This article is a systematic review of the published
literature about the biomechanics, functional outcome and complications
of intramedullary nailing of fractures of the distal radius. We searched the Medline and EMBASE databases and included all
studies which reported the outcome of intramedullary (IM) nailing
of fractures of the distal radius. Data about functional outcome,
range of movement (ROM), strength and complications, were extracted.
The studies included were appraised independently by both authors
using a validated quality assessment scale for non-controlled studies
and the CONSORT statement for randomised controlled trials (RCTs). The search strategy revealed 785 studies, of which 16 were included
for full paper review. These included three biomechanical studies,
eight case series and five randomised controlled trials (RCTs). The biomechanical studies concluded that IM nails were at least
as strong as locking plates. The clinical studies reported that
IM nailing gave a comparable ROM, functional outcome and grip strength
to other fixation techniques. However, the mean complication rate of intramedullary nailing
was 17.6% (0% to 50%). This is higher than the rates reported in
contemporary studies for volar plating. It raises concerns about
the role of intramedullary nailing, particularly when comparative
studies have failed to show that it has any major advantage over
other techniques. Further adequately powered RCTs comparing the
technique to both volar plating and percutaneous wire fixation are needed. Cite this article:
We investigated the changes seen on serial metal
artefact reduction magnetic resonance imaging scans (MARS-MRI) of
metal-on-metal total hip arthroplasties (MoM THAs). In total 155
THAs, in 35 male and 100 female patients (mean age 70.4 years, 42
to 91), underwent at least two MRI scans at a mean interval of 14.6
months (2.6 to 57.1), at a mean of 48.2 months (3.5 to 93.3) after
primary hip surgery. Scans were graded using a modification of the
Oxford classification. Progression of disease was defined as an
increase in grade or a minimum 10% increase in fluid lesion volume
at second scan. A total of 16 hips (30%) initially classified as
‘normal’ developed an abnormality on the second scan. Of those with
‘isolated trochanteric fluid’ 9 (47%) underwent disease progression,
as did 7 (58%) of ‘effusions’. A total of 54 (77%) of hips initially
classified as showing adverse reactions to metal debris (ARMD) progressed,
with higher rates of progression in higher grades. Disease progression
was associated with high blood cobalt levels or an irregular pseudocapsule
lining at the initial scan. There was no association with changes
in functional scores. Adverse reactions to metal debris in MoM THAs
may not be as benign as previous reports have suggested. Close radiological
follow-up is recommended, particularly in high-risk groups. Cite this article:
The June 2015 Wrist &
Hand Roundup360 looks at: Collagenase and Dupuytren’s disease – a genuine alternative to surgery?; iPad PROMise?; Should we learn how to do endoscopic carpal tunnel release?; Two-week radiographs a relic of the past?; Bible? Aspirate or excise?; Patient expectations and trapeziometacarpal osteoarthritis; Splintage in the treatment of sagittal band incompetence and extensor tendon subluxation
Osteoid osteoma is treated primarily by radiofrequency
(RF) ablation. However, there is little information about the distribution
of heat in bone during the procedure and its safety. We constructed
a model of osteoid osteoma to assess the distribution of heat in
bone and to define the margins of safety for ablation. Cavities
were drilled in cadaver bovine bones and filled with a liver homogenate
to simulate the tumour matrix. Temperature-sensing probes were placed
in the bone in a radial fashion away from the cavities. RF ablation
was performed 107 times in tumours <
10 mm in diameter (72 of
which were in cortical bone, 35 in cancellous bone), and 41 times
in cortical bone with models >
10 mm in diameter. Significantly
higher temperatures were found in cancellous bone than in cortical
bone (p <
0.05). For lesions up to 10 mm in diameter, in both
bone types, the temperature varied directly with the size of the
tumour (p <
0.05), and inversely with the distance from it. Tumours
of >
10 mm in diameter showed a trend similar to those of smaller
lesions. No temperature rise was seen beyond 12 mm from the edge
of a cortical tumour of any size. Formulae were developed to predict
the expected temperature in the bone during ablation. Cite this article:
Patient function after arthroplasty should ideally quickly improve.
It is not known which peri-operative function assessments predict
length of stay (LOS) and short-term functional recovery. The objective
of this study was to identify peri-operative functions assessments
predictive of hospital LOS and short-term function after hospital discharge
in hip or knee arthroplasty patients. In total, 108 patients were assessed peri-operatively with the
timed-up-and-go (TUG), Iowa level of assistance scale, post-operative
quality of recovery scale, readiness for hospital discharge scale,
and the Western Ontario and McMaster Osteoarthritis Index (WOMAC).
The older Americans resources and services activities of daily living
(ADL) questionnaire (OARS) was used to assess function two weeks
after discharge. Objectives
Methods
The February 2014 Children’s orthopaedics Roundup360 looks at: flexible plasters; dual 8-plate or ablation for knee epiphysiodesis; ultrasounds for pulled elbow; leg length without the radiation; Boyd amputation in limb deficiencies; gold standard club foot treatment; quadrupled semitendinosis graft effective in paediatric ACL reconstruction; and predicting complications following cerebral palsy hip reconstruction
Knee arthrodesis is a potential salvage procedure
for limb preservation after failure of total knee arthroplasty (TKA) due
to infection. In this study, we evaluated the outcome of single-stage
knee arthrodesis using an intramedullary cemented coupled nail without
bone-on-bone fusion after failed and infected TKA with extensor
mechanism deficiency. Between 2002 and 2012, 27 patients (ten female,
17 male; mean age 68.8 years; 52 to 87) were treated with septic
single-stage exchange. Mean follow-up duration was 67.1months (24
to 143, n = 27) (minimum follow-up 24 months) and for patients with
a minimum follow-up of five years 104.9 (65 to 143,; n = 13). A
subjective patient evaluation (Short Form (SF)-36) was obtained,
in addition to the Visual Analogue Scale (VAS). The mean VAS score was
1.44 (SD 1.48). At final follow-up, four patients had recurrent
infections after arthrodesis (14.8%). Of these, three patients were
treated with a one-stage arthrodesis nail exchange; one of the three
patients had an aseptic loosening with a third single-stage exchange,
and one patient underwent knee amputation for uncontrolled sepsis at
108 months. All patients, including the amputee, indicated that
they would choose arthrodesis again. Data indicate that a single-stage
knee arthrodesis offers an acceptable salvage procedure after failed
and infected TKA. Cite this article:
The June 2015 Knee Roundup360 looks at: Cruciate substituting
The April 2015 Research Roundup360 looks at: MCID in grip strength and distal radial fracture; Experiencing rehab in a trial setting; Electrical stimulation and nerve recovery; Molecular diagnosis of TB?; Acetabular orientation: component and arthritis; Analgesia after knee arthroplasty; Bisphosphonate-associated femoral fractures
The aim of this study was to assess the effect
of injecting genetically engineered chondrocytes expressing transforming
growth factor beta 1 (TGF-β1) into the knees of patients with osteoarthritis.
We assessed the resultant function, pain and quality of life. A total of 54 patients (20 men, 34 women) who had a mean age
of 58 years (50 to 66) were blinded and randomised (1:1) to receive
a single injection of the active treatment or a placebo. We assessed
post-treatment function, pain severity, physical function, quality
of life and the incidence of treatment-associated adverse events. Patients
were followed at four, 12 and 24 weeks after injection. At final follow-up the treatment group had a significantly greater
improvement in the mean International Knee Documentation Committee
score than the placebo group (16 points; -18 to 49, This technique may result in improved clinical outcomes, with
the aim of slowing the degenerative process, leading to improvements
in pain and function. However, imaging and direct observational
studies are needed to verify cartilage regeneration. Nevertheless,
this study provided a sufficient basis to proceed to further clinical testing. Cite this article:
Matrix-assisted autologous chondrocyte transplantation (MACT)
has been developed and applied in the clinical practice in the last
decade to overcome most of the disadvantages of the first generation
procedures. The purpose of this systematic review is to document
and analyse the available literature on the results of MACT in the
treatment of chondral and osteochondral lesions of the knee. All studies published in English addressing MACT procedures were
identified, including those that fulfilled the following criteria:
1) level I-IV evidence, 2) measures of functional or clinical outcome,
3) outcome related to cartilage lesions of the knee cartilage.Objectives
Methods
Salubrinal is a synthetic agent that elevates phosphorylation
of eukaryotic translation initiation factor 2 alpha (eIF2α) and
alleviates stress to the endoplasmic reticulum. Previously, we reported
that in chondrocytes, Salubrinal attenuates expression and activity
of matrix metalloproteinase 13 (MMP13) through downregulating nuclear
factor kappa B (NFκB) signalling. We herein examine whether Salubrinal
prevents the degradation of articular cartilage in a mouse model
of osteoarthritis (OA). OA was surgically induced in the left knee of female mice. Animal
groups included age-matched sham control, OA placebo, and OA treated
with Salubrinal or Guanabenz. Three weeks after the induction of
OA, immunoblotting was performed for NFκB p65 and p-NFκB p65. At
three and six weeks, the femora and tibiae were isolated and the sagittal
sections were stained with Safranin O.Objectives
Methods
The major problem with repair of an articular cartilage injury
is the extensive difference in the structure and function of regenerated,
compared with normal cartilage. Our work investigates the feasibility
of repairing articular osteochondral defects in the canine knee
joint using a composite lamellar scaffold of nano-ß-tricalcium phosphate
(ß-TCP)/collagen (col) I and II with bone marrow stromal stem cells
(BMSCs) and assesses its biological compatibility. The bone–cartilage scaffold was prepared as a laminated composite,
using hydroxyapatite nanoparticles (nano-HAP)/collagen I/copolymer
of polylactic acid–hydroxyacetic acid as the bony scaffold, and
sodium hyaluronate/poly(lactic-co-glycolic acid) as the cartilaginous
scaffold. Ten-to 12-month-old hybrid canines were randomly divided
into an experimental group and a control group. BMSCs were obtained
from the iliac crest of each animal, and only those of the third
generation were used in experiments. An articular osteochondral
defect was created in the right knee of dogs in both groups. Those
in the experimental group were treated by implanting the composites
consisting of the lamellar scaffold of ß-TCP/col I/col II/BMSCs.
Those in the control group were left untreated.Objectives
Methods
The December 2014 Wrist &
Hand Roundup360 looks at: ultrasound for carpal tunnel diagnosis; where we are at with management of undisplaced scaphoid fractures; ARPE for thumb metacarpals?; extravasation injuries in the hand and wrist; research and practice in hand surgery; and physio ineffective in hand osteoarthritis
Fresh-frozen allograft bone is frequently used
in orthopaedic surgery. We investigated the incidence of allograft-related
infection and analysed the outcomes of recipients of bacterial culture-positive
allografts from our single-institute bone bank during bone transplantation.
The fresh-frozen allografts were harvested in a strict sterile environment
during total joint arthroplasty surgery and immediately stored in
a freezer at -78º to -68º C after packing. Between January 2007
and December 2012, 2024 patients received 2083 allografts with a
minimum of 12 months of follow-up. The overall allograft-associated
infection rate was 1.2% (24/2024). Swab cultures of 2083 allografts
taken before implantation revealed 21 (1.0%) positive findings.
The 21 recipients were given various antibiotics at the individual
orthopaedic surgeon’s discretion. At the latest follow-up, none
of these 21 recipients displayed clinical signs of infection following
treatment. Based on these findings, we conclude that an incidental positive
culture finding for allografts does not correlate with subsequent
surgical site infection. Additional prolonged post-operative antibiotic
therapy may not be necessary for recipients of fresh-frozen bone
allograft with positive culture findings. Cite this article:
A total of seven patients (six men and one woman)
with a defect in the Achilles tendon and overlying soft tissue underwent
reconstruction using either a composite radial forearm flap (n =
3) or an anterolateral thigh flap (n = 4). The Achilles tendons
were reconstructed using chimeric palmaris longus (n = 2) or tensor
fascia lata (n = 2) flaps or transfer of the flexor hallucis longus
tendon (n = 3). Surgical parameters such as the rate of complications
and the time between the initial repair and flap surgery were analysed.
Function was measured objectively by recording the circumference
of the calf, the isometric strength of the plantar flexors and the
range of movement of the ankle. The Achilles tendon Total Rupture
Score (ATRS) questionnaire was used as a patient-reported outcome
measure. Most patients had undergone several previous operations
to the Achilles tendon prior to flap surgery. The mean time to flap
surgery was 14.3 months (2.1 to 40.7). At a mean follow-up of 32.3 months (12.1 to 59.6) the circumference
of the calf on the operated lower limb was reduced by a mean of
1.9 cm ( These otherwise indicate that reconstruction of the Achilles
tendon combined with flap cover results in a successful and functional
reconstruction. Cite this article:
The purpose of this study was to investigate whether the femoral
head–neck contour, characterised by the alpha angle, varies with
the stage of physeal maturation using MRI evaluation of an asymptomatic
paediatric population. Paediatric volunteers with asymptomatic hips were recruited to
undergo MRI of both hips. Femoral head physes were graded from 1
(completely open) to 6 (completely fused). The femoral head–neck
contour was evaluated using the alpha angle, measured at the 3:00
(anterior) and 1:30 (anterosuperior) positions and correlated with
physeal grade, with gender sub-analysis performed.Objectives
Methods
Dunkin Hartley guinea pigs, a commonly used animal model of osteoarthritis,
were used to determine if high frequency ultrasound can ensure intra-articular
injections are accurately positioned in the knee joint. A high-resolution small animal ultrasound system with a 40 MHz
transducer was used for image-guided injections. A total of 36 guinea
pigs were anaesthetised with isoflurane and placed on a heated stage.
Sterile needles were inserted directly into the knee joint medially,
while the transducer was placed on the lateral surface, allowing
the femur, tibia and fat pad to be visualised in the images. B-mode
cine loops were acquired during 100 µl. We assessed our ability
to visualise 1) important anatomical landmarks, 2) the needle and
3) anatomical changes due to the injection. Objective
Methods
The December 2014 Hip &
Pelvis Roundup360 looks at: Sports and total hips; topical tranexamic acid and blood conservation in hip replacement; blind spots and biases in hip research; no recurrence in cam lesions at two years; to drain or not to drain?; sonication and diagnosis of implant associated infection; and biomarkers and periprosthetic infection
It has been suggested that extracorporeal shockwave
therapy is a safe and effective treatment for pain relief from recalcitrant
plantar fasciopathy (PF). However, the changes in gait and associated
biomechanical parameters have not been well characterised. We recruited
12 female patients with recalcitrant PF who had a mean age of 59
years (50 to 70) and mean body mass index of 25 kg/m2 (22
to 30). The patients reported a mean duration of symptoms of 9.3
months (6 to 15). Shockwave therapy consisting of 1500 impulses
(energy flux density 0.26 mJ/mm2) was applied for three
sessions, each three weeks apart. A pain visual analogue scale (VAS)
rating, plantar pressure assessment and motion analysis were carried
out before and nine weeks after first shock wave therapy. It was demonstrated
that patients increased their walking velocity and cadence as well
indicating a decrease in pain after shockwave therapy. In the symptomatic
foot, the peak contact pressure over the forefoot increased and
the contact area over the digits decreased. The total foot impulse
also decreased as did stance duration. The duration the centre of
pressure remained in the hindfoot increased in the symptomatic foot
after shockwave therapy. The differences in centre of pressure trajectory
at baseline decreased at final follow-up. In conclusion, shockwave
therapy not only decreased the pain VAS rating but also improved
the gait parameters of the symptomatic foot in PF patients. Cite this article: