Advertisement for orthosearch.org.uk
Results 381 - 400 of 625
Results per page:
The Bone & Joint Journal
Vol. 97-B, Issue 4 | Pages 532 - 538
1 Apr 2015
Scott CEH Davidson E MacDonald DJ White TO Keating JF

Radiological evidence of post-traumatic osteoarthritis (PTOA) after fracture of the tibial plateau is common but end-stage arthritis which requires total knee arthroplasty is much rarer.

The aim of this study was to examine the indications for, and outcomes of, total knee arthroplasty after fracture of the tibial plateau and to compare this with an age and gender-matched cohort of TKAs carried out for primary osteoarthritis.

Between 1997 and 2011, 31 consecutive patients (23 women, eight men) with a mean age of 65 years (40 to 89) underwent TKA at a mean of 24 months (2 to 124) after a fracture of the tibial plateau. Of these, 24 had undergone ORIF and seven had been treated non-operatively. Patients were assessed pre-operatively and at 6, 12 and > 60 months using the Short Form-12, Oxford Knee Score and a patient satisfaction score.

Patients with instability or nonunion needed total knee arthroplasty earlier (14 and 13.3 months post-injury) than those with intra-articular malunion (50 months, p < 0.001). Primary cruciate-retaining implants were used in 27 (87%) patients. Complication rates were higher in the PTOA cohort and included wound complications (13% vs 1% p = 0.014) and persistent stiffness (10% vs 0%, p = 0.014). Two (6%) PTOA patients required revision total knee arthroplasty at 57 and 114 months. The mean Oxford knee score was worse pre-operatively in the cohort with primary osteoarthritis (18 vs 30, p < 0.001) but there were no significant differences in post-operative Oxford knee score or patient satisfaction (primary osteoarthritis 86%, PTOA 78%, p = 0.437).

Total knee arthroplasty undertaken after fracture of the tibial plateau has a higher rate of complications than that undertaken for primary osteoarthritis, but patient-reported outcomes and satisfaction are comparable.

Cite this article: Bone Joint J 2015;97-B:532–8.


Bone & Joint 360
Vol. 5, Issue 1 | Pages 23 - 24
1 Feb 2016


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 81 - 83
1 Jan 2016
Allen MM Pagnano MW

The cause of dissatisfaction following total knee arthroplasty (TKA) remains elusive. Much attention has been focused on static mechanical alignment as a basis for surgical success and optimising outcomes. More recently, research on both normal and osteoarthritic knees, as well as kinematically aligned TKAs, has suggested that other specific and dynamic factors may be more important than a generic target of 0 ± 3º of a neutral axis. Consideration of these other variables is necessary to understand ideal targets and move beyond generic results.

Cite this article: Bone Joint J 2016;98-B(1 Suppl A):81–3.


The Bone & Joint Journal
Vol. 98-B, Issue 4 | Pages 534 - 541
1 Apr 2016
Tsang STJ Mills LA Frantzias J Baren JP Keating JF Simpson AHRW

Aims

The aim of this study was to identify risk factors for the failure of exchange nailing in nonunion of tibial diaphyseal fractures.

Patients and Methods

A cohort of 102 tibial diaphyseal nonunions in 101 patients with a mean age of 36.9 years (15 to 74) were treated between January 1992 and December 2012 by exchange nailing. Of which 33 (32%) were initially open injuries. The median time from primary fixation to exchange nailing was 6.5 months (interquartile range (IQR) 4.3 to 9.8 months).

The main outcome measures were union, number of secondary fixation procedures required to achieve union and time to union.

Univariate analysis and multiple regression were used to identify risk factors for failure to achieve union.


The Bone & Joint Journal
Vol. 96-B, Issue 3 | Pages 312 - 318
1 Mar 2014
Meermans G Van Doorn WJ Koenraadt K Kats J

The orientation of the acetabular component can influence both the short- and long-term outcomes of total hip replacement (THR). We performed a prospective, randomised, controlled trial of two groups, comprising of 40 patients each, in order to compare freehand introduction of the component with introduction using the transverse acetabular ligament (TAL) as a reference for anteversion. Anteversion and inclination were measured on pelvic radiographs.

With respect to anteversion, in the freehand group 22.5% of the components were outside the safe zone versus 0% in the transverse acetabular ligament group (p = 0.002). The mean angle of anteversion in the freehand group was 21° (2° to 35°) which was significantly higher compared with 17° (2° to 25°) in the TAL group (p = 0.004). There was a significant difference comparing the variations of both groups (p = 0.008).

With respect to inclination, in the freehand group 37.5% of the components were outside the safe zone versus 20% in the TAL group (p = 0.14). There was no significant difference regarding the accuracy or variation of the angle of inclination when comparing the two groups.

The transverse acetabular ligament may be used to obtain the appropriate anteversion when introducing the acetabular component during THR, but not acetabular component inclination.

Cite this article: Bone Joint J 2014;96-B:312–18.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 4 | Pages 510 - 516
1 Apr 2012
Hickey BA Kempshall PJ Metcalfe AJ Forster MC

As part of the national initiative to reduce waiting times for joint replacement surgery in Wales, the Cardiff and Vale NHS Trust referred 224 patients to the NHS Treatment Centre in Weston-Super-Mare for total knee replacement (TKR). A total of 258 Kinemax TKRs were performed between November 2004 and August 2006. Of these, a total of 199 patients (232 TKRs, 90%) have been followed up for five years. This cohort was compared with 258 consecutive TKRs in 250 patients, performed at Cardiff and Vale Orthopaedic Centre (CAVOC) over a similar time period. The five year cumulative survival rate was 80.6% (95% confidence interval (CI) 74.0 to 86.0) in the Weston-Super-Mare cohort and 95.0% (95% CI 90.2 to 98.2) in the CAVOC cohort with revision for any reason as the endpoint. The relative risk for revision at Weston-Super-Mare compared with CAVOC was 3.88 (p < 0.001). For implants surviving five years, the mean Oxford knee scores (OKS) and mean EuroQol (EQ-5D) scores were similar (OKS: Weston-Super-Mare 29 (2 to 47) vs CAVOC 29.8 (3 to 48), p = 0.61; EQ-5D: Weston-Super-Mare 0.53 (-0.38 to 1.00) vs CAVOC 0.55 (-0.32 to 1.00), p = 0.79). Patients with revised TKRs had significantly lower Oxford knee and EQ-5D scores (p < 0.001).

The results show a higher revision rate for patients operated at Weston-Super-Mare Treatment Centre, with a reduction in functional outcome and quality of life after revision. This further confirms that patients moved from one area to another for joint replacement surgery fare poorly.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 124 - 128
1 Nov 2013
Hofmann AA Shaeffer JF McCandless JB Magee TH

Isolated patellofemoral arthritis is a common condition and there are varying opinions on the most effective treatments. Non-operative and operative treatments have failed to demonstrate effective long-term treatment for those in an advanced stage of the condition. Newer designs and increased technology in patellofemoral replacement (PFR) have produced more consistent outcomes. This has led to a renewed enthusiasm for this procedure. Newer PFR prostheses have addressed the patellar maltracking issues plaguing some of the older designs. Short-term results with contemporary prostheses and new technology are described here.

Cite this article: Bone Joint J 2013;95-B, Supple A:124–8.


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 229 - 236
1 Feb 2014
deVos MJ Verdonschot N Luites JWH Anderson PG Eygendaal D

We determined the short-term clinical outcome and migration within the bone of the humeral cementless component of the Instrumented Bone Preserving (IBP) total elbow replacement in a series of 16 patients. There were four men and 12 women with a mean age at operation of 63 years (40 to 81). Migration was calculated using radiostereometric analysis. There were no intra-operative complications and no revisions. At two-year follow-up, all patients showed a significant reduction in pain and functional improvement of the elbow (both p < 0.001). Although ten components (63%) showed movement or micromovement during the first six weeks, 14 (88%) were stable at one year post-operatively. Translation was primarily found in the proximal direction (median 0.3 mm (interquartile range (IQR) -0.09 to 0.8); the major rotational movement was an anterior tilt (median 0.7° (IQR 0.4° to 1.6°)). One malaligned component continued to migrate during the second year, and one component could not be followed beyond three months because migration had caused the markers to break off the prosthesis.

This study shows promising early results for the cementless humeral component of the IBP total elbow replacement. All patients had a good clinical outcome, and most components stabilised within six months of the operation.

Cite this article: Bone Joint J 2014;96-B:229–36.


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 54 - 59
1 Jan 2016
González Della Valle A Sharrock N Barlow M Caceres L Go G Salvati EA

We describe our technique and rationale using hybrid fixation for primary total hip arthroplasty (THA) at the Hospital for Special Surgery. Modern uncemented acetabular components have few screw holes, or no holes, polished inner surfaces, improved locking mechanisms, and maximised thickness and shell-liner conformity. Uncemented sockets can be combined with highly cross-linked polyethylene liners, which have demonstrated very low wear and osteolysis rates after ten to 15 years of implantation. The results of cement fixation with a smooth or polished surface finished stem have been excellent, virtually eliminating complications seen with cementless fixation like peri-operative femoral fractures and thigh pain. Although mid-term results of modern cementless stems are encouraging, the long-term data do not show reduced revision rates for cementless stems compared with cemented smooth stems. In this paper we review the conduct of a hybrid THA, with emphasis on pre-operative planning, surgical technique, hypotensive epidural anaesthesia, and intra-operative physiology.

Cite this article: Bone Joint J 2016;98-B(1 Suppl A):54–9.


Bone & Joint 360
Vol. 5, Issue 1 | Pages 2 - 8
1 Feb 2016
Bryson D Shivji F Price K Lawniczak D Chell J Hunter J


The Bone & Joint Journal
Vol. 97-B, Issue 10_Supple_A | Pages 16 - 19
1 Oct 2015
Oussedik S Abdel MP Cross MB Haddad FS

Many aspects of total knee arthroplasty have changed since its inception. Modern prosthetic design, better fixation techniques, improved polyethylene wear characteristics and rehabilitation, have all contributed to a large change in revision rates. Arthroplasty patients now expect longevity of their prostheses and demand functional improvement to match. This has led to a re-examination of the long-held belief that mechanical alignment is instrumental to a successful outcome and a focus on restoring healthy joint kinematics. A combination of kinematic restoration and uncemented, adaptable fixation may hold the key to future advances.

Cite this article: Bone Joint J 2015;97-B(10 Suppl A):16–19.


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 378 - 383
1 Mar 2013
Kim BS Choi WJ Kim J Lee JW

We report the incidence and intensity of persistent pain in patients with an otherwise uncomplicated total ankle replacement (TAR). Arthroscopic debridement was performed in selected cases and the clinical outcome was analysed.

Among 120 uncomplicated TARs, there was persistent pain with a mean visual analogue scale (VAS) of 2.7 (0 to 8). The intensity of pain decreased in 115 ankles (95.8%). Exercise or walking for more than 30 minutes was the most common aggravating factor (62 ankles, 68.1%). The character of the pain was most commonly described as dull (50 ankles, 54.9%) and located on the medial aspect of the joint (43 ankles, 47.3%).

A total of seven ankles (5.8%) underwent subsequent arthroscopy. These patients had local symptoms and a VAS for pain ≥ 7 on exertion. Impingement with fibrosis and synovitis was confirmed. After debridement, the median VAS decreased from 7 to 3 and six patients were satisfied. The median VAS for pain and the American Orthopaedic Foot and Ankle Society score of the ankles after debridement was similar to that of the uncomplicated TARs (p = 0.496 and p = 0.066, respectively).

Although TAR reduces the intensity of pain, residual pain is not infrequent even in otherwise uncomplicated TARs and soft-tissue impingement is the possible cause.

Cite this article: Bone Joint J 2013;95-B:378–83.


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1667 - 1672
1 Dec 2013
Oh C Apivatthakakul T Oh J Kim J Lee H Kyung H Baek S Jung G

Although gradual bone transport may permit the restoration of large-diameter bones, complications are common owing to the long duration of external fixation. In order to reduce such complications, a new technique of bone transport involving the use of an external fixator and a locking plate was devised for segmental tibial bone defects.

A total of ten patients (nine men, one woman) with a mean age at operation of 40.4 years (16 to 64) underwent distraction osteogenesis with a locking plate to treat previously infected post-traumatic segmental tibial defects. The locking plate was fixed percutaneously to bridge proximal and distal segments, and was followed by external fixation. After docking, percutaneous screws were fixed at the transported segment through plate holes. At the same time, bone grafting was performed at the docking site with the external fixator removed.

The mean defect size was 5.9 cm (3.8 to 9.3) and mean external fixation index was 13.4 days/cm (11.8 to 19.5). In all cases, primary union of the docking site and distraction callus was achieved, with an excellent bony result. There was no recurrence of deep infection or osteomyelitis, and with the exception of one patient with a pre-existing peroneal nerve injury, all achieved an excellent or good functional result.

With short external fixation times and low complication rates, bone transport with a locking plate could be recommended for patients with segmental tibial defects.

Cite this article: Bone Joint J 2013;95-B:1667–72.


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 706 - 713
1 May 2013
Westberry DE Davids JR Anderson JP Pugh LI Davis RB Hardin JW

At our institution surgical correction of symptomatic flat foot deformities in children has been guided by a paradigm in which radiographs and pedobarography are used in the assessment of outcome following treatment. Retrospective review of children with symptomatic flat feet who had undergone surgical correction was performed to assess the outcome and establish the relationship between the static alignment and the dynamic loading of the foot.

A total of 17 children (21 feet) were assessed before and after correction of soft-tissue contractures and lateral column lengthening, using standardised radiological and pedobarographic techniques for which normative data were available.

We found significantly improved static segmental alignment of the foot, significantly improved mediolateral dimension foot loading, and worsened fore-aft foot loading, following surgical treatment. Only four significant associations were found between radiological measures of static segmental alignment and dynamic loading of the foot.

Weakness of the plantar flexors of the ankle was a common post-operative finding. Surgeons should be judicious in the magnitude of lengthening of the plantar flexors that is undertaken and use techniques that minimise subsequent weakening of this muscle group.

Cite this article: Bone Joint J 2013;95-B:706–13.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 145 - 150
1 Feb 2011
Ng CY McQueen MM

The fracture most commonly treated by orthopaedic surgeons is that of the distal radius. However, as yet there is no consensus on what constitutes an ‘acceptable’ radiological position before or after treatment. This should be defined as the position that will predict good function in the majority of cases. In this paper we review the radiological indices that can be measured in fractures of the distal radius and try to identify potential predictors of functional outcome. In patients likely to have high functional demands, we recommend that the articular reconstruction be achieved with less than 2 mm of gap or step-off, the radius be restored to within 2 mm of its normal length, and that carpal alignment be restored. The ultimate aim of treatment is a pain-free, mobile wrist joint without functional limitation.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1223 - 1231
1 Sep 2011
Babazadeh S Dowsey MM Swan JD Stoney JD Choong PFM

The role of computer-assisted surgery in maintaining the level of the joint in primary knee joint replacement (TKR) has not been well defined. We undertook a blinded randomised controlled trial comparing joint-line maintenance, functional outcomes, and quality-of-life outcomes between patients undergoing computer-assisted and conventional TKR. A total of 115 patients were randomised (computer-assisted, n = 55; conventional, n = 60).

Two years post-operatively no significant correlation was found between computer-assisted and conventional surgery in terms of maintaining the joint line. Those TKRs where the joint line was depressed post-operatively improved the least in terms of functional scores. No difference was detected in terms of quality-of-life outcomes. Change in joint line was found to be related to change in alignment. Change in alignment significantly affects change in joint line and functional scores.


Bone & Joint 360
Vol. 4, Issue 4 | Pages 8 - 11
1 Aug 2015
McBride A Nicol S Monsell F


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1358 - 1363
1 Oct 2015
Hooper N Snell D Hooper G Maxwell R Frampton C

This study reports on the first 150 consecutive Oxford cementless unicompartmental knee arthroplasties (UKA) performed in an independent centre (126 patients). All eligible patients had functional scores (Oxford knee score and high activity arthroplasty score) recorded pre-operatively and at two- and five-years of follow-up. Fluoroscopically aligned radiographs were taken at five years and analysed for any evidence of radiolucent lines (RLLs), subsidence or loosening. The mean age of the cohort was 63.6 years (39 to 86) with 81 (53.1%) males. Excellent functional scores were maintained at five years and there were no progressive RLLs demonstrated on radiographs. Two patients underwent revision to a total knee arthroplasty giving a revision rate of 0.23/100 (95% confidence interval 0.03 to 0.84) component years with overall component survivorship of 98.7% at five years. There were a further four patients who underwent further surgery on the same knee, two underwent bearing exchanges for dislocation and two underwent lateral UKAs for disease progression. This was a marked improvement from other UKAs reported in New Zealand Joint Registry data and supports the designing centre’s early results.

Cite this article: Bone Joint J 2015;97-B:1358–63.


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1096 - 1101
1 Aug 2015
Oizumi N Suenaga N Yoshioka C Yamane S

To prevent insufficiency of the triceps after total elbow arthroplasty, we have, since 2008, used a triceps-sparing ulnar approach. This study evaluates the clinical results and post-operative alignment of the prosthesis using this approach.

We reviewed 25 elbows in 23 patients. There were five men and 18 women with a mean age of 69 years (54 to 83). There were 18 elbows with rheumatoid arthritis, six with a fracture or pseudoarthrosis and one elbow with osteoarthritis.

Post-operative complications included one intra-operative fracture, one elbow with heterotopic ossification, one transient ulnar nerve palsy, and one elbow with skin necrosis, but no elbow was affected by insufficiency of the triceps.

Patients were followed for a mean of 42 months (24 to 77). The mean post-operative Japanese Orthopaedic Association Elbow Score was 90.8 (51 to 100) and the mean Mayo Elbow Performance score 93.8 (65 to 100). The mean post-operative flexion/extension of the elbow was 135°/-8°. The Manual Muscle Testing score of the triceps was 5 in 23 elbows and 2 in two elbows (one patient). The mean alignment of the implants examined by 3D-CT was 2.8° pronation (standard deviation (sd) 5.5), 0.3° valgus (sd 2.7), and 0.7° extension (sd 3.2) for the humeral component, and 9.3° pronation (sd 9.7), 0.3° valgus (sd 4.0), and 8.6° extension (sd 3.1) for the ulnar component. There was no radiolucent line or loosening of the implants on the final radiographs.

The triceps-sparing ulnar approach allows satisfactory alignment of the implants, is effective in preventing post-operative triceps insufficiency, and gives satisfactory short-term results.

Cite this article: 2015;97-B:1096–1101.


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 354 - 359
1 Mar 2013
Chareancholvanich K Narkbunnam R Pornrattanamaneewong C

Patient-specific cutting guides (PSCGs) are designed to improve the accuracy of alignment of total knee replacement (TKR). We compared the accuracy of limb alignment and component positioning after TKR performed using PSCGs or conventional instrumentation. A total of 80 patients were randomised to undergo TKR with either of the different forms of instrumentation, and radiological outcomes and peri-operative factors such as operating time were assessed. No significant difference was observed between the groups in terms of tibiofemoral angle or femoral component alignment. Although the tibial component in the PSCGs group was measurably closer to neutral alignment than in the conventional group, the size of the difference was very small (89.8° (sd 1.2) vs 90.5° (sd 1.6); p = 0.030). This new technology slightly shortened the bone-cutting time by a mean of 3.6 minutes (p < 0.001) and the operating time by a mean 5.1 minutes (p = 0.019), without tangible differences in post-operative blood loss (p = 0.528) or need for blood transfusion (p = 0.789). This study demonstrated that both PSCGs and conventional instrumentation restore limb alignment and place the components with the similar accuracy. The minimal advantages of PSCGs in terms of consistency of alignment or operative time are unlikely to be clinically relevant.

Cite this article: Bone Joint J 2013;95-B:354–9.