Advertisement for orthosearch.org.uk
Results 521 - 540 of 918
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 689 - 694
1 May 2011
Garrett BR Hoffman EB Carrara H

Distal femoral physeal fractures in children have a high incidence of physeal arrest, occurring in a mean of 40% of cases. The underlying nature of the distal femoral physis may be the primary cause, but other factors have been postulated to contribute to the formation of a physeal bar. The purpose of this study was to assess the significance of contributing factors to physeal bar formation, in particular the use of percutaneous pins across the physis.

We reviewed 55 patients with a median age of ten years (3 to 13), who had sustained displaced distal femoral physeal fractures. Most (40 of 55) were treated with percutaneous pinning after reduction, four were treated with screws and 11 with plaster. A total of 40 patients were assessed clinically and radiologically after skeletal maturity or at the time of formation of a bar. The remaining 15 were followed up for a minimum of two years.

Formation of a physeal bar occurred in 12 (21.8%) patients, with the rate rising to 30.6% in patients with high-energy injuries compared with 5.3% in those with low-energy injuries. There was a significant trend for physeal arrest according to increasing severity using the Salter-Harris classification. Percutaneous smooth pins across the physis were not statistically associated with growth arrest.


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 611 - 616
1 May 2015
Shin WC Lee SM Lee KW Cho HJ Lee JS Suh KT

There is no single standardised method of measuring the orientation of the acetabular component on plain radiographs after total hip arthroplasty. We assessed the reliability and accuracy of three methods of assessing anteversion of the acetabular component for 551 THAs using the PolyWare software and the methods of Liaw et al, and of Woo and Morrey. All measurements of the three methods had excellent intra- and inter-observer reliability. The values of the PolyWare software, which determines version of the acetabular component by edge detection were regarded as the reference standard. Although the PolyWare software and the method of Liaw et al were similarly precise, the method of Woo and Morrey was significantly less accurate (p < 0.001). The method of Liaw et al seemed to be more accurate than that of Woo and Morrey when compared with the measurements using the PolyWare software. If the qualified lateral radiograph was selected, anteversion measured using the method of Woo and Morrey was considered to be relatively reliable.

Cite this article: Bone Joint J 2015; 97-B:611–16.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 956 - 958
1 Jul 2007
Lee C Lashari S

Nutritional osteomalacia is a metabolic bone disorder common among the Asian female immigrant population in the United Kingdom. We describe the case of a female of Asian origin, who was found to have a unilateral undisplaced pseudofracture of the neck of the femur during pregnancy. Although not operated on the fracture was treated successfully with calcium and vitamin D supplement therapy. Within one month of treatment, the bone pain subsided and she was able to bear full weight. Subsequent radiological follow-up showed the pseudofracture to have healed sufficiently with no evidence of avascular necrosis.

There should be a high index of suspicion of this disease, particularly among Asian patients presenting with persistent and non-specific musculoskeletal pain.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1382 - 1389
1 Oct 2012
Sewell MD Kang SN Al-Hadithy N Higgs DS Bayley I Falworth M Lambert SM

There is little information about the management of peri-prosthetic fracture of the humerus after total shoulder replacement (TSR). This is a retrospective review of 22 patients who underwent a revision of their original shoulder replacement for peri-prosthetic fracture of the humerus with bone loss and/or loose components. There were 20 women and two men with a mean age of 75 years (61 to 90) and a mean follow-up 42 months (12 to 91): 16 of these had undergone a previous revision TSR. Of the 22 patients, 12 were treated with a long-stemmed humeral component that bypassed the fracture. All their fractures united after a mean of 27 weeks (13 to 94). Eight patients underwent resection of the proximal humerus with endoprosthetic replacement to the level of the fracture. Two patients were managed with a clam-shell prosthesis that retained the original components. The mean Oxford shoulder score (OSS) of the original TSRs before peri-prosthetic fracture was 33 (14 to 48). The mean OSS after revision for fracture was 25 (9 to 31). Kaplan-Meier survival using re-intervention for any reason as the endpoint was 91% (95% confidence interval (CI) 68 to 98) and 60% (95% CI 30 to 80) at one and five years, respectively.

There were two revisions for dislocation of the humeral head, one open reduction for modular humeral component dissociation, one internal fixation for nonunion, one trimming of a prominent screw and one re-cementation for aseptic loosening complicated by infection, ultimately requiring excision arthroplasty. Two patients sustained nerve palsies.

Revision TSR after a peri-prosthetic humeral fracture associated with bone loss and/or loose components is a salvage procedure that can provide a stable platform for elbow and hand function. Good rates of union can be achieved using a stem that bypasses the fracture. There is a high rate of complications and function is not as good as with the original replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 10 | Pages 1382 - 1384
1 Oct 2008
Tarantino U Cannata G Gasbarra E Bondi L Celi M Iundusi R

A 20-year-old man sustained an open medial dislocation of the ankle without an associated fracture after a low-energy inversion injury. Prompt debridement and reduction with primary wound closure of the skin were performed without suture of the capsule. Immobilisation in a non-weight-bearing cast for 30 days followed by ankle bracing for two weeks and subsequent physiotherapy, produced full functional recovery by three months. At follow-up at one year there was a full range of pain-free movement, although the radiographs and MR scan showed early post-traumatic degenerative change at the medial aspect of the tibiotalar and the calcaneocuboid joints.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 5 | Pages 574 - 578
1 May 2008
Carroll FA Hoad-Reddick DA Kerry RM Stockley I

Between 1980 and 2000, 63 support rings were used in the management of acetabular deficiency in a series of 60 patients, with a mean follow-up of 8.75 years (2 months to 23.8 years). There was a minimum five-year follow-up for successful reconstructions. The indication for revision surgery was aseptic loosening in 30 cases and infection in 33. All cases were Paprosky III defects; IIIA in 33 patients (52.4%) and IIIB in 30 (47.6%), including four with pelvic dissociation. A total of 26 patients (43.3%) have died since surgery, and 34 (56.7%) remain under clinical review. With acetabular revision for infection or aseptic loosening as the definition of failure, we report success in 53 (84%) of the reconstructions. A total of 12 failures (19%) required further surgery, four (6.3%) for aseptic loosening of the acetabular construct, six (9.5%) for recurrent infection and two (3.2%) for recurrent dislocation requiring captive components. Complications, seen in 11 patients (18.3%), included six femoral or sciatic neuropraxias which all resolved, one grade III heterotopic ossification, one on-table acetabular revision for instability, and three early post-operative dislocations managed by manipulation under anaesthesia, with no further instability.

We recommend support rings and morcellised bone graft for significant acetabular bone deficiency that cannot be reconstructed using mesh.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 327 - 332
1 Mar 2009
García-Rey E García-Cimbrelo E Cordero-Ampuero J

We reviewed 111 hemispherical Duraloc series-500 acetabular components with a minimum follow-up of 12 years. The mean clinical and radiological follow-up was 13.4 years (12 to 15). A Profile hydroxyapatite-coated anatomical femoral component was used in each case. Six patients had a late dislocation, for whom the polyethylene liner was exchanged. Each acetabular component was well fixed and all femoral components showed signs of bone ingrowth. The mean rate of femoral head penetration was 0.10 mm/year (0.021 to 0.481). The probability of not developing femoral cortical hypertrophy and proximal osteopenia by 12 years was 80.2% (95% confidence interval, 72.7 to 87.6) and 77.5% (95% confidence interval, 69.7 to 85.2), respectively. Despite these good clinical results, further follow-up is needed to determine whether these prostheses will loosen with time.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 202 - 208
1 Feb 2010
Berton C Girard J Krantz N Migaud H

Implantation of a large-diameter femoral head prosthesis with a metal-on-metal bearing surface reduces the risk of dislocation, increases the range of movement, minimises the risk of impingement and, in theory, results in little wear.

Between February 2004 and March 2007 we implanted 100 consecutive total hip replacements with a metal-on-metal bearing and a large femoral head into 92 patients. There were 51 men and 41 women with a mean age of 50 years (18 to 70) at the time of surgery.

Outcome was assessed using the Western Ontario McMaster University osteoarthritis index and the Harris hip score as well as the Devane activity score. These all improved significantly (p < 0.0001). At the last follow-up there were no cases of dislocation, no impingement, a good range of movement and no osteolysis, but seven revisions, two for infection and five for aseptic loosening. The probability of groin pain increased if the other acetabular component inclination exceeded 50° (p = 0.0007). At 4.8 years of follow-up, the projected survival of the Durom acetabular component, with revision for any reason, was 92.4% (sd 2.8) (95% confidence interval 89.6 to 95.2).

The design of the component made it difficult both to orientate and seat, which when combined with a poor porous coating, produced unpredictable fixation and a low survival at five years.


The Bone & Joint Journal
Vol. 95-B, Issue 10 | Pages 1320 - 1325
1 Oct 2013
Tamura S Nishii T Takao M Sakai T Yoshikawa H Sugano N

We investigated differences in the location and mode of labral tears between dysplastic hips and hips with femoroacetabular impingement (FAI). We also investigated the relationship between labral tear and adjacent cartilage damage. We retrospectively studied 72 symptomatic hips (in 68 patients: 19 men and 49 women) with radiological evidence of dysplasia or FAI on high-resolution CT arthrography. The incidence and location of labral tears and modes of tear associated with the base of the labrum (Mode 1) or body of the labrum (Mode 2) were compared among FAI, mildly dysplastic and severely dysplastic hips. The locations predominantly involved with labral tears were different in FAI and mild dysplastic hips (anterior and anterosuperior zones) and in severely dysplastic hips (anterosuperior and superior zones) around the acetabulum. Significant differences were observed in the prevalence of Mode 1 versus Mode 2 tears in FAI hips (72% (n = 13) vs 28% (n = 5)) and severe dysplastic hips (25% (n = 2) vs 75% (n = 6)). The frequency of cartilage damage adjacent to Mode 1 tears was significantly higher (42% (n = 14)) than that adjacent to Mode 2 tears (14% (n = 3)).

Hip pathology is significantly related to the locations and modes of labral tears. Mode 1 tears may be a risk factor for the development of adjacent acetabular cartilage damage.

Cite this article: Bone Joint J 2013;95-B:1320–5.


The Bone & Joint Journal
Vol. 95-B, Issue 10 | Pages 1326 - 1331
1 Oct 2013
Eilander W Harris SJ Henkus HE Cobb JP Hogervorst T

Orientation of the acetabular component influences wear, range of movement and the incidence of dislocation after total hip replacement (THR). During surgery, such orientation is often referenced to the anterior pelvic plane (APP), but APP inclination relative to the coronal plane (pelvic tilt) varies substantially between individuals. In contrast, the change in pelvic tilt from supine to standing (dPT) is small for nearly all individuals. Therefore, in THR performed with the patient supine and the patient’s coronal plane parallel to the operating table, we propose that freehand placement of the acetabular component placement is reliable and reflects standing (functional) cup position. We examined this hypothesis in 56 hips in 56 patients (19 men) with a mean age of 61 years (29 to 80) using three-dimensional CT pelvic reconstructions and standing lateral pelvic radiographs. We found a low variability of acetabular component placement, with 46 implants (82%) placed within a combined range of 30° to 50° inclination and 5° to 25° anteversion. Changing from the supine to the standing position (analysed in 47 patients) was associated with an anteversion change < 10° in 45 patients (96%). dPT was < 10° in 41 patients (87%). In conclusion, supine THR appears to provide reliable freehand acetabular component placement. In most patients a small reclination of the pelvis going from supine to standing causes a small increase in anteversion of the acetabular component.

Cite this article: Bone Joint J 2013;95-B:1326–31.


The Bone & Joint Journal
Vol. 97-B, Issue 4 | Pages 478 - 483
1 Apr 2015
Diesel CV Ribeiro TA Coussirat C Scheidt RB Macedo CAS Galia CR

In many papers, the diagnosis of pincer-type femoroacetabular impingement (FAI) is attributed to the presence of coxa profunda. However, little is known about the prevalence of coxa profunda in the general population and its clinical relevance.

In order to ascertain its prevalence in asymptomatic subjects and whether it is a reliable indicator of pincer-type FAI, we undertook a cross-sectional study between July and December 2013. A total of 226 subjects (452 hips) were initially screened. According to strict inclusion criteria, 129 asymptomatic patients (257 hips) were included in the study. The coxa profunda sign, the crossover sign, the acetabular index (AI) and lateral centre–edge (LCE) angle were measured on the radiographs. The median age of the patients was 36.5 years (28 to 50) and 138 (53.7%) were women.

Coxa profunda was present in 199 hips (77.4%). There was a significantly increased prevalence of coxa profunda in women (p < 0.05) and a significant association between coxa profunda and female gender (p < 0.001) (92% vs 60.5%). The crossover sign was seen in 36 hips (14%), an LCE > 40° in 28 hips (10.9%) and an AI < 0º in 79 hips (30.7%). A total of 221 normal hips (79.2%) (normal considering the crossover) had coxa profunda, a total of 229 normal hips (75.5%) (normal considering the LCE) had coxa profunda and a total of 178 normal hips (75.3%) (normal considering AI) had coxa profunda.

When the presence of all radiological signs in the same subject was considered, pincer-type FAI was found in only two hips (one subject). We therefore consider that the coxa profunda sign should not be used as a radiological indicator of pincer-type FAI. We consider profunda to be a benign alteration in the morphology of the hip with low prevalence and a lack of association with other radiological markers of FAI. We suggest that the diagnosis of pincer-type FAI should be based on objective measures, in association with clinical findings.

Cite this article: Bone Joint J 2015; 97-B:478–83.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 4 | Pages 542 - 547
1 Apr 2011
Bonnard C Fournier J Babusiaux D Planchenault M Bergerault F de Courtivron B

This study evaluated the results of a physeal-sparing technique of intra-articular anterior cruciate ligament (ACL) reconstruction in skeletally immature patients, with particular reference to growth disturbance. Between 1992 and 2007, 57 children with a mean age of 12.2 years (6.8 to 14.5) underwent ACL reconstruction using the same technique. At a mean of 5.5 years (2 to 14) after surgery, 56 patients underwent clinical and radiological evaluation. At that time, 49 patients (87.5%) had reached bony maturity and 53 (95%) achieved A or B according to the IKDC 2000 classification. Four patients had stopped participation in sports because of knee symptoms, and three patients (5.4%) had a subsequent recurrent ACL injury. There was no clinical or radiological evidence of growth disturbance after a mean growth in stature of 20.0 cm (3 to 38).

This study demonstrates that ACL reconstruction sparing the physes in children is a safe technique protecting against meniscal tears and giving better results than reconstruction in adults, without causing significant growth disturbance.


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 664 - 667
1 May 2013
Rashid A Christofi T Thomas M

Lateral clavicular physeal injuries in adolescents are frequently misinterpreted as acromioclavicular dislocations. There are currently no clear guidelines for the management of these relatively rare injuries. Non-operative treatment can result in a cosmetic deformity, warranting resection of the non-remodelled original lateral clavicle. However, fixation with Kirschner (K)-wires may be associated with infection and/or prominent metalwork. We report our experience with a small series of such cases.

Between October 2008 and October 2011 five patients with lateral clavicular physeal fractures (types III, IV and V) presented to our unit. There were four boys and one girl with a mean age of 12.8 years (9 to 14). Four fractures were significantly displaced and treated operatively using a tension band suture technique. One grade III fracture was treated conservatively. The mean follow-up was 26 months (6 to 42).

All patients made an uncomplicated recovery. The mean time to discharge was three months. The QuickDASH score at follow-up was 0 for each patient. No patient developed subsequent growth disturbances.

We advocate the surgical treatment of significantly displaced Grade IV and V fractures to avoid cosmetic deformity. A tension band suture technique avoids the problems of retained metalwork and the need for a secondary procedure. Excellent clinical and radiological results were seen in all our patients.

Cite this article: Bone Joint J 2013;95-B:664–7.


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 881 - 886
1 Jul 2013
Bjorgul K Novicoff WN Andersen ST Ahlund OR Bunes A Wiig M Brevig K

A total of 397 hips were randomised to receive Metasul metal-on-metal (MoM), metal-on-conventional polyethylene (MoP) or ceramic-on-polyethylene (CoP) bearings using a cemented triple-tapered polished femoral component (MS-30). There were 129 MoM hips in 123 patients (39 male and 84 female, mean age 63.3 years (40.7 to 72.9)), 137 MoP hips in 127 patients (39 male and 88 female, mean age 62.8 years (24.5 to 72.7)) and 131 CoP hips in 124 patients (51 male and 73 female, mean age 63.9 years (30.6 to 73.8)). All acetabular components were cemented Weber polyethylene components with the appropriate inlay for the MoM articulation. Clinical evaluation was undertaken using the Harris hip score (HHS) and radiological assessments were made at two, five and seven years. The HHS and radiological analysis were available for 341 hips after seven years. The MoM group had the lowest mean HHS (p = 0.124), a higher rate of revision (p < 0.001) and a higher incidence of radiolucent lines in unrevised hips (p < 0.001). In all, 12 revisions had been performed in 12 patients: eight in the MoM group (four for infection, four for aseptic loosening, three in the MoP group (one each of infection, dislocation and pain) and one in the CoP group (infection).

Our findings reveal no advantage to the MoM bearing and identified a higher revision rate and a greater incidence of radiolucent lines than with the other articulations. We recommend that patients with a 28 mm Metasul MoM bearing be followed carefully.

Cite this article: Bone Joint J 2013;95-B:881–6.


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1134 - 1138
1 Aug 2013
Hsu C Shih C Wang C Huang K

Although the importance of lateral femoral wall integrity is increasingly being recognised in the treatment of intertrochanteric fracture, little attention has been put on the development of a secondary post-operative fracture of the lateral wall. Patients with post-operative fractures of the lateral wall were reported to have high rates of re-operation and complication. To date, no predictors of post-operative lateral wall fracture have been reported. In this study, we investigated the reliability of lateral wall thickness as a predictor of lateral wall fracture after dynamic hip screw (DHS) implantation.

A total of 208 patients with AO/OTA 31-A1 and -A2 classified intertrochanteric fractures who received internal fixation with a DHS between January 2003 and May 2012 were reviewed. There were 103 men and 150 women with a mean age at operation of 78 years (33 to 94). The mean follow-up was 23 months (6 to 83). The right side was affected in 97 patients and the left side in 111. Clinical information including age, gender, side, fracture classification, tip–apex distance, follow-up time, lateral wall thickness and outcome were recorded and used in the statistical analysis.

Fracture classification and lateral wall thickness significantly contributed to post-operative lateral wall fracture (both p < 0.001). The lateral wall thickness threshold value for risk of developing a secondary lateral wall fracture was found to be 20.5 mm.

To our knowledge, this is the first study to investigate the risk factors of post-operative lateral wall fracture in intertrochanteric fracture. We found that lateral wall thickness was a reliable predictor of post-operative lateral wall fracture and conclude that intertrochanteric fractures with a lateral wall thickness < 20.5 mm should not be treated with DHS alone.

Cite this article: Bone Joint J 2013;95-B:1134–8.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1615 - 1619
1 Dec 2007
Piskin A Tomak Y Sen C Tomak L

Cubitus varus and valgus are the most common complications of supracondylar and lateral condylar fractures. Various combinations of osteotomy and fixation have been described to correct these deformities but each is associated with significant complications. In this study, we used distraction osteogenesis and Ilizarov frame fixation to treat 24 elbows in 23 patients with cubitus varus or valgus. Their clinical outcome was evaluated using the protocol of Bellemore et al. The mean time to follow-up was 18.3 months (10 to 36) and the mean time to frame removal was 13.5 weeks (8 to 20). The mean carrying angle was corrected from −18.7° (−10° to −30°) to 6.1° (2° to 10°) in patients with cubitus varus and from 36.5° (25° to 45°) to 9.4° (4° to 15°) in patients with cubitus valgus. There were 18 excellent and six good results.

The Ilizarov method with gradual distraction is a safe, stable, adjustable and versatile method of treating deformities at the elbow without the problems of an unsightly scar or limited range of movement, and gives a good clinical and radiological outcome. Tardy ulnar nerve palsy should be treated first by anterior transposition.


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1603 - 1609
1 Dec 2013
Chana R Facek M Tilley S Walter WK Zicat B Walter WL

We report the clinical and radiological outcomes of a series of contemporary cementless ceramic-on-ceramic total hip replacements (THRs) at ten years in patients aged ≤ 55 years of age. Pre- and post-operative activity levels are described. A total of 120 consecutive ceramic cementless THRs were performed at a single centre in 110 patients from 1997 to 1999. The mean age of the patients at operation was 45 years (20 to 55). At ten years, four patients had died and six were lost to follow-up, comprising ten hips. The mean post-operative Harris hip score was 94.7 (55 to 100). Radiological analysis was undertaken in 90 available THRs of the surviving 106 hips at final review: all had evidence of stable bony ingrowth, with no cases of osteolysis. Wear was undetectable. There were four revisions. The survival for both components with revision for any cause as an endpoint was 96.5% (95% confidence interval 94.5 to 98.7). The mean modified University of California, Los Angeles activity level rose from a mean of 6.4 (4 to 10) pre-operatively to 9.0 (6 to 10) at the ten-year post-operative period.

Alumina ceramic-on-ceramic bearings in cementless primary THR in this series have resulted in good clinical and radiological outcomes with undetectable rates of wear and excellent function in the demanding younger patient group at ten years.

Cite this article: Bone Joint J 2013;95-B:1603–9.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 3 | Pages 304 - 309
1 Mar 2006
Macheras GA Papagelopoulos PJ Kateros K Kostakos AT Baltas D Karachalios TS

Between January 1998 and December 1998, 82 consecutive patients (86 hips) underwent total hip arthroplasty using a trabecular metal monoblock acetabular component. All patients had a clinical and radiological follow-up evaluation at six, 12 and 24 weeks, 12 months, and then annually thereafter. On the initial post-operative radiograph 25 hips had a gap between the outer surface of the component and the acetabular host bed which ranged from 1 to 5 mm. All patients were followed up clinically and radiologically for a mean of 7.3 years (7 to 7.5). The 25 hips with the 1 to 5 mm gaps were studied for component migration at two years using the Einzel-Bild-Roentgen-Analyse (EBRA) digital measurement method. At 24 weeks all the post-operative gaps were filled with bone and no acetabular component had migrated. The radiographic outcome of all 86 components showed no radiolucent lines and no evidence of lysis. No acetabular implant was revised. There were no dislocations or other complications. The bridging of the interface gaps (up to 5 mm) by the trabecular metal monoblock acetabular component indicates the strong osteoconductive, and possibly osteoinductive, properties of trabecular metal.


The Bone & Joint Journal
Vol. 95-B, Issue 10 | Pages 1410 - 1416
1 Oct 2013
Gebert C Wessling M Gosheger G Aach M Streitbürger A Henrichs MP Dirksen U Hardes J

To date, all surgical techniques used for reconstruction of the pelvic ring following supra-acetabular tumour resection produce high complication rates. We evaluated the clinical, oncological and functional outcomes of a cohort of 35 patients (15 men and 20 women), including 21 Ewing’s sarcomas, six chondrosarcomas, three sarcomas not otherwise specified, one osteosarcoma, two osseous malignant fibrous histiocytomas, one synovial cell sarcoma and one metastasis. The mean age of the patients was 31 years (8 to 79) and the latest follow-up was carried out at a mean of 46 months (1.9 to 139.5) post-operatively.

We undertook a functional reconstruction of the pelvic ring using polyaxial screws and titanium rods. In 31 patients (89%) the construct was encased in antibiotic-impregnated polymethylmethacrylate. Preservation of the extremities was possible for all patients. The survival rate at three years was 93.9% (95% confidence interval (CI) 77.9 to 98.4), at five years it was 82.4% (95% CI 57.6 to 93.4). For the 21 patients with Ewing’s sarcoma it was 95.2% (95% CI 70.7 to 99.3) and 81.5% (95% CI 52.0 to 93.8), respectively. Wound healing problems were observed in eight patients, deep infection in five and clinically asymptomatic breakage of the screws in six. The five-year implant survival was 93.3% (95% CI 57.8 to 95.7). Patients were mobilised at a mean of 3.5 weeks (1 to 7) post-operatively. A post-operative neurological defect occurred in 12 patients. The mean Musculoskeletal Tumor Society score at last available follow-up was 21.2 (10 to 27).

This reconstruction technique is characterised by simple and oncologically appropriate applicability, achieving high primary stability that allows early mobilisation, good functional results and relatively low complication rates.

Cite this article: Bone Joint J 2013;95-B:1410–16.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 4 | Pages 449 - 455
1 Apr 2011
Kim Y Kim J Park J Joo J

There have been comparatively few studies of the incidence of osteolysis and the survival of hybrid and cementless total hip replacements (THRs) in patients younger than 50 years of age. We prospectively reviewed 78 patients (109 hips) with a hybrid THR having a mean age of 43.4 years (21 to 50) and 79 patients (110 hips) with a cementless THR with a mean age of 46.8 years (21 to 49). The patients were evaluated clinically using the Harris hip score, the Western Ontario and McMaster Universities (WOMAC) osteoarthritis score and the University of California, Los Angeles (UCLA) activity score. Radiographs and CT scans were assessed for loosening and osteolysis. The mean follow-up was for 18.4 years (16 to 19) in both groups.

The mean post-operative Harris hip scores (91 points versus 90 points), the mean WOMAC scores (11 points versus 13 points) and UCLA activity scores (6.9 points versus 7.1 points) were similar in both groups. The revision rates of the acetabular component (13% versus 16%) and the femoral component (3% versus 4%), and the survival of the acetabular component (87% versus 84%) and the femoral component (97% versus 96%) were similar in both groups.

Although the long-term fixation of the acetabular metallic shell and the cemented and cementless femoral components was outstanding, wear and peri-acetabular osteolysis constitute the major challenges of THR in young patients.