Jan 1998
Takakura Y Kumai T Takaoka T Tamai S

We examined seven patients with tarsal tunnel syndrome in one foot caused by talocalcaneal coalition and a ganglion. We excised the coalition and the ganglion in six of them. All the patients had pain, sensory disturbance in the sole, and a positive Tinel’s sign. Older patients with a long history showed atrophy and weakness of the plantar muscles. Talocalcaneal coalition can be diagnosed on a plain lateral radiograph and an anteroposterior radiograph externally rotated 20°, and confirmed by CT. MRI is also useful for diagnosis. The coalitions were medial, and the ganglion had developed from the incomplete part of the coalition; it was multilocular in some patients. After resection, there was early pain relief but sensory disturbances and Tinel’s sign persisted. The postoperative results were excellent in one patient, good in four and fair in one


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 5 | Pages 739 - 742
1 Sep 1995
Farsetti P Tudisco C Caterini R Potenza V Ippolito E

We reviewed the radiographs of 49 patients with Perthes' disease at the stage of fragmentation and also after the end of skeletal growth to assess the value of the lateral pillar classification of Herring. The average age of the patients at diagnosis was 7 years 6 months and the mean follow-up was 24 years. Ten of the 11 Herring group-A hips showed good reconstruction of the femoral head. There were good results in group-B hips when the patients were less than nine years of age at diagnosis. All 11 group-C patients showed hip deformity at follow-up. The Herring classification provides a valid long-term prognosis in Perthes' disease, although age at diagnosis is also an important prognostic factor. The classification is relatively easy to apply, is reliable, and requires only an anteroposterior radiograph taken during the fragmentation stage of the disease


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 3 | Pages 416 - 419
1 Apr 2000
Kido T Itoi E Konno N Sano A Urayama M Sato K

We investigated the function of biceps in 18 patients (19 shoulders) with lesions of the rotator cuff. Their mean age was 59 years. Another series of 18 patients (19 shoulders) with normal rotator cuffs as seen on MRI acted as a control group. Their mean age was 55 years. A brace was used to maintain contraction of biceps during elevation. Anteroposterior radiographs were obtained with the arm elevated at 0°, 45° and 90° with and without contraction of biceps. The distance between the centre of the head of the humerus and the glenoid was compared in the two groups. We found that in the group with tears there was significantly greater proximal migration of the head of the humerus at 0° and 45° of elevation without contraction of biceps but depression of the head of the humerus at 0°, 45° and 90° when biceps was functioning. We conclude that biceps is an active depressor of the head of the humerus in shoulders with lesions of the rotator cuff


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 4 | Pages 611 - 617
1 May 2003
Tingart MJ Apreleva M von Stechow D Zurakowski D Warner JJP

The operative treatment of fractures of the proximal humerus can be complicated by poor bone quality. Our aim was to evaluate a new method which allows prediction of the bone quality of the proximal humerus from radiographs. Anteroposterior radiographs were taken of 19 human cadaver humeri. The cortical thickness was measured at two levels of the proximal humeral diaphysis. The bone mineral density (BMD) was determined for the humeral head (HH), the surgical neck (SN), the greater tuberosity (GT) and lesser tuberosity (LT) using dual-energy x-ray absorptiometry. The mean cortical thickness was 4.4 ± 1.0 mm. Specimens aged 70 years or less had a significantly higher cortical thickness than those aged over 70 years. A significant positive correlation was found between cortical thickness and the BMD for each region of interest. The cortical thickness of the proximal diaphysis is a reliable predictor of the bone quality of the proximal humerus


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 8 | Pages 1072 - 1078
1 Aug 2010
Grammatopoulos G Pandit H Glyn-Jones S McLardy-Smith P Gundle R Whitwell D Gill HS Murray DW

Pseudotumours are a rare complication of hip resurfacing. They are thought to be a response to metal debris which may be caused by edge loading due to poor orientation of the acetabular component. Our aim was to determine the optimal acetabular orientation to minimise the risk of pseudotumour formation. We matched 31 hip resurfacings revised for pseudotumour formation with 58 controls who had a satisfactory outcome from this procedure. The radiographic inclination and anteversion angles of the acetabular component were measured on anteroposterior radiographs of the pelvis using Einzel-Bild-Roentgen-Analyse software. The mean inclination angle (47°, 10° to 81°) and anteversion angle (14°, 4° to 34°) of the pseudotumour cases were the same (p = 0.8, p = 0.2) as the controls, 46° (29° to 60°) and 16° (4° to 30°) respectively, but the variation was greater. Assuming an accuracy of implantation of ± 10° about a target position, the optimal radiographic position was found to be approximately 45° of inclination and 20° of anteversion. The incidence of pseudotumours inside the zone was four times lower (p = 0.007) than outside the zone. In order to minimise the risk of pseudotumour formation we recommend that surgeons implant the acetabular component at an inclination of 45° (± 10) and anteversion of 20° (± 10) on post-operative radiographs. Because of differences between the radiographic and the operative angles, this may be best achieved by aiming for an inclination of 40° and an anteversion of 25°


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 9 | Pages 1158 - 1163
1 Sep 2009
Clauss M Luem M Ochsner PE Ilchmann T

The original forged Müller straight stem (CoNiCr) has shown excellent ten- to 15-year results. We undertook a long-term survival analysis with special emphasis on radiological changes within a 20-year period of follow-up. In all, 165 primary total hip replacements, undertaken between July 1984 and June 1987 were followed prospectively. Clinical follow-up included a standardised clinical examination, and radiological assessment was based on a standardised anteroposterior radiograph of the pelvis, which was studied for the presence of osteolysis, debonding and cortical atrophy. Survival of the stem with revision for any reason was 81% (95% confidence interval (CI), 76 to 86) at 20 years and for aseptic loosening 87% (95% CI, 82 to 90). At the 20-year follow-up, 15 of the surviving 36 stems showed no radiological changes. Debonding (p = 0.005), osteolysis (p = 0.003) and linear polyethylene wear (p = 0.016) were associated with aseptic loosening, whereas cortical atrophy was not associated with failure (p = 0.008). The 20-year results of the Müller straight stem are comparable to those of other successful cemented systems with similar follow-up. Radiological changes are frequently observed, but with a low incidence of progression, and rarely result in revision. Cortical atrophy appears to be an effect of ageing and not a sign of loosening of the femoral component


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 2 | Pages 244 - 250
1 Mar 2004
Maxwell SL Lappin KJ Kealey WD McDowell BC Cosgrove AP

We have examined the effect of arthrodiastasis on the preservation of the femoral head in older children with Perthes’ disease. We carried out a prospective trial in boys over the age of eight years and girls over seven years at the time of the onset of symptoms. The patients had minimal epiphyseal collapse and were compared with a conventionally treated, consecutive, historical control group. Arthrodiastasis was applied for approximately four months. The primary outcome measure was the extent of epiphyseal collapse at the end of the fragmentation phase. One of the 15 treated hips and nine of the 30 control hips showed a loss of height of 50% or more of the lateral epiphyseal column on the anteroposterior radiographs (Herring grade-C classification). On a Lauenstein view, one of the treated hips and 19 of the control hips showed at least a loss of height of 50% of the anterior epiphyseal column. The complications of arthrodiastasis included pin-site infection in most hips, transient joint stiffness in two, and breakage of a pin in two. The final outcome will be known when all the patients and the control group reach skeletal maturity


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 83 - 87
1 Jan 2002
Nagels J Valstar ER Stokdijk M Rozing PM

The incidence of loosening of a cemented glenoid componentin total shoulder arthroplasty, detected by means of radiolucent lines or positional shift of the component on true anteroposterior radiographs, has been reported to be between 0% and 44%. Radiolucent lines are, however, difficult to detect and to interpret because of the mobility of the shoulder girdle and the obliquity of the glenoid which hinder standardisation of radiographs. We examined radiolucencies around cemented glenoid components in 48 patients, with a mean follow-up of 5.3 years, and found progressive changes to be present predominantly at the inferior pole of the component. This may hold a clue for the mechanism of loosening of this implant. In five patients we performed an additional analysis of loosening of the glenoid component using digital roentgen stereophotogrammetric analysis (RSA). After three years, three of the five implants had loosened (migration 1.2 to 5.5 mm). In only one, with gross loosening, were the radiological signs consistent with the RSA findings. When traditional radiographs are used for assessment, the rate of early loosening is underestimated. We recommend that RSA be used for this