Aseptic loosening is a major cause of failure in cemented endoprosthetic reconstructions. This paper presents the long-term outcomes of a custom-designed cross-pin fixation construct designed to minimize rotational stress and subsequent aseptic loosening in selected patients. The paper will also examine the long-term survivorship and modes of failure when using this technique. A review of 658 consecutive, prospectively collected cemented endoprosthetic reconstructions for oncological diagnoses at a single centre between 1980 and 2017 was performed. A total of 51 patients were identified with 56 endoprosthetic implants with cross-pin fixation, 21 of which were implanted following primary resection of tumour. Locations included distal femoral (n = 36), proximal femoral (n = 7), intercalary (n = 6), proximal humeral (n = 3), proximal tibial (n = 3), and distal humeral (n = 1).Aims
Patients and Methods
A number of methods have been described to remove a well-fixed humeral implant as part of revision shoulder arthroplasty. These include the use of cortical windows and humeral osteotomies. The router bit extraction technique uses a high-speed router bit to disrupt the bone-implant interface. The implant is then struck in a retrograde fashion with a square-tip impactor and mallet. The purpose of this study was to determine the characteristics and frequency of the different techniques needed for the removal of a well-fixed humeral stem in revision shoulder arthroplasty. Between 2010 and 2018, 288 revision shoulder arthroplasty procedures requiring removal of a well-fixed humeral component were carried out at a tertiary referral centre by a single surgeon. The patient demographics, indications for surgery, and method of extraction were collected.Aims
Patients and Methods
Mobile-bearing posterior-stabilised knee replacements have been developed as an alternative to the standard fixed- and mobile-bearing designs. However, little is known about the in vivo kinematics of this new group of implants. We investigated 31 patients who had undergone a total knee replacement with a similar
We have reviewed 65 bipolar arthroplasties of the hip in 55 patients with osteoarthritis secondary to dysplasia. The mean age at operation was 56 years (42 to 79) and the mean period of follow-up was 7.2 years (5.0 to 13.0). The average Merle d’Aubigné and Postel score before operation was 10.3 and at final follow-up 15.0. There were excellent or good results in 42 hips (65%). Migration of the outer head was observed in 50 hips (77%), most often in the group with a centre-edge angle of less than 0°, an acetabular head index of less than 60%, coverage of the outer head by the original acetabulum of less than +10° and after bone grafting of the acetabulum. This migration was progressive in 31 (62%) of the 50 hips, with massive osteolysis of the acetabulum in eight. The extent and progression of migration were closely associated with this osteolysis. Four hips required revision for extensive migration of the outer head with destruction of the acetabulum or severe acetabular osteolysis, and nine hips are awaiting revision for failure of the bipolar
Between 1978 and 1986, 59 patients received a GSB III elbow prosthesis, six of them in both elbows. Rheumatoid arthritis (RA) was the underlying cause in 51 of the patients and post-traumatic osteoarthritis (PTOA) in eight. Of these, 24 patients (28 prostheses) have since died; two, both operated on bilaterally, had had their implants for more than ten years and had already been assessed for inclusion in the long-term follow-up. Two patients, each with one elbow prosthesis, have been lost to follow-up and three males who are still living (two with PTOA, one with juvenile RA) had their prosthesis removed before ten years had elapsed. The remaining 32 patients (28 RA, 4 PTOA) with 36 GSB III elbows were examined clinically and radiologically after a mean period of 13.5 years. Pain was considerably reduced in 91.6%. Mobility was increased by 37° in those with RA and by 67° in those with PTOA. There were three cases of aseptic loosening and three of deep infection. The main complication was disassembly of the
We have tested the axial and torsional stability of femoral components after revision arthroplasty in a cadaver model, using impacted morsellised cancellous graft and cement. Each one of six matched pairs of fresh frozen human femora had either a primary or a revision prosthesis cemented in place. For the ‘revision’ experiments, all cancellous bone was removed from the proximal femur which was then over-reamed to create a smooth-walled cortical shell. An MTS servohydraulic test frame was used to apply axial and torsional loads to each specimen through the
Bone growth into cementless
From 1986 to 1991 we fitted 20 children with endoprostheses after resection of malignant bone tumours of the leg; six have reached skeletal maturity and are the subject of this study. Reconstruction of defects in growing limbs in which the eventual shortening can be predicted requires the use of extendable prostheses. The mean age at operation was 11 years (9.2 to 13.7) and the average follow-up period was 6.3 years (4.3 to 7.6). The diagnosis was osteosarcoma in five patients and Ewing's sarcoma in one. All tumours were Enneking stage-IIB. When seen for follow-up all patients were free from disease. The extendable implants used included the Pafford-Lewis prosthesis and the Kotz Modular Femur Tibia Reconstruction system with a compatible, newly-designed growth module. Telescope-like elongation of the prostheses was performed by insertion of a screwdriver through a small skin incision. Active epiphyseal growth in the adjacent growth plate was preserved by using
The vertical migration of four configurations of a proximal femoral prosthesis, followed for up to nine years, was measured on standard radiographs. The same implant was used without cement (group 1) and with cement (group 2). The migration of both groups was linear from six months onwards. The mean migration rate and the incidence of late aseptic loosening were both greater in group 1. Survival analysis of the two groups, however, showed no statistically significant difference. In both groups, hips later destined for revision migrated more rapidly from the initial postoperative period onwards, than did the remainder. A threshold migration of 1.2 mm/year during the first two years after implantation detected hips likely to fail with a specificity of 86% and a sensitivity of 78%. This 'migration test' was applied to the results in two further groups of patients in which a modified femoral prosthesis had been implanted without hydroxyapatite coating (group 3) and with hydroxyapatite coating (group 4). The test distinguished between the four groups and suggested that at least two fixation procedures should be abandoned. We conclude that vertical migration measured on standard radiographs in the first two years after implantation can be used to predict late aseptic loosening. New
The aim of this study was to conduct the largest low contact stress (LCS) retrieval study to elucidate the failure mechanisms of the Porocoat and Duofix femoral component. The latter design was voluntarily recalled by the manufacturer. Uncemented LCS explants were divided into three groups: Duofix, Porocoat, and mixed. Demographics, polyethylene wear, tissue ingrowth, and metallurgical analyses were performed.Aims
Materials and Methods
Radiostereometric analysis (RSA) studies of vitamin E-doped, highly crosslinked polyethylene (VEPE) liners show low head penetration rates in cementless acetabular components. There is, however, currently no data on cemented VEPE acetabular components in total hip arthroplasty (THA). The aim of this study was to evaluate the safety of a new cemented VEPE component, compared with a conventional polyethylene (PE) component regarding migration, head penetration, and clinical results. We enrolled 42 patients (21 male, 21 female) with osteoarthritis and a mean age of 67 years (Aims
Patients and Methods
Options for the treatment of intra-articular ligament injuries are limited, and insufficient ligament reconstruction can cause painful joint instability, loss of function, and progressive development of degenerative arthritis. This study aimed to assess the capability of a biologically enhanced matrix material for ligament reconstruction to withstand tensile forces within the joint and enhance ligament regeneration needed to regain joint function. A total of 18 New Zealand rabbits underwent bilateral anterior cruciate ligament reconstruction by autograft, FiberTape, or FiberTape-augmented autograft. Primary outcomes were biomechanical assessment (n = 17), microCT (µCT) assessment (n = 12), histological evaluation (n = 12), and quantitative polymerase chain reaction (qPCR) analysis (n = 6).Aims
Materials and Methods
The aim of this study was to assess the effects of transferring patients to a specialized arthroplasty centre between the first and second stages (interstage) of prosthetic joint infection (PJI) of the knee. A search of our institutional database was performed to identify patients having undergone two-stage revision total knee arthroplasty (TKA) for PJI. Two cohorts were created: continuous care (CC) and transferred care (TC). Baseline characteristics and outcomes were collected and compared between cohorts.Aims
Patients and Methods
To our knowledge, no study has compared the long-term results of cemented and hybrid total hip arthroplasty (THA) in patients with osteoarthritis (OA) secondary to congenital hip disease (CHD). This is a demanding procedure that may require special techniques and implants. Our aim was to compare the long-term outcome of cemented low-friction arthroplasty (LFA) and hybrid THA performed by one surgeon. Between January 1989 and December 1997, 58 hips (44 patients; one man, 43 woman; mean age 56.6 years (25 to 77)) with OA secondary to CHD were treated with a cemented Charnley LFA (group A), and 55 hips (39 patients; two men, 37 women; mean age 49.1 years (27 to 70)) were treated with a hybrid THA (group B), by the senior author (GH). The clinical outcome and survivorship were compared.Aims
Patients and Methods
Modular dual mobility (DM) prostheses in which a cobalt-chromium liner is inserted into a titanium acetabular shell ( This was a prospective study of patients between 18 and 65 years of age, with a body mass index (BMI) < 35 kg/m2 and University of California at Los Angeles (UCLA) activity score > 6, who received a modular cobalt-chromium acetabular liner, highly crosslinked polyethylene mobile bearing, and cementless titanium femoral stem for their primary THA. Patients with a history of renal disease and metal hardware elsewhere in the body were excluded. A total of 43 patients (30 male, 13 female; mean age 52.6 years (Aims
Patients and Methods
Prosthetic joint infection (PJI) and aseptic loosening in total hip arthroplasty (THA) can present with pain and osteolysis. The Musculoskeletal Infection Society (MSIS) has provided criteria for the diagnosis of PJI. The aim of our study was to analyze the utility of F18-fluorodeoxyglucose (FDG) positron emission tomography (PET) CT scan in the preoperative diagnosis of septic loosening in THA, based on the current MSIS definition of prosthetic joint infection. A total of 130 painful unilateral cemented THAs with a mean follow-up of 5.17 years (Aims
Patients and Methods
The purpose of this study was to examine whether leg-length discrepancy (LLD) following unilateral total hip arthroplasty (THA) affects the incidence of contralateral head collapse and subsequent THA in patients with bilateral osteonecrosis, and to determine factors associated with subsequent collapse. We identified 121 patients with bilateral non-traumatic osteonecrosis who underwent THA between 2003 and 2011 to treat a symptomatic hip, and who also exhibited medium-to-large lesions (necrotic area ≥ 30%) in an otherwise asymptomatic non-operated hip. Of the 121 patients, 71 were male (59%) and 50 were female (41%), with a mean age of 51 years (19 to 71) at the time of initial THA. All patients were followed for at least five years and were assessed according to the presence of a LLD (non-LLD Aims
Patients and Methods
We used dual-energy x-ray absorptiometry (DEXA) to evaluate the extent of periprosthetic bone remodelling around a prosthesis for distal femoral reconstruction, the Kotz modular femoral tibial replacement (KMFTR; Howmedica, Rutherford, New Jersey). A total of 23 patients was entered into the study which had four parts: 1) 17 patients were scanned three times on both the implant and contralateral legs to determine whether the precision of DEXA measurements was adequate to estimate bone loss surrounding the anchorage piece of the KMFTR; 2) in 23 patients the bone mineral density (BMD) in different regions of interest surrounding the diaphyseal anchorage was compared with that of the contralateral femur at the same location to test whether there was consistent evidence of loss of BMD adjacent to the
Aseptic loosening is a major cause of failure of total hip arthroplasty. The adverse tissue response to
Patient-specific instrumentation of total knee arthroplasty (TKA) is a technique permitting the targeting of individual kinematic alignment, but deviation from a neutral mechanical axis may have implications on implant fixation and therefore survivorship. The primary objective of this randomized controlled study was to compare the fixation of tibial components implanted with patient-specific instrumentation targeting kinematic alignment (KA+PSI) A total of 47 patients due to undergo TKA were randomized to KA+PSI (n = 24) or MA+CAS (n = 23). In the KA+PSI group, there were 16 female and eight male patients with a mean age of 64 years (Aims
Patients and Methods