1 Dec 2019
Wang J Ma H Chou TA Tsai S Chen C Wu P Chen W

Aims

The aim of this meta-analysis was to compare the outcome of total elbow arthroplasty (TEA) undertaken for rheumatoid arthritis (RA) with TEA performed for post-traumatic conditions with regard to implant failure, functional outcome, and perioperative complications.

Materials and Methods

We completed a comprehensive literature search on PubMed, Web of Science, Embase, and the Cochrane Library and conducted a systematic review and meta-analysis. Nine cohort studies investigated the outcome of TEA between RA and post-traumatic conditions. The preferred reporting items for systematic reviews and meta-analysis (Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA)) guidelines and Newcastle-Ottawa scale were applied to assess the quality of the included studies. We assessed three major outcome domains: implant failures (including aseptic loosening, septic loosening, bushing wear, axle failure, component disassembly, or component fracture); functional outcomes (including arc of range of movement, Mayo Elbow Performance Score (MEPS), and the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire), and perioperative complications (including deep infection, intraoperative fracture, postoperative fracture, and ulnar neuropathy).


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1177 - 1178
1 Oct 2019
Troelsen A Haddad FS


Bone & Joint 360
Vol. 9, Issue 1 | Pages 35 - 39
1 Feb 2020


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 9 | Pages 1154 - 1157
1 Sep 2009
White SP John AW Jones SA

Between December 2004 and June 2006, 136 patients (156 total hip replacements), were sent from the waiting list of the Cardiff Vale NHS Trust to the NHS Treatment Centre, Weston-super-Mare, in an attempt to reduce the waiting time for total hip replacement. Because of concerns about their outcome, each patient was contacted and invited to attend a review appointment with a consultant specialising in hip and revision hip replacement. A total of 98 patients (113 hips) were reviewed after a mean of 23 months (11 to 30). There were 104 cemented hips, seven hybrid and two cementless. An acetabular inclination of > 55° was seen in 18 (16%). Radiolucent lines around the acetabular component were seen in 76 (67%). The femoral component was in more than 4° of varus in 47 (42%). The medial floor had been breached in 13 (12%) and there was a leg-length discrepancy of more than 1 cm in ten (9%). There were three dislocations, one femoral fracture, one pulmonary embolus, one deep infection and two superficial wound infections. To date, 13% (15 hips) have been revised and a further 4% (five hips) await revision, mostly for a painful loose acetabular component. The revision rate far exceeds the 0.5% five-year failure rate reported in the Swedish Registry for the components used. This initiative and the consequent need for correction of the problems created, has significantly increased the workload of our unit


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 4 | Pages 424 - 429
1 Apr 2008
Andrew JG Palan J Kurup HV Gibson P Murray DW Beard DJ

A prospective, multi-centre study was carried out on 1421 total hip replacements between January 1999 and July 2007 to examine if obesity has an effect on clinical outcomes. The patients were categorised into three groups: non-obese (body mass index (BMI) < 30 kg/m. 2. ), obese (BMI 30 to 40 kg/m. 2. ) and morbidly obese (BMI > 40 kg/m. 2. ). The primary outcome measure was the change in Oxford hip score at five years. Secondary outcome measures included dislocation and revision rates, increased haemorrhage, deep infection, deep-vein thrombosis and pulmonary embolism, mean operating time and length of hospital stay. Radiological analysis assessing heterotopic ossification, femoral osteolysis and femoral stem positioning was performed. Data were incomplete for 362 hips (25.5%). There was no difference in the change in the Oxford hip score, complication rates or radiological changes at five years between the groups. The morbidly obese group was significantly younger and required a significantly longer operating time. Obese and morbidly obese patients have as much to gain from total hip replacement as non-obese patients


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1248 - 1255
1 Oct 2019
Pineda A Pabbruwe MB Kop AM Vlaskovsky P Hurworth M

Aims

The aim of this study was to conduct the largest low contact stress (LCS) retrieval study to elucidate the failure mechanisms of the Porocoat and Duofix femoral component. The latter design was voluntarily recalled by the manufacturer.

Materials and Methods

Uncemented LCS explants were divided into three groups: Duofix, Porocoat, and mixed. Demographics, polyethylene wear, tissue ingrowth, and metallurgical analyses were performed.


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 838 - 847
1 Jul 2019
Robinson PG Clement ND Hamilton D Blyth MJG Haddad FS Patton JT

Aims

Robotic-assisted unicompartmental knee arthroplasty (UKA) promises accurate implant placement with the potential of improved survival and functional outcomes. The aim of this study was to present the current evidence for robotic-assisted UKA and describe the outcome in terms of implant positioning, range of movement (ROM), function and survival, and the types of robot and implants that are currently used.

Materials and Methods

A search of PubMed and Medline was performed in October 2018 in line with the Preferred Reporting Items for Systematic Review and Meta-Analysis statement. Search terms included “robotic”, “knee”, and “surgery”. The criteria for inclusion was any study describing the use of robotic UKA and reporting implant positioning, ROM, function, and survival for clinical, cadaveric, or dry bone studies.


Bone & Joint 360
Vol. 8, Issue 4 | Pages 19 - 21
1 Aug 2019


Bone & Joint 360
Vol. 8, Issue 4 | Pages 16 - 19
1 Aug 2019


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 6 | Pages 871 - 874
1 Aug 2003
Morgan-Hough CVJ Jones PW Eisenstein SM

We present a review of 553 patients who underwent surgery for intractable sciatica ascribed to prolapsed lumbar intervertebral disc. One surgeon in one institution undertook or supervised all the operations over a period of 16 years. The total number of primary discectomies included in the study was 531, of which 42 subsequently required a second operation for recurrent sciatica, giving a revision rate of 7.9%. Factors associated with reoperation were analysed. A contained disc protrusion was almost three times more likely to need revision surgery, compared with extruded or sequestrated discs. Patients with primary protrusions had a significantly greater straight-leg raise and reduced incidence of positive neurological findings compared with those with extruded or sequestrated discs. These patients should therefore be selected out clinically and treated by a more enthusiastic conservative programme, since they are three times more likely to require revision surgery


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1063 - 1070
1 Sep 2019
Clement ND Deehan DJ Patton JT

Aims

The primary aim of the study was to perform an analysis to identify the cost per quality-adjusted life-year (QALY) of robot-assisted unicompartmental knee arthroplasty (rUKA) relative to manual total knee arthroplasty (TKA) and unicompartmental knee arthroplasty (UKA) for patients with isolated medial compartment osteoarthritis (OA) of the knee. Secondary aims were to assess how case volume and length of hospital stay influenced the relative cost per QALY.

Patients and Methods

A Markov decision analysis was performed, using known parameters for costs, outcomes, implant survival, and mortality, to assess the cost-effectiveness of rUKA relative to manual TKA and UKA for patients with isolated medial compartment OA of the knee with a mean age of 65 years. The influence of case volume and shorter hospital stay were assessed.


Bone & Joint 360
Vol. 8, Issue 5 | Pages 14 - 16
1 Oct 2019


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 90 - 101
1 Jan 2020
Davis ET Pagkalos J Kopjar B

Aims

The aim of this study was to identify the effect of the manufacturing characteristics of polyethylene acetabular liners on the survival of cementless and hybrid total hip arthroplasty (THA).

Methods

Prospective cohort study using linked National Joint Registry (NJR) and manufacturer data. The primary endpoint was revision for aseptic loosening. Cox proportional hazard regression was the primary analytical approach. Manufacturing variables included resin type, crosslinking radiation dose, terminal sterilization method, terminal sterilization radiation dose, stabilization treatment, total radiation dose, packaging, and face asymmetry. Total radiation dose was further divided into G1 (no radiation), G2 (> 0 Mrad to < 5 Mrad), G3 (≥ 5 Mrad to < 10 Mrad), and G4 (≥ 10 Mrad).


Bone & Joint Research
Vol. 8, Issue 12 | Pages 604 - 607
1 Dec 2019
Konan S Abdel MP Haddad FS

There is continued debate as to whether cemented or cementless implants should be utilized in particular cases based upon chronological age. This debate has been rekindled in the UK and other countries by directives mandating certain forms of acetabular and femoral component fixation based exclusively on the chronological age of the patient. This editorial focuses on the literature-based arguments to support the use of cementless total hip arthroplasty (THA), while addressing potential concerns surrounding safety and cost-effectiveness.

Cite this article: Bone Joint Res. 2019;8(12):604–607.


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 1 | Pages 56 - 62
1 Jan 1988
Johnsson R Thorngren K Persson B

During the 11-year-period from 1970 to 1980, 799 total hip arthroplasties with metal-on-plastic prostheses were performed for primary osteoarthritis. In all cases high viscosity cement was used, but not under pressure; acetabular cartilage was removed, but the femoral canal was not plugged. The rate of revision and risk factors were evaluated by survivorship analysis. The overall cumulative revision rates were 11%, 14% and 19% after 8, 10, and 14 years respectively. When prophylactic antibiotics were not used, there was a significant risk of revision for infection. The risk of revision for mechanical loosening of both the acetabular and femoral components was significantly increased for men, younger patients, and if a snap-fit prosthesis with a 35 mm head and short wedged stem was used. The survivorship findings were validated by multivariate statistical analysis


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 1 | Pages 40 - 44
1 Jan 1988
Nunn D

The Ring plastic-on-metal total hip replacement was introduced with the intention of combining the advantages of the cemented low-friction arthroplasty with those of a cementless system. Fourteen hundred and eighty-eight of these procedures have been reviewed. The results of a two to seven-year follow-up, and of a group which has completed at least five years are presented. There was an excellent clinical result in 93% of the whole series, and in 87% of the five-year group. When graded on the Charnley scale there was an average score of 5.86 for pain, 5.96 for function and 5.9 for range of movement, which compares favourably with cemented replacements. The deep infection rate was zero, and the revision rate 1.5% for the whole series. Erosive problems occurred with the smaller acetabular components and the reasons are discussed. The ease and success of exchange have been maintained


Bone & Joint 360
Vol. 8, Issue 6 | Pages 20 - 22
1 Dec 2019


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1199 - 1208
1 Oct 2019
Lamb JN Matharu GS Redmond A Judge A West RM Pandit HG

Aims

We compared implant and patient survival following intraoperative periprosthetic femoral fractures (IOPFFs) during primary total hip arthroplasty (THA) with matched controls.

Patients and Methods

This retrospective cohort study compared 4831 hips with IOPFF and 48 154 propensity score matched primary THAs without IOPFF implanted between 2004 and 2016, which had been recorded on a national joint registry. Implant and patient survival rates were compared between groups using Cox regression.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 1 | Pages 45 - 49
1 Jan 2001
Robertsson O Knutson K Lewold S Lidgren L

A total of 10474 unicompartmental knee arthroplasties was performed for medial osteoarthritis in Sweden between 1986 and 1995. We sought to establish whether the number of operations performed in an orthopaedic unit affected the incidence of revision. Three different implants were analysed: one with a high revision rate, known to have unfavourable mechanical and design properties; a prosthesis which is technically demanding with a known increased rate of revision; and the most commonly used unicompartmental device. Most of the units performed relatively few unicompartmental knee arthroplasties per year and there was an association between the mean number carried out and the risk of later revision. The effect of the mean number of operations per year on the risk of revision varied. The technically demanding implant was most affected, that most commonly used less so, and the outcome of the unfavourable design was not influenced by the number of operations performed. For unicompartmental arthroplasty, the long-term results are related to the number performed by the unit, probably expressing the standards of management in selecting the patients and performing the operation