Advertisement for orthosearch.org.uk
Results 561 - 580 of 704
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 856 - 861
1 Jun 2010
Emms NW Stockley I Hamer AJ Wilkinson JM

Between 1988 and 1998 we implanted 318 total hip replacements (THRs) in 287 patients using the Plasmacup (B. Braun Ltd, Sheffield, United Kingdom) and a conventional metal-on-polyethylene articulation. The main indications for THR were primary or secondary osteoarthritis.

At follow-up after a mean 11.6 years (7.6 to 18.4) 17 patients had died and 20 could not be traced leaving a final series of 280 THRs in 250 patients. There were 62 revisions (22.1%) in 59 patients. A total of 43 acetabular shells (15.4%) had been revised and 13 (4.6%) had undergone exchange of the liner. The most frequent indications for revision were osteolysis and aseptic loosening, followed by polyethylene wear. The mean Kaplan-Meier survival of the Plasmacup was 91% at ten years and 58% at 14 years. Osteolysis was found around 36 (17.1%) of the 211 surviving shells. The median annual rate of linear wear in the surviving shells was 0.12 mm/year and 0.25 mm/year in those which had been revised (p < 0.001). Polyethylene wear was a strong independent risk factor for osteolysis and aseptic loosening. The percentage of patients with osteolysis increased proportionately with each quintile of wear-rate.

There is a high late rate of failure of the Plasmacup. Patients with the combination of this prosthesis and bearing should be closely monitored after ten years.


Bone & Joint 360
Vol. 1, Issue 6 | Pages 30 - 32
1 Dec 2012

The December 2012 Research Roundup360 looks at: whether the rheumatoid factor is just a ‘quick test’; osteonecrosis in smokers; pasteurisation effect on bone reconstruction; venous thromboembolism risk in rheumatoids; whether stem cells reverse age-related osteopenia; the effect of running on rat knees; rapid fracture healing in rats with ultrasound; magnetic stem cells; and the safety of surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 12 | Pages 1585 - 1593
1 Dec 2008
Henricson A Linder L Nilsson KG

We compared the performance of uncemented trabecular metal tibial components in total knee replacement with that of cemented tibial components in patients younger than 60 years over two years using radiostereophotogrammetric analysis (RSA). A total of 22 consecutive patients (mean age 53 years, 33 to 59, 26 knees) received an uncemented NexGen trabecular metal cruciate-retaining monobloc tibial component and 19 (mean 53 years, 44 to 59, 21 knees) a cemented NexGen Option cruciate-retaining modular tibial component.

All the trabecular metal components migrated during the initial three months and then stabilised. The exception was external rotation, which did not stabilise until 12 months. Unlike conventional metal-backed implants which displayed a tilting migration comprising subsidence and lift-off from the tibial tray, most of the trabecular metal components showed subsidence only, probably due to the elasticity of the implant.

This pattern of subsidence is regarded as being beneficial for uncemented fixation.


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 244 - 249
1 Feb 2013
Puig-Verdié L Alentorn-Geli E González-Cuevas A Sorlí L Salvadó M Alier A Pelfort X Portillo ME Horcajada JP

The purpose of this study was to compare the diagnostic accuracy for the detection of infection between the culture of fluid obtained by sonication (SFC) and the culture of peri-implant tissues (PITC) in patients with early and delayed implant failure, and those with unsuspected and suspected septic failure. It was hypothesised that SFC increases the diagnostic accuracy for infection in delayed, but not early, implant failure, and in unsuspected septic failure. The diagnostic accuracy for infection of all consecutive implants (hardware or prostheses) that were removed for failure was compared between SFC and PITC. This prospective study included 317 patients with a mean age of 62.7 years (9 to 97). The sensitivity for detection of infection using SFC was higher than using PITC in an overall comparison (89.9% versus 67%, respectively; p < 0.001), in unsuspected septic failure (100% versus 48.5%, respectively; p < 0.001), and in delayed implant failure (88% versus 58%, respectively; p < 0.001). PITC sensitivity dropped significantly in unsuspected compared with suspected septic failure (p = 0.007), and in delayed compared with early failure (p = 0.013). There were no differences in specificity.

Sonication is mainly recommended when there is implant failure with no clear signs of infection and in patients with delayed implant failure. In early failure, SFC is not superior to PITC for the diagnosis of infection and, therefore, is not recommended as a routine diagnostic test in these patients.

Cite this article: Bone Joint J 2013;95-B:244–9.


The Bone & Joint Journal
Vol. 95-B, Issue 1 | Pages 95 - 100
1 Jan 2013
Chémaly O Hebert-Davies J Rouleau DM Benoit B Laflamme GY

Early total hip replacement (THR) for acetabular fractures offers accelerated rehabilitation, but a high risk of heterotopic ossification (HO) has been reported. The purpose of this study was to evaluate the incidence of HO, its associated risk factors and functional impact. A total of 40 patients with acetabular fractures treated with a THR weres retrospectively reviewed. The incidence and severity of HO were evaluated using the modified Brooker classification, and the functional outcome assessed. The overall incidence of HO was 38% (n = 15), with nine severe grade III cases. Patients who underwent surgery early after injury had a fourfold increased chance of developing HO. The mean blood loss and operating time were more than twice that of those whose surgery was delayed (p = 0.002 and p < 0.001, respectively). In those undergoing early THR, the incidence of grade III HO was eight times higher than in those in whom THR was delayed (p = 0.01). Only three of the seven patients with severe HO showed good or excellent Harris hip scores compared with eight of nine with class 0, I or II HO (p = 0.049). Associated musculoskeletal injuries, high-energy trauma and head injuries were associated with the development of grade III HO.

The incidence of HO was significantly higher in patients with a displaced acetabular fracture undergoing THR early compared with those undergoing THR later and this had an adverse effect on the functional outcome.

Cite this article: Bone Joint J 2013;95-B:95–100.


The Bone & Joint Journal
Vol. 95-B, Issue 1 | Pages 75 - 80
1 Jan 2013
Dannawi Z Altaf F Harshavardhana NS El Sebaie H Noordeen H

Conventional growing rods are the most commonly used distraction-based devices in the treatment of progressive early-onset scoliosis. This technique requires repeated lengthenings with the patient anaesthetised in the operating theatre. We describe the outcomes and complications of using a non-invasive magnetically controlled growing rod (MCGR) in children with early-onset scoliosis. Lengthening is performed on an outpatient basis using an external remote control with the patient awake.

Between November 2009 and March 2011, 34 children with a mean age of eight years (5 to 12) underwent treatment. The mean length of follow-up was 15 months (12 to 18). In total, 22 children were treated with dual rod constructs and 12 with a single rod. The mean number of distractions per patient was 4.8 (3 to 6). The mean pre-operative Cobb angle was 69° (46° to 108°); this was corrected to a mean 47° (28° to 91°) post-operatively. The mean Cobb angle at final review was 41° (27° to 86°). The mean pre-operative distance from T1 to S1 was 304 mm (243 to 380) and increased to 335 mm (253 to 400) in the immediate post-operative period. At final review the mean distance from T1 to S1 had increased to 348 mm (260 to 420).

Two patients developed a superficial wound infection and a further two patients in the single rod group developed a loss of distraction. In the dual rod group, one patient had pull-out of a hook and one developed prominent metalwork. Two patients had a rod breakage; one patient in the single rod group and one patient in the dual rod group. Our early results show that the MCGR is safe and effective in the treatment of progressive early-onset scoliosis with the avoidance of repeated surgical lengthenings.

Cite this article: Bone Joint J 2013;95-B:75–80.


Bone & Joint 360
Vol. 1, Issue 5 | Pages 26 - 28
1 Oct 2012

The October 2012 Oncology Roundup360 looks at: the causes of primary bone tumours; adjuvant chemotherapy in the longer term; vascularised fibular grafts to salvage massive femoral allografts; a new look at old risks; reconstruction with excised irradiated bone; predicting chemosensitivity in osteosarcoma ; and chemotherapy, osteoporosis and the risk of fracture.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 85 - 89
1 Nov 2012
Drexler M Dwyer T Marmor M Abolghasemian M Sternheim A Cameron HU

In this study we present our experience with four generations of uncemented total knee arthroplasty (TKA) from Smith & Nephew: Tricon M, Tricon LS, Tricon II and Profix, focusing on the failure rates correlating with each design change. Beginning in 1984, 380 Tricon M, 435 Tricon LS, 305 Tricon 2 and 588 Profix were implanted by the senior author. The rate of revision for loosening was 1.1% for the Tricon M, 1.1% for the Tricon LS, 0.5% for the Tricon 2 with a HA coated tibial component, and 1.3% for the Profix TKA. No loosening of the femoral component was seen with the Tricon M, Tricon LS or Tricon 2, with no loosening seen of the tibial component with the Profix TKA. Regarding revision for wear, the incidence was 13.1% for the Tricon M, 6.6% for the Tricon LS, 2.3% for the Tricon 2, and 0% for the Profix. These results demonstrate that improvements in the design of uncemented components, including increased polyethylene thickness, improved polyethylene quality, and the introduction of hydroxyapatite coating, has improved the outcomes of uncemented TKA over time.


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 181 - 187
1 Feb 2013
Liddle AD Pandit H O’Brien S Doran E Penny ID Hooper GJ Burn PJ Dodd CAF Beverland DE Maxwell AR Murray DW

The Cementless Oxford Unicompartmental Knee Replacement (OUKR) was developed to address problems related to cementation, and has been demonstrated in a randomised study to have similar clinical outcomes with fewer radiolucencies than observed with the cemented device. However, before its widespread use it is necessary to clarify contraindications and assess the complications. This requires a larger study than any previously published.

We present a prospective multicentre series of 1000 cementless OUKRs in 881 patients at a minimum follow-up of one year. All patients had radiological assessment aligned to the bone–implant interfaces and clinical scores. Analysis was performed at a mean of 38.2 months (19 to 88) following surgery. A total of 17 patients died (comprising 19 knees (1.9%)), none as a result of surgery; there were no tibial or femoral loosenings. A total of 19 knees (1.9%) had significant implant-related complications or required revision. Implant survival at six years was 97.2%, and there was a partial radiolucency at the bone–implant interface in 72 knees (8.9%), with no complete radiolucencies. There was no significant increase in complication rate compared with cemented fixation (p = 0.87), and no specific contraindications to cementless fixation were identified.

Cementless OUKR appears to be safe and reproducible in patients with end-stage anteromedial osteoarthritis of the knee, with radiological evidence of improved fixation compared with previous reports using cemented fixation.

Cite this article: Bone Joint J 2013;95-B:181–7.


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 151 - 159
1 Feb 2013
Duckworth AD McQueen MM Ring D

Most fractures of the radial head are stable undisplaced or minimally displaced partial fractures without an associated fracture of the elbow or forearm or ligament injury, where stiffness following non-operative management is the primary concern. Displaced unstable fractures of the radial head are usually associated with other fractures or ligament injuries, and restoration of radiocapitellar contact by reconstruction or prosthetic replacement of the fractured head is necessary to prevent subluxation or dislocation of the elbow and forearm. In fractures with three or fewer fragments (two articular fragments and the neck) and little or no metaphyseal comminution, open reduction and internal fixation may give good results. However, fragmented unstable fractures of the radial head are prone to early failure of fixation and nonunion when fixed. Excision of the radial head is associated with good long-term results, but in patients with instability of the elbow or forearm, prosthetic replacement is preferred.

This review considers the characteristics of stable and unstable fractures of the radial head, as well as discussing the debatable aspects of management, in light of the current best evidence.

Cite this article: Bone Joint J 2013;95-B:151–9.


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 747 - 757
1 Jun 2013
Jameson SS Baker PN Mason J Rymaszewska M Gregg PJ Deehan DJ Reed MR

The popularity of cementless total hip replacement (THR) has surpassed cemented THR in England and Wales. This retrospective cohort study records survival time to revision following primary cementless THR with the most common combination (accounting for almost a third of all cementless THRs), and explores risk factors independently associated with failure, using data from the National Joint Registry for England and Wales. Patients with osteoarthritis who had a DePuy Corail/Pinnacle THR implanted between the establishment of the registry in 2003 and 31 December 2010 were included within analyses. There were 35 386 procedures. Cox proportional hazard models were used to analyse the extent to which the risk of revision was related to patient, surgeon and implant covariates. The overall rate of revision at five years was 2.4% (99% confidence interval 2.02 to 2.79). In the final adjusted model, we found that the risk of revision was significantly higher in patients receiving metal-on-metal (MoM: hazard ratio (HR) 1.93, p < 0.001) and ceramic-on-ceramic bearings (CoC: HR 1.55, p = 0.003) compared with the best performing bearing (metal-on-polyethylene). The risk of revision was also greater for smaller femoral stems (sizes 8 to 10: HR 1.82, p < 0.001) compared with mid-range sizes. In a secondary analysis of only patients where body mass index (BMI) data were available (n = 17 166), BMI ≥ 30 kg/m2 significantly increased the risk of revision (HR 1.55, p = 0.002). The influence of the bearing on the risk of revision remained significant (MoM: HR 2.19, p < 0.001; CoC: HR 2.09, p = 0.001). The risk of revision was independent of age, gender, head size and offset, shell, liner and stem type, and surgeon characteristics.

We found significant differences in failure between bearing surfaces and femoral stem size after adjustment for a range of covariates in a large cohort of single-brand cementless THRs. In this study of procedures performed since 2003, hard bearings had significantly higher rates of revision, but we found no evidence that head size had an effect. Patient characteristics, such as BMI and American Society of Anesthesiologists grade, also influence the survival of cementless components.

Cite this article: Bone Joint J 2013;95-B:747–57.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1393 - 1398
1 Oct 2012
Mattila M Jalanko T Puisto V Pajulo O Helenius IJ

We compared the clinical, radiological and quality-of-life outcomes between hybrid and total pedicle screw instrumentation in patients undergoing surgery for neuromuscular scoliosis. A matched comparison using prospectively collected data was undertaken. A total of 66 patients underwent posterior or anteroposterior correction and fusion with hybrid (n = 33, mean age at surgery 15.8 years (9.10 to 19.6)) or total pedicle screw instrumentation (n = 33, mean age 14.7 years (7.0 to 20.7)) with a minimum follow-up of two years. The major curve pre-operatively was a mean of 87° (sd 29, 25° to 141°) and 81° (sd 18, 47° to 116°) in the hybrid and total pedicle screw groups, respectively (p = 0.29) and at a minimum of two years it was 33° (sd 20; 2° to 87°) and 20° (sd 12; 1° to 55°), respectively (p = 0.0016). The mean correction of the major curve was 59% (41% to 88%) in the hybrid and 75% (43% to 99%) in the total pedicle screw groups at two-year follow-up (p = 0.0011). The mean operating time was 7.45 hours (sd 2.18) and 6.04 hours (sd 1.71) in the hybrid and total pedicle screw groups, respectively (p = 0.001), and the mean intra-operative blood loss was 3760 ml (sd 2790) and 1785 ml (sd 1110), respectively (p = 0.001).

Total pedicle screw instrumentation provided shorter operating times, less blood loss and better correction of the major curve compared with hybrid constructs in patients undergoing surgery for neuromuscular scoliosis.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 9 | Pages 1257 - 1263
1 Sep 2006
Richter M Droste P Goesling T Zech S Krettek C

Different calcaneal plates with locked screws were compared in an experimental model of a calcaneal fracture. Four plate models were tested, three with uniaxially-locked screws (Synthes, Newdeal, Darco), and one with polyaxially-locked screws (90° ± 15°) (Rimbus). Synthetic calcanei were osteotomised to create a fracture model and then fixed with the plates and screws. Seven specimens for each plate model were subjected to cyclic loading (preload 20 N, 1000 cycles at 800 N, 0.75 mm/s), and load to failure (0.75 mm/s).

During cyclic loading, the plate with polyaxially-locked screws (Rimbus) showed significantly lower displacement in the primary loading direction than the plates with uniaxially-locked screws (mean values of maximum displacement during cyclic loading: Rimbus, 3.13 mm (sd 0.68); Synthes, 3.46 mm (sd 1.25); Darco, 4.48 mm (sd 3.17); Newdeal, 5.02 mm (sd 3.79); one-way analysis of variance, p < 0.001).

The increased stability of a plate with polyaxially-locked screws demonstrated during cyclic loading compared with plates with uniaxially-locked screws may be beneficial for clinical use.


Bone & Joint 360
Vol. 1, Issue 4 | Pages 29 - 31
1 Aug 2012

The August 2012 Children’s orthopaedics Roundup360 looks at: whether 3D-CT gives a better idea of coverage than plain radiographs; forearm fractures after trampolining accidents; forearm fractures and the Rush pin; the fractured distal radius; elastic stable intramedullary nailing for long-bone fractures; aponeurotic recession for the equinus foot; the torn medial patellofemoral ligament and the adductor tubercle; slipped capital femoral epiphysis; paediatric wrist arthroscopy; and Pirani scores and clubfoot.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 11 | Pages 1502 - 1506
1 Nov 2005
Arora J Ogden AC

We analysed at a mean follow-up of 7.25 years the clinical and radiological outcome of 117 patients (125 knees) who had undergone a primary, cemented, modular Freeman-Samuelson total knee replacement. While the tibial and femoral components were cemented, the patellar component was uncemented. A surface-cementing technique was used to secure the tibial components. A total of 82 knees was available for radiological assessment. Radiolucent lines were seen in 41 knees (50%) and osteolytic lesions were seen in 13 knees (16%). Asymptomatic, rotational loosening of the patellar implant was seen in four patients and osteolysis was more common in patients with a patellar resurfacing. Functional outcome scores were available for 41 patients (41 knees, 35%) and the mean Western Ontario McMasters Universities score was 77.5 (sd 19.5) and the cumulative survival was 93.4% at ten years with revision for aseptic loosening as an endpoint. Increased polyethylene wear from modular components, a rotationally-loose patella, and the surface-cementing technique may have contributed to the high rate of osteolysis seen in our study.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 7 | Pages 865 - 869
1 Jul 2009
Shah NN Edge AJ Clark DW

In 2004 we described the ten-year prospective results of 38 total hip replacements using the Furlong hydroxyapatite-ceramic-coated femoral component in 35 patients < 50 years old. We have now reviewed the surviving 35 arthroplasties in 33 patients at a mean of 16 years (10.3 to 19.9). The mean age of the surviving patients at the time of operation was 41.3 years (26.0 to 49.0). Of these, eight have undergone revision of their acetabular component for aseptic loosening. None of the femoral components has had revision for aseptic loosening giving a survival rate of 100% at 16 years (95% confidence interval 89% to 100%).

The Furlong hydroxyapatite-ceramic-coated femoral component gives excellent long-term survival in young and active patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 997 - 1002
1 Aug 2006
Vendittoli P Lavigne M Girard J Roy AG

We have undertaken a prospective, randomised study to compare conservation of acetabular bone after total hip replacement and resurfacing arthroplasty of the hip. We randomly assigned 210 hips to one of the two treatment groups. Uncemented, press-fit acetabular components were used for both.

No significant difference was found in the mean diameter of acetabular implant inserted in the groups (54.74 mm for total hip replacement and 54.90 mm for resurfacing arthroplasty). In seven resurfacing procedures (6.8%), the surgeon used a larger size of component in order to match the corresponding diameter of the femoral component.

With resurfacing arthroplasty, conservation of bone is clearly advantageous on the femoral side. Our study has shown that, with a specific design of acetabular implant and by following a careful surgical technique, removal of bone on the acetabular side is comparable with that of total hip replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1101 - 1106
1 Aug 2012
Jindal N Sankhala SS Bachhal V

The purpose of this study was to determine whether patients with a burst fracture of the thoracolumbar spine treated by short segment pedicle screw fixation fared better clinically and radiologically if the affected segment was fused at the same time. A total of 50 patients were enrolled in a prospective study and assigned to one of two groups. After the exclusion of three patients, there were 23 patients in the fusion group and 24 in the non-fusion group. Follow-up was at a mean of 23.9 months (18 to 30). Functional outcome was evaluated using the Greenough Low Back Outcome Score. Neurological function was graded using the American Spinal Injury Association Impairment Scale. Radiological outcome was assessed on the basis of the angle of kyphosis.

Peri-operative blood transfusion requirements and duration of surgery were significantly higher in the fusion group (p = 0.029 and p < 0.001, respectively). There were no clinical or radiological differences in outcome between the groups (all outcomes p > 0.05). The results of this study suggest that adjunctive fusion is unnecessary when managing patients with a burst fracture of the thoracolumbar spine with short segment pedicle screw fixation.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 12 | Pages 1670 - 1677
1 Dec 2012
Tsirikos AI Subramanian AS

We reviewed 212 consecutive patients with adolescent idiopathic scoliosis who underwent posterior spinal arthrodesis using all pedicle screw instrumentation in terms of clinical, radiological and Scoliosis Research Society (SRS)-22 outcomes. In Group 1 (51 patients), the correction was performed over two rods using bilateral segmental pedicle screws. In Group 2 (161 patients), the correction was performed over one rod using unilateral segmental pedicle screws with the second rod providing stability of the construct through two-level screw fixation at proximal and distal ends. The mean age at surgery was 14.8 years in both groups. Comparison between groups showed no significant differences with regard to age and Risser grade at surgery, pre- and post-operative scoliosis angle, coronal Cobb correction, length of hospital stay and SRS scores. Correction of upper thoracic curves was significantly better in Group 1 (p = 0.02). Increased surgical time and intra-operative blood loss was recorded in Group 1 (p < 0.001 and p = 0.04, respectively). The implant cost was reduced by mean 35% in Group 2 due to the lesser number of pedicle screws.

Unilateral and bilateral pedicle screw techniques have both achieved excellent deformity correction in adolescent patients with idiopathic scoliosis, which was maintained at two-year follow-up. This has been associated with high patient satisfaction and low complication rates.


Bone & Joint 360
Vol. 1, Issue 1 | Pages 18 - 19
1 Feb 2012