Clinical, radiological, and Scoliosis Research
Society-22 questionnaire data were reviewed pre-operatively and
two years post-operatively for patients with thoracolumbar/lumbar
adolescent idiopathic scoliosis treated by posterior spinal fusion
using a unilateral convex segmental pedicle screw technique. A total
of 72 patients were included (67 female, 5 male; mean age at surgery
16.7 years (13 to 23)) and divided into groups: group 1 included
53 patients who underwent fusion between the vertebrae at the limit
of the curve (proximal and distal end vertebrae); group 2 included
19 patients who underwent extension of the fusion distally beyond
the caudal end vertebra. A mean scoliosis correction of 80% (45% to 100%) was achieved.
The mean post-operative lowest instrumented vertebra angle, apical
vertebra translation and trunk shift were less than in previous
studies. A total of five pre-operative radiological parameters differed
significantly between the groups and correlated with the extension
of the fusion distally: the size of the thoracolumbar/lumbar curve,
the lowest instrumented vertebra angle, apical vertebra translation,
the Cobb angle on lumbar convex bending and the size of the compensatory
thoracic curve. Regression analysis allowed an equation incorporating
these parameters to be developed which had a positive predictive
value of 81% in determining whether the lowest instrumented vertebra
should be at the caudal end vertebra or one or two levels more distal.
There were no differences in the Scoliosis Research Society-22 outcome
scores between the two groups (p = 0.17). In conclusion, thoracolumbar/lumbar curves in patients with adolescent
idiopathic scoliosis may be effectively treated by posterior spinal
fusion using a unilateral segmental pedicle screw technique. Five
radiological parameters correlate with the need for distal extension
of the fusion, and an equation incorporating these parameters reliably
informs selection of the lowest instrumented vertebra. Cite this article:
The cause of dissatisfaction following total
knee arthroplasty (TKA) remains elusive. Much attention has been
focused on static mechanical alignment as a basis for surgical success and
optimising outcomes. More recently, research on both normal and
osteoarthritic knees, as well as kinematically aligned TKAs, has
suggested that other specific and dynamic factors may be more important
than a generic target of 0 ± 3º of a neutral axis. Consideration
of these other variables is necessary to understand ideal targets
and move beyond generic results. Cite this article:
In arthritis of the varus knee, a high tibial
osteotomy (HTO) redistributes load from the diseased medial compartment
to the unaffected lateral compartment. We report the outcome of 36 patients (33 men and three women)
with 42 varus, arthritic knees who underwent HTO and dynamic correction
using a Garches external fixator until they felt that normal alignment
had been restored. The mean age of the patients was 54.11 years
(34 to 68). Normal alignment was achieved at a mean 5.5 weeks (3
to 10) post-operatively. Radiographs, gait analysis and visual analogue
scores for pain were measured pre- and post-operatively, at one
year and at medium-term follow-up (mean six years; 2 to 10). Failure
was defined as conversion to knee arthroplasty. Pre-operative gait analysis divided the 42 knees into two equal
groups with high (17 patients) or low (19 patients) adductor moments.
After correction, a statistically significant (p <
0.001, At final follow-up, after a mean of 15.9 years (12 to 20), there
was a survivorship of 59% (95% CI 59.6 to 68.9) irrespective of
adductor moment group, with a mean time to conversion to knee arthroplasty
of 9.5 years (3 to 18; 95% confidence interval ± 2.5). HTO remains a useful option in the medium-term for the treatment
of medial compartment osteoarthritis of the knee but does not last
in the long-term. Cite this article:
The use of robots in orthopaedic surgery is an
emerging field that is gaining momentum. It has the potential for significant
improvements in surgical planning, accuracy of component implantation
and patient safety. Advocates of robot-assisted systems describe
better patient outcomes through improved pre-operative planning
and enhanced execution of surgery. However, costs, limited availability,
a lack of evidence regarding the efficiency and safety of such systems
and an absence of long-term high-impact studies have restricted
the widespread implementation of these systems. We have reviewed
the literature on the efficacy, safety and current understanding of
the use of robotics in orthopaedics. Cite this article:
The primary aim of this study was to analyse the position of
the acetabular and femoral components in total hip arthroplasty
undertaken using an anterior surgical approach. In a prospective, single centre study, we used the EOS imaging
system to analyse the position of components following THA performed
via the anterior approach in 102 patients (103 hips) with a mean
age of 64.7 years (Aims
Patients and Methods
Initial stability of tibial trays is crucial for long-term success of total knee arthroplasty (TKA) in both primary and revision settings. Rotating platform (RP) designs reduce torque transfer at the tibiofemoral interface. We asked if this reduced torque transfer in RP designs resulted in subsequently reduced micromotion at the cemented fixation interface between the prosthesis component and the adjacent bone. Composite tibias were implanted with fixed and RP primary and revision tibial trays and biomechanically tested under up to 2.5 kN of axial compression and 10° of external femoral component rotation. Relative micromotion between the implanted tibial tray and the neighbouring bone was quantified using high-precision digital image correlation techniques.Objectives
Methods
To employ a simple and fast method to evaluate those patients with neurological deficits and misplaced screws in relatively safe lumbosacral spine, and to determine if it is necessary to undertake revision surgery. A total of 316 patients were treated by fixation of lumbar and lumbosacral transpedicle screws at our institution from January 2011 to December 2012. We designed the criteria for post-operative revision scores of pedicle screw malpositioning (PRSPSM) in the lumbosacral canal. We recommend the revision of the misplaced pedicle screw in patients with PRSPSM = 5′ as early as possible. However, patients with PRSPSM < 5′ need to follow the next consecutive assessment procedures. A total of 15 patients were included according to at least three-stage follow-up.Objectives
Methods
In a multicentre, randomised study of adolescents undergoing
posterior spinal fusion for idiopathic scoliosis, we investigated
the effect of adding gelatine matrix with human thrombin to the
standard surgical methods of controlling blood loss. Patients in the intervention group (n = 30) were randomised to
receive a minimum of two and a maximum of four units of gelatine
matrix with thrombin in addition to conventional surgical methods
of achieving haemostasis. Only conventional surgical methods were
used in the control group (n = 30). We measured the intra-operative
and total blood loss (intra-operative blood loss plus post-operative
drain output).Aims
Patients and Methods
This study evaluates the long-term survival of
spinal implants after surgical site infection (SSI) and the risk
factors associated with treatment failure. A Kaplan-Meier survival analysis was carried out on 43 patients
who had undergone a posterior spinal fusion with instrumentation
between January 2006 and December 2008, and who consecutively developed
an acute deep surgical site infection. All were appropriately treated
by surgical debridement with a tailored antibiotic program based
on culture results for a minimum of eight weeks. A ‘terminal event’ or failure of treatment was defined as implant
removal or death related to the SSI. The mean follow-up was 26 months
(1.03 to 50.9). A total of ten patients (23.3%) had a terminal event.
The rate of survival after the first debridement was 90.7% (95%
confidence interval (CI) 82.95 to 98.24) at six months, 85.4% (95%
CI 74.64 to 96.18) at one year, and 73.2% (95% CI 58.70 to 87.78)
at two, three and four years. Four of nine patients required re-instrumentation
after implant removal, and two of the four had a recurrent infection
at the surgical site. There was one recurrence after implant removal
without re-instrumentation. Multivariate analysis revealed a significant risk of treatment
failure in patients who developed sepsis (hazard ratio (HR) 12.5
(95% confidence interval (CI) 2.6 to 59.9); p <
0.001) or who
had >
three fused segments (HR 4.5 (95% CI 1.25 to 24.05); p = 0.03).
Implant survival is seriously compromised even after properly treated
surgical site infection, but progressively decreases over the first
24 months. Cite this article:
This study investigated whether the use of tranexamic acid (TXA)
decreased blood loss and transfusion related cost following surface
replacement arthroplasty (SRA). A retrospective review of patients treated with TXA during a
SRA, who did not receive autologous blood (TXA group) was performed.
Two comparison groups were established; the first group comprised
of patients who donated their own blood pre-operatively (auto group)
and the second of patients who did not donate blood pre-operatively
(control). Outcomes included transfusions, post-operative haemoglobin
(Hgb), complications, and length of post-operative stay. Aims
Methods
Conventional growing rods are the most commonly
used distraction-based devices in the treatment of progressive early-onset
scoliosis. This technique requires repeated lengthenings with the
patient anaesthetised in the operating theatre. We describe the
outcomes and complications of using a non-invasive magnetically
controlled growing rod (MCGR) in children with early-onset scoliosis.
Lengthening is performed on an outpatient basis using an external remote
control with the patient awake. Between November 2009 and March 2011, 34 children with a mean
age of eight years (5 to 12) underwent treatment. The mean length
of follow-up was 15 months (12 to 18). In total, 22 children were
treated with dual rod constructs and 12 with a single rod. The mean
number of distractions per patient was 4.8 (3 to 6). The mean pre-operative
Cobb angle was 69° (46° to 108°); this was corrected to a mean 47°
(28° to 91°) post-operatively. The mean Cobb angle at final review
was 41° (27° to 86°). The mean pre-operative distance from T1 to
S1 was 304 mm (243 to 380) and increased to 335 mm (253 to 400)
in the immediate post-operative period. At final review the mean distance
from T1 to S1 had increased to 348 mm (260 to 420). Two patients developed a superficial wound infection and a further
two patients in the single rod group developed a loss of distraction.
In the dual rod group, one patient had pull-out of a hook and one
developed prominent metalwork. Two patients had a rod breakage;
one patient in the single rod group and one patient in the dual
rod group. Our early results show that the MCGR is safe and effective
in the treatment of progressive early-onset scoliosis with the avoidance
of repeated surgical lengthenings. Cite this article:
The authors present the results of a cohort study of 60 adult
patients presenting sequentially over a period of 15 years from
1997 to 2012 to our hospital for treatment of thoracic and/or lumbar
vertebral burst fractures, but without neurological deficit. All patients were treated by early mobilisation within the limits
of pain, early bracing for patient confidence and all progress in
mobilisation was recorded on video. Initial hospital stay was one
week. Subsequent reviews were made on an outpatient basis. Aims
Method
The December 2015 Knee Roundup360 looks at: Albumin and complications in knee arthroplasty; Tantalum: a knee fixation for all seasons?; Dynamic knee alignment; Tibial component design in UKA; Managing the tidal wave of revision knee arthroplasty; Scoring pain in TKR; Does anyone have a ‘normal’ tibial slope?; XLPE in TKR? A five-year clinical study; Spacers and infected revision arthroplasties; Dialysis and arthroplasty
Many aspects of total knee arthroplasty have
changed since its inception. Modern prosthetic design, better fixation techniques,
improved polyethylene wear characteristics and rehabilitation, have
all contributed to a large change in revision rates. Arthroplasty
patients now expect longevity of their prostheses and demand functional
improvement to match. This has led to a re-examination of the long-held
belief that mechanical alignment is instrumental to a successful
outcome and a focus on restoring healthy joint kinematics. A combination
of kinematic restoration and uncemented, adaptable fixation may
hold the key to future advances. Cite this article:
Oxidised zirconium was introduced as a material for femoral components
in total knee arthroplasty (TKA) as an attempt to reduce polyethylene
wear. However, the long-term survival of this component is not known. We performed a retrospective review of a prospectively collected
database to assess the ten year survival and clinical and radiological
outcomes of an oxidised zirconium total knee arthroplasty with the
Genesis II prosthesis. The Western Ontario and McMaster Universities Osteoarthritis
Index (WOMAC), Knee Injury and Osteoarthritis Outcome Score (KOOS)
and a patient satisfaction scale were used to assess outcome.Aims
Methods
Arthroscopy has become a routine surgical procedure, used as a diagnostic and therapeutic tool for the treatment of joint problems. This article discusses its origins and looks at how it is currently used.
Percutaneous placement of pedicle screws is a
well-established technique, however, no studies have compared percutaneous
and open placement of screws in the thoracic spine. The aim of this
cadaveric study was to compare the accuracy and safety of these
techniques at the thoracic spinal level. A total of 288 screws were
inserted in 16 (eight cadavers, 144 screws in percutaneous and eight
cadavers, 144 screws in open). Pedicle perforations and fractures
were documented subsequent to wide laminectomy followed by skeletalisation
of the vertebrae. The perforations were classified as grade 0: no
perforation, grade 1: <
2 mm perforation, grade 2: 2 mm to 4
mm perforation and grade 3: >
4 mm perforation. In the percutaneous
group, the perforation rate was 11.1% with 15 (10.4%) grade 1 and
one (0.7%) grade 2 perforations. In the open group, the perforation
rate was 8.3% (12 screws) and all were grade 1. This difference
was not significant (p = 0.45). There were 19 (13.2%) pedicle fractures
in the percutaneous group and 21 (14.6%) in the open group (p =
0.73). In summary, the safety of percutaneous fluoroscopy-guided
pedicle screw placement in the thoracic spine between T4 and T12
is similar to that of the conventional open technique. Cite this article:
Cardiac disease in patients with ankylosing spondylitis
(AS) has previously been studied but not in patients with a kyphosis
or in those who have undergone an operation to correct it. The aim of this study was to measure the post-operative changes
in cardiac function of patients with an AS kyphosis after pedicle
subtraction osteotomy (PSO). The original cohort consisted of 39 patients (33 men, six women).
Of these, four patients (two men, two women) were lost to follow-up
leaving 35 patients (31 men, four women) to study. The mean age
of the remaining patients was 37.4 years (22.3 to 47.8) and their
mean duration of AS was 17.0 years (4.6 to 26.4). Echocardiographic measurements,
resting heart rate (RHR), physical function score (PFS), and full-length
standing spinal radiographs were obtained before surgery and at
the two-year follow-up. The mean pre-operative RHR was 80.2 bpm (60.6 to 112.3) which
dropped to a mean of 73.7 bpm (60.7 to 90.6) at the two-year follow-up
(p = 0.0000). Of 15 patients with normal ventricular function pre-operatively,
two developed mild left ventricular diastolic dysfunction (LVDD)
at the two-year follow-up. Of 20 patients with mild LVDD pre-operatively
only five had this post-operatively. Overall, 15 patients had normal
LV diastolic function before their operation and 28 patients had
normal LV function at the two-year follow-up. The clinical improvement was 15 out of 20 (75.0%): cardiac function
in patients with AS whose kyphosis was treated by PSO was significantly
improved. Cite this article:
Mechanical alignment has been a fundamental tenet of total knee arthroplasty (TKA) since modern knee replacement surgery was developed in the 1970s. The objective of mechanical alignment was to infer the greatest biomechanical advantage to the implant to prevent early loosening and failure. Over the last 40 years a great deal of innovation in TKA technology has been focusing on how to more accurately achieve mechanical alignment. Recently the concept of mechanical alignment has been challenged, and other alignment philosophies are being explored with the intention of trying to improve patient outcomes following TKA. This article examines the evolution of the mechanical alignment concept and whether there are any viable alternatives.
A total of 22 patients with a tibial avulsion
fracture involving the insertion of the posterior cruciate ligament
(PCL) with grade II or III posterior laxity were reduced and fixed
arthroscopically using routine anterior and double posteromedial
portals. A double-strand Ethibond suture was inserted into the joint
and wrapped around the PCL from anterior to posterior to secure
the ligament above the avulsed bony fragment. Two tibial bone tunnels
were created using the PCL reconstruction guide, aiming at the medial
and lateral borders of the tibial bed. The ends of the suture were
pulled out through the bone tunnels and tied over the tibial cortex
between the openings of the tunnels to reduce and secure the bony
fragment. Satisfactory reduction of the fracture was checked arthroscopically and
radiographically. The patients were followed-up for a mean of 24.5 months (19 to
28). Bone union occurred six weeks post-operatively. At final follow-up,
all patients had a negative posterior drawer test and a full range
of movement. KT-1000 arthrometer examination showed that the mean
post-operative side-to-side difference improved from 10.9 mm (standard
deviation ( We conclude that this technique is convenient, reliable and minimally
invasive and successfully restores the stability and function of
the knee. Cite this article: