Advertisement for orthosearch.org.uk
Results 501 - 520 of 1732
Results per page:
Bone & Joint 360
Vol. 1, Issue 2 | Pages 18 - 19
1 Apr 2012

The April 2012 Foot & Ankle Roundup. 360 . looks at injecting the tendon sheath, total ankle replacement, heterotopic ossification, replacement or arthrodesis, achilles tendinopathy, healing of the torn Achilles, grafting of the calcaneal bone cyst, avulsion fractures in athletes, percutaneous distal osteotomy for bunionette formation, and repairing the torn tibiofibular syndesmosis


Bone & Joint 360
Vol. 9, Issue 5 | Pages 24 - 28
1 Oct 2020


The Journal of Bone & Joint Surgery British Volume
Vol. 42-B, Issue 2 | Pages 360 - 366
1 May 1960
Nisbet NW

1. Certain macroscopical and microscopical features of the tendo calcaneus of the rabbit are described and illustrated, and the vascularisation as revealed by Spalteholz clearing is presented. 2. The vessels of the epitenon are chiefly derived from proximal and distal sources. 3. The vessels of the paratenon are derived from the main arteries of the leg. 4. The two vascular systems are largely independent of each other except along one edge of the tendon by way of a mesotenon. 5. The paratenon, epitenon and mesotenon and the related vessels are comparable to those found in tendons with synovial sheaths. By inference and from evidence obtained by dissection on the living human subject it is suggested that the arrangements are similar in the human tendo calcaneus. 6. Considerable friction develops on movement between the surfaces of the paratenon and epitenon. This might be significant in pathological states of the human tendon


Bone & Joint 360
Vol. 9, Issue 6 | Pages 27 - 30
1 Dec 2020


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 4 | Pages 640 - 644
1 Aug 1985
Atkins R Bell M Sharrard W

Seven pectoralis major transfers in children suffering from bilateral paralysis of elbow flexion due to arthrogryposis or to trauma are reported. A technique is described in which the muscle is mobilised from the clavicle to allow the tendon of insertion to be attached to the biceps tendon at the elbow. The biceps tendon was found to be present and could be mobilised forwards in all the arthrogrypotic elbows. Subjectively, the results were considered by patients or parents to be very good in six cases and fair in one. Elbow flexion power against gravity and against some resistance was achieved in all patients except one. The overall function was very good in one elbow, good in two, fair in three and poor in only one. The merits of the various procedures described for the restoration of elbow flexion in arthrogryposis are discussed. It is concluded that total pectoralis major transfer by the method described here has given the best results


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 384 - 390
1 Mar 2013
Stevenson JD Jaiswal A Gregory JJ Mangham DC Cribb G Cool P

Pigmented villonodular synovitis (PVNS) is a rare benign disease of the synovium of joints and tendon sheaths, which may be locally aggressive. We present 18 patients with diffuse-type PVNS of the foot and ankle followed for a mean of 5.1 years (2 to 11.8). There were seven men and 11 women, with a mean age of 42 years (18 to 73). A total of 13 patients underwent open or arthroscopic synovectomy, without post-operative radiotherapy. One had surgery at the referring unit before presentation with residual tibiotalar PVNS. The four patients who were managed non-operatively remain symptomatically controlled and under clinical and radiological surveillance. At final follow-up the mean Musculoskeletal Tumour Society score was 93.8% (95% confidence interval (CI) 85 to 100), the mean Toronto Extremity Salvage Score was 92 (95% CI 82 to 100) and the mean American Academy of Orthopaedic Surgeons foot and ankle score was 89 (95% CI 79 to 100). The lesion in the patient with residual PVNS resolved radiologically without further intervention six years after surgery. Targeted synovectomy without adjuvant radiotherapy can result in excellent outcomes, without recurrence. Asymptomatic patients can be successfully managed non-operatively. This is the first series to report clinical outcome scores for patients with diffuse-type PVNS of the foot and ankle. Cite this article: Bone Joint J 2013;95-B:384–90


Bone & Joint 360
Vol. 10, Issue 2 | Pages 33 - 37
1 Apr 2021


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 711 - 717
1 Apr 2021
Feitz R van der Oest MJW van der Heijden EPA Slijper HP Selles RW Hovius SER

Aims

Patients with a triangular fibrocartilage complex (TFCC) injury report ulnar-sided wrist pain and impaired function. The surgical procedure of TFCC reinsertion aims to improve function in patients with this injury in whom conservative treatment has failed. The purpose of this study was to investigate the outcomes of open TFCC reinsertion.

Methods

The study involved 274 patients who underwent open repair of the TFCC between December 2013 and December 2018. The patients completed the Patient-Rated Wrist Evaluation (PRWE) questionnaire, and scored pain and function using a visual analogue scale (VAS). Range of motion (ROM) was assessed by experienced hand therapists.


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 718 - 724
1 Apr 2021
Cavalier M Johnston TR Tran L Gauci M Boileau P

Aims

The aim of this study was to identify risk factors for recurrent instability of the shoulder and assess the ability to return to sport in patients with engaging Hill-Sachs lesions treated with arthroscopic Bankart repair and Hill-Sachs remplissage (ABR-HSR).

Methods

This retrospective study included 133 consecutive patients with a mean age of 30 years (14 to 69) who underwent ABR-HSR; 103 (77%) practiced sports before the instability of the shoulder. All had large/deep, engaging Hill-Sachs lesions (Calandra III). Patients were divided into two groups: A (n = 102) with minimal or no (< 10%) glenoid bone loss, and B (n = 31) with subcritical (10% to 20%) glenoid loss. A total of 19 patients (14%) had undergone a previous stabilization, which failed. The primary endpoint was recurrent instability, with a secondary outcome of the ability to return to sport.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 7 | Pages 1072 - 1076
1 Sep 2004
Tien Y Chih T Lin JC Ju C Lin S

The healing of a hamstring graft to bone is the weak link in the reconstruction of a cruciate ligament using this donor material. We therefore investigated the augmentation of healing at the tendon-bone interface using calcium-phosphate cement (CPC). We performed semitendinosus autograft reconstructions of the anterior cruciate ligament on both knees of 22 New Zealand white rabbits. The interface between the grafted tendon and the bone tunnel for one knee was filled with CPC. Six rabbits were killed at the end of the first and second post-operative weeks in order to evaluate the biomechanical changes. Two rabbits were then killed sequentially at the end of weeks 1, 3, 6, 12 and 24 after operation and tissue removed for serial histological observation. Histological examination showed that the use of CPC produced early, diffuse and massive bone ingrowth. By contrast, in the non-CPC group of rabbits only a thin layer of new bone was seen. Mechanical pull-out testing at one week showed that the mean maximal tensile strength was 6.505 ± 1.333 N for the CPC group and 2.048 ± 0.950 N for the non-CPC group. At two weeks the values were 11.491 ± 2.865 N and 5.452 ± 3.955 N, respectively. Our findings indicate that CPC is a potentially promising material in clinical practice as regards its ability to reinforce the fixation of the tendon attachment to bone and to augment the overall effectiveness of tendon healing to bone


Cite this article: Bone Joint Open 2020;1-11:706–708.


Bone & Joint 360
Vol. 9, Issue 5 | Pages 28 - 32
1 Oct 2020


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 2 | Pages 271 - 276
1 Mar 1991
Kurer M Baillod R Madgwick J

Long-term regular haemodialysis for chronic renal failure is associated with amyloidosis. In this condition excess amounts of the unexcretable plasma protein beta-microglobulin are laid down in tendons, joints and bones. Amyloidosis presents with various musculoskeletal disorders only after several years of dialysis. We reviewed 83 patients who had been dialysed for at least 10 years. The commonest complaint was severe joint pain in the absence of radiological changes of arthritis (41%), the shoulders usually being the most affected (33%). Carpal tunnel syndrome had developed in 26 patients, and was bilateral in 14 of them; at operation the presence of amyloid was confirmed. Six of these patients had recurrent symptoms after a further two to three years and required another decompression. Other manifestations of amyloidosis included trigger finger, flexor tendon contracture, spontaneous tendon rupture and pathological fracture through amyloid bone cysts. The frequency of symptoms was proportional to the duration of dialysis: all 13 patients on dialysis for over 20 years were affected. Symptoms developed earlier in older patients


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 8 | Pages 1001 - 1009
1 Aug 2007
Ahrens PM Boileau P

This paper describes the current views on the pathology of lesions of the tendon of the long head of biceps and their management. Their diagnosis is described and their surgical management classified, with details of the techniques employed


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 3 | Pages 546 - 552
1 May 1998
Rompe JD Kirkpatrick CJ Küllmer K Schwitalle M Krischek O

We aimed to determine whether extracorporeal shock waves of varying intensity would damage the intact tendo Achillis and paratenon in a rabbit model. We used 42 female New Zealand white rabbits randomly divided into four groups as follows: group a received 1000 shock-wave impulses of an energy flux density of 0.08 mJ/mm. 2. , group b 1000 impulses of 0.28 mJ/mm. 2. , group c 1000 impulses of 0.60 mJ/mm. 2. , and group d was a control group. Sonographic and histological evaluation showed no changes in group a, and transient swelling of the tendon with a minor inflammatory reaction in group b. Group c had formation of paratendinous fluid with a significant increase in the anteroposterior diameter of the tendon. In this group there were marked histological changes with increased eosin staining, fibrinoid necrosis, fibrosis in the paratenon and infiltration of inflammatory cells. We conclude that there are dose-dependent changes in the tendon and paratenon after extracorporeal shock-wave therapy and that energy flux densities of over 0.28 mJ/mm. 2. should not be used clinically in the treatment of tendon disorders


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 2 | Pages 250 - 254
1 Mar 2000
Breusch SJ Wenz W Döderlein L

We carried out a cross-sectional study in 51 patients (81 feet) with a clawed hallux in association with a cavus foot after a modified Robert Jones tendon transfer. The mean follow-up was 42 months (9 to 88). In all feet, concomitant procedures had been undertaken, such as extension osteotomy of the first metatarsal and transfer of the tendon of the peroneus longus to peroneus brevis, to correct the underlying foot deformity. All patients were evaluated clinically and radiologically. The overall rate of patient satisfaction was 86%. The deformity of the hallux was corrected in 80 feet. Catching of the big toe when walking barefoot, transfer lesions and metatarsalgia, hallux flexus, hallux limitus and asymptomatic nonunion of the interphalangeal joint were the most frequent complications. Hallux limitus was more likely when elevation of the first ray occurred (p = 0.012). Additional transfer of the tendon of peroneus longus to peroneus brevis was a significant risk factor for elevation of the first metatarsal (p < 0.0001). The deforming force of extensor hallucis longus is effectively eliminated by the Jones transfer, but the mechanics of the first metatarsophalangeal joint are altered. The muscle balance and stability of the entire first ray should be taken into consideration in the management of clawed hallux


Bone & Joint Open
Vol. 2, Issue 3 | Pages 174 - 180
17 Mar 2021
Wu DY Lam EKF

Aims

The purpose of this study is to examine the adductus impact on the second metatarsal by the nonosteotomy nonarthrodesis syndesmosis procedure for the hallux valgus deformity correction, and how it would affect the mechanical function of the forefoot in walking. For correcting the metatarsus primus varus deformity of hallux valgus feet, the syndesmosis procedure binds first metatarsal to the second metatarsal with intermetatarsal cerclage sutures.

Methods

We reviewed clinical records of a single surgical practice from its entire 2014 calendar year. In total, 71 patients (121 surgical feet) qualified for the study with a mean follow-up of 20.3 months (SD 6.2). We measured their metatarsus adductus angle with the Sgarlato’s method (SMAA), and the intermetatarsal angle (IMA) and metatarsophalangeal angle (MPA) with Hardy’s mid axial method. We also assessed their American Orthopaedic Foot & Ankle Society (AOFAS) clinical scale score, and photographic and pedobarographic images for clinical function results.


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1101 - 1105
1 Aug 2013
Haug LC Glodny B Deml C Lutz M Attal R

Penetration of the dorsal screw when treating distal radius fractures with volar locking plates is an avoidable complication that causes lesions of the extensor tendon in between 2% and 6% of patients. We examined axial fluoroscopic views of the distal end of the radius to observe small amounts of dorsal screw penetration, and determined the ideal angle of inclination of the x-ray beam to the forearm when making this radiological view. Six volar locking plates were inserted at the wrists of cadavers. The actual screw length was measured under direct vision through a dorsal approach to the distal radius. Axial radiographs were performed for different angles of inclination of the forearm at the elbow. Comparing axial radiological measurements and real screw length, a statistically significant correlation could be demonstrated at an angle of inclination between 5° and 20°. The ideal angle of inclination required to minimise the risk of implanting over-long screws in a dorsal horizon radiological view is 15°. Cite this article: Bone Joint J 2013;95-B:1101–5


The Journal of Bone & Joint Surgery British Volume
Vol. 44-B, Issue 4 | Pages 964 - 964
1 Nov 1962

Professor Paul Brand draws attention to an error in the report of a meeting of the Orthopaedic Section of the Association of Surgeons of India submitted to this journal and published in our issue of May 1962. The observations then reported were not made by him but in his absence by another contributor. The particular paragraph to which Professor Brand wishes to draw attention read: "Lately he had been using a wrist flexor tendon as the motor unit for the transplant, instead of the extensor carpi ulnaris, and he felt that the flexor tendon was the better.". Professor Brand writes: "I have not been using a wrist flexor tendon as the motor unit. I used one many years ago, and found it is very definitely inferior. I have never used the extensor carpi ulnaris. I assume that the sentence should have read: ‘Lately he has been using the extensor carpi radialis longus as the motor unit for the transplant instead of the extensor carpi radialis brevis, and has taken the graft around the radial side of the forearm and through the carpal tunnel to reach the lumbrical insertions along the lumbrical canals. He found the results were better with this method.’"


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 11 | Pages 1503 - 1507
1 Nov 2011
Maffulli N Del Buono A Testa V Capasso G Oliva F Denaro V

This is a prospective analysis on 30 physically active individuals with a mean age of 48.9 years (35 to 64) with chronic insertional tendinopathy of the tendo Achillis. Using a transverse incision, the tendon was debrided and an osteotomy of the posterosuperior corner of the calcaneus was performed in all patients. At a minimum post-operative follow-up of three years, the Victorian Institute of Sports Assessment scale – Achilles tendon scores were significantly improved compared to the baseline status. In two patients a superficial infection of the wound developed which resolved on antibiotics. There were no other wound complications, no nerve related complications, and no secondary avulsions of the tendo Achillis. In all, 26 patients had returned to their pre-injury level of activity and the remaining four modified their sporting activity. At the last appointment, the mean pain threshold and the mean post-operative tenderness were also significantly improved from the baseline (p < 0.001). In patients with insertional tendo Achillis a transverse incision allows a wide exposure and adequate debridement of the tendo Achillis insertion, less soft-tissue injury from aggressive retraction and a safe osteotomy of the posterosuperior corner of the calcaneum