Advertisement for orthosearch.org.uk
Results 481 - 500 of 1734
Results per page:
Bone & Joint 360
Vol. 10, Issue 1 | Pages 19 - 24
1 Feb 2021


Bone & Joint 360
Vol. 10, Issue 3 | Pages 29 - 31
1 Jun 2021


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1732 - 1732
1 Dec 2015
Haddad FS

M-C. Lee, C-W. Ha, R. K. Elmallah, J. J. Cherian, J. J. Cho, T. W. Kim, S. I. Bin, and M. A. Mont.A placebo-controlled randomised trial to assess the effect of TGF-ß1-expressing chondrocytes in patients with arthritis of the knee.Bone Joint J 2015;97-B:924–932


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 928 - 931
1 Jul 2012
Keenan ACM Wood AM Arthur CA Jenkins PJ Brenkel IJ Walmsley PJ

We report the ten-year survival of a cemented total knee replacement (TKR) in patients aged < 55 years at the time of surgery, and compare the functional outcome with that of patients aged > 55 years. The data were collected prospectively and analysed using Kaplan-Meier survival statistics, with revision for any reason, or death, as the endpoint. A total of 203 patients aged < 55 years were identified. Four had moved out of the area and were excluded, leaving a total of 221 TKRs in 199 patients for analysis (101 men and 98 women, mean age 50.6 years (28 to 55)); 171 patients had osteoarthritis and 28 had inflammatory arthritis. Four patients required revision and four died. The ten-year survival using revision as the endpoint was 98.2% (95% confidence interval 94.6 to 99.4). Based on the Oxford knee scores at five and ten years, the rate of dissatisfaction was 18% and 21%, respectively. This was no worse in the patients aged < 55 years than in patients aged > 55 years. These results demonstrate that the cemented PFC Sigma knee has an excellent survival rate in patients aged < 55 ten years post-operatively, with clinical outcomes similar to those of an older group. We conclude that TKR should not be withheld from patients on the basis of age


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1222 - 1230
1 Jul 2021
Slullitel PA Garcia-Barreiro GG Oñativia JI Zanotti G Comba F Piccaluga F Buttaro MA

Aims

We aimed to compare the implant survival, complications, readmissions, and mortality of Vancouver B2 periprosthetic femoral fractures (PFFs) treated with internal fixation with that of B1 PFFs treated with internal fixation and B2 fractures treated with revision arthroplasty.

Methods

We retrospectively reviewed the data of 112 PFFs, of which 47 (42%) B1 and 27 (24%) B2 PFFs were treated with internal fixation, whereas 38 (34%) B2 fractures underwent revision arthroplasty. Decision to perform internal fixation for B2 PFFs was based on specific radiological (polished femoral components, intact bone-cement interface) and clinical criteria (low-demand patient). Median follow-up was 36.4 months (24 to 60). Implant survival and mortality over time were estimated with the Kaplan-Meier method. Adverse events (measured with a modified Dindo-Clavien classification) and 90-day readmissions were additionally compared between groups.


Bone & Joint 360
Vol. 9, Issue 6 | Pages 27 - 30
1 Dec 2020


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 66 - 70
1 Jan 2010
Reidsma II Nolte PA Marti RK Raaymakers ELFB

In this retrospective study, using the prospectively collected database of the AO-Documentation Centre, we analysed the outcome of 57 malunited fractures of the ankle treated by reconstructive osteotomy. In all cases the position of the malunited fibula had been corrected, in several cases it was combined with other osteotomies and the fixation of any non-united fragments. Patients were seen on a regular basis, with a minimum follow-up of ten years. The aim of the study was to establish whether reconstruction improves ankle function and prevents the progression of arthritic changes. Good or excellent results were obtained in 85% (41) of patients indicating that reconstructive surgery is effective in most and that the beneficial effects can last for up to 27 years after the procedure. Minor post-traumatic arthritis is not a contraindication but rather an indication for reconstructive surgery. We also found that prolonged time to reconstruction is associated negatively with outcome


The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 100 - 106
1 Jan 2017
Aujla RS Sheikh N Divall P Bhowal B Dias JJ

Aims. We performed a systematic review of the current literature regarding the outcomes of unconstrained metacarpophalangeal joint (MCPJ) arthroplasty. Materials and Methods. We initially identified 1305 studies, and 406 were found to be duplicates. After exclusion criteria were applied, seven studies were included. Outcomes extracted included pre- and post-operative pain visual analogue scores, range of movement (ROM), strength of pinch and grip, satisfaction and patient reported outcome measures (PROMs). Clinical and radiological complications were recorded. The results are presented in three groups based on the design of the arthroplasty and the aetiology (pyrocarbon-osteoarthritis (pyro-OA), pyrocarbon-inflammatory arthritis (pyro-IA), metal-on-polyethylene (MoP)). Results. Results show that pyrocarbon implants provide an 85% reduction in pain, 144% increase of pinch grip and 13° improvements in ROM for both OA and IA combined. Patients receiving MoP arthroplasties had a reduction in pinch strength. Satisfaction rates were 91% and 92% for pyrocarbon-OA and pyrocarbon-IA groups, respectively. There were nine failures in 87 joints (10.3%) over a mean follow-up of 5.5 years (1.0 to 14.3) for pyro-OA. There were 18 failures in 149 joints (12.1%) over a mean period of 6.6 years (1.0 to 16.0) for pyro-IA. Meta-analysis was not possible due to the heterogeneity of the studies and the limited presentation of data. Conclusion. We would recommend prospective data collection for small joint arthroplasties of the hand consisting of PROMs that would allow clinicians to come to stronger conclusions about the impact on function of replacing the MCPJs. A national joint registry may be the best way to achieve this. Cite this article: Bone Joint J 2017;99-B:100–6


The Journal of Bone & Joint Surgery British Volume
Vol. 31-B, Issue 4 | Pages 537 - 539
1 Nov 1949
Gervis WH

1. The technique of excision of the trapezium for osteoarthritis of the trapezio-metacarpal joint is described. 2. The results of eighteen operations in fifteen patients are analysed. 3. The operation is of value particularly when the arthritis is monarticular. Results have been less satisfactory when the affection of the joint is part of a generalised arthritis


Bone & Joint Open
Vol. 2, Issue 3 | Pages 150 - 163
1 Mar 2021
Flett L Adamson J Barron E Brealey S Corbacho B Costa ML Gedney G Giotakis N Hewitt C Hugill-Jones J Hukins D Keding A McDaid C Mitchell A Northgraves M O'Carroll G Parker A Scantlebury A Stobbart L Torgerson D Turner E Welch C Sharma H

Aims

A pilon fracture is a severe ankle joint injury caused by high-energy trauma, typically affecting men of working age. Although relatively uncommon (5% to 7% of all tibial fractures), this injury causes among the worst functional and health outcomes of any skeletal injury, with a high risk of serious complications and long-term disability, and with devastating consequences on patients’ quality of life and financial prospects. Robust evidence to guide treatment is currently lacking. This study aims to evaluate the clinical and cost-effectiveness of two surgical interventions that are most commonly used to treat pilon fractures.

Methods

A randomized controlled trial (RCT) of 334 adult patients diagnosed with a closed type C pilon fracture will be conducted. Internal locking plate fixation will be compared with external frame fixation. The primary outcome and endpoint will be the Disability Rating Index (a patient self-reported assessment of physical disability) at 12 months. This will also be measured at baseline, three, six, and 24 months after randomization. Secondary outcomes include the Olerud and Molander Ankle Score (OMAS), the five-level EuroQol five-dimenison score (EQ-5D-5L), complications (including bone healing), resource use, work impact, and patient treatment preference. The acceptability of the treatments and study design to patients and health care professionals will be explored through qualitative methods.


Bone & Joint 360
Vol. 9, Issue 6 | Pages 22 - 27
1 Dec 2020


Aims

We report the long-term outcomes of the UK Heel Fracture Trial (HeFT), a pragmatic, multicentre, two-arm, assessor-blinded, randomized controlled trial.

Methods

HeFT recruited 151 patients aged over 16 years with closed displaced, intra-articular fractures of the calcaneus. Patients with significant deformity causing fibular impingement, peripheral vascular disease, or other significant limb injuries were excluded. Participants were randomly allocated to open reduction and internal fixation (ORIF) or nonoperative treatment. We report Kerr-Atkins scores, self-reported difficulty walking and fitting shoes, and additional surgical procedures at 36, 48, and 60 months.


The Bone & Joint Journal
Vol. 103-B, Issue 6 | Pages 1088 - 1095
1 Jun 2021
Banger M Doonan J Rowe P Jones B MacLean A Blyth MJB

Aims

Unicompartmental knee arthroplasty (UKA) is a bone-preserving treatment option for osteoarthritis localized to a single compartment in the knee. The success of the procedure is sensitive to patient selection and alignment errors. Robotic arm-assisted UKA provides technological assistance to intraoperative bony resection accuracy, which is thought to improve ligament balancing. This paper presents the five-year outcomes of a comparison between manual and robotically assisted UKAs.

Methods

The trial design was a prospective, randomized, parallel, single-centre study comparing surgical alignment in patients undergoing UKA for the treatment of medial compartment osteoarthritis (ISRCTN77119437). Participants underwent surgery using either robotic arm-assisted surgery or conventional manual instrumentation. The primary outcome measure (surgical accuracy) has previously been reported, and, along with secondary outcomes, were collected at one-, two-, and five-year timepoints. Analysis of five-year results and longitudinal analysis for all timepoints was performed to compare the two groups.


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 67 - 73
1 Jun 2021
Lee G Wakelin E Randall A Plaskos C

Aims

Neither a surgeon’s intraoperative impression nor the parameters of computer navigation have been shown to be predictive of the outcomes following total knee arthroplasty (TKA). The aim of this study was to determine whether a surgeon, with robotic assistance, can predict the outcome as assessed using the Knee Injury and Osteoarthritis Outcome Score (KOOS) for pain (KPS), one year postoperatively, and establish what factors correlate with poor KOOS scores in a well-aligned and balanced TKA.

Methods

A total of 134 consecutive patients who underwent TKA using a dynamic ligament tensioning robotic system with a tibia first resection technique and a cruciate sacrificing ultracongruent TKA system were enrolled into a prospective study. Each TKA was graded based on the final mediolateral ligament balance at 10° and 90° of flexion: 1) < 1 mm difference in the thickness of the tibial insert and that which was planned (n = 75); 2) < 1 mm difference (n = 26); 3) between 1 mm to 2 mm difference (n = 26); and 4) > 2 mm difference (n = 7). The mean one-year KPS score for each grade of TKA was compared and the likelihood of achieving an KPS score of > 90 was calculated. Finally, the factors associated with lower KPS despite achieving a high-grade TKA (grade A and B) were analyzed.


Bone & Joint Research
Vol. 10, Issue 6 | Pages 354 - 362
1 Jun 2021
Luo Y Zhao X Yang Z Yeersheng R Kang P

Aims

The purpose of this study was to examine the efficacy and safety of carbazochrome sodium sulfonate (CSS) combined with tranexamic acid (TXA) on blood loss and inflammatory responses after primary total hip arthroplasty (THA), and to investigate the influence of different administration methods of CSS on perioperative blood loss during THA.

Methods

This study is a randomized controlled trial involving 200 patients undergoing primary unilateral THA. A total of 200 patients treated with intravenous TXA were randomly assigned to group A (combined intravenous and topical CSS), group B (topical CSS), group C (intravenous CSS), or group D (placebo).


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 45 - 50
1 Jun 2021
Kerbel YE Johnson MA Barchick SR Cohen JS Stevenson KL Israelite CL Nelson CL

Aims

It has been shown that the preoperative modification of risk factors associated with obesity may reduce complications after total knee arthroplasty (TKA). However, the optimal method of doing so remains unclear. The aim of this study was to investigate whether a preoperative Risk Stratification Tool (RST) devised in our institution could reduce unexpected intensive care unit (ICU) transfers and 90-day emergency department (ED) visits, readmissions, and reoperations after TKA in obese patients.

Methods

We retrospectively reviewed 1,614 consecutive patients undergoing primary unilateral TKA. Their mean age was 65.1 years (17.9 to 87.7) and the mean BMI was 34.2 kg/m2 (SD 7.7). All patients underwent perioperative optimization and monitoring using the RST, which is a validated calculation tool that provides a recommendation for postoperative ICU care or increased nursing support. Patients were divided into three groups: non-obese (BMI < 30 kg/m2, n = 512); obese (BMI 30 kg/m2 to 39.9 kg/m2, n = 748); and morbidly obese (BMI > 40 kg/m2, n = 354). Logistic regression analysis was used to evaluate the outcomes among the groups adjusted for age, sex, smoking, and diabetes.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 41 - 45
1 Nov 2013
Zywiel MG Mont MA Callaghan JJ Clohisy JC Kosashvili Y Backstein D Gross AE

Down’s syndrome is associated with a number of musculoskeletal abnormalities, some of which predispose patients to early symptomatic arthritis of the hip. The purpose of the present study was to review the general and hip-specific factors potentially compromising total hip replacement (THR) in patients with Down’s syndrome, as well as to summarise both the surgical techniques that may anticipate the potential adverse impact of these factors and the clinical results reported to date. A search of the literature was performed, and the findings further informed by the authors’ clinical experience, as well as that of the hip replacement in Down Syndrome study group. The general factors identified include a high incidence of ligamentous laxity, as well as associated muscle hypotonia and gait abnormalities. Hip-specific factors include: a high incidence of hip dysplasia, as well as a number of other acetabular, femoral and combined femoroacetabular anatomical variations. Four studies encompassing 42 hips, which reported the clinical outcomes of THR in patients with Down’s syndrome, were identified. All patients were successfully treated with standard acetabular and femoral components. The use of supplementary acetabular screw fixation to enhance component stability was frequently reported. The use of constrained liners to treat intra-operative instability occurred in eight hips. Survival rates of between 81% and 100% at a mean follow-up of 105 months (6 to 292) are encouraging. Overall, while THR in patients with Down’s syndrome does present some unique challenges, the overall clinical results are good, providing these patients with reliable pain relief and good function. Cite this article: Bone Joint J 2013;95-B, Supple A:41–5


Bone & Joint Open
Vol. 2, Issue 6 | Pages 397 - 404
1 Jun 2021
Begum FA Kayani B Magan AA Chang JS Haddad FS

Limb alignment in total knee arthroplasty (TKA) influences periarticular soft-tissue tension, biomechanics through knee flexion, and implant survival. Despite this, there is no uniform consensus on the optimal alignment technique for TKA. Neutral mechanical alignment facilitates knee flexion and symmetrical component wear but forces the limb into an unnatural position that alters native knee kinematics through the arc of knee flexion. Kinematic alignment aims to restore native limb alignment, but the safe ranges with this technique remain uncertain and the effects of this alignment technique on component survivorship remain unknown. Anatomical alignment aims to restore predisease limb alignment and knee geometry, but existing studies using this technique are based on cadaveric specimens or clinical trials with limited follow-up times. Functional alignment aims to restore the native plane and obliquity of the joint by manipulating implant positioning while limiting soft tissue releases, but the results of high-quality studies with long-term outcomes are still awaited. The drawbacks of existing studies on alignment include the use of surgical techniques with limited accuracy and reproducibility of achieving the planned alignment, poor correlation of intraoperative data to long-term functional outcomes and implant survivorship, and a paucity of studies on the safe ranges of limb alignment. Further studies on alignment in TKA should use surgical adjuncts (e.g. robotic technology) to help execute the planned alignment with improved accuracy, include intraoperative assessments of knee biomechanics and periarticular soft-tissue tension, and correlate alignment to long-term functional outcomes and survivorship.


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 59 - 66
1 Jun 2021
Abhari S Hsing TM Malkani MM Smith AF Smith LS Mont MA Malkani AL

Aims

Alternative alignment concepts, including kinematic and restricted kinematic, have been introduced to help improve clinical outcomes following total knee arthroplasty (TKA). The purpose of this study was to evaluate the clinical results, along with patient satisfaction, following TKA using the concept of restricted kinematic alignment.

Methods

A total of 121 consecutive TKAs performed between 11 February 2018 to 11 June 2019 with preoperative varus deformity were reviewed at minimum one-year follow-up. Three knees were excluded due to severe preoperative varus deformity greater than 15°, and a further three due to requiring revision surgery, leaving 109 patients and 115 knees to undergo primary TKA using the concept of restricted kinematic alignment with advanced technology. Patients were stratified into three groups based on the preoperative limb varus deformity: Group A with 1° to 5° varus (43 knees); Group B between 6° and 10° varus (56 knees); and Group C with varus greater than 10° (16 knees). This study group was compared with a matched cohort of 115 TKAs and 115 patients using a neutral mechanical alignment target with manual instruments performed from 24 October 2016 to 14 January 2019.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 4 | Pages 663 - 666
1 Jul 1999
Sawant MR Bendall SP Kavanagh TG Citron ND

In two years we treated four women with ununited stress fractures of their proximal tibial diaphyses. They all had arthritis and valgus deformity. The stress fractures had been treated elsewhere by non-operative means in three patients and by open reduction and internal fixation in one, but had failed to unite. After treatment with a modular total knee prosthesis with a long tibial stem extension, all the fractures united. A modular total knee prosthesis is suitable for the rare and difficult problem of ununited tibial stress fractures in patients with deformed arthritic knees since it corrects the deformity and the adverse biomechanics at the fracture site, stabilises the fracture and treats the arthritis