Surgical dislocation of the hip in the treatment of acetabular fractures allows the femoral head to be safely displaced from the acetabulum. This permits full intra-articular acetabular and femoral inspection for the evaluation and potential treatment of cartilage lesions of the labrum and femoral head, reduction of the fracture under direct vision and avoidance of intra-articular penetration with hardware. We report 60 patients with selected types of acetabular fracture who were treated using this approach. Six were lost to follow-up and the remaining 54 were available for clinical and radiological review at a mean follow-up of 4.4 years (2 to 9). Substantial damage to the intra-articular cartilage was found in the anteromedial portion of the femoral head and the posterosuperior aspect of the acetabulum. Labral lesions were predominantly seen in the posterior acetabular area. Anatomical reduction was achieved in 50 hips (93%) which was considerably higher than that seen in previous reports. There were no cases of avascular necrosis. Four patients subsequently required total hip replacement. Good or excellent results were achieved in 44 hips (81.5%). The cumulative eight-year survivorship was 89.0% (95% confidence interval 84.5 to 94.1). Significant predictors of poor outcome were involvement of the acetabular dome and lesions of the femoral cartilage greater than grade 2. The functional mid-term results were better than those of previous reports. Surgical dislocation of the hip allows accurate reduction and a predictable mid-term outcome in the management of these difficult injuries without the risk of the development of avascular necrosis.
Small animal models of fracture repair primarily investigate
indirect fracture healing via external callus formation. We present
the first described rat model of direct fracture healing. A rat tibial osteotomy was created and fixed with compression
plating similar to that used in patients. The procedure was evaluated
in 15 cadaver rats and then Objectives
Methods
In order to identify the risk factors and the incidence of post-operative spinal epidural haematoma, we analysed the records of 14 932 patients undergoing spinal surgery between 1984 and 2002. Of these, 32 (0.2%) required re-operation within one week of the initial procedure and had an International Classification of Diseases (ICD)-9 code for haematoma complicating a procedure (998.12). As controls, we selected those who had undergone a procedure of equal complexity by the same surgeon but who had not developed this complication. Risks identified before operation were older than 60 years of age, the use of pre-operative non-steroidal anti-inflammatories and Rh-positive blood type. Those during the procedure were involvement of more than five operative levels, a haemoglobin <
10 g/dL, and blood loss >
1 L, and after operation an international normalised ratio >
2.0 within the first 48 hours. All these were identified as significant (p <
0.03). Well-controlled anticoagulation and the use of drains were not associated with an increased risk of post-operative spinal epidural haematoma.
We describe the experience with the first consecutive 230 Birmingham hip resurfacings at our centre. At a mean follow-up of three years (25 to 52 months) survivorship was 99.14% with revision in one patient for a loose acetabular component and one death from unrelated causes. One patient developed a fracture of the femoral neck at six weeks which united unremarkably after a period of non-weight-bearing. The Harris hip score improved from a mean of 62.54 (8 to 92) to 97.74 (61 to 100). The mean flexion improved from 91.52° (25 to 140) to 110.41° (80 to 145). Most patients (97%) considered the outcome to be good or excellent. Our preliminary experience with this implant is encouraging and the results are superior to the earlier generation of resurfacings for the same length of follow-up.
We report the general mortality rate after total
knee replacement and identify independent predictors of survival. We
studied 2428 patients: there were 1127 men (46%) and 1301 (54%)
women with a mean age of 69.3 years (28 to 94). Patients were allocated
a predicted life expectancy based on their age and gender. There were 223 deaths during the study period. This represented
an overall survivorship of 99% (95% confidence interval (CI) 98
to 99) at one year, 90% (95% CI 89 to 92) at five years, and 84%
(95% CI 82 to 86) at ten years. There was no difference in survival
by gender. A greater mortality rate was associated with increasing
age (p <
0.001), American Society of Anesthesiologists (ASA)
grade (p <
0.001), smoking (p <
0.001), body mass index (BMI)
<
20 kg/m2 (p <
0.001) and rheumatoid arthritis
(p <
0.001). Multivariate modelling confirmed the independent
effect of age, ASA grade, BMI, and rheumatoid disease on mortality.
Based on the predicted average mortality, 114 patients were predicted
to have died, whereas 217 actually died. This resulted in an overall
excess standardised mortality ratio of 1.90. Patient mortality after
TKR is predicted by their demographics: these could be used to assign
an individual mortality risk after surgery.
The purpose of this study was to investigate
whether a gender-specific high-flexion posterior-stabilised (PS)
total knee replacement (TKR) would offer advantages over a high-flex
PS TKR regarding range of movement (ROM), ‘feel’ of the knee, pain
and satisfaction, as well as during activity. A total of 24 female
patients with bilateral osteoarthritis entered this prospective,
blind randomised trial in which they received a high-flex PS TKR
in one knee and a gender-specific high-flexion PS TKR in the other
knee. At follow-up, patients were assessed clinically measuring
ROM, and questioned about pain, satisfaction and daily ‘feel’ of
each knee. Patients underwent gait analysis pre-operatively and
at one year, which yielded kinematic, kinetic and temporospatial
parameters indicative of knee function during gait. At final follow-up
we found no statistically significant differences in ROM (p = 0.82).
The median pain score was 0 (0 to 8) in both groups (p = 0.95).
The median satisfaction score was 9 (4 to 10) in the high-flex group
and 8 (0 to 10) in the gender-specific group (p = 0.98). The median
‘feel’ score was 9 (3 to 10) in the high-flex group and 8 (0 to
10) in the gender-specific group (p = 0.66). Gait analysis showed
no statistically significant differences between the two prosthetic
designs in any kinematic, kinetic or temporospatial parameters. Both designs produced good clinical results with
Patients with infected arthroplasties are normally
treated with a two-stage exchange procedure using polymethylmethacrylate
bone cement spacers impregnated with antibiotics. However, spacers
may act as a foreign body to which micro-organisms may adhere and
grow. In this study it was hypothesised that subclinical infection may
be diagnosed with sonication of the surface biofilm of the spacer.
The aims were to assess the presence of subclinical infection through
sonication of the spacer at the time of a second-stage procedure,
and to determine the relationship between subclinical infection
and the clinical outcome. Of 55 patients studied, 11 (20%) were
diagnosed with subclinical infection. At a mean follow-up of 12
months (interquartile range 6 to 18), clinical failure was found in
18 (32.7%) patients. Of the patients previously diagnosed with subclinical
infection, 63% (7 of 11) had failed compared with 25% (11 of 44)
of those without subclinical infection (odds ratio 5.25, 95% confidence
interval 1.29 to 21.4, p = 0.021). Sonication of the biofilm of
the surface of the spacer is useful in order to exclude subclinical infection
and therefore contributes to improving the outcome after two-stage
procedures.
Peri-articular soft-tissue masses or ‘pseudotumours’
can occur after large-diameter metal-on-metal (MoM) resurfacing
of the hip and conventional total hip replacement (THR). Our aim
was to assess the incidence of pseudotumour formation and to identify
risk factors for their formation in a prospective cohort study. A total of 119 patients who underwent 120 MoM THRs with large-diameter
femoral heads between January 2005 and November 2007 were included
in the study. Outcome scores, serum metal ion levels, radiographs
and CT scans were obtained. Patients with symptoms or an identified
pseudotumour were offered MRI and an ultrasound-guided biopsy. There were 108 patients (109 hips) eligible for evaluation by
CT scan at a mean follow-up of 3.6 years (2.5 to 4.5); 42 patients
(39%) were diagnosed with a pseudotumour. The hips of 13 patients
(12%) were revised to a polyethylene acetabular component with small-diameter
metal head. Patients with elevated serum metal ion levels had a
four times increased risk of developing a pseudotumour. This study shows a substantially higher incidence of pseudotumour
formation and subsequent revisions in patients with MoM THRs than
previously reported. Because most revision cases were identified
only after an intensive screening protocol, we recommend close monitoring
of patients with MoM THR.
The results of primary total knee replacement performed on a group of haemophiliac patients in a single institution by the same surgeon using the same surgical technique and prosthesis are reported. A total of 35 primary replacements in 30 patients were carried out between 1996 and 2005 and were reviewed retrospectively. The mean age of the patients was 31 years (24 to 42) and the mean follow-up was for 7.5 years (1 to 10). There were 25 patients with haemophilia A and five with haemophilia B. The HIV status and CD4 count were recorded, and Knee Society scores determined. Two patients had inhibitors to the deficient coagulation factor. There were no early wound infections and only one late deep infection which required a two-stage revision arthroplasty, with a good final result. The incidence of infection in HIV-positive and negative patients was thus similar. One knee in a patient with inhibitor had excessive bleeding due to a pseudoaneurysm which required embolisation. The results were excellent in 27 knees (77%), good in six (17%) and fair in two (6%). The survival rate at 7.5 years taking removal of the prosthesis for loosening or infection as the end-point was 97%. The mechanical survival of total knee replacements in haemophiliacs is very good. Our results confirm that this is a reproducible procedure in haemophilia, even in HIV-positive patients with a CD4 count >
200 mm3 and those with inhibitors. Our rate of infection was lower than previously reported. This could be due to better control of the HIV status with highly active anti-retroviral therapy and the use of antibiotic-loaded cement.
This prospective study compares the outcome of
157 hydroxyapatite (HA)-coated tibial components with 164 cemented
components in the ROCC Rotating Platform total knee replacement
in 291 patients. The mean follow-up was 7.6 years (5.2 to 11). There
were two revisions for loosening: one for an HA-coated and one for
a cemented tibial component. Radiological evaluation demonstrated
no radiolucent lines with the HA-coated femoral components. A total
of three HA-coated tibial components exhibited radiolucent lines
at three months post-operatively and these disappeared after three
further months of protected weight-bearing. With HA-coated components
the operating time was shorter (p <
0.006) and the radiological
assessment of the tibial interface was more stable (p <
0.01).
Using revision for aseptic loosening of the tibial component as
the end point, the survival rates at nine years was identical for
both groups at 99.1%. Our results suggest that HA-coated components perform at least
as well as the same design with cemented components and compare
favourably with those of series describing cemented or porous-coated
knee replacements, suggesting that fixation of both components with
hydroxyapatite is a reliable option in primary total knee replacement.
We have evaluated the functional, clinical and radiological outcome of patients with simple and complex acetabular fractures involving the posterior wall, and identified factors associated with an adverse outcome. We reviewed 128 patients treated operatively for a fracture involving the posterior wall of the acetabulum between 1982 and 1999. The Musculoskeletal Functional Assessment and Short-Form 36 scores, the presence of radiological arthritis and complications were assessed as a function of injury, treatment and clinical variables. The patients had profound functional deficits compared with the normal population. Anatomical reduction alone was not sufficient to restore function. The fracture pattern, marginal impaction and residual displacement of >
2 mm were associated with the development of arthritis, which related to poor function and the need for hip replacement. It may be appropriate to consider immediate total hip replacement for patients aged >
50 years with marginal impaction and comminution of the wall, since 7 of 13 (54%) of these required early hip replacement.
We report a case of fatal pulmonary embolism following a simple ankle fracture in a 17-year-old girl. The diagnosis was confirmed at post-mortem. The risk factors for deep venous thrombosis and pulmonary embolism and their significance in orthopaedic fracture management are discussed.
We evaluated the incidence of heterotopic ossification
following total ankle replacement to determine whether the degree
of ossification was associated with the clinical outcome. We evaluated
90 ankles in 81 consecutive patients who underwent total ankle replacement,
and heterotopic ossification was assessed according to proportional involvement
of the ankle joint. Correlation analysis was used to investigate
the association between heterotopic ossification and outcome. No significant association was found between the formation of
heterotopic ossification and the clinical outcome. The degree of
heterotopic ossification in the posterior ankle joint was not significantly
correlated with posterior ankle pain (p = 0.929), the American Orthopaedic
Foot and Ankle Society score (p = 0.454) or range of movement (p
= 0.283). This study indicates that caution should be observed in attributing
symptoms and functional limitation to the presence of heterotopic
ossification in the posterior ankle joint when considering excision
of heterotopic bone after total ankle replacement.
The aim of this study was to investigate the
possible benefit of large-head metal-on-metal bearing on a stem
for primary hip replacement compared with a 28 mm diameter conventional
metal-on-polyethylene bearing in a prospective randomised controlled
trial. We investigated cemented stem behaviour between these two
different bearings using Einzel-Bild-Röntgen-Analyse, clinical and
patient reported measures (Harris hip score, Western Ontario and
McMaster Universities osteoarthritis index, Short Form-36 and satisfaction)
and whole blood metal ion levels at two years. A power study indicated
that 50 hips were needed in each group to detect subsidence of >
5 mm at two years with a
p-value of <
0.05. Significant improvement (p <
0.001) was found in the mean
clinical and patient reported outcomes at two years for both groups.
Comparison of outcomes between the groups at two years showed no
statistically significant difference for mean stem migration, clinical
and patient reported outcomes; except overall patient satisfaction which
was higher for metal-on-metal group (p = 0.05). Metal ion levels
were raised above the Medicines and Healthcare products Regulatory
Agency advised safety level (7 µg per litre) in 20% of the metal-on-metal
group and in one patient in metal-on-polyethylene group (who had
a metal-on-metal implant on the contralateral side). Two patients
in the metal-on-metal group were revised, one for pseudotumour and
one for peri-prosthetic fracture. Use of large modular heads is associated with a risk of raised
whole blood metal ion levels despite using a proven bearing from
resurfacing. The head-neck junction or excess stem micromotion are
possibly the weak links warranting further research.
We evaluated the safety and efficacy of total
knee replacement in patients receiving continuous warfarin therapy. We identified 24 consecutive patients receiving long-term warfarin
therapy who underwent total knee replacement between 2006 and 2008
and compared them with a group of age- and gender-matched patients
not on long-term anticoagulation. Primary observations were changes
in haemoglobin, transfusion rates and complications. Secondary observations
were fluctuations in the international normalised ratio (INR) and
post-operative range of movement. There was no significant difference between the two groups in
pre- or post-operative haemoglobin, incidence of transfusion or
incidence of post-operative complications. There were no surgical
delays due to a high INR level. The mean change in INR during the
peri-operative phase was minimal (mean 0.4; Current American College of Chest Physicians guidelines recommend
bridging therapy for high-risk patients receiving oral anticoagulation
and undergoing major orthopaedic procedures. We have shown that
a safe alternative is to continue the steady-state warfarin peri-operatively
in patients on long-term anticoagulation requiring total knee replacement.
Correct positioning and alignment of components during primary total knee replacement (TKR) is widely accepted to be an important predictor of patient satisfaction and implant durability. This retrospective study reports the effect of the post-operative mechanical axis of the lower limb in the coronal plane on implant survival following primary TKR. A total of 501 TKRs in 396 patients were divided into an aligned group with a neutral mechanical axis (± 3°) and a malaligned group where the mechanical axis deviated from neutral by >
3°. At 15 years’ follow-up, 33 of 458 (7.2%) TKRs were revised for aseptic loosening. Kaplan-Meier survival analysis showed a weak tendency towards improved survival with restoration of a neutral mechanical axis, but this did not reach statistical significance (p = 0.47). We found that the relationship between survival of a primary TKR and mechanical axis alignment is weaker than that described in a number of previous reports.
We analysed the incidence of slipped capital
femoral epiphysis (SCFE) in South Australia, investigating possible associations
between an increased incidence of SCFE, the local indigenous population
and the Australian obesity epidemic during the last 20 years. Data
including race, age and gender were collected to obtain a profile
of the South Australian SCFE patient, and were then compared with
epidemiological data for South Australian adolescents. We concluded
that the incidence of both obesity and SCFE is increasing. We also
noted that the median weight of SCFE patients has increased and
the mean age at diagnosis has decreased. Despite weight profiles
comparable with those of the general population, we noted that an
indigenous child was three times more likely to develop SCFE than
a non-indigenous child. As far as we know there is no published
literature on the predisposition of Aboriginal Australians to SCFE.
The efficacy of circumpatellar electrocautery in reducing the incidence of post-operative anterior knee pain is unknown. We conducted a single-centre, outcome-assessor and patient-blinded, parallel-group, randomised, controlled trial to compare circumpatellar electrocautery with no electrocautery in total knee replacement in the absence of patellar resurfacing. Patients requiring knee replacement for primary osteoarthritis were randomly assigned circumpatellar electrocautery (intervention group) or no electrocautery (control group). The primary outcome measure was the incidence of anterior knee pain. A secondary measure was the standardised clinical and patient-reported outcomes determined by the American Knee Society scores and the Western Ontario and McMaster Universities (WOMAC) osteoarthritis index. A total of 131 knees received circumpatellar electrocautery and 131 had no electrocautery. The overall incidence of anterior knee pain at follow-up at one year was 26% (20% to 31%), with 19% (12% to 26%) in the intervention group and 32% (24% to 40%) in the control group (p = 0.02). The relative risk reduction from electrocautery was 40% (9% to 61%) and the number needed to treat was 7.7 (4.3 to 41.4). The intervention group had a better mean total WOMAC score at follow-up at one year compared with the control group (16.3 (0 to 77.7) Our study suggests that in the absence of patellar resurfacing electrocautery around the margin of the patella improves the outcome of total knee replacement.
Prospective data on hip fracture from 3686 patients at a United Kingdom teaching hospital were analysed to investigate the risk factors, financial costs and outcomes associated with deep or superficial wound infections after hip fracture surgery. In 1.2% (41) of patients a deep wound infection developed, and 1.1% (39) had a superficial wound infection. A total of 57 of 80 infections (71.3%) were due to No statistically significant pre-operative risk factors were detected. Length of stay, cost of treatment and pre-discharge mortality all significantly increased with deep wound infection. The one-year mortality was 30%, and this increased to 50% in those who developed an infection (p <
0.001). A deep infection resulted in doubled operative costs, tripled investigation costs and quadrupled ward costs. MRSA infection increased costs, length of stay, and pre-discharge mortality compared with non-MRSA infection.