Advertisement for orthosearch.org.uk
Results 41 - 60 of 267
Results per page:
The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 486 - 491
1 Apr 2014
Jämsen E Puolakka T Peltola M Eskelinen A Lehto MUK

We evaluated the duration of hospitalisation, occurrence of infections, hip dislocations, revisions, and mortality following primary hip and knee replacement in 857 patients with Parkinson’s disease and compared them with 2571 matched control patients. The data were collected from comprehensive nationwide Finnish health registers. The mean follow-up was six years (1 to 13). The patients with Parkinson’s disease had a longer mean length of stay (21 days [1 to 365] vs 13 [1 to 365] days) and an increased risk for hip dislocation during the first post-operative year (hazard ratio (HR) 2.33, 95% confidence intervals (CI) 1.02 to 5.32). There was no difference in infection and revision rates, and one-year mortality. In longer follow-up, patients with Parkinson’s disease had higher mortality (HR 1.94, 95% CI 1.68 to 2.25) and only 274 (34.7%) were surviving ten years after surgery. In patients with Parkinson’s disease, cardiovascular and psychiatric comorbidity were associated with prolonged hospitalisation and cardiovascular diseases also with increased mortality. Cite this article: Bone Joint J 2014;96-B:486–91


Bone & Joint Open
Vol. 2, Issue 11 | Pages 940 - 944
18 Nov 2021
Jabbal M Campbel N Savaridas T Raza A

Aims. Elective orthopaedic surgery was cancelled early in the COVID-19 pandemic and is currently running at significantly reduced capacity in most institutions. This has resulted in a significant backlog to treatment, with some hospitals projecting that waiting times for arthroplasty is three times the pre-COVID-19 duration. There is concern that the patient group requiring arthroplasty are often older and have more medical comorbidities—the same group of patients advised they are at higher risk of mortality from catching COVID-19. The aim of this study is to investigate the morbidity and mortality in elective patients operated on during the COVID-19 pandemic and compare this to a pre-pandemic cohort. Primary outcome was 30-day mortality. Secondary outcomes were perioperative complications, including nosocomial COVID-19 infection. These operations were performed in a district general hospital, with COVID-19 acute admissions in the same building. Methods. Our institution reinstated elective operations using a “Blue stream” pathway, which involves isolation before and after surgery, COVID-19 testing pre-admission, and separation of ward and theatre pathways for “blue” patients. A register of all arthroplasties was taken, and their clinical course and investigations recorded. Results. During a seven-month period, 340 elective arthroplasties were performed. There was zero mortality. One patient had a positive swab for COVID-19 while an inpatient, but remained asymptomatic. There were two readmissions within a 12-week period for hip dislocation. Patients had a mean age of 68 years (28 to 90), mean BMI of 30 kg/m. 2. (19.0 to 45.6), and mean American Society of Anesthesiologists grade of 2 (1 to 3). Conclusion. Results show no increased morbidity or mortality in this cohort of patients compared to the same hospital’s morbidity and mortality pre-COVID-19. The screened pathway for elective patients is effective in ensuring that patients can be safely operated on electively in an acute hospital. This study should reassure clinicians and patients that arthroplasties can be carried out safely when the appropriate precautions are in place. Cite this article: Bone Jt Open 2021;2(11):940–944


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 522 - 528
1 May 2019
Medellin MR Fujiwara T Clark R Stevenson JD Parry M Jeys L

Aims. The aim of this study was to evaluate the prosthesis characteristics and associated conditions that may modify the survival of total femoral endoprosthetic replacements (TFEPR). Patients and Methods. In all, 81 patients treated with TFEPR from 1976 to 2017 were retrospectively evaluated and failures were categorized according to the Henderson classification. There were 38 female patients (47%) and 43 male patients (53%) with a mean age at diagnosis of 43 years (12 to 86). The mean follow-up time was 10.3 years (0 to 31.7). A survival analysis was performed followed by univariate and multivariate Cox regression to identify independent implant survival factors. Results. The revision-free survival of the implant was 71% at five years and 63.3% at ten years. Three prostheses reached 15 years without revision. The mean Musculoskeletal Tumor Society score in the group was 26 (23 to 28). The mechanisms of failure were infection in 18%, structural failures in 6%, tumour progression in 5%, aseptic loosening in 2%, and soft-tissue failures in 1%. Prostheses used for primary reconstruction after oncological resections had lower infection rates than revision implants (8% vs 25%; p = 0.001). The rates of infection in silver-coated and non-silver-coated prosthesis were similar (17.4% vs 19.%; p = 0.869). The incidence of hip dislocation was 10%. Rotating hinge prosthesis had a lower failure rate than fixed hinge prosthesis (5.3% vs 11%). After Cox regression, the independent factors associated with failures were the history of previous operations (hazard ratio (HR) 3.7; p = 0.041), and the associated arthroplasty of the proximal tibia (HR 3.8; p = 0.034). At last follow-up, 11 patients (13%) required amputation. Conclusion. TFEPR offers a reliable reconstruction option for massive bone loss of the femur, with a good survival when the prosthesis is used as a primary implant. The use of a rotating hinge at the knee and dual mobility bearing at the hip may be adequate to reduce the risk of mechanical and soft-tissue failures. Infection remains the main concern and there is insufficient evidence to support the routine use of silver-coated endoprosthesis. Cite this article: Bone Joint J 2019;101-B:522–528


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 702 - 704
1 May 2017
Haddad FS

Haefeli PC, Marecek GS, Keel MJB, Siebenrock KA, Tannast M. Patients undergoing surgical hip dislocation for the treatment of acetabular fractures show favourable long-term outcome. Bone Joint J;2017;99-B:508-515


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1250 - 1255
1 Sep 2017
Talbot C Adam J Paton R

Aims. Despite the presence of screening programmes, infants continue to present with late developmental dysplasia of the hip (DDH), the impact of which is significant. The aim of this study was to assess infants with late presenting dislocation of the hip despite universal clinical neonatal and selective ultrasound screening. Patients and Methods. Between 01 January 1997 to 31 December 2011, a prospective, longitudinal study was undertaken of a cohort of 64 670 live births. Late presenting dislocation was defined as presentation after three months of age. Diagnosis was confirmed by ultrasound and plain radiography. Patient demographics, referral type, reason for referral, risk factors (breech presentation/strong family history) and clinical and radiological findings were recorded. Results. There were 31 infants with an irreducible dislocation of the hip, an incidence of 0.48 (95% confidence interval (CI) 0.34 to 0.68) per 1000 live births. Of these, 18 (0.28 (95% CI 0.17 to 0.44) per 1000 live births; 58%) presented late. All infants had a documented normal newborn clinical examination and no abnormality reported in the six to eight week check. Of the 18 late presenting cases 72% (n = 13) had no risk factors: 16 were referred by GPs and two were late due to administrative issues (missed appointments). The mean time to diagnosis was 62.4 weeks (19 to 84). Conclusion. Despite universal clinical neonatal and selective ultrasound screening, late cases of irreducible hip dislocation still occur. We recommend an update of the national screening programme for DDH, a review of training and education of healthcare professionals involved in the physical examination of neonates and infants, and the addition of a further assessment after the six to eight week check. Cite this article: Bone Joint J 2017;99-B:1250–5


Aims

The purpose of this study was to assess the reliability and responsiveness to hip surgery of a four-point modified Care and Comfort Hypertonicity Questionnaire (mCCHQ) scoring tool in children with cerebral palsy (CP) in Gross Motor Function Classification System (GMFCS) levels IV and V.

Methods

This was a population-based cohort study in children with CP from a national surveillance programme. Reliability was assessed from 20 caregivers who completed the mCCHQ questionnaire on two occasions three weeks apart. Test-retest reliability of the mCCHQ was calculated, and responsiveness before and after surgery for a displaced hip was evaluated in a cohort of children.


Bone & Joint 360
Vol. 4, Issue 1 | Pages 29 - 31
1 Feb 2015

The February 2015 Children’s orthopaedics Roundup. 360 . looks at: Hip dislocation in children with CTEV: two decades of experience; Population-based prevention of DDH in cerebral palsy: 20 years’ experience; Shoulder derotation in congenital plexus palsy; Back pain in the paediatric population: could MRI be the answer?; Intercondylar fracture of the humerus in children; The Dunn osteotomy in SUFE; Radiocapitellar line a myth!; Do ‘flatfooted’ children suffer?


Bone & Joint Open
Vol. 4, Issue 11 | Pages 825 - 831
1 Nov 2023
Joseph PJS Khattak M Masudi ST Minta L Perry DC

Aims

Hip disease is common in children with cerebral palsy (CP) and can decrease quality of life and function. Surveillance programmes exist to improve outcomes by treating hip disease at an early stage using radiological surveillance. However, studies and surveillance programmes report different radiological outcomes, making it difficult to compare. We aimed to identify the most important radiological measurements and develop a core measurement set (CMS) for clinical practice, research, and surveillance programmes.

Methods

A systematic review identified a list of measurements previously used in studies reporting radiological hip outcomes in children with CP. These measurements informed a two-round Delphi study, conducted among orthopaedic surgeons and specialist physiotherapists. Participants rated each measurement on a nine-point Likert scale (‘not important’ to ‘critically important’). A consensus meeting was held to finalize the CMS.


The Bone & Joint Journal
Vol. 98-B, Issue 9 | Pages 1283 - 1288
1 Sep 2016
Abdelazeem AH Beder FK Abdel Karim MM Abdelazeem H Abdel-Ghani H

Aims. This study analysed the clinical and radiological outcome of anatomical reduction of a moderate or severe stable slipped capital femoral epiphysis (SCFE) treated by subcapital osteotomy (a modified Dunn osteotomy) through the surgical approach described by Ganz. . Patients and Methods. We prospectively studied 31 patients (32 hips; 16 females and five males; mean age 14.3 years) with SCFE. On the Southwick classification, ten were of moderate severity (head-shaft angle > 30° to 60°) and 22 were severe (head-shaft angle > 60°). Each underwent open reduction and internal fixation using an intracapsular osteotomy through the physeal growth plate after safe surgical hip dislocation. Unlike the conventional procedure, 25 hips did not need an osteotomy of the apophysis of the great trochanter and were managed using an extended retinacular posterior flap. . Results. Clinical outcome was assessed using the range of movement and the Harris Hip (HHS), Western Ontario and McMaster Universities Osteoarthritis (WOMAC), and Merle d’Aubigné scores, while radiological measurements included slip and alpha angles. The mean duration of follow-up was 24.1 months (12 to 40). . There was a significant improvement in all clinical and radiological measurements after treatment (p < 0.001). Post-operative major complications were one deep infection and one case of femoral head collapse. . Conclusion. These findings suggest that a modified Dunn osteotomy carried out through Ganz approach is a safe and effective method of treating the stable SCFE with a high degree of slip. . Cite this article: Bone Joint J 2016;98-B:1283–8


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1434 - 1441
1 Nov 2018
Blakeney WG Beaulieu Y Puliero B Lavigne M Roy A Massé V Vendittoli P

Aims. This study reports the mid-term results of total hip arthroplasty (THA) performed using a monoblock acetabular component with a large-diameter head (LDH) ceramic-on-ceramic (CoC) bearing. Patients and Methods. Of the 276 hips (246 patients) included in this study, 264 (96%) were reviewed at a mean of 67 months (48 to 79) postoperatively. Procedures were performed with a mini posterior approach. Clinical and radiological outcomes were recorded at regular intervals. A noise assessment questionnaire was completed at last follow-up. Results. There were four re-operations (1%) including one early revision for insufficient primary fixation (0.4%). No hip dislocation was reported. The mean University of California, Los Angeles (UCLA) activity score, 12-Item Short-Form Health Survey (SF-12) Mental Component Summary (MCS) score, SF-12 Physical Component Summary (PCS) score, Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score, and Forgotten Joint Score (FJS) were 6.6 (2 to 10), 52.8 (25.5 to 65.7), 53.0 (27.2 to 66.5), 7.7 (0 to 63), and 88.5 (23 to 100), respectively. No signs of loosening or osteolysis were observed on radiological review. The incidence of squeaking was 23% (n = 51/225). Squeaking was significantly associated with larger head diameter (p < 0.001), younger age (p < 0.001), higher SF-12 PCS (p < 0.001), and UCLA scores (p < 0.001). Squeaking did not affect patient satisfaction, with 100% of the squeaking hips satisfied with the surgery. Conclusion. LDH CoC THAs have demonstrated excellent functional outcomes at medium-term follow-up, with very low revision rate and no dislocations. The high incidence of squeaking did not affect patient satisfaction or function. LDH CoC with a monoblock acetabular component has the potential to provide long term implant survivorship with unrestricted activity, while avoiding implant impingement, liner fracture at insertion, and hip instability. Cite this article: Bone Joint J 2018;100-B:1434–41


Bone & Joint 360
Vol. 12, Issue 4 | Pages 13 - 16
1 Aug 2023

The August 2023 Hip & Pelvis Roundup360 looks at: Using machine learning to predict venous thromboembolism and major bleeding events following total joint arthroplasty; Antibiotic length in revision total hip arthroplasty; Preoperative colonization and worse outcomes; Short stem cemented total hip arthroplasty; What are the outcomes of one- versus two-stage revisions in the UK?; To cement or not to cement? The best approach in hemiarthroplasty; Similar re-revisions in cemented and cementless femoral revisions for periprosthetic femoral fractures in total hip arthroplasty; Are hip precautions still needed?


Bone & Joint Open
Vol. 4, Issue 7 | Pages 523 - 531
11 Jul 2023
Passaplan C Hanauer M Gautier L Stetzelberger VM Schwab JM Tannast M Gautier E

Aims

Hyaline cartilage has a low capacity for regeneration. Untreated osteochondral lesions of the femoral head can lead to progressive and symptomatic osteoarthritis of the hip. The purpose of this study is to analyze the clinical and radiological long-term outcome of patients treated with osteochondral autograft transfer. To our knowledge, this study represents a series of osteochondral autograft transfer of the hip with the longest follow-up.

Methods

We retrospectively evaluated 11 hips in 11 patients who underwent osteochondral autograft transfer in our institution between 1996 and 2012. The mean age at the time of surgery was 28.6 years (8 to 45). Outcome measurement included standardized scores and conventional radiographs. Kaplan-Meier survival curve was used to determine the failure of the procedures, with conversion to total hip arthroplasty (THA) defined as the endpoint.


Bone & Joint 360
Vol. 13, Issue 4 | Pages 37 - 40
2 Aug 2024

The August 2024 Children’s orthopaedics Roundup360 looks at: Antibiotic prophylaxis and infection rates in paediatric supracondylar humerus fractures; Clinical consensus recommendations for the non-surgical treatment of children with Perthes’ disease in the UK; Health-related quality of life in idiopathic toe walkers: a multicentre prospective cross-sectional study; Children with spinal dysraphism: a systematic review of reported outcomes; No delay in age of crawling, standing, or walking with Pavlik harness treatment: a prospective cohort study; No value found with routine early postoperative radiographs after implant removal in paediatric patients; What do we know about the natural history of spastic hip dysplasia and pain in total-involvement cerebral palsy?; Evaluating the efficacy and safety of preoperative gallows traction for hip open reduction in infants


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1327 - 1332
1 Dec 2023
Morris WZ Kak A Mayfield LM Kang MS Jo C Kim HKW

Aims

Abduction bracing is commonly used to treat developmental dysplasia of the hip (DDH) following closed reduction and spica casting, with little evidence to support or refute this practice. The purpose of this study was to determine the efficacy of abduction bracing after closed reduction in improving acetabular index (AI) and reducing secondary surgery for residual hip dysplasia.

Methods

We performed a retrospective review of patients treated with closed reduction for DDH at a single tertiary referral centre. Demographic data were obtained including severity of dislocation based on the International Hip Dysplasia Institute (IHDI) classification, age at reduction, and casting duration. Patients were prescribed no abduction bracing, part-time, or full-time wear post-reduction and casting. AI measurements were obtained immediately upon cast removal and from two- and four-year follow-up radiographs.


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 59 - 65
1 May 2024
Liu WKT Cheung A Fu H Chan PK Chiu KY

Aims

Isolated acetabular liner exchange with a highly crosslinked polyethylene (HXLPE) component is an option to address polyethylene wear and osteolysis following total hip arthroplasty (THA) in the presence of a well-fixed acetabular shell. The liner can be fixed either with the original locking mechanism or by being cemented within the acetabular component. Whether the method used for fixation of the HXLPE liner has any bearing on the long-term outcomes is still unclear.

Methods

Data were retrieved for all patients who underwent isolated acetabular component liner exchange surgery with a HXLPE component in our institute between August 2000 and January 2015. Patients were classified according to the fixation method used (original locking mechanism (n = 36) or cemented (n = 50)). Survival and revision rates were compared. A total of 86 revisions were performed and the mean duration of follow-up was 13 years.


The Journal of Bone & Joint Surgery British Volume
Vol. 54-B, Issue 1 | Pages 40 - 49
1 Feb 1972
Wilkinson JA

1. There is an increasing prevalence in the evidence of prenatal extended knee postures in the legs of newborn, from normal births to breech deliveries and to babies with hip displacements. The extended knee postures are also commoner in female births. 2. Babies with reducible hip displacements appear to be born more often in summer as the result of winter conceptions. Spontaneous recovery is very high, with or without splintage. 3. Irreducible hip displacement does not respond to splintage during the first six months of life. Even with adductor tenotomy, there is a great risk of acetabular and femoral epiphysial damage. This is thought to be due to incarceration of the limbus, present at birth


The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1533 - 1536
1 Nov 2017
Nie K Rymaruk S Paton RW

Aims. A clicky hip is a common referral for clinical and sonographic screening for developmental dysplasia of the hip (DDH). There is controversy regarding whether it represents a true risk factor for pathological DDH. Therefore a 20-year prospective, longitudinal, observational study was undertaken to assess the relationship between the presence of a neonatal clicky hip and pathological DDH. Patients and Methods. A total of 362 infants from 1997 to 2016 were referred with clicky hips to our ‘one-stop’ paediatric hip screening clinic. Hips were assessed clinically for instability and by ultrasound imaging using a simplified Graf/Harcke classification. Dislocated or dislocatable hips were classified as Graf Type IV hips. Results. The mean age at presentation was 13.8 weeks (12.8 to 14.7). In all 351 out of 362 children (97.0%) had Graf Type I hips (normal) that required no treatment. Nine children (2.5%) had Graf Type II hips but all resolved to Graf Type I hips on follow-up scans. One child (0.3%) had Graf Type III hip dysplasia and one child (0.3%) had an irreducible hip dislocation. The two pathological hips were associated with unilateral limited hip abduction. Mean referrals increased from 12.9 to 23.3 each year (p = 0.002) from the first decade of the study to the second, driven by increasing primary care referrals (5.5 versus 16.7 per year, p < 0.001). Conclusion. Most clicky hips required no treatment other than reassurance to parents. Clicky hips with a normal hip examination should be considered a variant of normal childhood and not a risk factor for DDH. However, an abnormal hip examination including unilateral limited hip abduction should prompt urgent further investigations. Cite this article: Bone Joint J 2017;99-B:1533–6


The Bone & Joint Journal
Vol. 104-B, Issue 12 | Pages 1292 - 1303
1 Dec 2022
Polisetty TS Jain S Pang M Karnuta JM Vigdorchik JM Nawabi DH Wyles CC Ramkumar PN

Literature surrounding artificial intelligence (AI)-related applications for hip and knee arthroplasty has proliferated. However, meaningful advances that fundamentally transform the practice and delivery of joint arthroplasty are yet to be realized, despite the broad range of applications as we continue to search for meaningful and appropriate use of AI. AI literature in hip and knee arthroplasty between 2018 and 2021 regarding image-based analyses, value-based care, remote patient monitoring, and augmented reality was reviewed. Concerns surrounding meaningful use and appropriate methodological approaches of AI in joint arthroplasty research are summarized. Of the 233 AI-related orthopaedics articles published, 178 (76%) constituted original research, while the rest consisted of editorials or reviews. A total of 52% of original AI-related research concerns hip and knee arthroplasty (n = 92), and a narrative review is described. Three studies were externally validated. Pitfalls surrounding present-day research include conflating vernacular (“AI/machine learning”), repackaging limited registry data, prematurely releasing internally validated prediction models, appraising model architecture instead of inputted data, withholding code, and evaluating studies using antiquated regression-based guidelines. While AI has been applied to a variety of hip and knee arthroplasty applications with limited clinical impact, the future remains promising if the question is meaningful, the methodology is rigorous and transparent, the data are rich, and the model is externally validated. Simple checkpoints for meaningful AI adoption include ensuring applications focus on: administrative support over clinical evaluation and management; necessity of the advanced model; and the novelty of the question being answered.

Cite this article: Bone Joint J 2022;104-B(12):1292–1303.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 67 - 69
1 Nov 2013
Brooks PJ

Dislocation is one of the most common causes of patient and surgeon dissatisfaction following hip replacement and to treat it, the causes must first be understood. Patient factors include age greater than 70 years, medical comorbidities, female gender, ligamentous laxity, revision surgery, issues with the abductors, and patient education. Surgeon factors include the annual quantity of procedures and experience, the surgical approach, adequate restoration of femoral offset and leg length, component position, and soft-tissue or bony impingement. Implant factors include the design of the head and neck region, and so-called skirts on longer neck lengths. There should be offset choices available in order to restore soft-tissue tension. Lipped liners aid in gaining stability, yet if improperly placed may result in impingement and dislocation. Late dislocation may result from polyethylene wear, soft-tissue destruction, trochanteric or abductor disruption and weakness, or infection. Understanding the causes of hip dislocation facilitates prevention in a majority of instances. Proper pre-operative planning includes the identification of patients with a high offset in whom inadequate restoration of offset will reduce soft-tissue tension and abductor efficiency. Component position must be accurate to achieve stability without impingement. Finally, patient education cannot be over-emphasised, as most dislocations occur early, and are preventable with proper instructions. Cite this article: Bone Joint J 2013;95-B, Supple A:67–9


Bone & Joint Open
Vol. 4, Issue 6 | Pages 408 - 415
1 Jun 2023
Ramkumar PN Shaikh HJF Woo JJ Haeberle HS Pang M Brooks PJ

Aims

The aims of the study were to report for a cohort aged younger than 40 years: 1) indications for HRA; 2) patient-reported outcomes in terms of the modified Harris Hip Score (HHS); 3) dislocation rate; and 4) revision rate.

Methods

This retrospective analysis identified 267 hips from 224 patients who underwent an hip resurfacing arthroplasty (HRA) from a single fellowship-trained surgeon using the direct lateral approach between 2007 and 2019. Inclusion criteria was minimum two-year follow-up, and age younger than 40 years. Patients were followed using a prospectively maintained institutional database.