Advertisement for orthosearch.org.uk
Results 541 - 560 of 2190
Results per page:
Bone & Joint 360
Vol. 9, Issue 5 | Pages 32 - 35
1 Oct 2020


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 500 - 506
1 Mar 2021
Leonard HJ Ohly NE

Aims

The purpose of this study was to compare the clinical, radiological, and patient-reported outcome measures (PROMs) in the first 100 consecutive patients undergoing total hip arthroplasty (THA) via a direct superior approach (DSA) with a matched group of patients undergoing THA by the same surgeon, using a posterolateral approach (PLA).

Methods

This was a retrospective single surgeon study comparing the first 100 consecutive DSA THA patients with a matched group of patients using a standard PLA. Case notes were examined for patient demographics, length of hospital stay, operating time, intra- and postoperative complications, pain score, satisfaction score, and Oxford Hip Score (OHS). Leg length discrepancy and component positioning were measured from postoperative plain radiographs.


The Bone & Joint Journal
Vol. 98-B, Issue 4 | Pages 504 - 511
1 Apr 2016
Ajami S Blunn GW Lambert S Alexander S Foxall Smith M Coathup MJ

Aims. To assess the extent of osteointegration in two designs of shoulder resurfacing implants. Bony integration to the Copeland cylindrical central stem design and the Epoca RH conical-crown design were compared. Patients and Methods. Implants retrieved from six patients in each group were pair-matched. Mean time to revision surgery of Copeland implants was 37 months (standard deviation (. sd. ) 23; 14 to 72) and Epoca RH 38 months (. sd. 28; 12 to 84). The mean age of patients investigated was 66 years (. sd. 4; 59 to 71) and 58 years (. sd. 17; 31 to 73) in the Copeland and Epoca RH groups respectively. None of these implants were revised for loosening. . Results. Increased osteointegration was measured under the cup in the Copeland implant group with limited bone seen in direct contact with the central stem. Bone adjacent to the Epoca RH implants was more uniform. . Conclusion. This difference in the distribution of bone-implant contact and bone formation was attributed to the Epoca implant’s conical crown, which is positioned in more dense peripheral bone. The use of a central stem may not be necessary provided there is adequate peripheral fixation within good quality humeral bone. Take home message: Poor osteointegration of cementless surface replacement shoulder prosthesis may be improved by implant design. Cite this article: Bone Joint J 2016;98-B:504–11


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1704 - 1709
1 Dec 2015
Drexler M Gortzak Y Sternheim A Kollender Y Amar E Bickels J

Excision of the proximal femur for tumour with prosthetic reconstruction using a bipolar femoral head places a considerable load on the unreplaced acetabulum. . We retrospectively reviewed the changes which occur around the affected hip joint by evaluating the post-operative radiographs of 65 consecutive patients who underwent proximal prosthetic arthroplasty of the femur, and in whom an acetabular component had not been used. There were 37 men and 28 women with a mean age of 57.3 years (17 to 93). Radiological assessment included the extent of degenerative change in the acetabulum, heterotopic ossification, and protrusio acetabuli. . The mean follow-up was 9.1 years (2 to 11.8). Degenerative changes in the acetabulum were seen in three patients (4.6%), Brooker grade 1 or 2 heterotopic ossification in 17 (26%) and protrusion of the prosthetic head in nine (13.8%). . A total of eight patients (12.3%) needed a revision. Five were revised to the same type of prosthesis and three (4.6%) were converted to a total hip arthroplasty. . We conclude that radiological evidence of degenerative change, heterotopic ossification and protrusion occur in a few patients who undergo prosthetic arthroplasty of the proximal femur for tumour. The limited extent of these changes and the lack of associated symptoms do not justify the routine arthroplasty of the acetabulum in these patients. . Cite this article: Bone Joint J 2015;97-B:1704–9


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1662 - 1667
1 Dec 2015
Weber-Spickschen TS Alfke D Agneskirchner JD

If a modular convertible total shoulder system is used as a primary implant for an anatomical total shoulder arthroplasty, failure of the prosthesis or the rotator cuff can be addressed by converting it to a reverse shoulder arthroplasty (RSA), with retention of the humeral stem and glenoid baseplate. This has the potential to reduce morbidity and improve the results. . In a retrospective study of 14 patients (15 shoulders) with a mean age of 70 years (47 to 83) we reviewed the clinical and radiological outcome of converting an anatomical shoulder arthroplasty (ASA) to a RSA using a convertible prosthetic system (SMR system, Lima, San Daniele, Italy). . The mean operating time was 64 minutes (45 to 75). All humeral stems and glenoid baseplates were found to be well-fixed and could be retained. There were no intra-operative or early post-operative complications and no post-operative infection. The mean follow-up was 43 months (21 to 83), by which time the mean visual analogue scale for pain had decreased from 8 pre-operatively to 1, the mean American Shoulder and Elbow Surgeons Score from 12 to 76, the mean Oxford shoulder score from 3 to 39, the mean Western Ontario Osteoarthritis of the Shoulder Score from 1618 to 418 and the mean Subjective shoulder value from 15 to 61. On radiological review, one patient had a lucency around the humeral stem, two had stress shielding. There were no fatigue fractures of the acromion but four cases of grade 1 scapular notching. . The use of a convertible prosthetic system to revise a failed ASA reduces morbidity and minimises the rate of complications. The mid-term clinical and radiological results of this technique are promising. Cite this article: Bone Joint J 2015;97-B:1662–7


Bone & Joint 360
Vol. 9, Issue 6 | Pages 15 - 18
1 Dec 2020


The Bone & Joint Journal
Vol. 98-B, Issue 6 | Pages 857 - 864
1 Jun 2016
Grimer RJ Aydin BK Wafa H Carter SR Jeys L Abudu A Parry M

Aims. The aim of this study was to establish what happens to patients in the long term after endoprosthetic replacement for a primary malignant tumour of bone. . Patients and Methods. We conducted a retrospective analysis of a prospectively maintained database to identify all patients who had undergone an endoprosthetic replacement more than 25 years ago and who were still alive. Their outcomes were investigated with reference to their complications and need for further surgery. A total of 230 patients were identified. Their mean age at diagnosis was 20.7 years (five to 62). The most common diagnosis was osteosarcoma (132). The most common site was the distal femur (102). . Results. The mean follow-up was 29.4 years (25 to 43). A total of 610 further operations were undertaken, an average of 2.7 further operations per patient. A total of 42 patients (18%) still had the original prosthesis in place. The risk of amputation was 16% at 30 years (31 patients). Those without infection had a mean of 2.1 further operations (one to nine) while those with infection had a mean of 4.6 further operations (two to 11). The risk of infection persisted throughout the life of the prosthesis with a mean of 1% per year becoming infected. Of the 60 patients who developed an infection, 21 (35%) developed this following the primary procedure at a mean of 50 months, but another 19 developed this within a year of another surgical procedure. The risk of infection after any further surgery was 2.7%. The site with the highest risk of infection was the proximal tibia (43.3%). Take home message: This study highlights the inevitable need for further surgery following first-generation endoprosthetic reconstruction, although in most cases, limb salvage is maintained. Late complications, especially infection, continue for the lifetime of the implant. Cite this article: Bone Joint J 2016;98-B:857–64


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1373 - 1377
1 Oct 2009
Spiegelberg BGI Sewell MD Aston WJS Blunn GW Pollock R Cannon SR Briggs TWR

This paper describes the preliminary results of a proximal tibial endoprosthesis which spares the knee joint and enables retention of the natural articulation by replacing part of the tibial metaphysis and diaphysis. In eight patients who had a primary malignant bone tumour of the proximal tibia, the distal stem, which had a hydroxyapatite-coated collar to improve fixation, was cemented into the medullary canal. The proximal end had hydroxyapatite-coated extracortical plates which were secured to the remaining proximal tibial metaphysis using cortical screws. The mean age of the patients at operation was 28.9 years (8 to 43) and the mean follow-up was for 35 months (4 to 48). The mean Musculoskeletal Tumour Society score was 79% (57% to 90%), the mean Oxford Knee score was 40 points of 48 (36 to 46) and the mean knee flexion was 112° (100° to 120°). In one patient, revision to a below-knee amputation through the prosthesis was required because of recurrence of the tumour. Another patient sustained a periprosthetic fracture which healed with a painful malunion. This was revised to a further endoprosthesis which replaced the knee. In the remaining six patients the prosthesis allowed preservation of the knee joint with good function and no early evidence of loosening. Further follow-up is required to assess the longevity of these prostheses


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 668 - 671
1 May 2010
Naqui SZ Rajpura A Nuttall D Prasad P Trail IA

This is a retrospective review of the results of the Acclaim total elbow replacement in 11 older patients aged ≥ 65 years with primary osteoarthritis of the elbow, with a mean follow-up of 57.6 months (30 to 86.4). Significant reductions in pain and improvement in range of movement and function were recorded. Radiological review revealed two patients with 1 mm lucencies in a single zone, and one patient with 1 mm lucencies in two zones. No components required revision. There were no deep infections, dislocations or mechanical failures. Complications included one intra-operative medial condylar fracture and one post-operative transient ulnar neuropathy, which resolved. This study demonstrates that the Acclaim prosthesis provides good symptomatic relief and improvement of function in patients with primary osteoarthritis, with low rates of loosening or other complications. This prosthesis can therefore be considered for patients aged ≥ 65 years with primary osteoarthritis of the elbow


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 7 | Pages 990 - 991
1 Jul 2011
Mirzatolooei F

We report a variant of tibial hemimelia in a six-year-old boy that did not comply with recognised classification systems. The femur and knee were normal, but the fibula was displaced proximally and there was severe diastasis of the proximal and distal tibiofibular joints to the extent that a grossly deformed foot articulated with the fibula and there was separate soft-tissue cover for the distal tibia and fibula. Although it would have been preferable to create a one-bone leg, amputate the foot and use the fibula as the stump for a below-knee prosthesis, local circumstances resulted in the choice of a disarticulation through the knee. This was undertaken without complications, and six months post-operatively the child was walking comfortably with a prosthesis


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 949 - 950
1 Jul 2006
Lloyd JM Calder JDF

The Thompson hemiarthroplasty is a popular hip prosthesis. We present two case reports highlighting a significant alteration in the design of the implant which compromised the success of the operations. In recent years the manufacturing process of this prosthesis has changed, with a resultant increase in the volume of the stem of 10 ml. It is essential that manufacturers inform orthopaedic surgeons of any alteration in the design of the implant and supply compatible instrumentation to minimise surgical errors. Surgeons must remain vigilant when checking the compatibility of the trial and definitive prostheses


Bone & Joint 360
Vol. 9, Issue 5 | Pages 28 - 32
1 Oct 2020


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1416 - 1421
1 Oct 2010
Qureshi F Draviaraj KP Stanley D

Between September 1993 and September 1996, we performed 34 Kudo 5 total elbow replacements in 31 rheumatoid patients. All 22 surviving patients were reviewed at a mean of 11.9 years (10 to 14). Their mean age was 56 years (37 to 78) at the time of operation. All had Larsen grade IV or V rheumatoid changes on X-ray. Nine (three bilateral replacements and six unilateral) had died from unrelated causes. One who had died before ten years underwent revision for dislocation. Of the 22 total elbow replacements reviewed six had required revision, four for aseptic loosening (one humeral and three ulnar) and two for infection. Post-operatively, one patient had neuropraxia of the ulnar nerve and one of the radial nerve. Two patients had valgus tilting of the ulnar component. With revision as the endpoint, the mean survival time for the prosthesis was 11.3 years (95% confidence interval (10 to 13) and the estimated survival of the prosthesis at 12 years according to Kaplan-Meier survival analysis was 74% (95% confidence interval 0.53 to 0.91). Of the 16 surviving implants, ten were free from pain, four had mild pain and two moderate. The mean arc of flexion/extension of the elbow was 106° (65° to 130°) with pronation/supination of 90° (30° to 150°) with the joint at 90° of flexion. The mean Mayo elbow performance score was 82 (60 to 100) with five excellent, ten good and one fair result. Good long-term results can be expected using the Kudo 5 total elbow replacement in patients with rheumatoid disease, with a low incidence of loosening of the components


Bone & Joint 360
Vol. 10, Issue 1 | Pages 28 - 31
1 Feb 2021


Bone & Joint Research
Vol. 9, Issue 11 | Pages 808 - 820
1 Nov 2020
Trela-Larsen L Kroken G Bartz-Johannessen C Sayers A Aram P McCloskey E Kadirkamanathan V Blom AW Lie SA Furnes ON Wilkinson JM

Aims

To develop and validate patient-centred algorithms that estimate individual risk of death over the first year after elective joint arthroplasty surgery for osteoarthritis.

Methods

A total of 763,213 hip and knee joint arthroplasty episodes recorded in the National Joint Registry for England and Wales (NJR) and 105,407 episodes from the Norwegian Arthroplasty Register were used to model individual mortality risk over the first year after surgery using flexible parametric survival regression.


The Bone & Joint Journal
Vol. 98-B, Issue 6 | Pages 829 - 833
1 Jun 2016
Hou Y Nie L Pan X Si M Han Y Li J Zhang H

Aims. In order to evaluate the effectiveness of the Mobi-C implant in cervical disc degeneration, a randomised study was conducted, comparing the Mobi-C prosthesis arthroplasty with anterior cervical disc fusion (ACDF) in patients with single level cervical spondylosis. Patients and Methods. From January 2008 to July 2009, 99 patients were enrolled and randomly divided into two groups, those having a Mobi-C implant (n = 51; 30 men, 21 women) and those undergoing ACDF (n = 48; 28 men, 20 women).The patients were followed up for five years, with the primary outcomes being the Japanese Orthopaedic Association score, visual analogue scale for pain and the incidence of further surgery. The secondary outcomes were the Neck Disability Index and range of movement (ROM) of the treated segment. Results. The incidence of further surgery was found to be statistically significant between the two groups (p = 0.49), with seven ACDF patients requiring further surgery and only one Mobi-C patient requiring re-operation. There were significant differences (p < 0.001) between the two groups in the ROM of the treated segment. However, both Mobi-C surgery and ACDF surgery were effective in improving the patient’s clinical symptoms. Take home message: Mobi-C implant surgery is a safe alternative to ACDF surgery in cervical disc degeneration. Cite this article: Bone Joint J 2016;98-B:829–3


The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 58 - 64
1 Jan 2016
Ahmed I Salmon LJ Waller A Watanabe H Roe JP Pinczewski LA

Aims. Oxidised zirconium was introduced as a material for femoral components in total knee arthroplasty (TKA) as an attempt to reduce polyethylene wear. However, the long-term survival of this component is not known. . Methods. We performed a retrospective review of a prospectively collected database to assess the ten year survival and clinical and radiological outcomes of an oxidised zirconium total knee arthroplasty with the Genesis II prosthesis. . The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Knee Injury and Osteoarthritis Outcome Score (KOOS) and a patient satisfaction scale were used to assess outcome. Results. A total of 303 consecutive TKAs were performed in 278 patients with a mean age of 68 years (45 to 89). The rate of survival ten years post-operatively as assessed using Kaplan–Meier analysis was 97% (95% confidence interval 94 to 99) with revision for any reason as the endpoint. There were no revisions for loosening, osteolysis or failure of the implant. There was a significant improvement in all components of the WOMAC score at final follow-up (p < 0.001). The mean individual components of the KOOS score for symptoms (82.4 points; 36 to 100), pain (87.5 points; 6 to 100), activities of daily life (84.9 points; 15 to 100) and quality of life (71.4 points; 6 to 100) were all at higher end of the scale. . Discussion. This study provides further supportive evidence that the oxidised zirconium TKA gives comparable rates of survival with other implants and excellent functional outcomes ten years post-operatively. Take home message: Total knee arthroplasty with an oxidised zirconium femoral component gives comparable long-term rates of survival and functional outcomes with conventional implants. . Cite this article: Bone Joint J 2016;98-B:58–64


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1689 - 1696
1 Dec 2020
Halai MM Pinsker E Mann MA Daniels TR

Aims

Preoperative talar valgus deformity ≥ 15° is considered a contraindication for total ankle arthroplasty (TAA). We compared operative procedures and clinical outcomes of TAA in patients with talar valgus deformity ≥ 15° and < 15°.

Methods

A matched cohort of patients similar for demographics and components used but differing in preoperative coronal-plane tibiotalar valgus deformity ≥ 15° (valgus, n = 50; 52% male, mean age 65.8 years (SD 10.3), mean body mass index (BMI) 29.4 (SD 5.2)) or < 15° (control, n = 50; 58% male, mean age 65.6 years (SD 9.8), mean BMI 28.7 (SD 4.2)), underwent TAA by one surgeon. Preoperative and postoperative radiographs, Ankle Osteoarthritis Scale (AOS) pain and disability and 36-item Short Form Health Survey (SF-36) version 2 scores were collected prospectively. Ancillary procedures, secondary procedures, and complications were recorded.


Bone & Joint 360
Vol. 4, Issue 2 | Pages 12 - 14
1 Apr 2015

The April 2015 Knee Roundup360 looks at: Genetic determinants of ACL strength; TKA outcomes influenced by prosthesis; Single- or two-stage revision for infected TKA?; Arthroscopic meniscectomy: a problem that just won’t go away!; Failure in arthroscopic ACL reconstruction; ACL reconstruction in the over 50s?; Knee arthroplasty for early osteoarthritis; All inside meniscal repair; Steroids, thrombogenic markers and TKA


Bone & Joint Research
Vol. 10, Issue 2 | Pages 96 - 104
28 Jan 2021
Fang X Zhang L Cai Y Huang Z Li W Zhang C Yang B Lin J Wahl P Zhang W

Aims

Microbiological culture is a key element in the diagnosis of periprosthetic joint infection (PJI). However, cultures of periprosthetic tissue do not have optimal sensitivity. One of the main reasons for this is that microorganisms are not released from the tissues, either due to biofilm formation or intracellular persistence. This study aimed to optimize tissue pretreatment methods in order to improve detection of microorganisms.

Methods

From December 2017 to September 2019, patients undergoing revision arthroplasty in a single centre due to PJI and aseptic failure (AF) were included, with demographic data and laboratory test results recorded prospectively. Periprosthetic tissue samples were collected intraoperatively and assigned to tissue-mechanical homogenization (T-MH), tissue-manual milling (T-MM), tissue-dithiothreitol (T-DTT) treatment, tissue-sonication (T-S), and tissue-direct culture (T-D). The yield of the microbial cultures was then analyzed.