Advertisement for orthosearch.org.uk
Results 481 - 500 of 1075
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 1 | Pages 106 - 108
1 Jan 1998
Ngarmukos C Parkpian V Patradul A

We treated 110 fractures of the middle third of the clavicle in 108 patients aged between 14 and 66 years, by fixation with 2 mm Kirschner wires. The wire was introduced, using an air drill and a telescoping guide, from the medial into the lateral fragment. The medial end of the wire which perforated the anterior cortex of the medial fragment was bent backwards to prevent migration into the lung or mediastinum. In cases of nonunion and acute fracture in which a bone gap was present, bone graft was laid around the fracture site after internal fixation. All the fractures united. No wires broke but in three patients one migrated before union was achieved. Twenty-one patients failed to return for removal of the wire; nine of them had radiological evidence of union before they were lost to follow-up


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 5 | Pages 761 - 766
1 Sep 1996
Aoki M Okamura K Fukushima S Takahashi T Ogino T

We treated 12 shoulders in ten patients with irreparable rotator-cuff tears by transfer of the latissimus dorsi. There were nine men and one woman. Their average age was 64.0 years and the average follow-up was 35.6 months (26 to 42). The results were excellent in four shoulders, good in four, fair in one, and poor in three. Active forward flexion improved from a preoperative average of 99° to a postoperative average of 135°. Osteoarthritic changes appeared in five shoulders and proximal migration of the humeral head progressed in six. EMG revealed that nine of the 12 transferred muscles showed activity which was synergistic with the supraspinatus on external rotation with abduction. We conclude that latissimus dorsi transfer can be effective in restoring shoulder function after massive irreparable tears of the rotator cuff


Bone & Joint 360
Vol. 8, Issue 4 | Pages 42 - 44
1 Aug 2019


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 1022 - 1026
1 Aug 2006
Langlais F Belot N Ropars M Lambotte JC Thomazeau H

We evaluated the long-term fixation of 64 press-fit cemented stems of constrained total knee prostheses in 32 young patients with primary malignant bone tumours. Initial stable fixation, especially in rotation, was achieved by precise fit of the stem into the reamed endosteum, before cementation. Complementary fixation, especially in migration and rotation, was obtained by pressurised antibiotic-loaded cement. The mean age at operation was 33 years (13 to 61). No patient was lost to follow-up; 13 patients died and the 19 survivors were examined at a mean follow-up of 12.5 years (4 to 21). Standard revision press-fit cemented stems were used on the side of the joint which was not involved with tumour (26 tibial and six femoral), on this side there was no loosening or osteolysis and stem survival was 100%. On the reconstruction side, custom-made press-fit stems were used and the survival rate, with any cause for revision as an end point, was 88%, but 97% for loosening or osteolysis. This longevity is similar to that achieved at 20 years with the Charnley-Kerboull primary total hip replacement with press-fit cemented femoral components. We recommend this type of fixation when extensive reconstruction of the knee is required. It may also be suitable for older patients requiring revision of a total knee replacement or in difficult situations such as severe deformity and complex articular fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 3 | Pages 441 - 446
1 May 1989
Cooke P Cole W Carey R

To determine the natural history of dislocation of the hip in cerebral palsy, and to evolve methods to predict dislocation, the notes and radiographs of 462 patients with cerebral palsy were reviewed. Dislocation occurred in 10% of patients by progressive migration and subluxation of the proximal femur in the presence of acetabular dysplasia. Statistical analysis identified the radiographic features that helped to predict dislocation. Measurement of acetabular index, by a method that allows for rotation of the acetabulum, was the most powerful single predictor. Measurement of this index at two and four years of age could identify patients who would dislocate unless effective treatment was undertaken, those at risk of dislocation only if scoliosis developed, and those who would not dislocate. On the basis of this method of screening for dislocation, a logical system of surgical prophylaxis is proposed


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 3 | Pages 433 - 436
1 May 1987
Fergusson C Morrison J Kenwright J

We have reviewed the results of amputation through the ankle in the management of 37 children with congenital leg-length discrepancy, followed up for a mean of 7.6 years after operation. In general good function was achieved and 18 patients considered their activities to be unrestricted. The main factor affecting the functional result was the underlying condition for which operation had been performed. Although heel pad migration, scar rotation and os calcis remnants were seen, these could be accommodated by the prosthesis. Syme's amputation is tolerated well in the younger child and, in patients with a predicted leg-length discrepancy of over 15 cm associated with an abnormal foot, we recommend the operation as a primary procedure between the ages of 18 months and two years


The Journal of Bone & Joint Surgery British Volume
Vol. 62-B, Issue 3 | Pages 332 - 336
1 Aug 1980
Heywood A

A high percentage of hips in patients with rheumatoid arthritis presenting for total joint replacement have protrusio deformity with extremely thin medial acetabular walls. Biomechanical principles suggest that, to prevent inward migration of the acetabular component, the prosthesis should be positioned laterally near the acetabular rim. To reinforce the medial wall, the femoral head is fashioned into a solid graft which is anchored against the medial wall as a plug, minimising the amount of cement used and making the use of wire mesh and restraining rings about the acetabulum unnecessary. A series of nine operations on seven patients is presented. Serial radiographs, tomograms and scintigrams taken after operation suggest satisfactory incorporation of the grafts, and no complications have been encountered in a follow-up period ranging from three months to two years


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 3 | Pages 416 - 419
1 Apr 2000
Kido T Itoi E Konno N Sano A Urayama M Sato K

We investigated the function of biceps in 18 patients (19 shoulders) with lesions of the rotator cuff. Their mean age was 59 years. Another series of 18 patients (19 shoulders) with normal rotator cuffs as seen on MRI acted as a control group. Their mean age was 55 years. A brace was used to maintain contraction of biceps during elevation. Anteroposterior radiographs were obtained with the arm elevated at 0°, 45° and 90° with and without contraction of biceps. The distance between the centre of the head of the humerus and the glenoid was compared in the two groups. We found that in the group with tears there was significantly greater proximal migration of the head of the humerus at 0° and 45° of elevation without contraction of biceps but depression of the head of the humerus at 0°, 45° and 90° when biceps was functioning. We conclude that biceps is an active depressor of the head of the humerus in shoulders with lesions of the rotator cuff


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 4 | Pages 602 - 606
1 Jul 1994
Lizaur A Marco L Cebrian R

We report a prospective study of 46 patients with acute complete dislocation of the acromioclavicular joint. They were all treated by suture of the deltoid and trapezius over the clavicle with no repair of the coracoclavicular ligaments, using only temporary fixation with two wires. At operation 43 patients (93.5%) had damage to the trapezius or deltoid or both. The coracoclavicular ligaments were intact in six (13%). Follow-up was from 2 to 7.9 years (mean 5.8), and at the latest review only five patients (10.9%) had redisplacement, due to premature removal of wires for infection in one, to migration of the wires in another and to partial failure of the muscle repair in three. We consider that the deltoid and trapezius attachments are important clinical stabilizers of the clavicle and that their repair, with reinforcement, is a useful addition to any method of surgical treatment


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 2 | Pages 240 - 244
1 Mar 1994
Alsema R Deutman R Mulder T

In 1988 we reported a ten-year review of 83 surviving patients from a group of 135 (146 prostheses) who had undergone primary hip replacement using the Stanmore prosthesis. We have now reviewed 44 of these patients at 15 to 16 years. Four patients had undergone revision, but the other 40 were all satisfied with the result of their hip replacement, 36 having little or no pain. Functional activities had decreased, but were still adequate for their average age of 81 years. There had been definite migration of the cup and/or femoral component in three hips, wear of the cup in ten and resorption of the calcar in six. Of the 24 hips inserted with radiopaque cement, eight showed an increase in radiolucent lines at the acetabular interface. The cumulative survival rate of the prosthesis was 91% at 15 to 16 years


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 5 | Pages 721 - 724
1 Sep 1992
Franzen H Mjoberg B Onnerfalt R

Roentgen stereophotogrammetric analysis was used to measure the migration of 24 cemented femoral components implanted during revision for mechanical loosening. All hips were examined one week, four months and one year after surgery; 14 hips were also examined after two years. Twenty-one components subsided 0.2 to 5.5 mm during the observation period; in 17 of these, subsidence occurred within four months of surgery. In 16 hips the prosthetic head was displaced 0.7 to 11.2 mm posteriorly. The fixation of the femoral components was less secure than after primary arthroplasty, especially in cases of femoral canal enlargement, when a standard-sized rather than a thick-stemmed prosthesis had been used, and in cases of inadequate cement filling


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 1 | Pages 45 - 51
1 Jan 2003
Skinner JA Todo S Taylor M Wang JS Pinskerova V Scott G

We have compared the survival and radiological outcome at ten years after total hip replacement using two techniques for preparing the femoral canal. The same prosthesis was used throughout and all operations were performed by the same surgical team. In technique 1 the canal was over-reamed by 2 mm and in technique 2 it was reamed to the same size as the prosthesis. Technique 1 was performed on 92 patients and technique 2 on 97 patients. The survival at ten years was 97.2% (90.6 to 99.2) for technique 1 and 98.8% (92.9 to 99.8) for technique 2. Vertical migration was greater in technique 1 (1.8 mm versus 1.0 mm at five years; p = 0.36). There were significantly more lytic lesions and radiolucent lines at five years (p = 0.0061) with technique 1. We conclude that technique 2 is not worse and may produce better long- term results than current teaching suggests


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 1 | Pages 38 - 42
1 Jan 1991
Santavirta S Konttinen Y Hoikka V Eskola A

The membranes surrounding seven loose cementless acetabular implants were shown to contain polyethylene particles, birefringent in polarised light. Three of these implants were made of titanium alloy and the membranes around these contained titanium particles as well. There was no metallosis around the four implants made of chromium-cobalt-steel alloy. Both titanium and polyethylene particles caused migration, adherence and phagocytosis of CD11b-positive, peroxidase-negative macrophages. There were no histological signs of activation of the specific immune response; neither interleukin-2 receptor-positive activated T cells nor PCA-1 plasmablasts/plasma cells were present in the tissues. In cases of simple loosening, resident mesenchymal fibroblast-like cells were active. In aggressive granulomatosis, there were many macrophages and multinucleated giant cells but little fibroblast reaction. The clinical relevance of the findings is that the use of cementless prostheses is not a guarantee against adverse tissue reactions


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 6 | Pages 1014 - 1022
1 Nov 1990
Nieder E Elson R Engelbrecht E Kasselt M Keller A Steinbrink K

We report the 12 to 74 month results of our mark I saddle prosthesis after its use as a salvage device for gross loss of pelvic bone stock in 76 patients with failed hip arthroplasties. The implant transmits load between iliac bone and bare polish chrome-cobalt. Our clinical and radiological results indicate that a useful and stable articulation can be achieved in most cases, provided that continued deep infection can be avoided. The appearance of radiological sclerosis at the bearing site in successful cases seems to indicate that significant late migration will not occur. Based on our experience with the mark I prosthesis we have designed and developed a mark II model which has freedom of axial rotation of the saddle. Our early results in 40 cases show a significant improvement over the results which could have been predicted for the mark I device


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 2 | Pages 259 - 265
1 Mar 2004
Saldanha KAN Saleh M Bell MJ Fernandes JA

We performed limb lengthening and correction of deformity of nine long bones of the lower limb in six children (mean age, 14.7 years) with osteogenesis imperfecta (OI). All had femoral lengthening and three also had ipsilateral tibial lengthening. Angular deformities were corrected simultaneously. Five limb segments were treated using a monolateral external fixator and four with the Ilizarov frame. In three children, lengthening was done over previously inserted femoral intramedullary rods. The mean lengthening achieved was 6.26 cm (mean healing index, 33.25 days/cm). Significant complications included one deep infection, one fracture of the femur and one anterior angulation deformity of the tibia. The abnormal bone of OI tolerated the external fixators throughout the period of lengthening without any episodes of migration of wires or pins through the soft bone. The regenerate bone formed within the time which is normally expected in limb-lengthening procedures performed for other conditions. We conclude that despite the abnormal bone characteristics, distraction osteogenesis to correct limb-length discrepancy and angular deformity can be performed safely in children with OI


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 1 | Pages 87 - 92
1 Jan 1997
Oonishi H Iwaki Y Kin N Kushitani S Murata N Wakitani S Imoto K

Hydroxyapatite (HA) granules of 100 to 300 μm, 0.9 to 1.2 mm and 3.0 to 5.0 mm were mixed in a ratio of 10:45:45 and packed into massive bone deficiencies in revision operations for total hip arthroplasty. We did not use additional graft or cup support for deficiencies of the lateral and medial wall. The procedure was carried out in 40 hips between 1986 and 1992. The radiographic spaces seen at the interface between HA and bone immediately after surgery disappeared within three months. Some spaces appeared between HA granules near the bone in the lateral part of two joints, and three sockets migrated in patients with severe segmental and cavitary deficiencies. Direct bonding of HA to bone was observed radiologically without morphological changes, except in the three joints with migration. All patients could walk without pain but the three with definite loosening needed crutches


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1442 - 1448
1 Nov 2018
Hipfl C Janz V Löchel J Perka C Wassilew GI

Aims

Severe acetabular bone loss and pelvic discontinuity (PD) present particular challenges in revision total hip arthroplasty. To deal with such complex situations, cup-cage reconstruction has emerged as an option for treating this situation. We aimed to examine our success in using this technique for these anatomical problems.

Patients and Methods

We undertook a retrospective, single-centre series of 35 hips in 34 patients (seven male, 27 female) treated with a cup-cage construct using a trabecular metal shell in conjunction with a titanium cage, for severe acetabular bone loss between 2011 and 2015. The mean age at the time of surgery was 70 years (42 to 85) and all patients had an acetabular defect graded as Paprosky Type 2C through to 3B, with 24 hips (69%) having PD. The mean follow-up was 47 months (25 to 84).


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 7 | Pages 979 - 987
1 Sep 2001
Hamadouche M Witvoet J Porcher R Meunier A Sedel L Nizard R

We have carried out a prospective, randomised study designed to compare the long-term stability of the stem of cementless femoral implants with differing surface configurations. A total of 50 hips (46 patients) was randomised into two groups, according to whether the medullary stem had been grit blasted (GB) or coated with hydroxyapatite (HA). Both femoral prostheses were of the same geometrical design. We used Ein Bild Roentgen Analyse femoral component analysis (EBRA-FCA) to assess the stability of the stem. The mean follow-up was for 8.66 years. The mean migration of the stem was 1.26 mm in the HA group compared with 2.57 mm in the GB group (Mann-Whitney U test, p = 0.04). A mixed model ANOVA showed that the development of subsidence was statistically different in the two groups during the first 24 months. After this subsidence increased in both groups with no difference between them. Our results indicate that, with the same design of stem, HA coating enhanced the stability of the femoral stem when compared with GB stems


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 5 | Pages 692 - 699
1 Jul 2002
Takwale VJ Nuttall D Trail IA Stanley JK

We have implanted 76 biaxial total wrist prostheses as a primary procedure in patients with rheumatoid arthritis of the wrist. A total of 66 was reviewed at a mean follow-up time of 52 months. Pain was relieved in 67% of the surviving wrist replacements. On the basis of the Hospital for Special Surgery scoring system, 49 wrists (74%) were graded as fair to excellent. More than half of the 27 patients who had an arthrodesis on the contralateral wrist would have preferred a second arthroplasty. Five replacements were revised or fused because of loosening and a further nine showed signs of radiological loosening, three of which were asymptomatic. The probability of survival of the biaxial total wrist replacement at eight years was 83% with revision surgery as the terminal event, 78% with radiological loosening as the endpoint and 82% with dorsal migration and displacement from the metacarpal as the terminal event. There was a linear relationship between subsidence of the component and distal loosening. There was no evidence that the length of the stem of the carpal component, within the third metacarpal, affected any of the terminal events. The position and alignment of the carpal component within the bone at the time of surgery significantly affect the outcome and can be used to predict failure


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 3 | Pages 352 - 357
1 Apr 2000
Milošev L Antolič V Minovič A Cör A Herman S Pavlovčič V Campbell P

We describe three prostheses with cemented titanium-alloy stems and Al. 2. O. 3. ceramic femoral heads which had to be revised after a mean period of implantation of 78 months. In each case, the neck of the prosthesis had been so severely worn that the profile was elliptical rather than circular. There was severe metallosis of the periprosthetic tissues. Metal particles isolated from the tissues were approximately one nanometre in size and the ratios of titanium, aluminium and vanadium in the particles were the same as in the original alloy. Histologically, the high concentration of metal particles masked the presence of high-density polyethylene (HDP) debris, but again particles about one nanometre in size were isolated from the tissues. The severe necrobiosis and necrosis noted were consistent with other reports of the presence of extensive wear particles in periprosthetic tissues. Wear is presumed to have occurred as a result of mismatch between the shape or size of the taper cone and the femoral head, or to changes in the geometry of loading due to migration of the cup. To facilitate early intervention, patients with this design of prosthesis should be monitored radiologically