Advertisement for orthosearch.org.uk
Results 461 - 480 of 966
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 55-B, Issue 1 | Pages 66 - 86
1 Feb 1973
Graham R Russell G Smith R

1. The phosphonates are simple chemical compounds containing P-C-P bonds which are resistant to the action of naturally occurring phosphatases and pyrophosphatases. They inhibit the formation and dissolution of apatite crystals in vitro and prevent ectopic mineralisation and bone resorption in animals. 2. In man one diphosphonate (EHDP) has been shown to reduce the excessive turnover of bone in Paget's disease and also appears to slow the mineralisation of ectopic bone matrix in myositis ossificans progressiva. 3. The possible uses of the diphosphonates in bone disorders with excessive resorption and in ectopic mineralisation are being further investigated


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 5 | Pages 748 - 752
1 Jul 2003
Nyffeler RW Anglin C Sheikh R Gerber C

Fixation of the glenoid component is critical to the outcome of total shoulder arthroplasty. In an in vitro study, we analysed the effect of surface design and thickness of the cement mantle on the pull-out strength of the polyethylene pegs which are considered essential for fixation of cemented glenoid components. The macrostructure and surface of the pegs and the thickness of the cement mantle were studied in human glenoid bone. The lowest pull-out forces, 20 ± 5 N, were for cylindrical pegs with a smooth surface fixed in the glenoid with a thin cement mantle. The highest values, 425 ± 7 N, were for threaded pegs fixed with a thicker cement mantle. Increasing the diameter of the hole into which the peg is inserted from 5.2 to 6.2 mm thereby increasing the thickness of the cement mantle, improved the mean pull-out force for the pegs tested


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 4 | Pages 561 - 565
1 May 2002
Akagi M Kaneda E Nakamura T Ueno M Yamanashi W Miyajima H

The Bisurface knee prosthesis (BP) has a posterior stabilising cam (ball-and-socket joint) in the mid-posterior region of the femorotibial joint in an attempt to improve the range of movement. Based on an in vitro weight-bearing study contact areas of the Insall/Burstein 2 (IB2) and the BP knee were compared using pressure-sensitive films. The stability afforded by the cam was evaluated by means of dislocation distances in the vertical and horizontal planes. Significant adverse anterior translation in mid-flexion was not observed with the BP knee since the cam was effective above 60° of flexion. At flexion of 60° or more, the total contact areas were larger, as the cam represented a weight-bearing surface. The dislocation distances for the BP knee compared favourably with those for the IB2 knee. We conclude that the cam of the BP knee allows good movement, stability and wear


Objectives

Osteoporosis is a systemic bone metabolic disease, which often occurs among the elderly. Angelica polysaccharide (AP) is the main component of angelica sinensis, and is widely used for treating various diseases. However, the effects of AP on osteoporosis have not been investigated. This study aimed to uncover the functions of AP in mesenchymal stem cell (MSC) proliferation and osteoblast differentiation.

Methods

MSCs were treated with different concentrations of AP, and then cell viability, Cyclin D1 protein level, and the osteogenic markers of runt-related transcription factor 2 (RUNX2), osteocalcin (OCN), alkaline phosphatase (ALP), bone morphogenetic protein 2 (BMP-2) were examined by Cell Counting Kit-8 (CCK-8) and western blot assays, respectively. The effect of AP on the main signalling pathways of phosphatidylinositol 3-kinase (PI3K)/protein kinase B (AKT) and Wnt/β-catenin was determined by western blot. Following this, si-H19#1 and si-H19#2 were transfected into MSCs, and the effects of H19 on cell proliferation and osteoblast differentiation in MSCs were studied. Finally, in vivo experimentation explored bone mineral density, bone mineral content, and the ash weight and dry weight of femoral bone.


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 3 | Pages 429 - 432
1 May 1987
Middleton R Frost R

This paper describes the design, development and early surgical experience with a stereotactic device to allow closed retrieval and interchange of intramedullary rods in children with osteogenesis imperfecta. This relatively atraumatic procedure may allow more frequent rod interchange than with other techniques, lessening the likelihood of deformity and fracture in the unsupported skeleton when the bone has outgrown the intramedullary rod. The procedure was developed by design studies in vitro followed by intramedullary rodding of tibiae of New Zealand white rabbits. It has been used in children 12 times, in six tibiae and six femora: 11 rods have been successfully retrieved, with rod interchange in eight of these cases


The Journal of Bone & Joint Surgery British Volume
Vol. 57-B, Issue 2 | Pages 234 - 237
1 May 1975
Levin PD

The effectiveness of different antibiotics mixed with Simplex P has been tested in vitro. A laboratory model was designed to simulate the constant immersion of bone cement in tissue fluid. Clindamycin, and to a lesser extent Cephalothin, were shown to be effective when used in this manner against Staphylococcus aureus and epidermidis. Effective inhibition of Gram-negative organisms could not be demonstrated with any of the antibiotics tested. The addition of up to 3 grams of antibiotic powder per unit of 40 grams of Simplex P did not appear to alter the expansive properties of the cement. Such release of antibiotic as did occur was thought to be related to the slow absorption of water by the slightly porous methyl methacrylate


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 5 | Pages 740 - 747
1 Jul 2003
Dragoo JL Samimi B Zhu M Hame SL Thomas BJ Lieberman JR Hedrick MH Benhaim P

Multipotential processed lipoaspirate (PLA) cells extracted from five human infrapatellar fat pads and embedded into fibrin glue nodules, were induced into the chondrogenic phenotype using chondrogenic media. The remaining cells were placed in osteogenic media and were transfected with an adenovirus carrying the cDNA for bone morphogenetic protein-2 (BMP-2). We evaluated the tissue-engineered cartilage and bone using in vitro techniques and by placing cells into the hind legs of five severe combined immunodeficient mice. After six weeks, radiological and histological analysis indicated that the PLA cells induced into the chondrogenic phenotype had the histological appearance of hyaline cartilage. Cells transfected with the BMP-2 gene media produced abundant bone, which was beginning to establish a marrow cavity. Tissue-engineered cartilage and bone from infrapatellar fat pads may prove to be useful for the treatment of osteochondral defects


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 2 | Pages 288 - 291
1 Mar 2003
Sampathkumar K Jeyam M Evans CE Andrew JG

Aseptic loosening of orthopaedic implants is usually attributed to the action of wear debris from the prosthesis. Recent studies, however, have also implicated physical pressures in the joint as a further cause of loosening. We have examined the role of both wear debris and pressure on the secretion of two chemokines, MIP-1α and MCP-1, together with M-CSF and PGE2, by human macrophages in vitro. The results show that pressure alone stimulated the secretion of more M-CSF and PGE. 2. when compared with control cultures. Particles alone stimulated the secretion of M-CSF and PGE. 2. , when compared with unstimulated control cultures, but did not stimulate the secretion of the two chemokines. Exposure of macrophages to both stimuli simultaneously had no synergistic effect on the secretion of the chemokines, but both M-CSF and PGE. 2. were increased in a synergistic manner. Our findings suggest that pressure may be an initiating factor for the recruitment of cells into the periprosthetic tissue


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 821 - 824
1 Jun 2008
Board TN Rooney P Kay PR

In order to investigate the osteoinductive properties of allograft used in impaction grafting and the effect of strain during impaction on these properties, we designed an in vitro experiment to measure strain-related release of bone morphogenetic protein-7 (BMP-7) from fresh-frozen femoral head allograft. A total of 40 10 mm cubes of cancellous bone were cut from ten samples of fresh-frozen femoral head. The marrow was removed from the cubes and the baseline concentrations of BMP-7 were measured. Specimens from each femoral head were allocated to four groups and subjected to different compressive strains with a material testing machine, after which BMP-7 activity was reassessed. It was present in all groups. There was a linear increase of 102.1 pg/g (95% confidence interval 68.6 to 135.6) BMP-7 for each 10% increase in strain. At 80% strain the mean concentration of BMP-7 released (830.3 pg/g bone) was approximately four times that released at 20% strain. Activity of BMP-7 in fresh-frozen allograft has not previously been demonstrated. This study shows that the freezing and storage of femoral heads allows some maintenance of biological activity, and that impaction grafting provides a source of osteoinductive bone for remodelling. We have shown that BMP-7 is released from fresh-frozen femoral head cancellous bone in proportion to the strain applied to the bone. This suggests that the impaction process itself may contribute to the biological process of remodelling and bony incorporation


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 2 | Pages 254 - 258
1 Mar 1993
Kabo J Gebhard J Loren G Amstutz H

Polyethylene acetabular cups retrieved at revision surgery were measured by a shadowgraph technique to determine linear wear, and the values were compared with those obtained from radiographs. There was a close correlation between them, although the radiographic measurements slightly underestimated the true wear. Average linear wear rates for surface-replacement components were much greater than those for conventional prostheses with femoral heads up to 32 mm in diameter. Volumetric wear, calculated using a new formula, was found to be less than previously reported in vivo, and similar in magnitude to the results of experimental wear tests in vitro. The volumetric wear rates were greatest for the surface-replacement components and, for conventional components, were found to increase in a linear manner with component diameter


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 8 | Pages 1196 - 1201
1 Nov 2003
Mandelin J Li T Liljeström M Kroon ME Hanemaaijer R Santavirta S Konttinen YT

In the differentiation of osteoclasts the differentiation factor (RANKL) interacts with the receptor activator of NF-κB (RANK) in a direct cell-to-cell contact between osteoblast and (pre)osteoclast. This is inhibited by soluble osteoprotegerin (OPG). The mRNA levels of both RANKL (p < 0.01) and RANK (p < 0.05) were high in peri-implant tissue and RANKL+ and RANK+ cells were found in such tissue. Double labelling also disclosed soluble RANKL bound to RANK+ cells. We were unable to stimulate fibroblasts to express RANKL in vitro, but monocyte activation with LPS gave a fivefold increase in RANK mRNA levels. In contrast to RANKL and RANK expression in peri-implant tissue, expression of OPG was restricted to vascular endothelium. Endothelial cell OPG mRNA levels were regulated by TNF-α and VEGF, but not by hypoxia. It is concluded that activated cells in the interface tissue overproduce both RANKL and RANK and they can interact without interference by OPG


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 1 | Pages 57 - 62
1 Jan 1992
Athanasou N Quinn J Bulstrode C

The role of inflammatory cells in aseptic loosening and failure of cemented joint replacements is unclear. Inflammatory cells from the revision joint capsule of four failed hip arthroplasties were examined to determine their nature and resorptive capacity. The capsules contained numerous macrophages and abundant foreign-body macrophage polykaryons, distinguished from osteoclasts by their antigenic phenotype and lack of response to calcitonin. When cultured on cortical bone slices in vitro, both macrophages and macrophage polykaryons produced small resorption pits and were associated with areas of superficial resorption of the bone surface. These results indicate that foreign-body induced macrophages and macrophage polykaryons are capable of a type of low-grade bone resorption which may be of pathogenic significance in the loosening of cemented joint prosthetic components


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 11 | Pages 1568 - 1574
1 Nov 2005
Day RE Megson S Wood D

Allograft bone is widely used in orthopaedic surgery, but peri-operative infection of the graft remains a common and disastrous complication. The efficacy of systemic prophylactic antibiotics is unproven, and since the graft is avascular it is likely that levels of antibiotic in the graft are low. Using an electrical potential to accelerate diffusion of antibiotics into allograft bone, high levels were achieved in specimens of both sheep and human allograft. In human bone these ranged from 187.1 mg/kg in endosteal (. sd. 15.7) to 124.6 (. sd. 46.2) in periosteal bone for gentamicin and 31.9 (. sd. 8.9) in endosteal and 2.9 (. sd. 1.1) in periosteal bone for flucloxacillin. The antibiotics remained active against bacteria in vitro after iontophoresis and continued to elute from the allograft for up to two weeks. Structural allograft can be supplemented directly with antibiotics using iontophoresis. The technique is simple and inexpensive and offers a potential means of reducing the rate of peri-operative infection in allograft surgery. Iontophoresis into allograft bone may also be applicable to other therapeutic compounds


The Journal of Bone & Joint Surgery British Volume
Vol. 60-B, Issue 3 | Pages 370 - 374
1 Aug 1978
Grobbelaar C du Plessis T Marais F

The radiation crosslinking of high-density polyethylene prostheses was investigated over a wide range of doses in the presence and absence of gaseous crosslinking agents. It was found that in the bulk polymer the crosslinking pattern is completely different from the homogeneous crosslinking that occurs in polymer films. The presence of crosslinking agents causes highly crosslinked polymer to be formed on the surface while the bulk of the polymer is largely unaffected--which is explained in terms of diffusion phenomena. This surface crosslinking has a profound effect on the mechanical properties of the prostheses and restricts cold flow and deformation of the polymer without sacrificing the excellent abrasion-resistance properties of the polyethylene when subjected to high pressures. Based on this research a number of high-density polyethylene knee prostheses have been radiation-crosslinked and the results in vitro appear to be very promising


The Journal of Bone & Joint Surgery British Volume
Vol. 43-B, Issue 1 | Pages 95 - 99
1 Feb 1961
Markowa J

1. A child is described in whom an acute osteitis was produced by some organism which could neither be identified nor cultured in vitro, and which provoked a violent general reaction but which also showed a distinct affinity for the central nervous system. 2. This organism survived in a cavity in the femur for four months; it preserved its pathogenic properties, and could only be cultured in living tissue. 3. A twice repeated passage through animals increased the toxicity of this organism and proved its affinity for the central nervous system. 4. This organism may have been a virus similar to those producing encephalitis. A final answer may be obtained by further attempts to provoke experimental osteitis with live cultures of viruses in animals


The Journal of Bone & Joint Surgery British Volume
Vol. 39-B, Issue 4 | Pages 758 - 762
1 Nov 1957
Lavine LS Burger M Sobel AE

1. The influence of various methods of preserving bone on the calcifying mechanism of the tibial epiphysial cartilage of rachitic rats was studied. An in vitro calcification technique was employed. 2. Preservation by deep freezing, aqueous merthiolate, boiling, or acetone inactivated the calcifying mechanism. 3. The inactivation was reversed with calcium ions, most readily in the deep-frozen bones, less readily in the merthiolate treated bones, still less readily in the acetone stored bones, and least in boiled bones. 4. Exposure to calcium ions before preservation in the deep-freeze chest prevented inactivation. 5. The inactivation, reactivation and survival of the calcifying mechanism were confirmed by metachromasia studies. 6. The theory of the mode of action of calcium chloride on reactivation and survival of the calcifying mechanism is presented


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 5 | Pages 888 - 893
1 Sep 1998
Overgaard L Danielsen N Bjursten LM

Little is known about the tissue reactions to various implant materials which coincide with an inflammatory reaction. We used the avridine arthritis rat model to evaluate the tissue response in the synovial, interstitial and subcutaneous tissues after implant insertion. Quantitative immunohistochemistry showed that normal joint synovial tissue is dominated by ED2-positive resident macrophages. Polyethylene implants induced a much stronger foreign-body reaction than titanium implants, as measured by the number of interfacial ED1-positive macrophages. The tissue response to titanium and polyethylene was also vastly different in arthritic synovial tissue compared with control tissue. It is likely that these biomaterials interact differently with inflammatory cells or intermediary compounds. It may be that arthritic synovial tissue produces reactive oxygen intermediates (free radicals) with which titanium has a unique anti-inflammatory interaction in vitro


Bone & Joint Research
Vol. 7, Issue 10 | Pages 548 - 560
1 Oct 2018
Qayoom I Raina DB Širka A Tarasevičius Š Tägil M Kumar A Lidgren L

During the last decades, several research groups have used bisphosphonates for local application to counteract secondary bone resorption after bone grafting, to improve implant fixation or to control bone resorption caused by bone morphogenetic proteins (BMPs). We focused on zoledronate (a bisphosphonate) due to its greater antiresorptive potential over other bisphosphonates. Recently, it has become obvious that the carrier is of importance to modulate the concentration and elution profile of the zoledronic acid locally. Incorporating one fifth of the recommended systemic dose of zoledronate with different apatite matrices and types of bone defects has been shown to enhance bone regeneration significantly in vivo. We expect the local delivery of zoledronate to overcome the limitations and side effects associated with systemic usage; however, we need to know more about the bioavailability and the biological effects. The local use of BMP-2 and zoledronate as a combination has a proven additional effect on bone regeneration. This review focuses primarily on the local use of zoledronate alone, or in combination with bone anabolic factors, in various preclinical models mimicking different orthopaedic conditions.

Cite this article: I. Qayoom, D. B. Raina, A. Širka, Š. Tarasevičius, M. Tägil, A. Kumar, L. Lidgren. Anabolic and antiresorptive actions of locally delivered bisphosphonates for bone repair: A review. Bone Joint Res 2018;7:548–560. DOI: 10.1302/2046-3758.710.BJR-2018-0015.R2.


Bone & Joint Research
Vol. 7, Issue 11 | Pages 587 - 594
1 Nov 2018
Zhang R Li G Zeng C Lin C Huang L Huang G Zhao C Feng S Fang H

Objectives

The role of mechanical stress and transforming growth factor beta 1 (TGF-β1) is important in the initiation and progression of osteoarthritis (OA). However, the underlying molecular mechanisms are not clearly known.

Methods

In this study, TGF-β1 from osteoclasts and knee joints were analyzed using a co-cultured cell model and an OA rat model, respectively. Five patients with a femoral neck fracture (four female and one male, mean 73.4 years (68 to 79)) were recruited between January 2015 and December 2015. Results showed that TGF-β1 was significantly upregulated in osteoclasts by cyclic loading in a time- and dose-dependent mode. The osteoclasts were subjected to cyclic loading before being co-cultured with chondrocytes for 24 hours.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 1 | Pages 154 - 160
1 Jan 1997
Edwards AG McNally DS Mulholland RC Goodship AE

Posterior fixation of intervertebral discs is used to treat, and occasionally diagnose, discogenic pain since it is thought that it will reduce the internal loading of the discs in vitro. We measured the internal loading of ten intervertebral discs using stress profilometry under simulated physiological loads and then after posterior fixation. Partial discectomies were performed to simulate advanced disc degeneration and the sequence repeated. Posterior fixation had very little effect on the magnitude of the loads acting on the disc and none when disc degeneration was simulated. It did, however, reduce bulging of the anterior annulus under combined bending and compression (p < 0.03). Recent experiments in vivo have shown that discogenic pain is associated with abnormal bulging of the annulus which suggests that the clinical benefit of fixation may be due to this