Advertisement for orthosearch.org.uk
Results 41 - 60 of 395
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 782 - 787
1 Jun 2011
Sun X Easwar TR Manesh S Ryu J Song S Kim S Song H

We compared the complications and outcome of tibial lengthening using the Ilizarov method with and without the use of a supplementary intramedullary nail. In a retrospective case-matched series assembled from 176 patients with tibial lengthening, we matched 52 patients (26 pairs, group A with nail and group B without) according to the following criteria in order of importance: 1) difference in amount of lengthening (± 2 cm); 2) percentage difference in lengthening (± 5%); 3) difference in patient’s age (± seven years); 4) aetiology of the shortening, and 5) level of difficulty in obtaining the correction. The outcome was evaluated using the external fixator index, the healing index and an outcome score according to the criteria of Paley. It was found that some complications were specific to group A or B respectively, but others were common to both groups. The outcome was generally better in lengthenings with a nail, although there was a higher incidence of rectifiable equinus deformity in these patients


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 232 - 237
1 Feb 2006
Saridis A Panagiotopoulos E Tyllianakis M Matzaroglou C Vandoros N Lambiris E

We reviewed 13 patients with infected nonunion of the distal femur and bone loss, who had been treated by radical surgical debridement and the application of an Ilizarov external fixator. All had severely restricted movement of the knee and a mean of 3.1 previous operations. The mean length of the bony defect was 8.3 cm and no patient was able to bear weight. The mean external fixation time was 309.8 days. According to Paley’s grading system, eight patients had an excellent clinical and radiological result and seven excellent and good functional results. Bony union, the ability to bear weight fully, and resolution of the infection were achieved in all the patients. The external fixation time was increased when the definitive treatment started six months or more after the initial trauma, the patient had been subjected to more than four previous operations and the initial operation had been open reduction and internal fixation


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 783 - 789
1 Jun 2006
Sen C Eralp L Gunes T Erdem M Ozden VE Kocaoglu M

In this retrospective study we evaluated the method of acute shortening and distraction osteogenesis for the treatment of tibial nonunion with bone loss in 17 patients with a mean age of 36 years (10 to 58). The mean bone loss was 5.6 cm (3 to 10). In infected cases, we performed the treatment in two stages. The mean follow-up time was 43.5 months (24 to 96). The mean time in external fixation was 8.0 months (4 to 13) and the mean external fixator index was 1.4 months/cm (1.1 to 1.8). There was no recurrence of infection. The bone evaluation results were excellent in 16 patients and good in one, while functional results were excellent in 15 and good in two. The complication rate was 1.2 per patient. We conclude that acute shortening and distraction osteogenesis is a safe, reliable and successful method for the treatment of tibial nonunion with bone loss, with a shorter period of treatment and lower rate of complication


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 80 - 88
1 Jan 2007
El-Rosasy MA

We have managed 21 patients with a fracture of the tibia complicated by bone and soft-tissue loss as a result of an open fracture in 10, or following debridement of an infected nonunion in 11, by resection of all the devitalised tissues, acute limb shortening to close the defect, application of an external fixator and metaphyseal osteotomy for re-lengthening. The mean bone loss was 4.7 cm (3 to 11). The mean age of the patients was 28.8 years (12 to 54) and the mean follow-up was 34.8 months (24 to 75). All the fractures united with a well-aligned limb. The mean duration of treatment for the ten grade-III A+B open fractures (according to the Gustilo-Anderson classification) was 5.7 months (4.5 to 8) and for the nonunions, 7.6 months (5.5 to 12.5). Complications included one refracture, one transient palsy of the peroneal nerve and one equinus contracture of 10°


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 795 - 800
1 Jun 2008
Liu T Zhang X Li Z Zeng W Peng D Sun C

Nonunion of the humerus with bone loss and shortening due to osteomyelitis is rare but difficult to treat. We describe our experience with a callus distraction technique using a monolateral external fixator for the treatment of this condition. Between October 1994 and January 2004, 11 patients were treated. There were seven males and four females, with a mean age of 14 years (10 to 17). The mean bone loss was 1.9 cm (1 to 2.7) and the mean length discrepancy in the upper limb was 5.6 cm (3.5 to 8.0). The mean follow-up was for 106 months (54 to 166). The mean external fixation index was 34.8 days/cm (29.8 to 40.5). The mean lengthening was 9.5 cm (5.5 to 13.4). There were seven excellent results, three good and one poor. There were nine excellent functional results and two good. The treatment of humeral nonunion with bone loss and shortening due to osteomyelitis by callus distraction is a safe and effective means of improving function and cosmesis


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 4 | Pages 540 - 543
1 Apr 2005
Kazuki K Hiroshima K Kawahara K

Deformity of the forearm due to growth disturbance of the ulna occurs in a number of conditions such as ulnar deficiency, multiple exostoses, and neurofibromatosis. We report a previously unrecognised form, caused by focal cortical indentation. We have treated five children with this condition, three girls and two boys; the mean age at presentation was 5 years (2 to 8). The deformity was first recognised about the age of two years, and progressed gradually. The radiological findings were the same in all cases. The focal cortical indentation was seen at the distal end of the ulna with anteromedial bowing and dysplasia. The radial head was dislocated posterolaterally. In one patient the histological findings at the site of indentation were of a fold of tissue resembling periosteum, which interfered with enchondral ossification. Treatment by ulnar lengthening using an external fixator and osteotomy which corrected both the ulnar deformity and reduced the dislocated radial head in two cases gave the best results


Bone & Joint Research
Vol. 1, Issue 11 | Pages 289 - 296
1 Nov 2012
Savaridas T Wallace RJ Muir AY Salter DM Simpson AHRW

Objectives. Small animal models of fracture repair primarily investigate indirect fracture healing via external callus formation. We present the first described rat model of direct fracture healing. Methods. A rat tibial osteotomy was created and fixed with compression plating similar to that used in patients. The procedure was evaluated in 15 cadaver rats and then in vivo in ten Sprague-Dawley rats. Controls had osteotomies stabilised with a uniaxial external fixator that used the same surgical approach and relied on the same number and diameter of screw holes in bone. Results. Fracture healing occurred without evidence of external callus on plain radiographs. At six weeks after fracture fixation, the mean stress at failure in a four-point bending test was 24.65 N/mm. 2. (. sd. 6.15). Histology revealed ‘cutting-cones’ traversing the fracture site. In controls where a uniaxial external fixator was used, bone healing occurred via external callus formation. Conclusions. A simple, reproducible model of direct fracture healing in rat tibia that mimics clinical practice has been developed for use in future studies of direct fracture healing


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 2 | Pages 207 - 211
1 Mar 1987
Jenkins N Jones D Johnson Mintowt-Czyz W

In a prospective, controlled study 58 patients aged under 60 years with Colles' fractures were treated either by a forearm plaster or by the application of an external fixator. In 94% of those treated by a fixator it was possible to insert the distal pins of the frame into the fracture fragment, the fixation obtained being sufficient to forgo additional splintage. The external fixator proved more effective at holding the manipulated position, and the radiological loss of position during fracture union was minimal compared with that seen in patients treated in plaster


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 863 - 866
1 Jun 2005
Nagarajah K Aslam N McLardy Smith P McNally M

We describe a technique of ‘cross-hip distraction’ to reduce a dislocated hip with subsequent reconstruction of the joint for septic arthritis with extensive femoral osteomyelitis. A 27-year-old woman presented with a dislocated, collapsed femoral head and chronic osteomyelitis of the femur. Examination revealed a leg-length discrepancy of 7 cm and an irritable hip. A staged technique was used with primary clearance of osteomyelitis and secondary reconstruction of the hip. A cross-hip monolateral external fixator was used to establish normal anatomy followed by an arthroplasty. A good functional outcome was achieved. The use of cross-hip distraction avoids soft-tissue and nerve damage and achieved improved abductor function before arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 9 | Pages 1201 - 1207
1 Sep 2009
Lefaivre KA Starr AJ Barker BP Overturf S Reinert CM

We describe our early operative experience with a new pelvic reduction frame and the standard of reduction of fractures of the pelvic ring which we achieved in the first 35 consecutive patients, with 34 acute fractures and one nonunion. The pre-operative and immediate post-operative radiographs were measured, using two methods, to find the maximum radiological displacement of the fracture and the quality of the reduction according to the criteria of Tornetta and Matta. There were 19 vertical shear fractures and 16 compression injuries. The mean age of the patients was 33.5 years (10 to 59) and mean delay to surgery was 4.6 days (0 to 16) in the 34 acute injuries. The mean operative time in isolated procedures was 103.4 minutes (. sd. 6.5). All but one patient had iliosacral screws implanted, 18 had screws in the anterior column, six had plates at the symphysis pubis and 12 had anterior external fixators. The mean maximum horizontal or vertical displacement was improved from 30.8 mm (. sd. 2.7) to a mean of 7.1 mm (. sd. 0.7). The reduction was assessed as excellent in ten patients, good in 18, and fair in the remainder. There was no significant influence on the quality of the reduction caused by obesity (p = 0.34), the type of fracture (p = 0.41) or delay to surgery (p = 0.83). The frame was shown to be effective, allowing the surgeon to obtain a satisfactory reduction and fixation of acute displaced disruptions of the pelvic ring


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 6 | Pages 790 - 793
1 Jun 2007
Norrish AR Lewis CP Harrison WJ

Patients infected with HIV presenting with an open fracture of a long bone are difficult to manage. There is an unacceptably high rate of post-operative infection after internal fixation. There are no published data on the use of external fixation in such patients. We compared the rates of pin-track infection in HIV-positive and HIV-negative patients presenting with an open fracture. There were 47 patients with 50 external fixators, 13 of whom were HIV-positive (15 fixators). There were significantly more pin-track infections requiring pharmaceutical or surgical intervention (Checketts grade 2 or greater) in the HIV-positive group (t-test, p = 0.001). The overall rate of severe pin-track infection in the HIV-positive patients requiring removal of the external-fixator pins was 7%. This contrasts with other published data which have shown higher rates of wound infection if open fractures are treated by internal fixation. We recommend the use of external fixation for the treatment of open fractures in HIV-positive patients


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 1000 - 1004
1 Jul 2005
Baumgart R Bürklein D Hinterwimmer S Thaller P Mutschler W

Ollier’s disease is characterised by severe deformity of the extremities and retarded growth because of multiple enchondromas. For correction of deformity, the Ilizarov method has been used although it has many complications. A 17-year-old boy with Ollier’s disease had a limb-length discrepancy of 17.4 cm, with a valgus deformity of the right knee and recurvatum of the femur of 23°. He had undergone three unsuccessful attempts to correct the deformities by using external fixators. We used a fully implantable, motorised, lengthening and correction nail (Fitbone) to achieve full correction of all the deformities without complications. We decided to carry out the procedure in three stages. First, we lengthened the femur by 3.6 cm and the tibia by 4 cm. We then exchanged the femoral nail for a longer implant and achieved a further 6 cm of length. This reduced the shortening to 3.8 cm. When the boy has finished secondary school we will adjust the remaining discrepancy


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 8 | Pages 1077 - 1083
1 Aug 2007
Tsuchiya H Morsy AF Matsubara H Watanabe K Abdel-Wanis ME Tomita K

We present a retrospective study of patients suffering from a variety of benign tumours in whom external fixators were used to treat deformity and limb-length discrepancy, and for the reconstruction of bone defects. A total of 43 limbs in 31 patients (12 male and 19 female) with a mean age of 14 years (2 to 54) were treated. The diagnosis was Ollier’s disease in 12 limbs, fibrous dysplasia in 11, osteochondroma in eight, giant cell tumour in five, osteofibrous dysplasia in five and non-ossifying fibroma in two. The lesions were treated in the tibia in 19 limbs, in the femur in 16, and in the forearm in eight. The Ilizarov frame was used in 25 limbs, the Taylor Spatial Frame in seven, the Orthofix fixator in six, the Monotube in four and the Heidelberg fixator in one. The mean follow-up was 72 months (22 to 221). The mean external fixation period was 168 days (71 to 352). The mean external fixation index was 42 days/cm (22.2 to 102.0) in the 22 patients who required limb lengthening. The mean correction angle for those with angular deformity was 23° (7° to 45°). At final follow-up all patients had returned to normal activities. Four patients required a second operation for recurrent deformity of further limb lengthening. Local recurrence occurred in one patient, requiring further surgery


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 557 - 564
1 Apr 2009
Rumian AP Draper ERC Wallace AL Goodship AE

An understanding of the remodelling of tendon is crucial for the development of scientific methods of treatment and rehabilitation. This study tested the hypothesis that tendon adapts structurally in response to changes in functional loading. A novel model allowed manipulation of the mechanical environment of the patellar tendon in the presence of normal joint movement via the application of an adjustable external fixator mechanism between the patella and the tibia in sheep, while avoiding exposure of the patellar tendon itself. Stress shielding caused a significant reduction in the structural and material properties of stiffness (79%), ultimate load (69%), energy absorbed (61%), elastic modulus (76%) and ultimate stress (72%) of the tendon compared with controls. Compared with the material properties the structural properties exhibited better recovery after re-stressing with stiffness 97%, ultimate load 92%, energy absorbed 96%, elastic modulus 79% and ultimate stress 80%. The cross-sectional area of the re-stressed tendons was significantly greater than that of stress-shielded tendons. The remodelling phenomena exhibited in this study are consistent with a putative feedback mechanism under strain control. This study provides a basis from which to explore the interactions of tendon remodelling and mechanical environment


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 3 | Pages 448 - 451
1 May 1991
Thakur A Patankar J

Seventy-nine open tibial fractures were treated with unilateral uniplanar tubular external fixators. Excellent stability allowed early weight-bearing. All comminuted fractures, with or without bone loss, and some transverse or short oblique fractures with intermediate fragments were treated by early bone grafting through a posterolateral approach. The external fixator was dynamised as soon as periosteal callus was seen on the radiograph. Bone healing times ranged from 11 to 40 weeks (mean 20). Significant ankle stiffness occurred in 10.9% and leg shortening in 2.8%. Pin track infection was seen in 45.2% but was easily controlled with standard management. The external fixation frame allowed excellent functional freedom for Oriental patients to sit cross-legged and squat. Combined with early bone grafting, external fixation is an excellent method for the management of open tibial fractures


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1628 - 1633
1 Dec 2015
Elmadag M Uzer G Yildiz F Erden T Bilsel K Büyükpinarbasili N Üsümez A Bozdag E Sen C

This animal study compares different methods of performing an osteotomy, including using an Erbium-doped Yttrium Aluminum Garnet laser, histologically, radiologically and biomechanically. A total of 24 New Zealand rabbits were divided into four groups (Group I: multihole-drilling; Group II: Gigli saw; Group III: electrical saw blade and Group IV: laser). A proximal transverse diaphyseal osteotomy was performed on the right tibias of the rabbits after the application of a circular external fixator. The rabbits were killed six weeks after the procedure, the operated tibias were resected and radiographs taken. . The specimens were tested biomechanically using three-point bending forces, and four tibias from each group were examined histologically. Outcome parameters were the biomechanical stability of the tibias as assessed by the failure to load and radiographic and histological examination of the osteotomy site. . The osteotomies healed in all specimens both radiographically and histologically. The differences in the mean radiographic (p = 0.568) and histological (p = 0.71) scores, and in the mean failure loads (p = 0.180) were not statistically significant between the groups. . Different methods of performing an osteotomy give similar quality of union. The laser osteotomy, which is not widely used in orthopaedics is an alternative to the current methods. Cite this article: Bone Joint J 2015;97-B:1628–33


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 2 | Pages 259 - 265
1 Mar 2004
Saldanha KAN Saleh M Bell MJ Fernandes JA

We performed limb lengthening and correction of deformity of nine long bones of the lower limb in six children (mean age, 14.7 years) with osteogenesis imperfecta (OI). All had femoral lengthening and three also had ipsilateral tibial lengthening. Angular deformities were corrected simultaneously. Five limb segments were treated using a monolateral external fixator and four with the Ilizarov frame. In three children, lengthening was done over previously inserted femoral intramedullary rods. The mean lengthening achieved was 6.26 cm (mean healing index, 33.25 days/cm). Significant complications included one deep infection, one fracture of the femur and one anterior angulation deformity of the tibia. The abnormal bone of OI tolerated the external fixators throughout the period of lengthening without any episodes of migration of wires or pins through the soft bone. The regenerate bone formed within the time which is normally expected in limb-lengthening procedures performed for other conditions. We conclude that despite the abnormal bone characteristics, distraction osteogenesis to correct limb-length discrepancy and angular deformity can be performed safely in children with OI


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 11 | Pages 1472 - 1477
1 Nov 2009
Lee W Yoo JH Moon J

We carried out a retrospective study to assess the clinical results of lengthening the fourth metatarsal in brachymetatarsia in 153 feet of 106 patients (100 female, six males) using three different surgical techniques. In one group lengthening was performed by one-stage intercalary bone grafting secured by an intramedullary Kirschner-wire (45 feet, 35 patients). In the second group lengthening was obtained gradually using a mini-external fixator after performing an osteotomy with a saw (59 feet, 39 patients) and in the third group lengthening was achieved in a gradual manner using a mini-external fixator after undertaking an osteotomy using osteotome through pre-drilled holes (49 feet, 32 patients). The mean age of the patients was 26.3 years (13 to 48). Pre-operatively, the fourth ray of the bone-graft group was longer than that of other two groups (p < 0.000). The clinical outcome was compared in the three groups. The mean follow-up was 22 months (7 to 55). At final follow-up, the mean lengthening in the bone-graft group was 13.9 mm (3.5 to 23.0, 27.1%) which was less than that obtained in the saw group with a mean of 17.8 mm (7.0 to 33.0, 29.9%) and in the pre-drilled osteotome group with a mean of 16.8 mm (6.5 to 28.0, 29.4%, p = 0.001). However, the mean time required for retention of the fixation in the bone-graft group was the shortest of the three groups. Patients were dissatisfied with the result for five feet (11.1%) in the bone-graft group, eight (13.6%) in the saw group and none in the pre-drilled osteotomy group (p < 0.000). The saw group included eight feet with failure of bone formation after surgery. Additional operations were performed in 20 feet because of stiffness (n = 7, all groups), failure of bone formation (n = 4, saw group), skin maceration (n = 4, bone-graft group), malunion (n = 4, bone-graft and saw groups) and breakage of the external fixator (n = 1, saw group). We conclude that the gradual lengthening by distraction osteogenesis after osteotomy using an osteotome produces the most reliable results for the treatment of fourth brachymetatarsia


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 6 | Pages 868 - 875
1 Aug 2004
Okcu G Aktuglu K

We retrospectively reviewed 60 fractures of the tibial plafond treated by either an ankle-sparing diaphyseal-epiphyseal technique using the Ilizarov ring fixator or by an ankle-spanning technique using a monolateral articulated external fixator. The Ilizarov ring fixator was applied in 24 fractures and the monolateral articulated transarticular external fixator in 20. Both techniques were combined with limited open reduction and internal fixation of the articular surface if necessary. Between three and nine years after the injury, all patients returned for clinical and radiological assessment and evaluation of ankle function using the modified Mazur score. There were no significant differences between the two groups in terms of age, gender, mechanism of injury, type of fracture or length of follow-up. The mean functional ankle score was 86 points for the Ilizarov group and 82 points for the articulated fixator group. The difference was not significant (p = 0.07). There were no significant differences between the groups with regard to the radiographic score and late complications. Patients treated with the Ilizarov ring fixator had significantly better ankle and subtalar movement. We conclude that both techniques of external fixation are satisfactory methods of treatment for fractures of the tibial plafond, but that the total arc of movement of the joint is preserved better without bridging the ankle


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 5 | Pages 721 - 729
1 May 2005
Yanai T Ishii T Chang F Ochiai N

We produced large full-thickness articular cartilage defects in 33 rabbits in order to evaluate the effect of joint distraction and autologous culture-expanded bone-marrow-derived mesenchymal cell transplantation (ACBMT) at 12 weeks. After fixing the knee on a hinged external fixator, we resected the entire surface of the tibial plateau. We studied three groups: 1) with and without joint distraction; 2) with joint distraction and collagen gel, and 3) with joint distraction and ACBMT and collagen gel. The histological scores were significantly higher in the groups with ACBMT collagen gel (p < 0.05). The area of regenerated soft tissue was smaller in the group allowed to bear weight (p < 0.05). These findings suggest that the repair of large defects of cartilage can be enhanced by joint distraction, collagen gel and ACBMT