Advertisement for orthosearch.org.uk
Results 381 - 400 of 454
Results per page:
The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 498 - 503
1 Apr 2013
Yammine K Harvey A

We report a systematic review and meta-analysis of published randomised and quasi-randomised trials evaluating the efficacy of pre-operative skin antisepsis and cleansing techniques in reducing foot and ankle skin flora. The post-preparation culture number (Post-PCN) was the primary outcome. The data were evaluated using a modified version of the Cochrane Collaboration’s tool. We identified eight trials (560 participants, 716 feet) that met the inclusion criteria. There was a significant difference in the proportions of Post-PCN between hallux nailfold (HNF) and toe web spaces (TWS) sites: 0.47 vs 0.22, respectively (95% confidence interval (CI) 0.182937 to 0.304097; p < 0.0001).

Meta-analyses showed that alcoholic chlorhexidine had better efficacy than alcoholic povidone-iodine (PI) at HNF sites (risk difference 0.19 (95% CI 0.08 to 0.30); p = 0.0005); a two-step intervention using PI scrub and paint (S& P) followed by alcohol showed significantly better efficacy over PI (S& P) alone at TWS sites (risk difference 0.13 (95% CI 0.02 to 0.24); p = 0.0169); and a two-step intervention using chlorhexidine scrub followed by alcohol showed significantly better efficacy over PI (S& P) alone at the combined (HNF with TWS) sites (risk difference 0.27 (95% CI 0.13 to 0.40); p < 0.0001). No significant difference was found between cleansing techniques.

Cite this article: Bone Joint J 2013;95-B:498–503.


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 396 - 400
1 Mar 2013
Rhee SH Kim J Lee YH Gong HS Lee HJ Baek GH

The purpose of this study was to evaluate the risk of late displacement after the treatment of distal radial fractures with a locking volar plate, and to investigate the clinical and radiological factors that might correlate with re-displacement. From March 2007 to October 2009, 120 of an original cohort of 132 female patients with unstable fractures of the distal radius were treated with a volar locking plate, and were studied over a follow-up period of six months. In the immediate post-operative and final follow-up radiographs, late displacement was evaluated as judged by ulnar variance, radial inclination, and dorsal angulation. We also analysed the correlation of a variety of clinical and radiological factors with re-displacement. Ulnar variance was significantly overcorrected (p < 0.001) while radial inclination and dorsal angulation were undercorrected when compared statistically (p <  0.001) with the unaffected side in the immediate post-operative stage. During follow-up, radial shortening and dorsal angulation progressed statistically, but none had a value beyond the acceptable range. Bone mineral density measured at the proximal femur and the position of the screws in the subchondral region, correlated with slight progressive radial shortening, which was not clinically relevant.

Volar locking plating of distal radial fractures is a reliable form of treatment without substantial late displacement.

Cite this article: Bone Joint J 2013;95-B:396–400.


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 401 - 406
1 Mar 2013
Rebolledo BJ Gladnick BP Unnanuntana A Nguyen JT Kepler CK Lane JM

This is a prospective randomised study comparing the clinical and radiological outcomes of uni- and bipedicular balloon kyphoplasty for the treatment of osteoporotic vertebral compression fractures. A total of 44 patients were randomised to undergo either uni- or bipedicular balloon kyphoplasty. Self-reported clinical assessment using the Oswestry Disability Index, the Roland-Morris Disability questionnaire and a visual analogue score for pain was undertaken pre-operatively, and at three and twelve months post-operatively. The vertebral height and kyphotic angle were measured from pre- and post-operative radiographs. Total operating time and the incidence of cement leakage was recorded for each group.

Both uni- and bipedicular kyphoplasty groups showed significant within-group improvements in all clinical outcomes at three months and twelve months after surgery. However, there were no significant differences between the groups in all clinical and radiological outcomes. Operating time was longer in the bipedicular group (p < 0.001). The incidence of cement leakage was not significantly different in the two groups (p = 0.09).

A unipedicular technique yielded similar clinical and radiological outcomes as bipedicular balloon kyphoplasty, while reducing the length of the operation. We therefore encourage the use of a unipedicular approach as the preferred surgical technique for the treatment of osteoporotic vertebral compression fractures.

Cite this article: Bone Joint J 2013;95-B:401–6.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 158 - 163
1 Feb 2011
Baker RP Pollard TCB Eastaugh-Waring SJ Bannister GC

We compared the medium-term clinical and radiological results of hybrid total hip replacement (THR) with metal-on-metal Birmingham hip resurfacing (BHR) in two groups of 54 young patients matched for age, gender, body mass index and pre-operative levels of activity.

The clinical outcome was assessed by the University of California, Los Angeles (UCLA) activity score, the Oxford Hip Score (OHS) and the EuroQol scores. Radiologically, all hips were assessed for migration and osteolysis, the hybrid THRs for polyethylene wear and the BHRs for a pedestal sign. The mean follow-up of the patients with a hybrid THR was ten years and for those with a BHR, nine years. Four patients with a hybrid THR and one with a BHR had died. In each group five were lost to follow-up. The revision rate of the hybrid THRs was 16.7% (9 of 54) and of the BHRs 9.3% (5 of 54) (p = 0.195). Radiographs of a further eight hybrid THRs demonstrated wear and osteolysis, and they await revision (p = 0.008). Of the unrevised BHRs 90% had radiological changes, of which approximately 50% had progressed over the previous four years. All hybrid THRs demonstrated linear polyethylene wear with a mean of 1.24 mm (0.06 to 3.03). The BHRs recorded superior OHS (p = 0.013), UCLA (p = 0.008), and EuroQol visual analogue scores (p = 0.009).

After nine years, patients with BHRs remained more active and had a lower rate of revision than those with hybrid THRs. Both groups demonstrated progressive radiological changes at medium-term follow-up.


Bone & Joint 360
Vol. 2, Issue 1 | Pages 16 - 19
1 Feb 2013

The February 2013 Knee Roundup360 looks at: mobile-bearing TKRs; arthroscopic ACL reconstruction; the use of chondrocytes for osteochondral defects; ACL reconstruction and the return to pivoting sports; ACLs and the MOON study; the benefit of knee navigation; and trabecular metal.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 8 | Pages 1088 - 1092
1 Aug 2011
Lizaur A Sanz-Reig J Gonzalez-Parreño S

The purpose of this study was to review the long-term outcomes of a previously reported prospective series of 46 type III acromioclavicular dislocations. These were treated surgically with temporary fixation of the acromioclavicular joint with wires, repair of the acromioclavicular ligaments, and overlapped suture of the deltoid and trapezius muscles. Of the 46 patients, one had died, four could not be traced, and three declined to return for follow-up, leaving 38 patients in the study. There were 36 men and two women, with a mean age at follow-up of 57.3 years (41 to 71). The mean follow-up was 24.2 years (21 to 26).

Patients were evaluated using the Imatani and University of California, Los Angeles (UCLA) scoring systems. Their subjective status was assessed using the Disabilities of the Arm, Shoulder and Hand and Simple Shoulder Test questionnaires, and a visual analogue scale for patient satisfaction. The examination included radiographs of the shoulder.

At a follow-up of 21 years, the results were satisfactory in 35 (92.1%) patients and unsatisfactory in three (7.9%). In total, 35 patients (92.1%) reported no pain, one slight pain, and two moderate pain. All except two patients had a full range of shoulder movement compared with the opposite side. Unsatisfactory results were the result of early redisplacement in two patients, and osteoarthritis without redisplacement in one. According to the Imatani and UCLA scores, there was no difference between the operated shoulder and the opposite shoulder (p > 0.05). Given the same situation, 35 (92.1%) patients would opt for the same surgical treatment again.

Operative treatment of type III acromioclavicular joint injuries produces satisfactory long-term results.


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 210 - 216
1 Feb 2013
Balain B Jaiswal A Trivedi JM Eisenstein SM Kuiper JH Jaffray DC

The revised Tokuhashi, Tomita and modified Bauer scores are commonly used to make difficult decisions in the management of patients presenting with spinal metastases. A prospective cohort study of 199 consecutive patients presenting with spinal metastases, treated with either surgery and/or radiotherapy, was used to compare the three systems. Cox regression, Nagelkerke’s R2 and Harrell’s concordance were used to compare the systems and find their best predictive items. The three systems were equally good in terms of overall prognostic performance. Their most predictive items were used to develop the Oswestry Spinal Risk Index (OSRI), which has a similar concordance, but a larger coefficient of determination than any of these three scores. A bootstrap procedure was used to internally validate this score and determine its prediction optimism.

The OSRI is a simple summation of two elements: primary tumour pathology (PTP) and general condition (GC): OSRI = PTP + (2 – GC).

This simple score can predict life expectancy accurately in patients presenting with spinal metastases. It will be helpful in making difficult clinical decisions without the delay of extensive investigations.

Cite this article: Bone Joint J 2013;95-B:210–16.


Bone & Joint Research
Vol. 1, Issue 11 | Pages 310 - 314
1 Nov 2012
Griffin XL Achten J Parsons N Boardman F Griffiths F Costa ML

Fractures of the proximal femur are one of the greatest challenges facing the medical community, constituting a heavy socioeconomic burden worldwide. The National Hip Fracture Audit currently provides a framework for service evaluation. This evaluation is based upon the assessment of process rather than assessment of patient-centred outcome and therefore it fails to provide meaningful data regarding the clinical effectiveness of treatments. This study aims to capture data from the cohort of patients who present with a fracture of the proximal femur at a single United Kingdom Major Trauma Centre. Patient-centred outcomes will be recorded and provide a baseline cohort within which to test the clinical effectiveness of experimental interventions.


The Bone & Joint Journal
Vol. 95-B, Issue 1 | Pages 115 - 121
1 Jan 2013
Jenkins PJ Clement ND Hamilton DF Gaston P Patton JT Howie CR

The aim of this study was to perform a cost–utility analysis of total hip (THR) and knee replacement (TKR). Arthritis is a disabling condition that leads to long-term deterioration in quality of life. Total joint replacement, despite being one of the greatest advances in medicine of the modern era, has recently come under scrutiny. The National Health Service (NHS) has competing demands, and resource allocation is challenging in times of economic restraint. Patients who underwent THR (n = 348) or TKR (n = 323) between January and July 2010 in one Scottish region were entered into a prospective arthroplasty database. A health–utility score was derived from the EuroQol (EQ-5D) score pre-operatively and at one year, and was combined with individual life expectancy to derive the quality-adjusted life years (QALYs) gained. Two-way analysis of variance was used to compare QALYs gained between procedures, while controlling for baseline differences. The number of QALYs gained was higher after THR than after TKR (6.5 vs 4.0 years, p < 0.001). The cost per QALY for THR was £1372 compared with £2101 for TKR. The predictors of an increase in QALYs gained were poorer health before surgery (p < 0.001) and younger age (p < 0.001). General health (EQ-5D VAS) showed greater improvement after THR than after TKR (p < 0.001). This study provides up-to-date cost-effectiveness data for total joint replacement. THR and TKR are extremely effective both clinically and in terms of cost effectiveness, with costs that compare favourably to those of other medical interventions.

Cite this article: Bone Joint J 2013;95-B:115–21.


The Bone & Joint Journal
Vol. 95-B, Issue 1 | Pages 23 - 30
1 Jan 2013
Kiernan S Hermann KL Wagner P Ryd L Flivik G

Progressive retroversion of a cemented stem is predictive of early loosening and failure. We assessed the relationship between direct post-operative stem anteversion, measured with CT, and the resulting rotational stability, measured with repeated radiostereometric analysis over ten years. The study comprised 60 cemented total hip replacements using one of two types of matt collared stem with a rounded cross-section. The patients were divided into three groups depending on their measured post-operative anteversion (< 10°, 10° to 25°, >  25°). There was a strong correlation between direct post-operative anteversion and later posterior rotation. At one year the < 10° group showed significantly more progressive retroversion together with distal migration, and this persisted to the ten-year follow-up. In the < 10° group four of ten stems (40%) had been revised at ten years, and an additional two stems (20%) were radiologically loose. In the ‘normal’ (10° to 25°) anteversion group there was one revised (3%) and one loose stem (3%) of a total of 30 stems, and in the > 25° group one stem (5%) was revised and another loose (5%) out of 20 stems. This poor outcome is partly dependent on the design of this prosthesis, but the results strongly suggest that the initial rotational position of cemented stems during surgery affects the subsequent progressive retroversion, subsidence and eventual loosening. The degree of retroversion may be sensitive to prosthetic design and stem size, but < 10° of anteversion appears deleterious to the long-term outcome for cemented hip prosthetic stems.

Cite this article: Bone Joint J 2013;95-B:23–30.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1067 - 1070
1 Aug 2012
Melton JTK Mayahi R Baxter SE Facek M Glezos C

A consecutive series of patients with a hydroxyapatite-coated uncemented total knee replacement (TKR) performed by a single surgeon between 1992 and 1995 was analysed. All patients were invited for clinical review and radiological assessment. Revision for aseptic loosening was the primary outcome. Assessment was based on the Knee Society clinical score (KSS) and an independent radiological analysis. Of 471 TKRs performed in 356 patients, 432 TKRs in 325 patients were followed for a mean of 16.4 years (15 to 18). The 39 TKRs in 31 patients lost to follow-up had a mean KSS of 176 (148 to 198) at a mean of ten years. There were revisions in 26 TKRs (5.5%), of which 11 (2.3%) were for aseptic loosening. Other further surgery was carried out on 49 TKRs (10.4%) including patellar resurfacing in 20, arthrolysis in 19, manipulation under anaesthetic in nine and extensor mechanism reconstruction in one.

Survivorship at up to 18 years without aseptic loosening was 96% (95% confidence interval 91.9 to 98.1), at which point the mean KSS was 176 (134 to 200). Of 110 knees that underwent radiological evaluation, osteolysis was observed in five (4.5%), one of which was revised.

These data indicate that uncemented hydroxyapatite-coated TKR can achieve favourable long-term survivorship, at least as good as that of cemented designs.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1246 - 1252
1 Sep 2012
Penning LIF de Bie RA Walenkamp GHIM

A total of 159 patients (84 women and 75 men, mean age of 53 (20 to 87)) with subacromial impingement were randomised to treatment with subacromial injections using lidocaine with one of hyaluronic acid (51 patients), corticosteroid (53 patients) or placebo (55 patients). Patients were followed up for 26 weeks. The primary outcome was pain on a visual analogue score (VAS), and secondary outcomes included the Constant Murley score, shoulder pain score, functional mobility score, shoulder disability questionnaire and pain-specific disability score. The different outcome measures showed similar results. After three, six and 12 weeks corticosteroid injections were superior to hyaluronic acid injections and only at six weeks significantly better than placebo injections. The mean short-term reduction in pain on the VAS score at 12 weeks was 7% (sd 2.7; 97.5% confidence interval (CI) 0.207 to 1.55; p = 0.084) in the hyaluronic acid group, 28% (sd 2.8; 97.5% CI 1.86 to 3.65; p < 0.001) in the corticosteroid group and 23% (sd 3.23; 97.5% CI 1.25 to 3.26; p < 0.001) in the placebo group. At 26 weeks there was a reduction in pain in 63% (32 of 51) of patients in the hyaluronic acid group, 72% (38 of 53) of those in the corticosteroid group and 69% (38 of 55) of those in the placebo group.

We were not able to show a convincing benefit from hyaluronic acid injections compared with corticosteroid or placebo injections. Corticosteroid injections produced a significant reduction in pain in the short term (three to 12 weeks), but in the long term the placebo injection produced the best results.


Bone & Joint 360
Vol. 1, Issue 1 | Pages 15 - 16
1 Feb 2012


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 6 | Pages 793 - 798
1 Jun 2012
Bianchi A Martinelli N Sartorelli E Malerba F

The Bologna–Oxford (BOX) total ankle replacement (TAR) was developed with the aim of achieving satisfactory pain-free movement of the ankle. To date, only one single multicentre study has reported its clinical results. The aim of this study was to conduct an independent review of its mid-term results.

We retrospectively reviewed a total of 60 prospectively followed patients in whom 62 BOX TARs had been implanted between 2004 and 2008. We used the American Orthopedic Foot and Ankle Society (AOFAS) score to assess the clinical results. Standardised radiographs taken at the time of final follow-up were analysed by two observers. The overall survival was 91.9% at a mean follow-up of 42.5 months (24 to 71). The mean AOFAS score had improved from 35.1 points (sd 16.6; 4 to 73) pre-operatively to 78.0 (sd 10.7; 57 to 100) at final follow-up (p < 0.01). Tibial radiolucencies < 2 mm in width were seen around 16 TARs. Talar radiolucencies < 2 mm were seen around four TARs. A total of 47 patients (78.3%) were very satisfied or satisfied with the outcome. Five patients required revision for functional limitation or continuing pain.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 665 - 677
1 May 2011
Sköldenberg OG Salemyr MO Bodén HS Lundberg A Ahl TE Adolphson PY

Our aim in this pilot study was to evaluate the fixation of, the bone remodelling around, and the clinical outcome after surgery of a new, uncemented, fully hydroxyapatite-coated, collared and tapered femoral component, designed specifically for elderly patients with a fracture of the femoral neck.

We enrolled 50 patients, of at least 70 years of age, with an acute displaced fracture of the femoral neck in this prospective single-series study. They received a total hip replacement using the new component and were followed up regularly for two years.

Fixation was evaluated by radiostereometric analysis and bone remodelling by dual-energy x-ray absorptiometry. Hip function and the health-related quality of life were assessed using the Harris hip score and the EuroQol-5D.

Up to six weeks post-operatively there was a mean subsidence of 0.2 mm (−2.1 to +0.5) and a retroversion of a mean of 1.2° (−8.2° to +1.5°). No component migrated after three months. The patients had a continuous loss of peri-prosthetic bone which amounted to a mean of 16% (−49% to +10%) at two years. The mean Harris hip score was 82 (51 to 100) after two years.

The two-year results from this pilot study indicate that this new, uncemented femoral component can be used for elderly patients with osteoporotic fractures of the femoral neck.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 8 | Pages 1013 - 1018
1 Aug 2009
Agarwala S Shah S Joshi VR

The use of bisphosphonates in the treatment of avascular necrosis of the femoral head is an encouraging but relatively new option with most published data being derived from small trials with limited follow-up. We present a clinicoradiological analysis of 395 hips with avascular necrosis which were treated with oral alendronate for three years with a mean follow-up of four years (1 to 8).

Our results show an improvement in the clinical function, a reduction in the rate of collapse and a decrease in the requirement for total hip replacement, compared with the findings of other studies in which no treatment was given. This improvement is particularly marked if the treatment is begun in the pre-collapse stages of the disease. Even in Ficat stage-III hips some benefit was obtained from treatment with alendronate by at least a delay in the need for total hip replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 6 | Pages 787 - 792
1 Jun 2012
Thomsen MG Husted H Bencke J Curtis D Holm G Troelsen A

The purpose of this study was to investigate whether a gender-specific high-flexion posterior-stabilised (PS) total knee replacement (TKR) would offer advantages over a high-flex PS TKR regarding range of movement (ROM), ‘feel’ of the knee, pain and satisfaction, as well as during activity. A total of 24 female patients with bilateral osteoarthritis entered this prospective, blind randomised trial in which they received a high-flex PS TKR in one knee and a gender-specific high-flexion PS TKR in the other knee. At follow-up, patients were assessed clinically measuring ROM, and questioned about pain, satisfaction and daily ‘feel’ of each knee. Patients underwent gait analysis pre-operatively and at one year, which yielded kinematic, kinetic and temporospatial parameters indicative of knee function during gait. At final follow-up we found no statistically significant differences in ROM (p = 0.82). The median pain score was 0 (0 to 8) in both groups (p = 0.95). The median satisfaction score was 9 (4 to 10) in the high-flex group and 8 (0 to 10) in the gender-specific group (p = 0.98). The median ‘feel’ score was 9 (3 to 10) in the high-flex group and 8 (0 to 10) in the gender-specific group (p = 0.66). Gait analysis showed no statistically significant differences between the two prosthetic designs in any kinematic, kinetic or temporospatial parameters.

Both designs produced good clinical results with significant improvements in several gait parameters without evidence of any advantage in the gender-specific design.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 3 | Pages 308 - 314
1 Mar 2012
Ito H Tanino H Yamanaka Y Nakamura T Takahashi D Minami A Matsuno T

We have previously described the mid- to long-term results of conventional simple varus intertrochanteric osteotomy for osteonecrosis of the femoral head, showing that 19 of the 26 hips had good or excellent results. We extended the follow-up to a mean of 18.1 years (10.5 to 26) including a total of 34 hips in 28 patients, with a mean age at surgery of 33 years (19 to 53). There were 18 men and ten women and 25 hips (74%) had a satisfactory result with a Harris hip score ≥ 80. In all, six hips needed total hip replacement (THR) or hemiarthroplasty. The collapse of the femoral head or narrowing of the joint space was found to have progressed in nine hips (26%). Leg shortening after osteotomy was a mean of 19 mm (8 to 36). With conversion to THR or hemiarthroplasty as the endpoint, the ten-year survival rate was 88.2% (95% confidence interval (CI) 82.7 to 93.7) and the 20-year survival rate was 79.7% (95% CI 72.1 to 87.3); four hips were converted at ten years and other two hips were converted at 20 years.

Shortening of the leg after osteotomy remains a concern; however, the conventional varus half-wedge osteotomy provides favourable long-term results in hips with less than two-thirds of the medial part of the femoral head affected by necrotic bone and with normal bone superolaterally.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 7 | Pages 889 - 895
1 Jul 2009
Gandhi R Tsvetkov D Davey JR Mahomed NN

Using meta-analysis we compared the survival and clinical outcomes of cemented and uncemented techniques in primary total knee replacement. We reviewed randomised controlled trials and observational studies comparing cemented and uncemented fixation. Our primary outcome was survival of the implant free of aseptic loosening. Our secondary outcome was joint function as measured by the Knee Society score. We identified 15 studies that met our final eligibility criteria. The combined odds ratio for failure of the implant due to aseptic loosening for the uncemented group was 4.2 (95% confidence interval (CI) 2.7 to 6.5) (p < 0.0001). Subgroup analysis of data only from randomised controlled trials showed no differences between the groups for odds of aseptic loosening (odds ratio 1.9, 95% CI 0.55 to 6.40, p = 0.314). The weighted mean difference for the Knee Society score was 0.005 (95% CI −0.26 to 0.26) (p = 0.972).

There was improved survival of the cemented compared to uncemented implants, with no statistically significant difference in the mean Knee Society score between groups for all pooled data.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 4 | Pages 497 - 503
1 Apr 2012
Bercovy M Beldame J Lefebvre B Duron A

This prospective study compares the outcome of 157 hydroxyapatite (HA)-coated tibial components with 164 cemented components in the ROCC Rotating Platform total knee replacement in 291 patients. The mean follow-up was 7.6 years (5.2 to 11). There were two revisions for loosening: one for an HA-coated and one for a cemented tibial component. Radiological evaluation demonstrated no radiolucent lines with the HA-coated femoral components. A total of three HA-coated tibial components exhibited radiolucent lines at three months post-operatively and these disappeared after three further months of protected weight-bearing. With HA-coated components the operating time was shorter (p <  0.006) and the radiological assessment of the tibial interface was more stable (p < 0.01). Using revision for aseptic loosening of the tibial component as the end point, the survival rates at nine years was identical for both groups at 99.1%.

Our results suggest that HA-coated components perform at least as well as the same design with cemented components and compare favourably with those of series describing cemented or porous-coated knee replacements, suggesting that fixation of both components with hydroxyapatite is a reliable option in primary total knee replacement.