To date, there is insufficient evidence available to compare
the outcome of cemented and uncemented fixation of the humeral stem
in reverse shoulder arthroplasty (RSA). A systemic review comprising 41 clinical studies was performed
to compare the functional outcome and rate of complications of cemented
and uncemented stems in RSA. These included 1455 cemented and 329
uncemented shoulders. The clinical characteristics of the two groups
were similar. Variables were compared using pooled frequency-weighted means
and relative risk ratios (RR).Aims
Methods
Unlinked, linked and convertible total elbow
arthroplasties (TEAs) are currently available. This study is the
first to report the clinical results of the convertible Latitude
TEA. This was a retrospective study of a consecutive cohort of 63
patients (69 primary TEAs) with a mean age of 60 years (23 to 87).
Between 2006 and 2008 a total of 19 men and 50 women underwent surgery.
The mean follow-up was 43 months (8 to 84). The range of movement,
function and pain all improved six months post-operatively and either
continued to improve slightly or reached a plateau thereafter. The
complication rate is similar to that reported for other TEA systems.
No loosening was seen. Remarkable is the disengagement of the radial
head component in 13 TEAs (31%) with a radial head component implanted. Implantation of both the linked and the unlinked versions of
the Latitude TEA results in improvement of function and decreased
pain, and shows high patient satisfaction at mid-term follow-up. Cite this article:
Sporting injuries around the ankle vary from
simple sprains that will resolve spontaneously within a few days
to severe injuries which may never fully recover and may threaten
the career of a professional athlete. Some of these injuries can
be easily overlooked altogether or misdiagnosed with potentially
devastating effects on future performance. In this review article,
we cover some of the common and important sporting injuries involving
the ankle including updates on their management and outcomes. Cite this article:
The acetabular labrum is a soft-tissue structure
which lines the acetabular rim of the hip joint. Its role in hip
joint biomechanics and joint health has been of particular interest
over the past decade. In normal hip joint biomechanics, the labrum
is crucial in retaining a layer of pressurised intra-articular fluid
for joint lubrication and load support/distribution. Its seal around
the femoral head is further regarded as a contributing to hip stability through
its suction effect. The labrum itself is also important in increasing
contact area thereby reducing contact stress. Given the labrum’s
role in normal hip joint biomechanics, surgical techniques for managing
labral damage are continuously evolving as our understanding of
its anatomy and function continue to progress. The current paper
aims to review the anatomy and biomechanical function of the labrum
and how they are affected by differing surgical techniques. Take home message: The acetabular labrum plays a critical role
in hip function and maintaining and restoring its function during
surgical intervention remain an essential goal. Cite this article:
This study demonstrates a significant correlation
between the American Knee Society (AKS) Clinical Rating System and
the Oxford Knee Score (OKS) and provides a validated prediction
tool to estimate score conversion. A total of 1022 patients were prospectively clinically assessed
five years after TKR and completed AKS assessments and an OKS questionnaire.
Multivariate regression analysis demonstrated significant correlations between
OKS and the AKS knee and function scores but a stronger correlation
(r = 0.68, p <
0.001) when using the sum of the AKS knee and
function scores. Addition of body mass index and age (other statistically
significant predictors of OKS) to the algorithm did not significantly
increase the predictive value. The simple regression model was used to predict the OKS in a
group of 236 patients who were clinically assessed nine to ten years
after TKR using the AKS system. The predicted OKS was compared with
actual OKS in the second group. Intra-class correlation demonstrated
excellent reliability (r = 0.81, 95% confidence intervals 0.75 to
0.85) for the combined knee and function score when used to predict
OKS. Our findings will facilitate comparison of outcome data from
studies and registries using either the OKS or the AKS scores and
may also be of value for those undertaking meta-analyses and systematic
reviews. Cite this article:
Few reports compare the contribution of the talonavicular articulation
to overall range of movement in the sagittal plane after total ankle
arthroplasty (TAA) and tibiotalar arthrodesis. The purpose of this
study was to assess changes in ROM and functional outcomes following
tibiotalar arthrodesis and TAA. Patients who underwent isolated tibiotalar arthrodesis or TAA
with greater than two-year follow-up were enrolled in the study.
Overall arc of movement and talonavicular movement in the sagittal
plane were assessed with weight-bearing lateral maximum dorsiflexion
and plantarflexion radiographs. All patients completed Short Form-12
version 2.0 questionnaires, visual analogue scale for pain (VAS)
scores, and the Foot and Ankle Ability Measure (FAAM).Aims
Patients and Methods
The April 2015 Oncology Roundup360 looks at: New hope for skull base tumours; Survival but at what cost?; Synovial sarcoma beginning to be cracked?; Wound complications facing soft-tissue sarcoma surgeons; Amputation may offer no survival benefit over reconstruction; Giant cell tumour in the longer term; Intralesional treatment comparable with excision in GCT of the radius?; Imaging prior to oncological referral; And finally…
The purpose of this study was to analyse the biomechanics of
walking, through the ground reaction forces (GRF) measured, after
first metatarsal osteotomy or metatarsophalangeal joint (MTP) arthrodesis. A total of 19 patients underwent a Scarf osteotomy (50.3 years,
standard deviation (Aims
Patients and Methods
Our objective was to predict the knee extension strength and post-operative function in quadriceps resection for soft-tissue sarcoma of the thigh. A total of 18 patients (14 men, four women) underwent total or partial quadriceps resection for soft-tissue sarcoma of the thigh between 2002 and 2014. The number of resected quadriceps was surveyed, knee extension strength was measured with the Biodex isokinetic dynamometer system (affected side/unaffected side) and relationships between these were examined. The Musculoskeletal Tumor Society (MSTS) score, Toronto Extremity Salvage Score (TESS), European Quality of Life-5 Dimensions (EQ-5D) score and the Short Form 8 were used to evaluate post-operative function and examine correlations with extension strength. The cutoff value for extension strength to expect good post-operative function was also calculated using a receiver operating characteristic (ROC) curve and Fisher’s exact test.Objectives
Methods
High failure rates of metal-on-metal hip arthroplasty implants have highlighted the need for more careful introduction and monitoring of new implants and for the evaluation of the safety of medical devices. The National Joint Registry and other regulatory services are unable to detect failing implants at an early enough stage. We aimed to identify validated surrogate markers of long-term outcome in patients undergoing primary total hip arthroplasty (THA). We conducted a systematic review of studies evaluating surrogate markers for predicting long-term outcome in primary THA. Long-term outcome was defined as revision rate of an implant at ten years according to National Institute of Health and Care Excellence guidelines. We conducted a search of Medline and Embase (OVID) databases. Separate search strategies were devised for the Cochrane database and Google Scholar. Each search was performed to include articles from the date of their inception to June 8, 2015.Objectives
Methods
In arthritis of the varus knee, a high tibial
osteotomy (HTO) redistributes load from the diseased medial compartment
to the unaffected lateral compartment. We report the outcome of 36 patients (33 men and three women)
with 42 varus, arthritic knees who underwent HTO and dynamic correction
using a Garches external fixator until they felt that normal alignment
had been restored. The mean age of the patients was 54.11 years
(34 to 68). Normal alignment was achieved at a mean 5.5 weeks (3
to 10) post-operatively. Radiographs, gait analysis and visual analogue
scores for pain were measured pre- and post-operatively, at one
year and at medium-term follow-up (mean six years; 2 to 10). Failure
was defined as conversion to knee arthroplasty. Pre-operative gait analysis divided the 42 knees into two equal
groups with high (17 patients) or low (19 patients) adductor moments.
After correction, a statistically significant (p <
0.001, At final follow-up, after a mean of 15.9 years (12 to 20), there
was a survivorship of 59% (95% CI 59.6 to 68.9) irrespective of
adductor moment group, with a mean time to conversion to knee arthroplasty
of 9.5 years (3 to 18; 95% confidence interval ± 2.5). HTO remains a useful option in the medium-term for the treatment
of medial compartment osteoarthritis of the knee but does not last
in the long-term. Cite this article:
The objective of this double-blind randomised controlled trial
was to assess whether ultrasound guidance improved the efficacy
of corticosteroid injections for Morton’s neuroma (MN). In all, 50 feet (40 patients) were recruited for this study but
five feet were excluded due to the patients declining further participation.
The mean age of the remaining 36 patients (45 feet) was 57.8 years
(standard deviation (Aims
Patients and Methods
The June 2015 Foot &
Ankle Roundup360 looks at: Syndesmosis and outcomes in ankle fracture; Ankle arthrodesis or arthroplasty: a complications-based analysis; Crosslinked polyethylene and ankle arthroplasty; Reducing screw removal in calcaneal osteotomies; Revisiting infection control policies; Chevron osteotomy: proximal or distal?; Ankle distraction for osteoarthritis
The highly cross-linked polyethylene Exeter RimFit flanged cemented
acetabular component was introduced in the United Kingdom in 2010.
This study aimed to examine the rates of emergence of radiolucent
lines observed when the Rimfit acetabular component was implanted
at total hip arthroplasty (THA) using two different techniques: firstly,
the ‘rimcutter’ technique in which the flange sits on a pre-prepared
acetabular rim; and secondly, the ‘trimmed flange’ technique in
which the flange is trimmed and the acetabular component is seated
inside the rim of the acetabulum. The radiographs of 150 THAs (75 ‘rimcutter’, 75 ‘trimmed flange’)
involving this component were evaluated to assess for radiolucencies
at the cement/bone interface by three observers. Aims
Patients and Methods
The aim of this study was to report a single surgeon series of
consecutive patients with moderate hallux valgus managed with a
percutaneous extra-articular reverse-L chevron (PERC) osteotomy. A total of 38 patients underwent 45 procedures. There were 35
women and three men. The mean age of the patients was 48 years (17
to 69). An additional percutaneous Akin osteotomy was performed
in 37 feet and percutaneous lateral capsular release was performed
in 22 feet. Clinical and radiological assessments included the type
of forefoot, range of movement, the American Orthopedic Foot and
Ankle (AOFAS) score, a subjective rating and radiological parameters. The mean follow-up was 59.1 months (45.9 to 75.2). No patients
were lost to follow-up.Aims
Patients and Methods