Advertisement for orthosearch.org.uk
Results 541 - 560 of 1198
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 2 | Pages 264 - 269
1 Mar 1996
Tsuchiya H Tomita K Shinokawa Y Minematsu K Katsuo S Taki J

We have used the Ilizarov technique for the management of subarticular defects after the excision of giant-cell tumours in the proximal tibia in five patients. The defect was reconstructed with a segment of 5 to 6 cm obtained from the diaphysis of the affected tibia and by autogenous bone graft from the iliac crest. The newly developed defect in the diaphysis was reconstructed by distraction using the Ilizarov apparatus. Bone grafting at the docking site was performed soon after positioning the bone segments. The mean length of the bone defect was 5.7 cm and the mean duration of external fixation was 233 days. The relative blood flow in the leg measured by . 99m. Tc angiography increased by 1.7 to 2.3 times that of the control level during distraction and consolidation. When seen at a mean of 43 months all patients showed a normal range of motion in the knee and ankle with no collapse of the articular surfaces


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 311 - 316
1 Mar 2019
Löchel J Janz V Hipfl C Perka C Wassilew GI

Aims

The use of trabecular metal (TM) shells supported by augments has provided good mid-term results after revision total hip arthroplasty (THA) in patients with a bony defect of the acetabulum. The aim of this study was to assess the long-term implant survivorship and radiological and clinical outcomes after acetabular revision using this technique.

Patients and Methods

Between 2006 and 2010, 60 patients (62 hips) underwent acetabular revision using a combination of a TM shell and augment. A total of 51 patients (53 hips) had complete follow-up at a minimum of seven years and were included in the study. Of these patients, 15 were men (29.4%) and 36 were women (70.6%). Their mean age at the time of revision THA was 64.6 years (28 to 85). Three patients (5.2%) had a Paprosky IIA defect, 13 (24.5%) had a type IIB defect, six (11.3%) had a type IIC defect, 22 (41.5%) had a type IIIA defect, and nine (17%) had a type IIIB defect. Five patients (9.4%) also had pelvic discontinuity.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 464 - 471
1 May 1999
Parthasarathy R Sriram K Santha T Prabhakar R Somasundaram PR Sivasubramanian S

We performed a randomised, controlled clinical trial to compare ambulant short-course chemotherapy with anterior spinal fusion plus short-course chemotherapy for spinal tuberculosis without paraplegia. Patients with active disease of vertebral bodies were randomly allocated to one of three regimens: a) radical anterior resection with bone grafting plus six months of daily isoniazid plus rifampicin (Rad6); b) ambulant chemotherapy for six months with daily isoniazid plus rifampicin (Amb6); or c) similar to b) but with chemotherapy for nine months (Amb9). Ten years from the onset of treatment, 90% of 78 Rad6, 94% of 78 Amb6 and 99% of 79 Amb9 patients had a favourable status. Ambulant chemotherapy for a period of six months with daily isoniazid plus rifampicin (Amb6) was an effective treatment for spinal tuberculosis except in patients aged less than 15 years with an initial angle of kyphosis of more than 30° whose kyphosis increased substantially


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1385 - 1391
1 Oct 2018
Qvist AH Væsel MT Jensen CM Jensen SL

Aims

Recent studies of nonoperatively treated displaced midshaft clavicular fractures have shown a high incidence of nonunion and unsatisfactory functional outcome. Some studies have shown superior functional results and higher rates of healing following operative treatment. The aim of this study was to compare the outcome in these patients after nonoperative management with those treated with fixation.

Patients and Methods

In a multicentre, parallel randomized controlled trial, 146 adult patients with an acute displaced fracture of the midthird of the clavicle were randomized to either nonoperative treatment with a sling (71, 55 men and 16 women with a mean age of 39 years, 18 to 60) or fixation with a pre-contoured plate and locking screws (75, 64 men and 11 women with a mean age of 40 years, 18 to 60). Outcome was assessed using the Disabilities of the Arm, Shoulder and Hand (DASH) Score, the Constant Score, and radiographical evidence of union. Patients were followed for one year.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 3 | Pages 430 - 433
1 May 1991
Fredin H Sanzen L Sigurdsson B Unander-Scharin L

Total arthroplasty was performed on 21 congenitally dislocated hips in 18 women. In all cases the femoral head was dislocated cranially at least one-fifth of the height of the pelvis. The components were both cemented, the acetabulum being replaced to its original position. The acetabular roof was reconstructed by bone graft in 13 hips, and trochanteric osteotomy was done in 18 hips. The patients were assessed at a median follow-up time of 7.5 years when their median age was 54 years. Nine patients had been revised or required revision. At follow-up the average functional score (according to Charnley) was 6 for pain, 4 for walking ability and 5 for range of motion. The Harris hip score was 82. The patients' subjective evaluation of their satisfaction with the late results on a visual analogue scale was 93, range 23 to 100. The high loosening rate in such patients demands regular follow-up and preparedness for revision surgery


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 2 | Pages 211 - 215
1 Mar 1991
Simonis R Shirali H Mayou B

We describe 11 patients with congenital pseudarthrosis of the tibia treated by a free vascularised fibular graft (FVFG) and followed up from 10 to 64 months (mean 38). Bony union was achieved in nine of the 11 cases: two failures required amputation. The mean time for union in the successful cases was five months. Nine of the 11 patients had had an average of four surgical procedures before the FVFG, so the graft was a salvage procedure for which the only alternative was amputation. FVFG is recommended as a primary procedure for the treatment of congenital pseudarthrosis of the tibia if there is a large tibial defect (over 3 cm) or shortening of more than 5 cm. The primary use of this operation is not advised for cases in which standard orthopaedic procedures are expected to succeed. For a small defect with a favourable prognosis (Boyd and Sage 1958), we recommend conventional bone grafting, intramedullary nailing and electrical stimulation


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 260 - 265
1 Mar 2019
Lee SH Han SS Yoo BM Kim JW

Aims

The aim of this study was to evaluate the clinical and radiological outcomes of locking plate fixation, with and without an associated fibular strut allograft, for the treatment of displaced proximal humeral fractures in elderly osteoporotic patients.

Patients and Methods

We undertook a retrospective comparison of two methods of fixation, using a locking plate without an associated fibular strut allograft (LP group) and with a fibular allograft (FA group) for the treatment of these fractures. The outcome was assessed for 52 patients in the LP group and 45 in the FA group, with a mean age of 74.3 years (52 to 89), at a mean follow-up of 14.2 months (12 to 19). The clinical results were evaluated using a visual analogue scale (VAS) score for pain, the Constant score, the American Shoulder and Elbow Surgeons (ASES) score, and the range of movement. Radiological results were evaluated using the neck-shaft angle (NSA) and humeral head height (HHH).


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 1 | Pages 114 - 123
1 Jan 1984
Herbert T Fisher W

A new and simple operative technique has been developed to provide rigid internal fixation for all types of fractures of the scaphoid. This involves the use of a double-threaded bone screw which provides such good fixation that, after operation, a plaster cast is rarely required and most patients are able to return to work within a few weeks. A classification of scaphoid fractures is proposed. The indications for operation included not only acute unstable fractures, but also fractures with delayed healing and those with established non-union; screw fixation was combined with bone grafting to treat non-union. In a prospective trial, 158 operations using this technique were carried out between 1977 and 1981. The rate of union was 100 per cent for acute fractures and 83 per cent overall. This method of treatment appears to offer significant advantages over conventional techniques in the management of the fractured scaphoid


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 2 | Pages 244 - 253
1 May 1981
Chacha P Ahmed M Daruwalla J

Failure of union of the tibia with a large defect is difficult to treat, especially in the presence of sepsis and adherent scars. Conventional methods of fixation and bone grafting are not easily applicable. Experiments on Macaca monkeys showed that a vascularised pedicle graft of the shaft of the ipsilateral fibula could be fixed across a defect in the tibia and remain viable, even if it was isolated from surrounding soft tissues. Transfer of part of the shaft of the ipsilateral fibula on a vascular and muscle pedicle was carried out in 11 patients with large tibial defects and sepsis. There was one failure because of severe infection, but the other 10 patients gained sound union in about four months. The tibia was then protected by a caliper for the 18 months of full reconstitution. The bone infection healed and there was no evidence of avascular necrosis. Although the salvaged limbs were scarred, stiff and ugly, none of the patients suffered from pain, recurrent oedema or persistent infection


The Journal of Bone & Joint Surgery British Volume
Vol. 49-B, Issue 3 | Pages 462 - 474
1 Aug 1967
Rosborough D Stiles PJ

1. One hundred and eight osteotomies were reviewed with regard to union, and fourteen were found to be ununited. In only one was non-union detected clinically; the others required radiographic demonstration. Tomographs were particularly helpful in confirming non-union. 2. Nine patients with non-union had pain, equal to or worse than before operation. The pain could not be distinguished from that of osteoarthritis of the hip. 3. Six of the patients with non-union needed an operation. Five had cancellous bone grafts followed by union in all except one. 4. The causes of non-union are reviewed. This complication was found to be less frequent in patients above sixty with stiff hips and bony collapse on the radiograph. Horizontal osteotomy with a displacement of not more than one-third of the diameter of the shaft reduced the incidence of non-union. The variable-angle nail-plate provided the best fixation. Traction provided no benefit and increased the incidence of non-union. Weight bearing is best avoided for eight weeks


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 2 | Pages 289 - 294
1 Mar 1997
Ring D Jupiter JB Sanders RA Quintero J Santoro VM Ganz R Marti RK

We have treated 42 consecutive complex ununited fractures of the femoral shaft by wave-plate osteosynthesis at five different medical centres. There were 13 with previous infection, 12 with segmental cortical defects, and 3 were pathological fractures. In 39 cases there had been previous internal fixation and 21 patients had had more than one earlier operation. Union was achieved in 41 patients at an average of six months, although three had required a second bone graft. Two patients had recurrence of infection and in one this resulted in the persistence of nonunion. There were no failures of the implant. All 41 patients with union are now fully weight-bearing, but four have a leg-length discrepancy, one has axial malalignment, and nine have residual stiffness of the knee. These results are surprisingly good, despite the complexity of the initial problem, and appear to confirm the biological and mechanical advantages of the wave plate over the conventional plate for such cases


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 1 | Pages 83 - 86
1 Jan 1997
Okamoto T Inao S Gotoh E Ando M

We performed Charnley total hip arthroplasties on 64 patients (71 hips) between 1976 and 1984 for moderate congenital acetabular dysplasia in which a superolateral cement thickness of less than 20 mm was expected when the cup was placed in the true acetabulum at an angle of 45°. Of these, 59 hips were examined 10 to 17 years after operation; 37 (group A) had been operated on between 1976 and 1982 using Charnley’s original technique of cementing the acetabulum and 22 (group B) between 1983 and 1984 using more modern techniques. In group A, aseptic loosening of the socket was observed in ten hips (27.0%) and the 17-year survival rate was 81.5%. In group B, loosening was noted in only one socket (4.5%) and the 13-year survival rate was 100%. The improved techniques produced significantly better long-term results in fixation of the cup in dysplastic hips without bone grafting


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 2 | Pages 176 - 184
1 Mar 2000
Iida H Matsusue Y Kawanabe K Okumura H Yamamuro T Nakamura T

Although the technique of autogenous acetabular bone grafting has been widely used to augment containment of the acetabulum in total hip arthroplasty (THA) for developmental dysplasia, the role of this technique in improving long-term results remains controversial. We present the long-term results of cemented THA with acetabular bone grafting in 112 patients (133 hips) in order to clarify the factors which affect the outcome. The mean follow-up was for 12.3 years (8 to 24). Kaplan-Meier survivorship analysis predicted a rate of survival of the acetabular component at 15 years of 96% (95% confidence interval (CI) 92 to 99) with revision for aseptic loosening as the endpoint, and of 75% (95% CI 65 to 85) when radiological loosening was used. Parametric survivorship analysis using the Cox proportional-hazards model indicated that trochanteric nonunion, lateral placement of the socket, and delayed trabecular reorientation of the bone graft were risk factors for loosening of the acetabular component. Our findings have shown that autologous acetabular bone grafting is of value for long-term success provided that the risk factors are reduced


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 454 - 460
1 Apr 2019
Lapner PLC Rollins MD Netting C Tuna M Bader Eddeen A van Walraven C

Aims

Few studies have compared survivorship of total shoulder arthroplasty (TSA) with hemiarthroplasty (HA). This observational study compared survivorship of TSA with HA while controlling for important covariables and accounting for death as a competing risk.

Patients and Methods

All patients who underwent shoulder arthroplasty in Ontario, Canada between April 2002 and March 2012 were identified using population-based health administrative data. We used the Fine–Gray sub-distribution hazard model to measure the association of arthroplasty type with time to revision surgery (accounting for death as a competing risk) controlling for age, gender, Charlson Comorbidity Index, income quintile, diagnosis, and surgeon factors.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 5 | Pages 683 - 690
1 Jul 2003
Kim HT Lee SH Yoo CI Kang JH Suh JT

We treated 35 brachymetatarsal rays of 18 feet in 12 patients by one-stage lengthening with interpositional bone grafts or by gradual lengthening with callotasis combined with shortening of the adjacent metatarsals and phalanges. Definition of the two parabolas which connect the metatarsal heads and the tips of the toes, and recognition of three patterns of metatarsal length, were helpful guides in treatment. In total, 36 excisions of the phalanges and/or the metatarsals were undertaken. The mean shortening was 8 mm. The radiological results were satisfactory. The mean values were as follows: one-stage lengthening, length gain, 1.3 cm; healing index, 1.3 months/cm; percentage increase, 30%; gradual lengthening, length gain, 2.0 cm; healing index, 2.0 months/cm; percentage increase, 50%. Associated shortening of an adjacent bone can avoid the disadvantages of one-stage lengthening which may not achieve target length and can result in neurovascular complications. Reduction of the target length enables the surgeon to carry out one-stage instead of gradual lengthening. It also shortens the length of treatment in the group undergoing callotasis and improves cosmesis


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 3 | Pages 362 - 365
1 May 1995
Raut V Siney P Wroblewski B

We reviewed prospectively cemented stem revision in 106 patients with severe femoral endosteal bone lysis without infection. Bone grafts were not used in any of the patients. The minimum follow-up was three years (mean 6 years 4 months). At the last review 76.4% of the patients were free of pain and 17.9% had only mild or occasional discomfort; radiographs showed well-fixed stable stems in 101 (95.3%). An intramedullary cement plug was used at revision to improve stability in 97.7%. There was new endosteal osteolysis after revision in 17 patients; only two had severe changes. Seven hips (6.6%) required a second revision; only four of these (3.8%) were for stem loosening. Survivorship of the revised stem, using radiological evidence of stem loosening as the end point, was 95.8% at seven years. The results of stem revision arthroplasty using cement in the presence of massive endosteal cavitation are satisfactory


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 2 | Pages 196 - 201
1 Mar 1993
Leung K Yuen K Chan W

Since 1986, we have treated displaced intra-articular fractures of the calcaneum by open reduction through a lateral approach, stable internal fixation and bone grafting. We assessed the results at a mean follow-up of 2.92 years in 44 patients, comparing them with those for 19 patients treated non-operatively. Clinical assessment used the scoring system of Crosby and Fitzgibbons (1990) and radiological measurements were made from lateral, axial and internal oblique views. The articular congruity of the subtalar joint and any arthritic changes were also assessed. We found significantly better results in the operated group with respect to pain, activity, range of movement, return to work and swelling of the hind foot. Radiologically, the operated group showed significantly better scores for articular congruity and arthritic changes. We conclude that the operative treatment of displaced intra-articular fractures of the calcaneum gives better medium-term results than conservative management


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 4 | Pages 635 - 642
1 Aug 1986
Nilsson O Urist M Dawson E Schmalzried T Finerman G

In dogs, resection of a length of the ulna equal to twice the diameter of the mid-shaft leaves a defect which consistently fails to unite. In response to an implant of 100 mg of bovine bone morphogenetic protein (BMP), the defect becomes filled by callus consisting of fibrocartilage, cartilage and woven bone within four weeks. The cartilage is resorbed and replaced by new bone in four to eight weeks. Woven bone is then resorbed, colonised by bone marrow cells and remodelled into lamellar bone. Union of the defect is produced by 12 weeks. Control defects filled with autogeneic cortical bone chips unite after the same period. In regeneration induced by bone morphogenetic protein (BMP) and in repair enhanced by bone graft, union depends upon the proliferation of cells within and around the bone ends. Our working hypothesis is that BMP induces the differentiation of perivascular connective tissue cells into chondroblasts and osteoprogenitor cells and thereby augments the process of bone regeneration from the cells already present in the endosteum and periosteum


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 1 | Pages 55 - 60
1 Jan 1986
Saito S Takaoka K Ono K

Tectoplasty is a new acetabuloplasty which aims to provide an extra-articular weight-bearing surface in cases of dysplastic acetabulum, hip subluxation or dislocation with a false acetabulum. The lateral wall of the iliac bone at the lateral edge of the affected acetabulum is raised as a proximally-based flap and massive bone grafts are inserted to provide a congruous, non-absorbable roof for the capsule and femoral head. An advantage is that the weight-bearing surface can be formed away from the original acetabulum, wherever the dislocated or subluxated femoral head may lie. Of 34 hips with congenital dislocation or severe subluxation treated by this method, 27 were evaluated after an average follow-up of 12 years. At review the patients averaged 35 years of age and satisfactory results with good relief of pain had been obtained in 78%. The results were unsatisfactory when degenerative changes had already developed before operation. Tectoplasty is indicated for pain due to congenital subluxation or dislocation of the hip under the age of thirty, in the absence of advanced osteoarthritis


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 1 | Pages 40 - 42
1 Jan 1983
Sijbrandij S

A modification of a previously reported one-stage technique for reduction and stabilisation of severe spondylolisthesis using a posterior route is described. Reduction is obtained by inserting Harrington rods to lift L5 vertically out of the pelvis and two double-threaded screws to pull it backwards. After reduction the rods are taken away and stabilisation achieved by means of screws and a sacral bar. With this modified technique lumbar vertebrae above L5 are never immobilised, compared with the previous method where the retention of the Harrington rods resulted in more lumbar vertebrae being immobilised than was necessary for fusion. Bone is resected from the sacrum and the fifth lumbar vertebra to avoid too much tension on the nerve roots. Bone grafts are not needed and lumbosacral fusion is achieved within six months due to close contact between the raw bone of the vertebral bodies. Three patients have been treated with this modified technique; there was no reslip, neither during the period when the metallic fixation was in situ nor after its removal