Kashigar A Vincent A Gunton MJ Backstein D Safir O Kuzyk PRT

The purpose of this study was to identify factors that predict implant cut-out after cephalomedullary nailing of intertrochanteric and subtrochanteric hip fractures, and to test the significance of calcar referenced tip-apex distance (CalTAD) as a predictor for cut-out.

We retrospectively reviewed 170 consecutive fractures that had undergone cephalomedullary nailing. Of these, 77 met the inclusion criteria of a non-pathological fracture with a minimum of 80 days radiological follow-up (mean 408 days; 81 days to 4.9 years). The overall cut-out rate was 13% (10/77).

The significant parameters in the univariate analysis were tip-apex distance (TAD) (p <  0.001), CalTAD (p = 0.001), cervical angle difference (p = 0.004), and lag screw placement in the anteroposterior (AP) view (Parker’s ratio index) (p = 0.003). Non-significant parameters were age (p = 0.325), gender (p = 1.000), fracture side (p = 0.507), fracture type (AO classification) (p = 0.381), Singh Osteoporosis Index (p = 0.575), lag screw placement in the lateral view (p = 0.123), and reduction quality (modified Baumgaertner’s method) (p = 0.575). In the multivariate analysis, CalTAD was the only significant measurement (p = 0.001). CalTAD had almost perfect inter-observer reliability (interclass correlation coefficient (ICC) 0.901).

Our data provide the first reported clinical evidence that CalTAD is a predictor of cut-out. The finding of CalTAD as the only significant parameter in the multivariate analysis, along with the univariate significance of Parker’s ratio index in the AP view, suggest that inferior placement of the lag screw is preferable to reduce the rate of cut-out.

Cite this article: Bone Joint J 2014; 96-B:1029–34.


Bone & Joint 360
Vol. 2, Issue 4 | Pages 22 - 24
1 Aug 2013

The August 2013 Trauma Roundup360 looks at: reverse oblique fractures do better with a cephalomedullary device; locking screws confer no advantage in tibial plateau fractures; it’s all about the radius of curvature; radius of curvature revisited; radial head replacement in complex elbow reconstruction; stem cells in early fracture haematoma; heterotrophic ossification in forearms; and Boston in perspective.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 1 | Pages 68 - 75
1 Jan 2005
Miedel R Ponzer S Törnkvist H Söderqvist A Tidermark J

We studied 217 patients with an unstable trochanteric or subtrochanteric fracture who had been randomly allocated to treatment by either internal fixation with a standard Gamma nail (SGN) or a Medoff sliding plate (MSP, biaxial dynamisation mode). Their mean age was 84 years (65 to 99) and they were reviewed at four and 12 months after surgery. Assessments of outcome included general complications, technical failures, revision surgery, activities of daily living (ADL), hip function (Charnley score) and the health-related quality of life (HRQOL, EQ-5D).

The rate of technical failure in patients with unstable trochanteric fractures was 6.5% (6/93) (including intra-operative femoral fractures) in the SGN group and 5.2% (5/96) in the MSP group. In patients with subtrochanteric fractures, there were no failures in the SGN group (n = 16) and two in the MSP group (n = 12). In the SGN group, there were intra-operative femoral fractures in 2.8% (3/109) and no post-operative fractures. There was a reduced need for revision surgery in the SGN group compared with the MSP group (8.3%; 9/108; p = 0.072). The SGN group also showed a lower incidence of severe general complications (p < 0.05) and a trend towards a lower incidence of wound infections (p = 0.05). There were no differences between the groups regarding the outcome of ADL, hip function or the HRQOL. The reduction in the HRQOL (EQ-5Dindexscore) was significant in both groups compared with that before the fracture (p < 0.005).

Our findings indicate that the SGN showed good results in both trochanteric and subtrochanteric fractures. The limited number of intra-operative femoral fractures did not influence the outcome or the need for revision surgery. Moreover, the SGN group had a reduced number of serious general complications and wound infections compared with the MSP group. The MSP in the biaxial dynamisation mode had a low rate of failure in trochanteric fractures but an unacceptably high rate when used in the biaxial dynamisation mode in subtrochanteric fractures.

The negative influence of an unstable trochanteric or subtrochanteric fracture on the quality of life was significant regardless of the surgical method.


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 334 - 340
1 Mar 2016
Tayton ER Frampton C Hooper GJ Young SW

Aims

The aim of this study was to identify risk factors for prosthetic joint infection (PJI) following total knee arthroplasty (TKA).

Patients and Methods

The New Zealand Joint Registry database was analysed, using revision surgery for PJI at six and 12 months after surgery as primary outcome measures. Statistical associations between revision for infection, with common and definable surgical and patient factors were tested.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 4 | Pages 556 - 563
1 Apr 2012
Song SH Kim SE Agashe MV Lee H Refai MA Park YE Choi HJ Park JH Song HR

This study evaluated the effect of limb lengthening on longitudinal growth in patients with achondroplasia. Growth of the lower extremity was assessed retrospectively by serial radiographs in 35 skeletally immature patients with achondroplasia who underwent bilateral limb lengthening (Group 1), and in 12 skeletally immature patients with achondroplasia who did not (Group 2). In Group 1, 23 patients underwent only tibial lengthening (Group 1a) and 12 patients underwent tibial and femoral lengthening sequentially (Group 1b).

The mean lengthening in the tibia was 9.2 cm (59.5%) in Group 1a, and 9.0 cm (58.2%) in the tibia and 10.2 cm (54.3%) in the femur in Group 1b. The mean follow-up was 9.3 years (8.6 to 10.3). The final mean total length of lower extremity in Group 1a was 526.6 mm (501.3 to 552.9) at the time of skeletal maturity and 610.1 mm (577.6 to 638.6) in Group 1b, compared with 457.0 mm (411.7 to 502.3) in Group 2. However, the mean actual length, representing the length solely grown from the physis without the length of distraction, showed that there was a significant disturbance of growth after limb lengthening. In Group 1a, a mean decrease of 22.4 mm (21.3 to 23.1) (4.9%) was observed in the actual limb length when compared with Group 2, and a greater mean decrease of 38.9 mm (37.2 to 40.8) (8.5%) was observed in Group 1b when compared with Group 2 at skeletal maturity.

In Group 1, the mean actual limb length was 16.5 mm (15.8 to 17.2) (3.6%) shorter in Group 1b when compared with Group 1a at the time of skeletal maturity. Premature physeal closure was seen mostly in the proximal tibia and the distal femur with relative preservation of proximal femur and distal tibia.

We suggest that significant disturbance of growth can occur after extensive limb lengthening in patients with achondroplasia, and therefore, this should be included in pre-operative counselling of these patients and their parents.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 12 | Pages 1613 - 1617
1 Dec 2006
Karunakar MA Sen A Bosse MJ Sims SH Goulet JA Kellam JF

Our study was designed to compare the effect of indometacin with that of a placebo in reducing the incidence of heterotopic ossification in a prospective, randomised trial. A total of 121 patients with displaced fractures of the acetabulum treated by operation through a Kocher-Langenbeck approach was randomised to receive either indometacin (75 mg) sustained release, or a placebo once daily for six weeks. The extent of heterotopic ossification was evaluated on plain radiographs three months after operation. Significant ossification of Brooker grade III to IV occurred in nine of 59 patients (15.2%) in the indometacin group and 12 of 62 (19.4%) receiving the placebo.

We were unable to demonstrate a statistically significant reduction in the incidence of severe heterotopic ossification with the use of indometacin when compared with a placebo (p = 0.722). Based on these results we cannot recommend the routine use of indometacin for prophylaxis against heterotopic ossification after isolated fractures of the acetabulum.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 367 - 373
1 Mar 2005
Heetveld MJ Raaymakers ELFB van Eck-Smit BL van Walsum ADP Luitse JSK

The results of meta-analysis show a revision rate of 33% for internal fixation of displaced fractures of the femoral neck, mostly because of nonunion. Osteopenia and osteoporosis are highly prevalent in elderly patients. Bone density has been shown to correlate with the intrinsic stability of the fixation of the fracture in cadaver and retrospective studies. We aimed to confirm or refute this finding in a clinical setting.

We performed a prospective, multicentre study of 111 active patients over 60 years of age with a displaced fracture of the femoral neck which was eligible for internal fixation. The bone density of the femoral neck was measured pre-operatively by dual-energy x-ray absorptiometry (DEXA). The patients were divided into two groups namely, those with osteopenia (66%, mean T-score −1.6) and those with osteoporosis (34%, mean T-score −3.0). Age (p = 0.47), gender (p = 0.67), delay to surgery (p = 0.07), the angle of the fracture (p = 0.33) and the type of implant (p = 0.48) were similar in both groups.

Revision to arthroplasty was performed in 41% of osteopenic and 42% of osteoporotic patients (p = 0.87). Morbidity (p = 0.60) and mortality were similar in both groups (p = 0.65). Our findings show that the clinical outcome of internal fixation for displaced fractures of the femoral neck does not depend on bone density and that pre-operative DEXA is not useful.