Advertisement for orthosearch.org.uk
Results 41 - 60 of 220
Results per page:
The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1640 - 1646
1 Dec 2018
Medellin MR Fujiwara T Clark R Jeys LM

Aims. The aim of this study was to describe, analyze, and compare the survival, functional outcome, and complications of minimally invasive (MI) and non-invasive (NI) lengthening total femoral prostheses. Patients and Methods. A total of 24 lengthening total femoral prostheses, 11 MI and 13 NI, were implanted between 1991 and 2016. The characteristics, complications, and functional results were recorded. There were ten female patients and ten male patients. Their mean age at the time of surgery was 11 years (2 to 41). The mean follow-up was 13.2 years (seven months to 29.25 years). A survival analysis was performed, and the failures were classified according to the Modified Henderson System. Results. The overall implant survival was 79% at five, ten, and 20 years for MI prostheses, and 84% at five years and 70% at ten years for NI prostheses. At the final follow-up, 13 prostheses did not require further surgery. The overall complication rate was 46%. The mean revision-free implant survival for MI and NI prostheses was 59 months and 49 months, respectively. There were no statistically significant differences in the overall implant survival, revision-free survival, or the distribution of complications between the two types of prosthesis. Infection rates were also comparable in the groups (9% vs 7%; p = 0.902). The rate of leg-length discrepancy was 54% in MI prostheses and 23% in NI prostheses. In those with a MI prosthesis, there was a smaller mean range of movement of the knee (0° to 62° vs 0° to 83°; p = 0.047), the flexion contracture took a longer mean time to resolve after lengthening (3.3 months vs 1.07 months; p < 0.001) and there was a lower mean Musculoskeletal Tumor Society (MSTS) score (24.7 vs 27; p = 0.295). Conclusion. The survival and complications of MI and NI lengthening total femoral prostheses are comparable. However, patients with NI prosthesis have more accurate correction of leg-length discrepancy, a better range of movement of the knee and an improved overall function


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 170 - 176
1 Feb 2020
Bernthal NM Burke ZDC Hegde V Upfill-Brown A Chen CJ Hwang R Eckardt JJ

Aims. We aimed to examine the long-term mechanical survivorship, describe the modes of all-cause failure, and identify risk factors for mechanical failure of all-polyethylene tibial components in endoprosthetic reconstruction. Methods. This is a retrospective database review of consecutive endoprosthetic reconstructions performed for oncological indications between 1980 and 2019. Patients with all-polyethylene tibial components were isolated and analyzed for revision for mechanical failure. Outcomes included survival of the all-polyethylene tibial component, revision surgery categorized according to the Henderson Failure Mode Classification, and complications and functional outcome, as assessed by the Musculoskeletal Tumor Society (MSTS) score at the final follow-up. Results. A total of 278 patients were identified with 289 all-polyethylene tibial components. Mechanical survival was 98.4%, 91.1%, and 85.2% at five, ten and 15 years, respectively. A total of 15 mechanical failures were identified at the final follow-up. Of the 13 all-polyethylene tibial components used for revision of a previous tibial component, five (38.5%) failed mechanically. Younger patients (< 18 years vs > 18 years; p = 0.005) and those used as revision components (p < 0.001) had significantly increased rates of failure. Multivariate logistic regression modelling showed revision status to be a positive risk factor for failure (odds ratio (OR) 19.498, 95% confidence interval (CI) 4.598 to 82.676) and increasing age was a negative risk factor for failure (OR 0.927, 95% CI 0.872 to 0.987). Age-stratified risk analysis showed that age > 24 years was no longer a statistically significant risk factor for failure. The final mean MSTS score for all patients was 89% (8.5% to 100.0%). Conclusion. The long-term mechanical survivorship of all-polyethylene tibial components when used for tumour endoprostheses was excellent. Tumour surgeons should consider using these components for their durability and the secondary benefits of reduced cost and ease of removal and revision. However, caution should be taken when using all-polyethylene tibial components in the revision setting as a significantly higher rate of mechanical failure was seen in this group of patients. Cite this article: Bone Joint J. 2020;102-B(2):170–176


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 973 - 978
1 Jul 2017
Gupta S Kafchinski LA Gundle KR Saidi K Griffin AM Wunder JS Ferguson PC

Aims. Intercalary allografts following resection of a primary diaphyseal tumour have high rates of complications and failures. At our institution intercalary allografts are augmented with intramedullary cement and fixed using compression plating. Our aim was to evaluate their long-term outcomes. Patients and Methods. A total of 46 patients underwent reconstruction with an intercalary allograft between 1989 and 2014. The patients had a mean age of 32.8 years (14 to 77). The most common diagnoses were osteosarcoma (n = 16) and chondrosarcoma (n = 9). The location of the tumours was in the femur in 21, the tibia in 16 and the humerus in nine. Function was assessed using the Musculoskeletal Tumor Society (MSTS) scoring system and the Toronto Extremity Salvage Score (TESS). The survival of the graft and the overall survival were assessed using the Kaplan-Meier method. Results. The median follow-up was 92 months (4 to 288). The mean MSTS 87 score was 29.1 (19 to 35), the mean MSTS 93 score was 82.2 (50 to 100) and the mean TESS score was 81.2 (43 to 100). Overall survival of the allograft was 84.8%. A total of 15 patients (33%) had a complication. Five allografts were revised for complications and one for local recurrence. Conclusion. Intercalary allografts augmented with intramedullary cement and compression plate fixation provide a reliable and durable method of reconstruction after the excision of a primary diaphyseal bone tumour, with high levels of function and satisfaction. . Cite this article: Bone Joint J 2017;99-B:973–8


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 378 - 386
1 Mar 2018
Campanacci DA Totti F Puccini S Beltrami G Scoccianti G Delcroix L Innocenti M Capanna R

Aims. After intercalary resection of a bone tumour from the femur, reconstruction with a vascularized fibular graft (VFG) and massive allograft is considered a reliable method of treatment. However, little is known about the long-term outcome of this procedure. The aims of this study were to determine whether the morbidity of this procedure was comparable to that of other reconstructive techniques, if it was possible to achieve a satisfactory functional result, and whether biological reconstruction with a VFG and massive allograft could achieve a durable, long-lasting reconstruction. Patients and Methods. A total of 23 patients with a mean age of 16 years (five to 40) who had undergone resection of an intercalary bone tumour of the femur and reconstruction with a VFG and allograft were reviewed clinically and radiologically. The mean follow-up was 141 months (24 to 313). The mean length of the fibular graft was 18 cm (12 to 29). Full weight-bearing without a brace was allowed after a mean of 13 months (seven to 26). Results. At final follow-up, the mean Musculoskeletal Tumor Society Score of 22 evaluable patients was 94% (73 to 100). Eight major complications, five fractures (21.7%), and three nonunions (13%) were seen in seven patients (30.4%). Revision-free survival was 72.3% at five, ten, and 15 years, with fracture and nonunion needing surgery as failure endpoints. Overall survival, with removal of allograft or amputation as failure endpoints, was 94.4% at five, ten, and 15 years. Discussion. There were no complications needing surgical revision after five years had elapsed from surgery, suggesting that the mechanical strength of the implant improves with time, thereby decreasing the risk of complications. In young patients with an intercalary bone tumour of the femur, combining a VFG and massive allograft may result in a reconstruction that lasts a lifetime. Cite this article: Bone Joint J 2018;100-B:378–86


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1094 - 1099
1 Aug 2018
Gupta S Malhotra A Mittal N Garg SK Jindal R Kansay R

Aims. The aims of this study were to establish whether composite fixation (rail-plate) decreases fixator time and related problems in the management of patients with infected nonunion of tibia with a segmental defect, without compromising the anatomical and functional outcomes achieved using the classical Ilizarov technique. We also wished to study the acceptability of this technique using patient-based objective criteria. Patients and Methods. Between January 2012 and January 2015, 14 consecutive patients were treated for an infected nonunion of the tibia with a gap and were included in the study. During stage one, a radical debridement of bone and soft tissue was undertaken with the introduction of an antibiotic-loaded cement spacer. At the second stage, the tibia was stabilized using a long lateral locked plate and a six-pin monorail fixator on its anteromedial surface. A corticotomy was performed at the appropriate level. During the third stage, i.e. at the end of the distraction phase, the transported fragment was aligned and fixed to the plate with two to four screws. An iliac crest autograft was added to the docking site and the fixator was removed. Functional outcome was assessed using the Association for the Study and Application of Methods of Ilizarov (ASAMI) criteria. Patient-reported outcomes were assessed using the Musculoskeletal Tumor Society (MSTS) score. Results. The mean age of patients was 38.1 years (. sd. 12.7). There were 13 men and one woman. The mean size of the defect was 6.4 cm (. sd. 1.3). the mean follow-up was 33.2 months (24 to 50). The mean external fixator index was 21.2 days/cm (. sd. 1.5). The complication rate was 0.5 (7/14) per patient. According to the classification of Paley, there were five problems and two obstacles but no true complications. The ASAMI bone score was excellent in all patients. The functional ASAMI scores were excellent in eight and good in six patients. The mean MSTS composite score was 83.9% (. sd. 7.1), with an MSTS emotional acceptance score of 4.9 (. sd. 0.5; maximum possible 5). Conclusion. Composite fixation (rail-plate) decreases fixator time and the associated complications, in the treatment of patients of infected nonunion tibia with a segmental defect. It also provides good anatomical and functional results with high emotional acceptance. Cite this article: Bone Joint J 2018;100-B:1094–9


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 11 | Pages 1574 - 1579
1 Nov 2010
Hariri A Mascard E Atlan F Germain MA Heming N Dubousset JF Wicart P

We describe a retrospective review of 38 cases of reconstruction following resection of the metaphysiodiaphysis of the lower limb for malignant bone tumours using free vascularised fibular grafts. The mean follow-up was for 7.6 years (0.4 to 18.4). The mean Musculoskeletal Tumor Society score was 27.2 (20 to 30). The score was significantly higher when the graft was carried out in a one-stage procedure after resection of the tumour rather than in two stages. Bony union was achieved in 89% of the cases. The overall mean time to union was 1.7 years (0.2 to 10.3). Free vascularised fibular transfer is a major operation with frequent, but preventable, complications which allows salvage of the limb with satisfactory functional results


Bone & Joint Research
Vol. 5, Issue 6 | Pages 232 - 238
1 Jun 2016
Tanaka A Yoshimura Y Aoki K Kito M Okamoto M Suzuki S Momose T Kato H

Objectives. Our objective was to predict the knee extension strength and post-operative function in quadriceps resection for soft-tissue sarcoma of the thigh. Methods. A total of 18 patients (14 men, four women) underwent total or partial quadriceps resection for soft-tissue sarcoma of the thigh between 2002 and 2014. The number of resected quadriceps was surveyed, knee extension strength was measured with the Biodex isokinetic dynamometer system (affected side/unaffected side) and relationships between these were examined. The Musculoskeletal Tumor Society (MSTS) score, Toronto Extremity Salvage Score (TESS), European Quality of Life-5 Dimensions (EQ-5D) score and the Short Form 8 were used to evaluate post-operative function and examine correlations with extension strength. The cutoff value for extension strength to expect good post-operative function was also calculated using a receiver operating characteristic (ROC) curve and Fisher’s exact test. Results. Extension strength decreased when the number of resected quadriceps increased (p < 0.001), and was associated with lower MSTS score, TESS and EQ-5D (p = 0.004, p = 0.005, p = 0.006, respectively). Based on the functional evaluation scales, the cutoff value of extension strength was 56.2%, the equivalent to muscle strength with resection of up to two muscles. Conclusion. Good post-operative results can be expected if at least two quadriceps muscles are preserved. Cite this article: A. Tanaka, Y. Yoshimura, K. Aoki, M. Kito, M. Okamoto, S. Suzuki, T. Momose, H. Kato. Knee extension strength and post-operative functional prediction in quadriceps resection for soft-tissue sarcoma of the thigh. Bone Joint Res 2016;5:232–238. DOI: 10.1302/2046-3758.56.2000631


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 943 - 947
1 Jul 2007
Wong KC Kumta SM Chiu KH Antonio GE Unwin P Leung KS

The use of a navigation system in musculoskeletal tumour surgery enables the integration of pre-operative CT and MRI images to generate a precise three-dimensional anatomical model of the site and the extent of the tumour. We carried out six consecutive resections of musculoskeletal tumour in five patients using an existing commercial computer navigation system. There were three women and two men with a mean age of 41 years (24 to 47). Reconstruction was performed using a tumour prosthesis in three lesions and a vascularised fibular graft in one. No reconstruction was needed in two cases. The mean follow-up was 6.9 months (3.5 to 10). The mean duration of surgery was 28 minutes (13 to 50). Examination of the resected specimens showed clear margins in all the tumour lesions and a resection that was exactly as planned


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 522 - 528
1 May 2019
Medellin MR Fujiwara T Clark R Stevenson JD Parry M Jeys L

Aims. The aim of this study was to evaluate the prosthesis characteristics and associated conditions that may modify the survival of total femoral endoprosthetic replacements (TFEPR). Patients and Methods. In all, 81 patients treated with TFEPR from 1976 to 2017 were retrospectively evaluated and failures were categorized according to the Henderson classification. There were 38 female patients (47%) and 43 male patients (53%) with a mean age at diagnosis of 43 years (12 to 86). The mean follow-up time was 10.3 years (0 to 31.7). A survival analysis was performed followed by univariate and multivariate Cox regression to identify independent implant survival factors. Results. The revision-free survival of the implant was 71% at five years and 63.3% at ten years. Three prostheses reached 15 years without revision. The mean Musculoskeletal Tumor Society score in the group was 26 (23 to 28). The mechanisms of failure were infection in 18%, structural failures in 6%, tumour progression in 5%, aseptic loosening in 2%, and soft-tissue failures in 1%. Prostheses used for primary reconstruction after oncological resections had lower infection rates than revision implants (8% vs 25%; p = 0.001). The rates of infection in silver-coated and non-silver-coated prosthesis were similar (17.4% vs 19.%; p = 0.869). The incidence of hip dislocation was 10%. Rotating hinge prosthesis had a lower failure rate than fixed hinge prosthesis (5.3% vs 11%). After Cox regression, the independent factors associated with failures were the history of previous operations (hazard ratio (HR) 3.7; p = 0.041), and the associated arthroplasty of the proximal tibia (HR 3.8; p = 0.034). At last follow-up, 11 patients (13%) required amputation. Conclusion. TFEPR offers a reliable reconstruction option for massive bone loss of the femur, with a good survival when the prosthesis is used as a primary implant. The use of a rotating hinge at the knee and dual mobility bearing at the hip may be adequate to reduce the risk of mechanical and soft-tissue failures. Infection remains the main concern and there is insufficient evidence to support the routine use of silver-coated endoprosthesis. Cite this article: Bone Joint J 2019;101-B:522–528


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 7 | Pages 1015 - 1019
1 Sep 2001
van Dam MS Kok GJ Munneke M Vogelaar FJ Vlieland TPMV Taminiau AHM

A continuous ambulatory activity monitor allows objective measurement of the amount and intensity of physical activity. We examined the reliability and validity of this device in the assessment of seven aspects of function over a period of 24 hours in 20 patients who had undergone limb salvage or amputation for a tumour in the leg. The test-retest reliability was determined by undertaking identical assessments on two separate days. The measurements were compared with other indicators of functional status and quality of life in order to determine the validity of the monitor. Its reliability was satisfactory, with intraclass correlation coefficients ranging from 0.65 to 0.91. Significant correlations were seen between the ‘time spent walking’ and the Musculoskeletal Tumor Society rating scales and the Rand-36 physical functioning score. There was also a significant association between the ‘movement intensity during walking’ and the Musculoskeletal Tumor Society score. The satisfactory reliability and validity of the monitor shows considerable promise for its use as a device for measuring physical activity objectively in patients after surgery for limb-salvage or an amputation


The Bone & Joint Journal
Vol. 96-B, Issue 5 | Pages 684 - 690
1 May 2014
Xie L X. D. T Yang RL Guo W

We retrospectively reviewed the outcomes of 33 consecutive patients who had undergone an extra-articular, total or partial scapulectomy for a malignant tumour of the shoulder girdle between 1 July 2001 and 30 September 2013. Of these, 26 had tumours which originated in the scapula or the adjacent soft tissue and underwent a classic Tikhoff–Linberg procedure, while seven with tumours arising from the proximal humerus were treated with a modified Tikhoff-Linberg operation. We used a Ligament Advanced Reinforcement System for soft-tissue reconstruction in nine patients, but not in the other 24. The mean Musculoskeletal Tumor Society score (MSTS) was 17.6 (95% confidence interval (CI) 15.9 to 19.4); 17.6 (95% CI 15.5 to 19.6) after the classic Tikhoff–Linberg procedure and 18.1 (95% CI 13.8 to 22.3) after the modified Tikhoff–Linberg procedure. Patients who had undergone a LARS soft-tissue reconstruction had a mean score of 18.6 (95% (CI) 13.9 to 22.4) compared with 17.2 (95% CI 15.5 to 19.0) for those who did not. The Tikhoff–Linberg procedure is a useful method for wide resection of a malignant tumour of the shoulder girdle which helps to preserve hand and elbow function. The method of soft-tissue reconstruction has no effect on functional outcome. . Cite this article: Bone Joint J 2014;96-B:684–90


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1237 - 1243
1 Sep 2017
Emori M Kaya M Irifune H Takahashi N Shimizu J Mizushima E Murahashi Y Yamashita T

Aims. The aims of this study were to analyse the long-term outcome of vascularised fibular graft (VFG) reconstruction after tumour resection and to evaluate the usefulness of the method. . Patients and Methods. We retrospectively reviewed 49 patients who had undergone resection of a sarcoma and reconstruction using a VFG between 1988 and 2015. Their mean follow-up was 98 months (5 to 317). Reconstruction was with an osteochondral graft (n = 13), intercalary graft (n = 12), inlay graft (n = 4), or resection arthrodesis (n = 20). We analysed the oncological and functional outcome, and the rate of bony union and complications. Results. Five- and ten-year overall survival rates were 89% and 86%, respectively. Local recurrence occurred in two patients. Eight patients developed pulmonary metastases. Bone union was achieved in 44 patients (90%). Fracture occurred in six patients (12%), infection in three (6%), and nonunion in five (10%). The mean Musculoskeletal Tumor Society (MSTS) scores were as follows: osteochondral graft 70%; intercalary graft 73%; inlay graft 89%; and resection arthrodesis 83%. Conclusion. Although associated with a relatively high rate of complications, each reconstruction method is useful, with a high rate of successful limb salvage and a good long-term functional outcome. Cite this article: Bone Joint J 2017;99-B:1237–43


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 786 - 794
1 Jun 2008
Aksnes LH Bauer HCF Jebsen NL Foller̊s G Allert C Haugen GS Hall KS

We evaluated the long-term functional outcome in 118 patients treated for osteosarcoma or Ewing’s sarcoma in the extremities a minimum of five years after treatment. We also examined if impaired function influenced their quality of life and ability to work. The function was evaluated according to the Musculoskeletal Tumor Society (MSTS) score and the Toronto Extremity Salvage Score (TESS). Quality of life was assessed by using the Short Form-36 (SF-36). The mean age at follow-up was 31 years (15 to 57) and the mean follow-up was for 13 years (6 to 22). A total of 67 patients (57%) initially had limb-sparing surgery, but four had a secondary amputation. The median MSTS score was 70% (17% to 100%) and the median TESS was 89% (43% to 100%). The amputees had a significantly lower MSTS score than those with limb-sparing surgery (p < 0.001), but there was no difference for the TESS. Tumour localisation above knee level resulted in significantly lower MSTS scores and TESS (p = 0.003 and p = 0.02, respectively). There were no significant differences in quality of life between amputees and those with limb-sparing surgery except in physical functioning. Of the patients 11% (13) did not work or study. In multivariate analysis, amputation, tumour location above the knee and having muscular pain were associated with low physical function. We conclude that most of the bone tumour survivors managed well after adjustment to their physical limitations. A total of 105 are able to work and have an overall good quality of life


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1063 - 1069
1 Aug 2015
Pilge H Holzapfel BM Rechl H Prodinger PM Lampe R Saur U Eisenhart-Rothe R Gollwitzer H

The aim of this study was to analyse the gait pattern, muscle force and functional outcome of patients who had undergone replacement of the proximal tibia for tumour and alloplastic reconstruction of the extensor mechanism using the patellar-loop technique. Between February 1998 and December 2009, we carried out wide local excision of a primary sarcoma of the proximal tibia, proximal tibial replacement and reconstruction of the extensor mechanism using the patellar-loop technique in 18 patients. Of these, nine were available for evaluation after a mean of 11.6 years (0.5 to 21.6). The strength of the knee extensors was measured using an Isobex machine and gait analysis was undertaken in our gait assessment laboratory. Functional outcome was assessed using the American Knee Society (AKS) and Musculoskeletal Tumor Society (MSTS) scores. The gait pattern of the patients differed in ground contact time, flexion heel strike, maximal flexion loading response and total sagittal plane excursion. The mean maximum active flexion was 91° (30° to 110°). The overall mean extensor lag was 1° (0° to 5°). The mean extensor muscle strength was 25.8% (8.3% to 90.3%) of that in the non-operated leg (p < 0.001). The mean functional scores were 68.7% (43.4% to 83.3%) (MSTS) and 71.1 (30 to 90) (AKS functional score). In summary, the results show that reconstruction of the extensor mechanism using this technique gives good biomechanical and functional results. The patients’ gait pattern is close to normal, except for a somewhat stiff knee gait pattern. The strength of the extensor mechanism is reduced, but sufficient for walking. . Cite this article: Bone Joint J 2015;97-B:1063–9


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1487 - 1491
1 Nov 2006
Ahlmann ER Menendez LR

Custom-made intercalary endoprostheses may be used for the reconstruction of diaphyseal defects following the resection of bone tumours. The aim of this study was to determine the survival of intercalary endoprostheses with a lap joint design, and to evaluate the clinical results, complications and functional outcome. We retrospectively reviewed six consecutive patients, three of whom underwent limb salvage with intercalary endoprostheses of the tibia, two of the femur, and one of the humerus. Their mean age was 42 years (28 to 64). The mean follow-up was 21.6 months (9 to 58). The humeral prosthesis required revision at 14 months owing to aseptic loosening. There were no implant-related failures. Musculoskeletal Tumour Society functional outcome scores indicated that patients achieved 90% of premorbid function. Custom intercalary endoprostheses result in reconstructions comparable with, if not better than, those of allografts. Using this design of implant reduces the incidence of early complications and difficulties experienced with previous versions


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 875 - 879
1 Jun 2010
Puri A Gulia A Agarwal MG Reddy K

Between June 2005 and March 2008, 14 patients with a Campanacci grade-3 giant-cell tumour of the distal radius were treated by en bloc resection and reconstruction by ulnar translocation with arthrodesis of the wrist. The mean length of radius resected was 7.9 cm (5.5 to 15). All the patients were followed to bony union and 12 were available at a mean follow-up of 26 months (10 to 49). The mean time to union was four months (3 to 7) at the ulnocarpal junction and five months (3 to 8) at the ulnoradial junction. All except one patient had an excellent range of pronation and supination. The remaining patient developed a radio-ulnar synostosis. The mean Musculoskeletal Tumor Society score was 26 (87%, range 20 to 28). Three patients had a soft-tissue recurrence, but with no bony involvement. They underwent a further excision and are currently well and free from disease. Ulnar translocation provides a local vascularised bone graft to reconstruct the defect left after excision of the distal radius for giant cell tumour. It avoids the need for a microvascular procedure while retaining rotation of the forearm and good function of the hand


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1366 - 1372
1 Oct 2009
Abed YY Beltrami G Campanacci DA Innocenti M Scoccianti G Capanna R

We reviewed 25 patients who had undergone resection of a primary bone sarcoma which extended to within 5 cm of the knee with reconstruction by a combination of a free vascularised fibular graft and a massive allograft bone shell. The distal femur was affected in four patients and the proximal tibia in 21. Their mean age at the time of operation was 19.7 years (5 to 52) and the mean follow-up period 140 months (28 to 213). Three vascularised transfers failed. The mean time to union of the fibula was 5.6 months (3 to 10) and of the allograft 19.6 months (10 to 34). Full weight-bearing was allowed at a mean of 21.4 months (14 to 36). The mean functional score at final follow-up was 27.4 (18 to 30) using a modfied 30-point Musculoskeletal Tumour Society rating system. The overall limb-salvage rate was 88%. The results of our study suggest that the combined use of a vascularised fibular graft and allograft is of value as a limb-salvage procedure for intercalary reconstruction after resection of bone tumours around the knee, especially in skeletally immature patients


The Bone & Joint Journal
Vol. 99-B, Issue 3 | Pages 401 - 408
1 Mar 2017
Kang S Lee JS Park J Park S

Aims. Children treated for osteosarcoma around the knee often have a substantial leg-length discrepancy at skeletal maturity. The aim of this study was to investigate the results of staged skeletal reconstruction after a leg lengthening procedure using an external fixator in these patients. Patients and Methods. We reviewed 11 patients who underwent staged reconstruction with either an arthroplasty (n = 6) or an arthrodesis (n = 5). A control group of 11 patients who had undergone wide excision and concurrent reconstruction with an arthroplasty were matched for gender, location, and size of tumour. We investigated the change in leg-length discrepancy, function as assessed by the Musculoskeletal Tumor Society Scale (MSTS) score and complications. Results. A mean 5.2 cm (1.7 to 8.9) of lengthening was achieved. The mean MSTS scores significantly improved after staged reconstruction (p = 0.003) but were still worse than those of the control group (p = 0.049). However, the MSTS scores of the arthroplasty subgroup were comparable with those of the controls, although the extensor lag was greater and the range of movement was less. The patient group experienced more complications, but all of these resolved. Conclusion. Approximately 5 cm of lengthening and significant functional improvement can be achieved by staged reconstruction and lengthening, without major complications. Although it has limitations, this method of treatment seems to be a satisfactory surgical option for growing children with a significant leg-length discrepancy after excision of an osteosarcoma around the knee. Cite this article: Bone Joint J 2017;99-B:401–8


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1498 - 1503
1 Nov 2007
Hanna SA David LA Aston WJS Gikas PD Blunn GW Cannon SR Briggs TWR

Between 1988 and 2006, 18 patients had a custom-made endoprosthetic replacement of the distal humerus for bone tumours at our institution. There were 11 primary malignant neoplasms, six secondary deposits, and one benign aggressive tumour. The mean follow-up was for 4.4 years (1 to 18.2). Complications occurred in nine patients and included aseptic loosening in three (16.6%), local recurrence in two (11%), infection in two (11%), neuropraxia of the radial nerve in one (5.5%) and a peri-prosthetic fracture in one (5.5%). Excision was inadequate in four patients (22%), all of which developed local recurrence and/or metastases. There were seven deaths from the primary disease after a mean of 2.3 years (1 to 5), one of whom had an above-elbow amputation for local recurrence seven months before death. The remaining six had satisfactory elbow function at their last follow-up. The 11 living patients were evaluated using the Musculoskeletal Tumour Society and Toronto Extremity Salvage scoring systems. The mean scores achieved were 76% (67% to 87%) and 73% (59% to 79%), respectively. Overall, 17 of 18 patients had significant improvement in the degree of their pain following operation. Custom-made endoprosthetic reconstruction of the elbow for bone tumours is a viable treatment in carefully selected patients. It maintains satisfactory function and provides good pain relief


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 258 - 264
1 Feb 2015
Young PS Bell SW Mahendra A

We report our experience of using a computer navigation system to aid resection of malignant musculoskeletal tumours of the pelvis and limbs and, where appropriate, their subsequent reconstruction. We also highlight circumstances in which navigation should be used with caution. We resected a musculoskeletal tumour from 18 patients (15 male, three female, mean age of 30 years (13 to 75) using commercially available computer navigation software (Orthomap 3D) and assessed its impact on the accuracy of our surgery. Of nine pelvic tumours, three had a biological reconstruction with extracorporeal irradiation, four underwent endoprosthetic replacement (EPR) and two required no bony reconstruction. There were eight tumours of the bones of the limbs. Four diaphyseal tumours underwent biological reconstruction. Two patients with a sarcoma of the proximal femur and two with a sarcoma of the proximal humerus underwent extra-articular resection and, where appropriate, EPR. One soft-tissue sarcoma of the adductor compartment which involved the femur was resected and reconstructed using an EPR. Computer navigation was used to aid reconstruction in eight patients. Histological examination of the resected specimens revealed tumour-free margins in all patients. Post-operative radiographs and CT showed that the resection and reconstruction had been carried out as planned in all patients where navigation was used. In two patients, computer navigation had to be abandoned and the operation was completed under CT and radiological control. The use of computer navigation in musculoskeletal oncology allows accurate identification of the local anatomy and can define the extent of the tumour and proposed resection margins. Furthermore, it helps in reconstruction of limb length, rotation and overall alignment after resection of an appendicular tumour. . Cite this article: Bone Joint J 2015;97-B:258–64