Advertisement for orthosearch.org.uk
Results 541 - 560 of 1910
Results per page:
The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1731 - 1735
1 Nov 2021
Iobst CA Frost MW Rölfing JD Rahbek O Bafor A Duncan M Kold S

Aims

Limb-lengthening nails have largely replaced external fixation in limb-lengthening and reconstructive surgery. However, the adverse events and high prevalence of radiological changes recently noted with the STRYDE lengthening nail have raised concerns about the use of internal lengthening nails. The aim of this study was to compare the prevalence of radiological bone abnormalities between STRYDE, PRECICE, and FITBONE nails prior to nail removal.

Methods

This was a retrospective case series from three centres. Patients were included if they had either of the three limb-lengthening nails (STYDE, PRECICE, or FITBONE) removed. Standard orthogonal radiographs immediately prior to nail removal were examined for bone abnormalities at the junction of the telescoping nail parts.


The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 376 - 385
1 Mar 2022
Gramlich Y Hofmann L Kress S Ruckes C Kemmerer M Klug A Hoffmann R Kremer M

Aims

This study compared the cobalt and chromium serum ion concentration of patients treated with two different metal-on-metal (MoM) hinged total knee arthroplasty (TKA) systems, as well as a titanium nitride (TiN)-coated variant.

Methods

A total of 63 patients (65 implants) were treated using either a MoM-coated (n = 29) or TiN-coated (n = 7) hinged TKA (GenuX mobile bearing, MUTARS; Implantcast, Germany) versus the BPKS (Brehm, Germany) hinged TKA (n = 27), in which the weight placed on the MoM hinge is diffused through a polyethylene (PE) inlay, reducing the direct load on the MoM hinge. Serum cobalt and chromium ion concentrations were assessed after minimum follow-up of 12 months, as well as functional outcome and quality of life.


Bone & Joint Research
Vol. 10, Issue 12 | Pages 820 - 829
15 Dec 2021
Schmidutz F Schopf C Yan SG Ahrend M Ihle C Sprecher C

Aims

The distal radius is a major site of osteoporotic bone loss resulting in a high risk of fragility fracture. This study evaluated the capability of a cortical index (CI) at the distal radius to predict the local bone mineral density (BMD).

Methods

A total of 54 human cadaver forearms (ten singles, 22 pairs) (19 to 90 years) were systematically assessed by clinical radiograph (XR), dual-energy X-ray absorptiometry (DXA), CT, as well as high-resolution peripheral quantitative CT (HR-pQCT). Cortical bone thickness (CBT) of the distal radius was measured on XR and CT scans, and two cortical indices mean average (CBTavg) and gauge (CBTg) were determined. These cortical indices were compared to the BMD of the distal radius determined by DXA (areal BMD (aBMD)) and HR-pQCT (volumetric BMD (vBMD)). Pearson correlation coefficient (r) and intraclass correlation coefficient (ICC) were used to compare the results and degree of reliability.


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 297 - 301
1 Feb 2022
Jamshidi K Bagherifard A Mohaghegh MR Mirzaei A

Aims

Giant cell tumours (GCTs) of the proximal femur are rare, and there is no consensus about the best method of filling the defect left by curettage. In this study, we compared the outcome of using a fibular strut allograft and bone cement to reconstruct the bone defect after extended curettage of a GCT of the proximal femur.

Methods

In a retrospective study, we reviewed 26 patients with a GCT of the proximal femur in whom the bone defect had been filled with either a fibular strut allograft (n = 12) or bone cement (n = 14). Their demographic details and oncological and nononcological complications were retrieved from their medical records. Limb function was assessed using the Musculoskeletal Tumor Society (MSTS) score.


Bone & Joint 360
Vol. 11, Issue 1 | Pages 43 - 46
1 Feb 2022


Bone & Joint Research
Vol. 6, Issue 8 | Pages 522 - 529
1 Aug 2017
Ali AM Newman SDS Hooper PA Davies CM Cobb JP

Objectives. Unicompartmental knee arthroplasty (UKA) is a demanding procedure, with tibial component subsidence or pain from high tibial strain being potential causes of revision. The optimal position in terms of load transfer has not been documented for lateral UKA. Our aim was to determine the effect of tibial component position on proximal tibial strain. Methods. A total of 16 composite tibias were implanted with an Oxford Domed Lateral Partial Knee implant using cutting guides to define tibial slope and resection depth. Four implant positions were assessed: standard (5° posterior slope); 10° posterior slope; 5° reverse tibial slope; and 4 mm increased tibial resection. Using an electrodynamic axial-torsional materials testing machine (Instron 5565), a compressive load of 1.5 kN was applied at 60 N/s on a meniscal bearing via a matching femoral component. Tibial strain beneath the implant was measured using a calibrated Digital Image Correlation system. Results. A 5° increase in tibial component posterior slope resulted in a 53% increase in mean major principal strain in the posterior tibial zone adjacent to the implant (p = 0.003). The highest strains for all implant positions were recorded in the anterior cortex 2 cm to 3 cm distal to the implant. Posteriorly, strain tended to decrease with increasing distance from the implant. Lateral cortical strain showed no significant relationship with implant position. Conclusion. Relatively small changes in implant position and orientation may significantly affect tibial cortical strain. Avoidance of excessive posterior tibial slope may be advisable during lateral UKA. Cite this article: A. M. Ali, S. D. S. Newman, P. A. Hooper, C. M. Davies, J. P. Cobb. The effect of implant position on bone strain following lateral unicompartmental knee arthroplasty: A Biomechanical Model Using Digital Image Correlation. Bone Joint Res 2017;6:522–529. DOI: 10.1302/2046-3758.68.BJR-2017-0067.R1


The Bone & Joint Journal
Vol. 103-B, Issue 12 | Pages 1791 - 1801
1 Dec 2021
Bhalekar RM Nargol ME Shyam N Nargol AVF Wells SR Collier R Pabbruwe M Joyce TJ Langton DJ

Aims

The aim of this study was to investigate whether wear and backside deformation of polyethylene (PE) tibial inserts may influence the cement cover of tibial trays of explanted total knee arthroplasties (TKAs).

Methods

At our retrieval centre, we measured changes in the wear and deformation of PE inserts using coordinate measuring machines and light microscopy. The amount of cement cover on the backside of tibial trays was quantified as a percentage of the total surface. The study involved data from the explanted fixed-bearing components of four widely used contemporary designs of TKA (Attune, NexGen, Press Fit Condylar (PFC), and Triathlon), revised for any indication, and we compared them with components that used previous generations of PE. Regression modelling was used to identify variables related to the amount of cement cover on the retrieved trays.


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1561 - 1570
1 Oct 2021
Blyth MJG Banger MS Doonan J Jones BG MacLean AD Rowe PJ

Aims

The aim of this study was to compare the clinical outcomes of robotic arm-assisted bi-unicompartmental knee arthroplasty (bi-UKA) with conventional mechanically aligned total knee arthroplasty (TKA) during the first six weeks and at one year postoperatively.

Methods

A per protocol analysis of 76 patients, 43 of whom underwent TKA and 34 of whom underwent bi-UKA, was performed from a prospective, single-centre, randomized controlled trial. Diaries kept by the patients recorded pain, function, and the use of analgesics daily throughout the first week and weekly between the second and sixth weeks. Patient-reported outcome measures (PROMs) were compared preoperatively, and at three months and one year postoperatively. Data were also compared longitudinally and a subgroup analysis was conducted, stratified by preoperative PROM status.


Bone & Joint Open
Vol. 3, Issue 1 | Pages 98 - 106
27 Jan 2022
Gelfer Y Leo DG Russell A Bridgens A Perry DC Eastwood DM

Aims

To identify the minimum set of outcomes that should be collected in clinical practice and reported in research related to the care of children with idiopathic congenital talipes equinovarus (CTEV).

Methods

A list of outcome measurement tools (OMTs) was obtained from the literature through a systematic review. Further outcomes were collected from patients and families through a questionnaire and interview process. The combined list, as well as the appropriate follow-up timepoint, was rated for importance in a two-round Delphi process that included an international group of orthopaedic surgeons, physiotherapists, nurse practitioners, patients, and families. Outcomes that reached no consensus during the Delphi process were further discussed and scored for inclusion/exclusion in a final consensus meeting involving international stakeholder representatives of practitioners, families, and patient charities.


Bone & Joint 360
Vol. 10, Issue 5 | Pages 40 - 43
1 Oct 2021


Bone & Joint Open
Vol. 2, Issue 8 | Pages 599 - 610
1 Aug 2021
Hothi H Bergiers S Henckel J Iliadis AD Goodier WD Wright J Skinner J Calder P Hart AJ

Aims

The aim of this study was to present the first retrieval analysis findings of PRECICE STRYDE intermedullary nails removed from patients, providing useful information in the post-market surveillance of these recently introduced devices.

Methods

We collected ten nails removed from six patients, together with patient clinical data and plain radiograph imaging. We performed macro- and microscopic analysis of all surfaces and graded the presence of corrosion using validated semiquantitative scoring methods. We determined the elemental composition of surface debris using energy dispersive x-ray spectroscopy (EDS) and used metrology analysis to characterize the surface adjacent to the extendable junctions.


The Bone & Joint Journal
Vol. 99-B, Issue 3 | Pages 358 - 364
1 Mar 2017
Torkington MS Davison MJ Wheelwright EF Jenkins PJ Anthony I Lovering AM Blyth M Jones B

Aims. To investigate the bone penetration of intravenous antibiotic prophylaxis with flucloxacillin and gentamicin during hip and knee arthroplasty, and their efficacy against Staphylococcus (S.) aureus and S. epidermidis. Patients and Methods. Bone samples from the femoral head, neck and acetabulum were collected from 18 patients undergoing total hip arthroplasty (THA) and from the femur and tibia in 21 patients during total knee arthroplasty (TKA). The concentration of both antibiotics in the samples was analysed using high performance liquid chromatography. Penetration was expressed as a percentage of venous blood concentration. The efficacy against common infecting organisms was measured against both the minimum inhibitory concentration 50, and the more stringent epidemiological cutoff value for resistance (ECOFF). Results. The bone penetration of gentamicin was higher than flucloxacillin. Relative to ECOFF, flucloxacillin concentrations were effective against S. aureus and S. epidermidis in all THAs and 20 (95%) TKAs. Gentamicin concentrations were effective against S. epidermidis in all bone samples. Gentamicin was effective against S. aureus in 11 (61.1%) femoral neck samples in THA. Effective concentrations of gentamicin against S. aureus were only achieved in four (19%) femoral and six (29%) tibial samples in TKA. Conclusion. Flucloxacillin and gentamicin were found to penetrate bone during THA and TKA. Gentamicin was effective against S. epidermidis in both THA and TKA, while levels were subtherapeutic against S. aureus in most TKAs. Bone penetration of both antibiotics was less in TKA than THA, and may relate to the use of a tourniquet. Using this antibiotic combination, effective cover against the two common infective organisms was achieved in all THAs and all but one TKA. Cite this article: Bone Joint J 2017;99-B:358–64


Bone & Joint Open
Vol. 2, Issue 7 | Pages 503 - 508
8 Jul 2021
Callaghan CJ McKinley JC

Aims

Arthroplasty has become increasingly popular to treat end-stage ankle arthritis. Iatrogenic posterior neurovascular and tendinous injury have been described from saw cuts. However, it is hypothesized that posterior ankle structures could be damaged by inserting tibial guide pins too deeply and be a potential cause of residual hindfoot pain.

Methods

The preparation steps for ankle arthroplasty were performed using the Infinity total ankle system in five right-sided cadaveric ankles. All tibial guide pins were intentionally inserted past the posterior tibial cortex for assessment. All posterior ankles were subsequently dissected, with the primary endpoint being the presence of direct contact between the structure and pin.


The Bone & Joint Journal
Vol. 99-B, Issue 12 | Pages 1689 - 1695
1 Dec 2017
Stevenson JD Wigley C Burton H Ghezelayagh S Morris G Evans S Parry M Jeys L

Aims. Following the resection of an extensive amount of bone in the treatment of a tumour, the residual segment may be insufficient to accept a standard length intramedullary cemented stem. Short-stemmed endoprostheses conceivably have an increased risk of aseptic loosening. Extra-cortical plates have been added to minimise this risk by supplementing fixation. The aim of this study was to investigate the survivorship of short-stemmed endoprostheses and extra-cortical plates. Patients and Methods. The study involved 37 patients who underwent limb salvage surgery for a primary neoplasm of bone between 1998 and 2013. Endoprosthetic replacement involved the proximal humerus in nine, the proximal femur in nine, the distal femur in 13 and the proximal tibia in six patients. There were 12 primary (32%) and 25 revision procedures (68%). Implant survivorship was compared with matched controls. The amount of bone that was resected was > 70% of its length and statistically greater than the standard control group at each anatomical site. Results. The mean follow-up was seven years (one to 17). The mean length of the stem was 33 mm (20 to 60) in the humerus and 79 mm (34 to 100) in the lower limb. Kaplan-Meier analysis of survival of the implant according to anatomical site confirmed that there was no statistically significant difference between the short-stemmed endoprostheses and the standard stemmed controls at the proximal humeral (p = 0.84), proximal femoral (p = 0.57), distal femoral (p = 0.21) and proximal tibial (p = 0.61) sites. In the short-stemmed group, no implants with extra-cortical plate osseointegration suffered loosening at a mean of 8.5 years (range 2 to 16 years). Three of ten (30%) without osseointegration suffered aseptic loosening at a mean of 7.7 years (range 2 to 11.5 years). Conclusion. When extensive resections of bone are required in the surgical management of tumours, and in revision cases, the addition of extra-cortical plates to short medullary stems has shown non-inferiority to standard length medullary stems and minimises aseptic failure. Cite this article: Bone Joint J 2017;99-B:1689–95


Bone & Joint Research
Vol. 6, Issue 4 | Pages 216 - 223
1 Apr 2017
Ang BFH Chen JY Yew AKS Chua SK Chou SM Chia SL Koh JSB Howe TS

Objectives. External fixators are the traditional fixation method of choice for contaminated open fractures. However, patient acceptance is low due to the high profile and therefore physical burden of the constructs. An externalised locking compression plate is a low profile alternative. However, the biomechanical differences have not been assessed. The objective of this study was to evaluate the axial and torsional stiffness of the externalised titanium locking compression plate (ET-LCP), the externalised stainless steel locking compression plate (ESS-LCP) and the unilateral external fixator (UEF). Methods. A fracture gap model was created to simulate comminuted mid-shaft tibia fractures using synthetic composite bones. Fifteen constructs were stabilised with ET-LCP, ESS-LCP or UEF (five constructs each). The constructs were loaded under both axial and torsional directions to determine construct stiffness. Results. The mean axial stiffness was very similar for UEF (528 N/mm) and ESS-LCP (525 N/mm), while it was slightly lower for ET-LCP (469 N/mm). One-way analysis of variance (ANOVA) testing in all three groups demonstrated no significant difference (F(2,12) = 2.057, p = 0.171). There was a significant difference in mean torsional stiffness between the UEF (0.512 Nm/degree), the ESS-LCP (0.686 Nm/degree) and the ET-LCP (0.639 Nm/degree), as determined by one-way ANOVA (F(2,12) = 6.204, p = 0.014). A Tukey post hoc test revealed that the torsional stiffness of the ESS-LCP was statistically higher than that of the UEF by 0.174 Nm/degree (p = 0.013). No catastrophic failures were observed. Conclusion. Using the LCP as an external fixator may provide a viable and attractive alternative to the traditional UEF as its lower profile makes it more acceptable to patients, while not compromising on axial and torsional stiffness. Cite this article: B. F. H. Ang, J. Y. Chen, A. K. S. Yew, S. K. Chua, S. M. Chou, S. L. Chia, J. S. B. Koh, T. S. Howe. Externalised locking compression plate as an alternative to the unilateral external fixator: a biomechanical comparative study of axial and torsional stiffness. Bone Joint Res 2017;6:216–223. DOI: 10.1302/2046-3758.64.2000470


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 6 | Pages 830 - 834
1 Jun 2009
Pinskerova V Samuelson KM Stammers J Maruthainar K Sosna A Freeman MAR

There has been only one limited report dating from 1941 using dissection which has described the tibiofemoral joint between 120° and 160° of flexion despite the relevance of this arc to total knee replacement. We now provide a full description having examined one living and eight cadaver knees using MRI, dissection and previously published cryosections in one knee. In the range of flexion from 120° to 160° the flexion facet centre of the medial femoral condyle moves back 5 mm and rises up on to the posterior horn of the medial meniscus. At 160° the posterior horn is compressed in a synovial recess between the femoral cortex and the tibia. This limits flexion. The lateral femoral condyle also rolls back with the posterior horn of the lateral meniscus moving with the condyle. Both move down over the posterior tibia at 160° of flexion. Neither the events between 120° and 160° nor the anatomy at 160° could result from a continuation of the kinematics up to 120°. Therefore hyperflexion is a separate arc. The anatomical and functional features of this arc suggest that it would be difficult to design an implant for total knee replacement giving physiological movement from 0° to 160°


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 103 - 111
1 Jan 2022
Li J Hu Z Qian Z Tang Z Qiu Y Zhu Z Liu Z

Aims

The outcome following the development of neurological complications after corrective surgery for scoliosis varies from full recovery to a permanent deficit. This study aimed to assess the prognosis and recovery of major neurological deficits in these patients, and to determine the risk factors for non-recovery, at a minimum follow-up of two years.

Methods

A major neurological deficit was identified in 65 of 8,870 patients who underwent corrective surgery for scoliosis, including eight with complete paraplegia and 57 with incomplete paraplegia. There were 23 male and 42 female patients. Their mean age was 25.0 years (SD 16.3). The aetiology of the scoliosis was idiopathic (n = 6), congenital (n = 23), neuromuscular (n = 11), neurofibromatosis type 1 (n = 6), and others (n = 19). Neurological function was determined by the American Spinal Injury Association (ASIA) impairment scale at a mean follow-up of 45.4 months (SD 17.2). the patients were divided into those with recovery and those with no recovery according to the ASIA scale during follow-up.


Bone & Joint Research
Vol. 10, Issue 7 | Pages 425 - 436
16 Jul 2021
Frommer A Roedl R Gosheger G Hasselmann J Fuest C Toporowski G Laufer A Tretow H Schulze M Vogt B

Aims

This study aims to enhance understanding of clinical and radiological consequences and involved mechanisms that led to corrosion of the Precice Stryde (Stryde) intramedullary lengthening nail in the post market surveillance era of the device. Between 2018 and 2021 more than 2,000 Stryde nails have been implanted worldwide. However, the outcome of treatment with the Stryde system is insufficiently reported.

Methods

This is a retrospective single-centre study analyzing outcome of 57 consecutive lengthening procedures performed with the Stryde nail at the authors’ institution from February 2019 until November 2020. Macro- and microscopic metallographic analysis of four retrieved nails was conducted. To investigate observed corrosion at telescoping junction, scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDX) were performed.


Bone & Joint Open
Vol. 2, Issue 10 | Pages 825 - 833
8 Oct 2021
Dailey HL Schwarzenberg P Webb, III EB Boran SAM Guerin S Harty JA

Aims

The study objective was to prospectively assess clinical outcomes for a pilot cohort of tibial shaft fractures treated with a new tibial nailing system that produces controlled axial interfragmentary micromotion. The hypothesis was that axial micromotion enhances fracture healing compared to static interlocking.

Methods

Patients were treated in a single level I trauma centre over a 2.5-year period. Group allocation was not randomized; both the micromotion nail and standard-of-care static locking nails (control group) were commercially available and selected at the discretion of the treating surgeons. Injury risk levels were quantified using the Nonunion Risk Determination (NURD) score. Radiological healing was assessed until 24 weeks or clinical union. Low-dose CT scans were acquired at 12 weeks and virtual mechanical testing was performed to objectively assess structural bone healing.


The Bone & Joint Journal
Vol. 98-B, Issue 9 | Pages 1276 - 1282
1 Sep 2016
Donnan LT Gomes B Donnan A Harris C Torode† I Heidt C

Aims. We wished to examine the effectiveness of tibial lengthening using a two ring Ilizarov frame in skeletally immature patients. This is a potentially biomechanically unstable construct which risks the loss of axial control. Patients and Methods. We retrospectively reviewed a consecutive series of 24 boys and 26 girls, with a mean age of 8.6 years (4 to 14), who underwent 52 tibial lengthening procedures with a mean follow-up of 4.3 years (4.0 to 16.9). Tibial alignment was measured before and after treatment using joint orientation lines from the knee and a calculation of the oblique plane axis. Results. The mean percentage length gain was 20% (13 to 31) with a mean bone-healing index (BHI) of 34 days per centimetre (20 to 54). Age at surgery and location of the osteotomy site showed a strong relationship as the location of the osteotomy migrated more proximally with age. However, no significant correlation was found between BHI and the position of the osteotomy. The coronal and sagittal joint orientation of the lengthened tibias were within the normal range in 67% and 92% of cases, respectively. The oblique plane angulation calculation revealed a statistically significant change pre- to post-operatively in both magnitude (p < 0.05) and direction (p < 0.01), but without clinical consequence. The majority of complications were minor (n = 40 in 27 patients; 1.48 complications per segment lengthened) with no residual disability reported. Conclusion. Two-ring tibial lengthening is effective in maintaining segmental alignment, efficient in callous production and relatively comfortable for the patient with few significant complications. Cite this article: Bone Joint J 2016;98-B:1276–82