Advertisement for orthosearch.org.uk
Results 41 - 60 of 264
Results per page:
Bone & Joint Open
Vol. 4, Issue 5 | Pages 385 - 392
24 May 2023
Turgeon TR Hedden DR Bohm ER Burnell CD

Aims

Instability is a common cause of failure after total hip arthroplasty. A novel reverse total hip has been developed, with a femoral cup and acetabular ball, creating enhanced mechanical stability. The purpose of this study was to assess the implant fixation using radiostereometric analysis (RSA), and the clinical safety and efficacy of this novel design.

Methods

Patients with end-stage osteoarthritis were enrolled in a prospective cohort at a single centre. The cohort consisted of 11 females and 11 males with mean age of 70.6 years (SD 3.5) and BMI of 31.0 kg/m2 (SD 5.7). Implant fixation was evaluated using RSA as well as Western Ontario and McMaster Universities Osteoarthritis Index, Harris Hip Score, Oxford Hip Score, Hip disability and Osteoarthritis Outcome Score, 38-item Short Form survey, and EuroQol five-dimension health questionnaire scores at two-year follow-up. At least one acetabular screw was used in all cases. RSA markers were inserted into the innominate bone and proximal femur with imaging at six weeks (baseline) and six, 12, and 24 months. Independent-samples t-tests were used to compare to published thresholds.


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1488 - 1492
1 Nov 2015
Tansey RJ Benjamin-Laing H Jassim S Liekens K Shankar A Haddad FS

Hip and groin injuries are common in athletes who take part in high level sports. Adductor muscle tendon injuries represent a small but important number of these injuries. Avulsion of the tendons attached to the symphysis pubis has previously been described: these can be managed both operatively and non-operatively. We describe an uncommon variant of this injury, namely complete avulsion of the adductor sleeve complex: this includes adductor longus, pectineus and rectus abdominis. We go on to describe a surgical technique which promotes a full return to the pre-injury level of sporting activity. Over a period of ten years, 15 high-level athletes with an MRI-confirmed acute adductor complex avulsion injury (six to 34 days old) underwent surgical repair. The operative procedure consisted of anatomical re-attachment of the avulsed tissues in each case and mesh reinforcement of the posterior inguinal wall in seven patients. All underwent a standardised rehabilitation programme, which was then individualised to be sport-specific. One patient developed a superficial wound infection, which was successfully treated with antibiotics. Of the 15 patients, four complained of transient local numbness which resolved in all cases. All patients (including seven elite athletes) returned to their previous level of participation in sport. Cite this article: Bone Joint J 2015;97-B:1488–92


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 657 - 659
1 May 2013
Bunker TD Cosker TDA Dunkerley S Kitson J Smith CD

Despite the expansion of arthroscopic surgery of the shoulder, the open deltopectoral approach to the shoulder is still frequently used, for example in fracture fixation and shoulder replacement. However, it is sometimes accompanied by unexpected bleeding. The cephalic vein is the landmark for the deltopectoral interval, yet its intimate relationship with the deltoid artery, and the anatomical variations in that structure, have not previously been documented. In this study the vascular anatomy encountered during 100 consecutive elective deltopectoral approaches was recorded and the common variants described. Two common variants of the deltoid artery were encountered. In type I (71%) it crosses the interval and tunnels into the deltoid muscle without encountering the cephalic vein. However, in type II (21%) it crosses the interval, reaches the cephalic vein and then runs down, medial to and behind it, giving off several small arterial branches that return back across the interval to the pectoralis major. Several minor variations were also seen (8%). These variations in the deltoid artery have not previously been described and may lead to confusion and unexpected bleeding during this standard anterior surgical approach to the shoulder. Cite this article: Bone Joint J 2013;95-B:657–9


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 130 - 136
1 Mar 2024
Morlock M Perka C Melsheimer O Kirschbaum SM

Aims

Despite higher rates of revision after total hip arthroplasty (THA) being reported for uncemented stems in patients aged > 75 years, they are frequently used in this age group. Increased mortality after cemented fixation is often used as a justification, but recent data do not confirm this association. The aim of this study was to investigate the influence of the design of the stem and the type of fixation on the rate of revision and immediate postoperative mortality, focusing on the age and sex of the patients.

Methods

A total of 333,144 patients with primary osteoarthritis (OA) of the hip who underwent elective THA between November 2012 and September 2022, using uncemented acetabular components without reconstruction shells, from the German arthroplasty registry were included in the study. The revision rates three years postoperatively for four types of stem (uncemented, uncemented with collar, uncemented short, and cemented) were compared within four age groups: < 60 years (Young), between 61 and 70 years (Mid-I), between 71 and 80 years (Mid-II), and aged > 80 years (Old). A noninferiority analysis was performed on the most frequently used designs of stem.


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 136 - 143
1 Feb 2024
van der Lelij TJN Marang-van de Mheen PJ Kaptein BL Koster LA Ljung P Nelissen RGHH Toksvig-Larsen S

Aims

The objective of this study was to compare the two-year migration and clinical outcomes of a new cementless hydroxyapatite (HA)-coated titanium acetabular shell with its previous version, which shared the same geometrical design but a different manufacturing process for applying the titanium surface.

Methods

Overall, 87 patients undergoing total hip arthroplasty (THA) were randomized to either a Trident II HA or Trident HA shell, each cementless with clusterholes and HA-coating. All components were used in combination with a cemented Exeter V40 femoral stem. Implant migration was measured using radiostereometric analysis (RSA), with radiographs taken within two days of surgery (baseline), and at three, 12, and 24 months postoperatively. Proximal acetabular component migration was the primary outcome measure. Clinical scores and patient-reported outcome measures (PROMs) were collected at each follow-up.


Bone & Joint 360
Vol. 11, Issue 6 | Pages 49 - 50
1 Dec 2022
Evans JT Whitehouse MR


Bone & Joint 360
Vol. 12, Issue 1 | Pages 45 - 47
1 Feb 2023

The February 2023 Research Roundup360 looks at: Clinical and epidemiological features of scaphoid fracture nonunion; Routine sterile glove and instrument change at the time of abdominal wound closure to prevent surgical site infection (ChEETAh); Characterization of genetic risk of end-stage knee osteoarthritis treated with total knee arthroplasty; Platelet-rich plasma or autologous blood injection for plantar fasciitis; Volume and outcomes of joint arthroplasty; The hazards of absolute belief in the p-value laid bare.


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 430 - 434
1 May 2024
Eardley WGP


Bone & Joint Research
Vol. 11, Issue 2 | Pages 91 - 101
1 Feb 2022
Munford MJ Stoddart JC Liddle AD Cobb JP Jeffers JRT

Aims

Unicompartmental and total knee arthroplasty (UKA and TKA) are successful treatments for osteoarthritis, but the solid metal implants disrupt the natural distribution of stress and strain which can lead to bone loss over time. This generates problems if the implant needs to be revised. This study investigates whether titanium lattice UKA and TKA implants can maintain natural load transfer in the proximal tibia.

Methods

In a cadaveric model, UKA and TKA procedures were performed on eight fresh-frozen knee specimens, using conventional (solid) and titanium lattice tibial implants. Stress at the bone-implant interfaces were measured and compared to the native knee.


Bone & Joint 360
Vol. 13, Issue 4 | Pages 37 - 40
2 Aug 2024

The August 2024 Children’s orthopaedics Roundup360 looks at: Antibiotic prophylaxis and infection rates in paediatric supracondylar humerus fractures; Clinical consensus recommendations for the non-surgical treatment of children with Perthes’ disease in the UK; Health-related quality of life in idiopathic toe walkers: a multicentre prospective cross-sectional study; Children with spinal dysraphism: a systematic review of reported outcomes; No delay in age of crawling, standing, or walking with Pavlik harness treatment: a prospective cohort study; No value found with routine early postoperative radiographs after implant removal in paediatric patients; What do we know about the natural history of spastic hip dysplasia and pain in total-involvement cerebral palsy?; Evaluating the efficacy and safety of preoperative gallows traction for hip open reduction in infants


Bone & Joint Open
Vol. 3, Issue 11 | Pages 859 - 866
4 Nov 2022
Diesel CV Guimarães MR Menegotto SM Pereira AH Pereira AA Bertolucci LH Freitas EC Galia CR

Aims

Our objective was describing an algorithm to identify and prevent vascular injury in patients with intrapelvic components.

Methods

Patients were defined as at risk to vascular injuries when components or cement migrated 5 mm or more beyond the ilioischial line in any of the pelvic incidences (anteroposterior and Judet view). In those patients, a serial investigation was initiated by a CT angiography, followed by a vascular surgeon evaluation. The investigation proceeded if necessary. The main goal was to assure a safe tissue plane between the hardware and the vessels.


Bone & Joint 360
Vol. 13, Issue 4 | Pages 31 - 35
2 Aug 2024

The August 2024 Trauma Roundup360 looks at: Does topical vancomycin prevent fracture-related infections in closed fractures undergoing open reduction and internal fixation? A randomized controlled trial; Is postoperative splinting advantageous after upper limb fracture surgery?; Does suprapatellar nailing resolve knee pain?; Locking versus non-locking plate fixation in comminuted talar neck fractures: a biomechanical study using cadaveric specimens; Revolutionizing recovery metrics: PROMIS versus SMFA in orthopaedic trauma care; Dorsal hook plating of patella fractures: reliable fixation and satisfactory outcomes; The impact of obesity on subtrochanteric femur fracture outcomes; Low-dose NSAIDs (ketorolac) and cytokine modulation in orthopaedic polytrauma: a detailed analysis.


Bone & Joint Research
Vol. 11, Issue 11 | Pages 835 - 842
17 Nov 2022
Wiesli MG Livio F Achermann Y Gautier E Wahl P

Aims

There is a considerable challenge in treating bone infections and orthopaedic device-associated infection (ODAI), partly due to impaired penetration of systemically administrated antibiotics at the site of infection. This may be circumvented by local drug administration. Knowledge of the release kinetics from any carrier material is essential for proper application. Ceftriaxone shows a particular constant release from calcium sulphate (CaSO4) in vitro, and is particularly effective against streptococci and a large portion of Gram-negative bacteria. We present the clinical release kinetics of ceftriaxone-loaded CaSO4 applied locally to treat ODAI.

Methods

A total of 30 operations with ceftriaxone-loaded CaSO4 had been performed in 28 patients. Ceftriaxone was applied as a single local antibiotic in 21 operations and combined with vancomycin in eight operations, and in an additional operation with vancomycin and amphotericin B. Sampling of wound fluid was performed from drains or aspirations. Ceftriaxone concentrations were measured by liquid chromatography with tandem mass spectrometry (LC-MS/MS).


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 7 | Pages 990 - 991
1 Jul 2011
Mirzatolooei F

We report a variant of tibial hemimelia in a six-year-old boy that did not comply with recognised classification systems. The femur and knee were normal, but the fibula was displaced proximally and there was severe diastasis of the proximal and distal tibiofibular joints to the extent that a grossly deformed foot articulated with the fibula and there was separate soft-tissue cover for the distal tibia and fibula. Although it would have been preferable to create a one-bone leg, amputate the foot and use the fibula as the stump for a below-knee prosthesis, local circumstances resulted in the choice of a disarticulation through the knee. This was undertaken without complications, and six months post-operatively the child was walking comfortably with a prosthesis


Bone & Joint Open
Vol. 5, Issue 8 | Pages 671 - 680
14 Aug 2024
Fontalis A Zhao B Putzeys P Mancino F Zhang S Vanspauwen T Glod F Plastow R Mazomenos E Haddad FS

Aims

Precise implant positioning, tailored to individual spinopelvic biomechanics and phenotype, is paramount for stability in total hip arthroplasty (THA). Despite a few studies on instability prediction, there is a notable gap in research utilizing artificial intelligence (AI). The objective of our pilot study was to evaluate the feasibility of developing an AI algorithm tailored to individual spinopelvic mechanics and patient phenotype for predicting impingement.

Methods

This international, multicentre prospective cohort study across two centres encompassed 157 adults undergoing primary robotic arm-assisted THA. Impingement during specific flexion and extension stances was identified using the virtual range of motion (ROM) tool of the robotic software. The primary AI model, the Light Gradient-Boosting Machine (LGBM), used tabular data to predict impingement presence, direction (flexion or extension), and type. A secondary model integrating tabular data with plain anteroposterior pelvis radiographs was evaluated to assess for any potential enhancement in prediction accuracy.


Bone & Joint Open
Vol. 5, Issue 8 | Pages 688 - 696
22 Aug 2024
Hanusrichter Y Gebert C Steinbeck M Dudda M Hardes J Frieler S Jeys LM Wessling M

Aims

Custom-made partial pelvis replacements (PPRs) are increasingly used in the reconstruction of large acetabular defects and have mainly been designed using a triflange approach, requiring extensive soft-tissue dissection. The monoflange design, where primary intramedullary fixation within the ilium combined with a monoflange for rotational stability, was anticipated to overcome this obstacle. The aim of this study was to evaluate the design with regard to functional outcome, complications, and acetabular reconstruction.

Methods

Between 2014 and 2023, 79 patients with a mean follow-up of 33 months (SD 22; 9 to 103) were included. Functional outcome was measured using the Harris Hip Score and EuroQol five-dimension questionnaire (EQ-5D). PPR revisions were defined as an endpoint, and subgroups were analyzed to determine risk factors.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 10 | Pages 1273 - 1279
1 Oct 2007
Giannoudis PV van Griensven M Tsiridis E Pape HC

Technological advances and shorter rescue times have allowed early and effective resuscitation after trauma and brought attention to the host response to injury. Trauma patients are at risk of progressive organ dysfunction from what appears to be an uncontrolled immune response. The availability of improved techniques of molecular diagnosis has allowed investigation of the role of genetic variations in the inflammatory response to post-traumatic complications and particularly to sepsis. This review examines the current evidence for the genetic predisposition to adverse outcome after trauma. While there is evidence supporting the involvement of different polymorphic variants of genes in determining the post-traumatic course and the development of complications, larger-scale studies are needed to improve the understanding of how genetic variability influences the responses to post-traumatic complications and pharmacotherapy


Bone & Joint Research
Vol. 13, Issue 5 | Pages 237 - 246
17 May 2024
Cheng B Wu C Wei W Niu H Wen Y Li C Chen P Chang H Yang Z Zhang F

Aims

To assess the alterations in cell-specific DNA methylation associated with chondroitin sulphate response using peripheral blood collected from Kashin-Beck disease (KBD) patients before initiation of chondroitin sulphate treatment.

Methods

Peripheral blood samples were collected from KBD patients at baseline of chondroitin sulphate treatment. Methylation profiles were generated using reduced representation bisulphite sequencing (RRBS) from peripheral blood. Differentially methylated regions (DMRs) were identified using MethylKit, while DMR-related genes were defined as those annotated to the gene body or 2.2-kilobase upstream regions of DMRs. Selected DMR-related genes were further validated by quantitative reverse transcriptase polymerase chain reaction (qRT-PCR) to assess expression levels. Tensor composition analysis was performed to identify cell-specific differential DNA methylation from bulk tissue.


Bone & Joint Open
Vol. 5, Issue 3 | Pages 210 - 217
13 Mar 2024
Mthethwa PG Marais LC Aldous CM

Aims

The aim of this study is to determine the predictors of overall survival (OS) and predictive factors of poor prognosis of conventional high-grade osteosarcoma of the limbs in a single-centre in South Africa.

Methods

We performed a retrospective cross-sectional analysis to identify the prognostic factors that predict the OS of patients with histologically confirmed high-grade conventional osteosarcoma of the limbs over ten years. We employed the Cox proportional regression model and the Kaplan-Meier method for statistical analysis.


The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 99 - 106
1 Jan 2024
Khal AA Aiba H Righi A Gambarotti M Atherley O'Meally AO Manfrini M Donati DM Errani C

Aims

Low-grade central osteosarcoma (LGCOS), a rare type of osteosarcoma, often has misleading radiological and pathological features that overlap with those of other bone tumours, thereby complicating diagnosis and treatment. We aimed to analyze the clinical, radiological, and pathological features of patients with LGCOS, with a focus on diagnosis, treatment, and outcomes.

Methods

We retrospectively analyzed the medical records of 49 patients with LGCOS (Broder’s grade 1 to 2) treated between January 1985 and December 2017 in a single institute. We examined the presence of malignant features on imaging (periosteal reaction, cortical destruction, soft-tissue invasion), the diagnostic accuracy of biopsy, surgical treatment, and oncological outcome.