The aim of this study was to identify any progression between
benign osteofibrous dysplasia (OFD), OFD-like adamantinoma and malignant
adamantinoma, and to investigate the rates of local recurrence,
metastases and survival, in order to develop treatment algorithms
for each. A single institution retrospective review of all patients presenting
with OFD, OFD-like adamantinoma and adamantinoma between 1973 and
2012 was undertaken. Complete data were available for 73 patients
(42 with OFD; ten with an OFD-like adamantinoma and 21 with an adamantinoma).
The mean follow-up was 10.3 years (3 to 25) for OFD, 9.2 years (3.0
to 26.3) for OFD-like and 11.6 years (0.25 to 33) for adamantinoma.Aims
Patients and Methods
Periprosthetic fracture (PF) after primary total hip arthroplasty
(THA) is an uncommon but potentially devastating complication. This
study aims to investigate the influence of cemented stem designs
on the risk of needing a revision for a PF. We analysed data on 257 202 primary THAs with cemented stems
and 390 linked first revisions for PF recorded in the National Joint
Registry (NJR) of England, Wales and Northern Ireland to determine
if a cemented femoral stem brand was associated with the risk of
having revision for a PF after primary THA. All cemented femoral
stem brands with more than 10 000 primary operations recorded in
the NJR were identified. The four most commonly used cemented femoral
stems were the Exeter V40 (n = 146 409), CPT (n = 24 300), C-Stem
(n = 15 113) and Charnley (n = 20 182). We compared the revision risk ratios due to PF amongst the stems
using a Poisson regression model adjusting for patient factors.
Compared with the Exeter V40, the age, gender and ASA grade adjusted
revision rate ratio was 3.89 for the cemented CPT stem (95% confidence
interval (CI) 3.07 to 4.93), 0.89 for the C-Stem (95% CI 0.57 to
1.41) and 0.41 for the Charnley stem (95% CI 0.24 to 0.70).Aims
Patients and Methods
Chronic osteomyelitis may recur if dead space management, after
excision of infected bone, is inadequate. This study describes the
results of a strategy for the management of deep bone infection
and evaluates a new antibiotic-loaded biocomposite in the eradication
of infection from bone defects. We report a prospective study of 100 patients with chronic osteomyelitis,
in 105 bones. Osteomyelitis followed injury or surgery in 81 patients.
Nine had concomitant septic arthritis. 80 patients had comorbidities
(Cierny-Mader (C-M) Class B hosts). Ten had infected nonunions. All patients were treated by a multidisciplinary team with a
single-stage protocol including debridement, multiple sampling,
culture-specific systemic antibiotics, stabilisation, dead space
filling with the biocomposite and primary skin closure. Aims
Patients and Methods
The goal of this study is to investigate the relation between indicators of osteoporosis (i.e., bone mineral density (BMD), and Cortical Index (CI)) and the complexity of a fracture of the proximal humerus as a result of a low-energy trauma. A retrospective chart review of 168 patients (mean age 67.2 years, range 51 to 88.7) with a fracture of the proximal humerus between 2007 and 2011, whose BMD was assessed at the Fracture Liaison Service with Dual Energy X-ray Absorptiometry (DXA) measurements of the hip, femoral neck (FN) and/or lumbar spine (LS), and whose CI and complexity of fracture were assessed on plain anteroposterior radiographs of the proximal humerus.Objectives
Methods
Little biomechanical information is available about kinematically aligned (KA) total knee arthroplasty (TKA). The purpose of this study was to simulate the kinematics and kinetics after KA TKA and mechanically aligned (MA) TKA with four different limb alignments. Bone models were constructed from one volunteer (normal) and three patients with three different knee deformities (slight, moderate and severe varus). A dynamic musculoskeletal modelling system was used to analyse the kinematics and the tibiofemoral contact force. The contact stress on the tibial insert, and the stress to the resection surface and medial tibial cortex were examined by using finite element analysis.Objectives
Materials and Methods
This retrospective study was designed to evaluate
the outcomes of re-dislocation of the radial head after corrective osteotomy
for chronic dislocation. A total of 12 children with a mean age
of 11 years (5 to 16), with further dislocation of the radial head
after corrective osteotomy of the forearm, were followed for a mean
of five years (2 to 10). Re-operations were performed for radial
head re-dislocation in six children, while the other six did not
undergo re-operation (‘non-re-operation group’). The active range
of movement (ROM) of their elbows was evaluated before and after
the first operation, and at the most recent follow-up. In the re-operation group, there were significant decreases in
extension, pronation, and supination when comparing the ROM following
the corrective osteotomy and following
re-operation (p <
0.05). The children who had not undergone re-operation achieved a better
ROM than those who had undergone re-operation. There was a significant difference in mean pronation (76° Cite this article:
This paper describes the methodology, validation and reliability
of a new computer-assisted method which uses models of the patient’s
bones and the components to measure their migration and polyethylene
wear from radiographs after total hip arthroplasty (THA). Models of the patient’s acetabular and femoral component obtained
from the manufacturer and models of the patient’s pelvis and femur
built from a single computed tomography (CT) scan, are used by a
computer program to measure the migration of the components and
the penetration of the femoral head from anteroposterior and lateral radiographs
taken at follow-up visits. The program simulates the radiographic
setup and matches the position and orientation of the models to
outlines of the pelvis, the acetabular and femoral component, and
femur on radiographs. Changes in position and orientation reflect
the migration of the components and the penetration of the femoral
head. Validation was performed using radiographs of phantoms simulating
known migration and penetration, and the clinical feasibility of
measuring migration was assessed in two patients.Aims
Materials and Methods
There is no consensus on the benefit of arthroscopically
assisted reduction of the articular surface combined with fixation
using a volar locking plate for the treatment of intra-articular
distal radial fractures. In this study we compared the functional
and radiographic outcomes of fluoroscopically and arthroscopically
guided reduction of these fractures. Between February 2009 and May 2013, 74 patients with unilateral
unstable intra-articular distal radial fractures were randomised
equally into the two groups for treatment. The mean age of these
74 patients was 64 years (24 to 92). We compared functional outcomes
including active range of movement of the wrist, grip strength and Disabilities
of the Arm, Shoulder, and Hand scores at six and 48 weeks; and radiographic
outcomes that included gap, step, radial inclination, volar angulation
and ulnar variance. There were no significant differences between the techniques
with regard to functional outcomes or radiographic parameters. The
mean gap and step in the fluoroscopic and arthroscopic groups were
comparable at 0.9 mm (standard deviation Arthroscopic reduction conferred no advantage over conventional
fluoroscopic guidance in achieving anatomical reduction of intra-articular
distal radial fractures when using a volar locking plate. Cite this article:
Throughout the 20th Century, it has been postulated that the knee moves on the basis of a four-bar link mechanism composed of the cruciate ligaments, the femur and the tibia. As a consequence, the femur has been thought to roll back with flexion, and total knee arthroplasty (TKA) prostheses have been designed on this basis. Recent work, however, has proposed that at a position of between 0° and 120° the medial femoral condyle does not move anteroposteriorly whereas the lateral femoral condyle tends, but is not obliged, to roll back – a combination of movements which equates to tibial internal/ femoral external rotation with flexion. The aim of this paper was to assess if the articular geometry of the GMK Sphere TKA could recreate the natural knee movements The pattern of knee movement was studied in 15 patients (six male: nine female; one male with bilateral TKAs) with 16 GMK Sphere implants, at a mean age of 66 years (53 to 76) with a mean BMI of 30 kg/m2 (20 to 35). The motions of all 16 knees were observed using pulsed fluoroscopy during a number of weight-bearing and non-weight-bearing static and dynamic activities.Objectives
Methods
Arthritis of the wrist is a painful disabling
condition that has various causes and presentations. The traditional treatment
has been a total wrist fusion at a price of the elimination of movement.
However, forms of treatment which allow the preservation of movement
are now preferred. Modern arthroplasties of the wrist are still
not sufficiently robust to meet the demands of many patients, nor
do they restore normal kinematics of the wrist. A preferable compromise
may be selective excision and partial fusion of the wrist using
knowledge of the aetiology and pattern of degenerative change to
identify which joints can be sacrificed and which can be preserved. This article provides an overview of the treatment options available
for patients with arthritis of the wrist and an algorithm for selecting
an appropriate surgical strategy. Cite this article:
To explore whether orthopaedic surgeons have adopted the Proximal Fracture of the Humerus: Evaluation by Randomisation (PROFHER) trial results routinely into clinical practice. A questionnaire was piloted with six orthopaedic surgeons using a ‘think aloud’ process. The final questionnaire contained 29 items and was distributed online to surgeon members of the British Orthopaedic Association and British Elbow and Shoulder Society. Descriptive statistics summarised the sample characteristics and fracture treatment of respondents overall, and grouped them by whether they changed practice based on PROFHER trial findings. Free-text responses were analysed qualitatively for emerging themes using Framework Analysis principles.Objectives
Methods
Total wrist arthrodesis (TWA) produces a spectrum of outcomes.
We investigated this by reviewing 77 consecutive TWA performed for
inflammatory and post-traumatic arthropathies, wrist instability
and as a salvage procedure. All operations were performed by a single surgeon using a specifically
designed pre-contoured dorsally applied non-locking wrist arthrodesis
plate at a single centre. Aims
Patients and Methods
A contact patch to rim (CPR) distance of <
10 mm has been
associated with edge-loading and excessive wear. However, not all
arthroplasties with a low CPR distance show problems with wear.
Therefore, CPR distance may not be the only variable affecting the
post-operative metal ion concentrations. We used multiple logistic regression to determine what variables
differed between the patients who had high and low cobalt (CoS)
and chromium (CrS) serum ion concentrations within a cohort of patients
with low (<
10 mm) CPR distances. A total of 56 patients treated
with unilateral hip resurfacing arthroplasty (HRA) had CoS and CrS
ion studies performed more than one year after surgery. The mean
age of the patients at the time of surgery was 51.7 years (29 to
70), with 38 women (68%) and 18 men (32%).Aims
Patients and Methods