Advertisement for orthosearch.org.uk
Results 461 - 480 of 4189
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 2 | Pages 145 - 148
1 Feb 2008
Stockley I Mockford BJ Hoad-Reddick A Norman P

We present a series of 114 patients with microbiologically-proven chronically-infected total hip replacement, treated between 1991 and 2004 by a two-stage exchange procedure with antibiotic-loaded cement, but without the use of a prolonged course of antibiotic therapy. The mean follow-up for all patients was 74 months (2 to 175) with all surviving patients having a minimum follow-up of two years. Infection was successfully eradicated in 100 patients (87.7%), a rate which is similar to that reported by others, but where prolonged adjuvant antibiotic therapy has been used. Using the technique described, a prolonged course of systemic antibiotics does not appear to be essential and the high cost of the administration of antibiotics can be avoided.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 4 | Pages 521 - 522
1 Jul 1997
Sandhu SS Lowry JC Morton ME Reuben SF


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 4 | Pages 550 - 555
1 Aug 1988
Linder L Carlsson A Marsal L Bjursten L Branemark P

In an experimental clinical study, 25 implants of pure titanium were inserted into the proximal tibia of 11 volunteer patients, four with rheumatoid arthritis and seven with osteoarthritis. The implants were removed from five weeks to 24 months later and detailed histological analysis was performed. The implants generally healed with direct bone-metal contact, showing so-called osseointegration. Only one of the 21 implants which had been in place for over five months did not show osseointegration, probably because of inadequate primary contact with bone. The presence of rheumatoid disease did not prevent osseointegration, but accompanying osteoporosis seemed to be a risk factor.


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 3 | Pages 367 - 372
1 May 1988
Samuelson K Freeman M Levack B Rassmussen G Revell P

Thirty-seven patients with extensive acetabular defects due to loose implants had revisions with uncemented components, the acetabulum being augmented with homograft bone. In six of these, a histological study of graft incorporation was made. At a mean follow-up of 1.5 years 34 patients were free of pain and 35 could walk for 30 minutes or longer. No graft had obviously sequestrated. Two components had radiological evidence of migration but remain asymptomatic. We conclude that cementless revision surgery with homograft supplementation of the acetabulum is clinically successful in the short-term. The long-term outcome is unknown.


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 3 | Pages 308 - 309
1 May 1983
Rushton N Dandy D Naylor C

Thirty-nine patients underwent reconstruction of the anterior cruciate ligament with carbon-fibre and a MacIntosh repair; all had a negative pivot shift test after operation. Some patients had persistent pain, mild effusion and synovial thickening; in 10 of these patients the symptoms warranted arthroscopic examination and biopsy at a mean of 16.9 months after the repair. Arthroscopy revealed that the carbon-fibre had not induced the formation of a "new ligament" and that the repair was merely covered by a thin, fibrous sheath. Histological investigations confirmed this finding, with only a suggestion of a fibroblastic response to carbon-fibre found in two patients. Particles of carbon-fibre were found scattered through the knees. Synovitis and breakdown of the skin over subcutaneous carbon-fibre complicated treatment. Failure of the carbon-fibre to bond to bone was detected radiographically.


The Journal of Bone & Joint Surgery British Volume
Vol. 54-B, Issue 1 | Pages 61 - 76
1 Feb 1972
Charnley J

1. The results have been reported of total hip replacement by a low-friction technique using high-density polyethylene for the acetabular component in 379 primary interventions, performed between November 1962 and December 1965 and followed for between four and seven years.

2. Apart from failures due to infection, the rate of which in the era under review was 3·8 per cent, late failures from mechanical causes were unusual after total hip replacement by this technique. When the socket was cemented in position, which is now routine, the late mechanical failure from all causes was only 1·3 per cent in 210 cases.

3. As regards the quality of the results and their maintenance over the years, the results were so good (Table X) that it was unnecessary to distinguish an intermediate class of "improvement" between success and failure.

4. As regards relief of pain and ability to walk, the average final rating, on a scale numbered 1 to 6, was 5·9 for both, indicating 90 per cent of patients in Grade 6 (excellent) and only 10 per cent in Grade 5 (good).

5. The average recovery of movement was not as spectacular and was influenced considerably by the pre-operative range, but in all cases that range was improved on. Even starting with the stiffest of hips about one patient in four regained a right angle of flexion movement. There was no tendency to lose movement with the passage of time.

6. As regards late infection (2·2 per cent out of a total of 3·8 per cent), the various findings tend to exonerate cement as a cause.

7. The mechanical details of the technique became stabilised in the period 1959 to 1962 in the Teflon era, and with the exception of improved methods of reattachment of the greater trochanter, they are identical with our current practice in 1971.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 937 - 940
1 Jul 2012
Manopoulos P Havet E Pearce O Lardanchet JF Mertl P

This was a retrospective analysis of the medium- to long-term results of 46 TC3 Sigma revision total knee replacements using long uncemented stems in press-fit mode.

Clinical and radiological analysis took place pre-operatively, at two years post-operatively, and at a mean follow-up of 8.5 years (4 to 12). The mean pre-operative International Knee Society (IKS) clinical score was 42 points (0 to 74), improving to 83.7 (52 to 100) by the final follow-up. The mean IKS score for function improved from 34.3 points (0 to 80) to 64.2 (15 to 100) at the final follow-up. At the final follow-up 30 knees (65.2%) had an excellent result, seven (15.2%) a good result, one (2.2%) a medium and eight (17.4%) a poor result. There were two failures, one with anteroposterior instability and one with aseptic loosening.

The TC3 revision knee system, when used with press-fit for long intramedullary stems and cemented femoral and tibial components, in both septic and aseptic revisions, results in a satisfactory clinical and radiological outcome, and has a good medium- to long-term survival rate.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 4 | Pages 535 - 541
1 Apr 2008
Pendegrass CJ Sundar S Oddy MJ Cannon SR Briggs T Blunn GW

We used an in vivo model to assess the use of an autogenous cancellous bone block and marrow graft for augmenting tendon reattachment to metallic implants. We hypothesised that augmentation of the tendon-implant interface with a bone block would enable retention of the graft on the implant surface, enhance biological integration, and result in more consistent functional outcomes compared with previously reported morcellised graft augmentation techniques.

A significant improvement in functional weight-bearing was observed between six and 12 weeks. The significant increase in ground reaction force through the operated limb between six and 12 weeks was greater than that reported previously with morcellised graft augmented reconstructions. Histological appearance and collagen fibre orientation with bone block augmentation more closely resembled that of an intact enthesis compared with the morcellised grafting technique. Bone block augmentation of tendon-implant interfaces results in more reliable functional and histological outcomes, with a return to pre-operative levels of weight-bearing by 24 weeks.


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 5 | Pages 746 - 751
1 Nov 1987
Saito M Saito S Ohzono K Ono K

We have followed up a series of total hip arthroplasties performed for secondary osteoarthritis and analysed the results in relation to the osteoblastic response to the disease. This was assessed pre-operatively from the radiographic appearance, according to Bombelli's criteria (1983). Of 63 hips in 55 patients followed up for five to 13 years, 17 were hypertrophic, 24 normotrophic and 22 atrophic in type. The atrophic-type hips showed a high incidence of acetabular loosening, leading to unsatisfactory clinical results in 32%. By contrast, the hypertrophic-type hips had a low incidence of acetabular loosening, while the normotrophic type showed intermediate results. It was concluded that the osteoblastic response to osteoarthritis is closely related to acetabular loosening and to late clinical failure.


Bone & Joint Open
Vol. 5, Issue 3 | Pages 218 - 226
15 Mar 2024
Voigt JD Potter BK Souza J Forsberg J Melton D Hsu JR Wilke B

Aims. Prior cost-effectiveness analyses on osseointegrated prosthesis for transfemoral unilateral amputees have analyzed outcomes in non-USA countries using generic quality of life instruments, which may not be appropriate when evaluating disease-specific quality of life. These prior analyses have also focused only on patients who had failed a socket-based prosthesis. The aim of the current study is to use a disease-specific quality of life instrument, which can more accurately reflect a patient’s quality of life with this condition in order to evaluate cost-effectiveness, examining both treatment-naïve and socket refractory patients. Methods. Lifetime Markov models were developed evaluating active healthy middle-aged male amputees. Costs of the prostheses, associated complications, use/non-use, and annual costs of arthroplasty parts and service for both a socket and osseointegrated (OPRA) prosthesis were included. Effectiveness was evaluated using the questionnaire for persons with a transfemoral amputation (Q-TFA) until death. All costs and Q-TFA were discounted at 3% annually. Sensitivity analyses on those cost variables which affected a change in treatment (OPRA to socket, or socket to OPRA) were evaluated to determine threshold values. Incremental cost-effectiveness ratios (ICERs) were calculated. Results. For treatment-naïve patients, the lifetime ICER for OPRA was $279/quality-adjusted life-year (QALY). For treatment-refractory patients the ICER was $273/QALY. In sensitivity analysis, the variable thresholds that would affect a change in the course of treatment based on cost (from socket to OPRA), included the following for the treatment-naïve group: yearly replacement components for socket > $8,511; cost yearly replacement parts OPRA < $1,758; and for treatment-refractory group: yearly replacement component for socket of > $12,467. Conclusion. The use of the OPRA prosthesis in physically active transfemoral amputees should be considered as a cost-effective alternative in both treatment-naïve and treatment-refractory socket prosthesis patients. Disease-specific quality of life assessments such as Q-TFA are more sensitive when evaluating cost-effectiveness. Cite this article: Bone Jt Open 2024;5(3):218–226


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 3 | Pages 464 - 465
1 Apr 2003
DE ROECK N


Bone & Joint Open
Vol. 4, Issue 7 | Pages 490 - 495
4 Jul 2023
Robinson PG Creighton AP Cheng J Dines JS Su EP Gulotta LV Padgett D Demetracopoulos C Hawkes R Prather H Press JM Clement ND

Aims. The primary aim of this prospective, multicentre study is to describe the rates of returning to golf following hip, knee, ankle, and shoulder arthroplasty in an active golfing population. Secondary aims will include determining the timing of return to golf, changes in ability, handicap, and mobility, and assessing joint-specific and health-related outcomes following surgery. Methods. This is a multicentre, prospective, longitudinal study between the Hospital for Special Surgery, (New York City, New York, USA) and Edinburgh Orthopaedics, Royal Infirmary of Edinburgh, (Edinburgh, UK). Both centres are high-volume arthroplasty centres, specializing in upper and lower limb arthroplasty. Patients undergoing hip, knee, ankle, or shoulder arthroplasty at either centre, and who report being golfers prior to arthroplasty, will be included. Patient-reported outcome measures will be obtained at six weeks, three months, six months, and 12 months. A two-year period of recruitment will be undertaken of arthroplasty patients at both sites. Conclusion. The results of this prospective study will provide clinicians with accurate data to deliver to patients with regard to the likelihood of return to golf and timing of when they can expect to return to golf following their hip, knee, ankle, or shoulder arthroplasty, as well as their joint-specific functional outcomes. This will help patients to manage their postoperative expectations and plan their postoperative recovery pathway. Cite this article: Bone Jt Open 2023;4(7):490–495


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 5 | Pages 702 - 705
1 Jul 2001
Tanaka N Sakahashi H Sato E Hirose K Ishima T Ishii S

We studied 99 patients who were undergoing total knee arthroplasty (TKA) to determine the optimum protocol for the administration of tranexamic acid (TNA) in order to reduce blood loss. It decreased by more than 40% after the administration of TNA. The haemostatic effect was greatest when TNA was given preoperatively and on deflation of the tourniquet. There was no increase in the incidence of adverse affects in the patients receiving TNA, compared with a control group.

We conclude that two injections of TNA, one given preoperatively and one on deflation of the tourniquet, significantly reduce blood loss without increasing the risk of thromboembolic complications.


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 5 | Pages 677 - 680
1 Sep 1993
Onsten I Bengner U Besjakov J

Socket migration and rotation in the Charnley total hip replacement were evaluated by roentgen stereophotogrammetric analysis in 23 patients with rheumatoid arthritis and 23 patients with osteoarthritis. The two groups were matched with regard to age and sex. The follow-up time was two years. In the rheumatoid patients socket migration was most prominent in the proximal direction and averaged 0.6 mm at 24 months as compared with 0.1 mm in the osteoarthritic group (p = 0.0003). Within the rheumatoid group a preoperative acetabular protrusion in five patients was associated with increased migration and rotation in all directions. The increased proximal migration in rheumatoid arthritis was consistent (p = 0.0009) even after the exclusion of the five protrusion cases. In the rheumatoid patients there was a correlation between low body-weight and proximal migration, but there was no such correlation in the osteoarthritic group. Our results suggest that socket fixation is less secure in patients with advanced inflammatory arthritis.


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 2 | Pages 217 - 223
1 Mar 1988
Mackinnon J Young S Baily R

Since 1974, we have made a prospective study in Bristol of the results of unicompartmental knee replacement using the St Georg sledge prosthesis. A total of 115 knees in 100 patients have been followed up for 2 to 12 years (mean, 4 years 9 months). Results have assessed both by the Bristol knee score and by survivorship studies on the total series of 138 knees. Results were excellent or good in 86% and fair or poor in 14%. The survivorship study (based on a definition of failure which included significant pain or a dissatisfied patient or the need for revision) showed a cumulative success rate of 76.4% at six years, with no further failures after that time. Seven knees have been revised, in most cases for deterioration of the contralateral compartment. The operation is recommended as a satisfactory and durable form of treatment for osteoarthritis affecting a single tibiofemoral compartment.


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 5 | Pages 829 - 834
1 Nov 1985
Amis A Campbell Miller J

The calcaneal tendons of rabbits were excised and either replaced with a carbon or polyester fibre implant, or left as controls. The strength of the neotendons and their mode of failure under tension were examined at intervals up to six months after operation. Return to near normal strength took six months to develop, suggesting that patients having ligament or tendon reconstructions should not resume normal activity for several months. Carbon fibre-based neotendons showed progressive elongation which, unless avoided by a sufficient period of immobilisation, would affect the functional result.


Bone & Joint Open
Vol. 5, Issue 8 | Pages 637 - 643
6 Aug 2024
Abelleyra Lastoria DA Casey L Beni R Papanastasiou AV Kamyab AA Devetzis K Scott CEH Hing CB

Aims. Our primary aim was to establish the proportion of female orthopaedic consultants who perform arthroplasty via cases submitted to the National Joint Registry (NJR), which covers England, Wales, Northern Ireland, the Isle of Man, and Guernsey. Secondary aims included comparing time since specialist registration, private practice participation, and number of hospitals worked in between male and female surgeons. Methods. Publicly available data from the NJR was extracted on the types of arthroplasty performed by each surgeon, and the number of procedures of each type undertaken. Each surgeon was cross-referenced with the General Medical Council (GMC) website, using GMC number to extract surgeon demographic data. These included sex, region of practice, and dates of full and specialist registration. Results. Of 2,895 surgeons contributing to the NJR in 2023, 102 (4%) were female. The highest proportions of female surgeons were among those who performed elbow (n = 25; 5%), shoulder (n = 24; 4%), and ankle (n = 8; 4%) arthroplasty. Hip (n = 66; 3%) and knee arthroplasty (n = 39; 2%) had the lowest female representation. Female surgeons had been practising for a median of 10.4 years since specialist registration compared to 13.7 years for males (p < 0.001). Northern Ireland was the region with the highest proportion of female arthroplasty surgeons (8%). A greater proportion of male surgeons worked in private practice (63% vs 24%; p < 0.001) and in multiple hospitals (74% vs 40%; p < 0.001). Conclusion. Only 4% of surgeons currently contributing cases to the NJR are female, with the highest proportion performing elbow arthroplasty (5%). Female orthopaedic surgeons in the NJR are earlier in their careers than male surgeons, and are less involved in private practice. There is a wide geographical variation in the proportion of female arthroplasty surgeons. Cite this article: Bone Jt Open 2024;5(8):637–643


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1286 - 1293
1 Dec 2023
Yang H Cheon J Jung D Seon J

Aims. Fungal periprosthetic joint infections (PJIs) are rare, but their diagnosis and treatment are highly challenging. The purpose of this study was to investigate the clinical outcomes of patients with fungal PJIs treated with two-stage exchange knee arthroplasty combined with prolonged antifungal therapy. Methods. We reviewed our institutional joint arthroplasty database and identified 41 patients diagnosed with fungal PJIs and treated with two-stage exchange arthroplasty after primary total knee arthroplasty (TKA) between January 2001 and December 2020, and compared them with those who had non-fungal PJIs during the same period. After propensity score matching based on age, sex, BMI, American Society of Anesthesiologists grade, and Charlson Comorbidity Index, 40 patients in each group were successfully matched. The surgical and antimicrobial treatment, patient demographic and clinical characteristics, recurrent infections, survival rates, and relevant risk factors that affected joint survivorship were analyzed. We defined treatment success as a well-functioning arthroplasty without any signs of a PJI, and without antimicrobial suppression, at a minimum follow-up of two years from the time of reimplantation. Results. The fungal PJI group demonstrated a significantly worse treatment success rate at the final follow-up than the non-fungal PJI group (65.0% (26/40) vs 85.0% (34/40); p < 0.001). The mean prosthesis-free interval was longer in the fungal PJI group than in the non-fungal PJI group (6.7 weeks (SD 5.8) vs 4.1 weeks (SD 2.5); p = 0.020). The rate of survivorship free from reinfection was worse in the fungal PJI group (83.4% (95% confidence interval (CI) 64.1 to 92.9) at one year and 76.4% (95% CI 52.4 to 89.4) at two years) than in the non-fungal PJI group (97.4% (95% CI 82.7 to 99.6) at one year and 90.3% (95% CI 72.2 to 96.9) at two years), but the differences were not significant (p = 0.270). Cox proportional hazard regression analysis identified the duration of the prosthesis-free interval as a potential risk factor for failure (hazard ratio 1.128 (95% CI 1.003 to 1.268); p = 0.043). Conclusion. Fungal PJIs had a lower treatment success rate than non-fungal PJIs despite two-stage revision arthroplasty and appropriate antifungal treatment. Our findings highlight the need for further developments in treating fungal PJIs. Cite this article: Bone Joint J 2023;105-B(12):1286–1293


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1067 - 1073
1 Oct 2024
Lodge CJ Adlan A Nandra RS Kaur J Jeys L Stevenson JD

Aims. Periprosthetic joint infection (PJI) is a challenging complication of any arthroplasty procedure. We reviewed our use of static antibiotic-loaded cement spacers (ABLCSs) for staged management of PJI where segmental bone loss, ligamentous instability, or soft-tissue defects necessitate a static construct. We reviewed factors contributing to their failure and techniques to avoid these complications when using ABLCSs in this context. Methods. A retrospective analysis was conducted of 94 patients undergoing first-stage revision of an infected knee prosthesis between September 2007 and January 2020 at a single institution. Radiographs and clinical records were used to assess and classify the incidence and causes of static spacer failure. Of the 94 cases, there were 19 primary total knee arthroplasties (TKAs), ten revision TKAs (varus-valgus constraint), 20 hinged TKAs, one arthrodesis (nail), one failed spacer (performed elsewhere), 21 distal femoral endoprosthetic arthroplasties, and 22 proximal tibial arthroplasties. Results. A total of 35/94 patients (37.2%) had spacer-related complications, of which 26/35 complications (74.3%) were because of mechanical failure of the spacer construct, while 9/35 (25.7%) were due to recurrence of infection. Risk factors for internal failure were a construct where the total intramedullary spacer length was less than twice the length of the central osseous defect (p = 0.009), where proximal or distal intraosseous spacer contact was < 10%, and after tibial tubercle osteotomy (p = 0.005). The incidence of spacer complications significantly increased the time to second stage: mean 157 days (42 to 458) in those without complications versus 227 days (11 to 528) with complications (p = 0.014). Conclusion. The failure rate of static antibiotic-loaded cement spacers is much higher than anticipated. Complications of the spacer significantly increased the time to second-stage revision. The risk of mechanical failure is significantly increased if the spacer is less than double the size of the segmental defect, or if inadequate reinforcement is inserted into the residual bone. These findings serve as a guide for surgeons to avoid mechanical complications with static spacers. Cite this article: Bone Joint J 2024;106-B(10):1067–1073


The Journal of Bone & Joint Surgery British Volume
Vol. 41-B, Issue 2 | Pages 365 - 368
1 May 1959
Clark K

1. A case of giant-cell tumour of the proximal end of the humerus treated by resection and fibular grafting twenty-nine years ago is reported. An excellent functional result has been maintained.

2. The literature is reviewed and the results claimed by earlier workers are noted.

3. The present field of application of the operation is probably in cases of advanced or recurrent giant-cell tumour of bone.