Advertisement for orthosearch.org.uk
Results 21 - 40 of 1510
Results per page:
The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1040 - 1044
1 Aug 2013
Kazi HA Perera JR Gillott E Carroll FA Briggs TWR

We prospectively assessed the efficacy of a ceramic-on-metal (CoM) hip bearing with uncemented acetabular and femoral components in which cobalt­–chrome acetabular liners and alumina ceramic heads were used.

The cohort comprised 94 total hip replacements (THRs) in 83 patients (38 women and 45 men) with a mean age of 58 years (42 to 70). Minimum follow-up was two years. All patients had pre- and post-operative assessment using the Western Ontario and McMaster Universities osteoarthritis index (WOMAC), Oxford hip score and Short-Form 12 scores. All showed a statistically significant improvement from three months post-operatively onwards (all p < 0.001).

After two years whole blood metal ion levels were measured and chromosomal analysis was performed. The levels of all metal ions were elevated except vanadium. Levels of chromium, cobalt, molybdenum and titanium were significantly higher in patients who underwent bilateral THR compared with those undergoing unilateral THR (p < 0.001). Chromosomal analysis demonstrated both structural and aneuploidy mutations. There were significantly more breaks and losses than in the normal population (p < 0.001). There was no significant difference in chromosomal aberration between those undergoing unilateral and bilateral procedures (all analyses p ≥ 0.62).

The use of a CoM THR is effective clinically in the short-term, with no concerns, but the significance of high metal ion levels and chromosomal aberrations in the long-term remains unclear.

Cite this article: Bone Joint J 2013;95-B:1040–44.


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 1 | Pages 49 - 52
1 Jan 1993
Spiers A Meagher T Ostlere S Wilson D Dodd C

We made a prospective study of 58 patients with suspected internal derangement of the knee. They were examined by magnetic resonance imaging using 3-D gradient echo intermediate-weighted studies before having an arthroscopy. The preoperative clinical assessment was found to have a diagnostic sensitivity of 77% and a specificity of 43%, compared with 100% and 63% respectively for magnetic resonance imaging. Comparison of magnetic resonance imaging and arthroscopy confirmed the accuracy of magnetic resonance imaging in the diagnosis of internal derangement but the results for articular cartilage lesions were much less good, with a sensitivity of only 18% but a specificity of 100%. Acceptance of the magnetic resonance imaging findings could have resulted in a 29% reduction in the number of arthroscopies without missing any significant meniscal lesion


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 2 | Pages 217 - 223
1 Mar 1988
Mackinnon J Young S Baily R

Since 1974, we have made a prospective study in Bristol of the results of unicompartmental knee replacement using the St Georg sledge prosthesis. A total of 115 knees in 100 patients have been followed up for 2 to 12 years (mean, 4 years 9 months). Results have assessed both by the Bristol knee score and by survivorship studies on the total series of 138 knees. Results were excellent or good in 86% and fair or poor in 14%. The survivorship study (based on a definition of failure which included significant pain or a dissatisfied patient or the need for revision) showed a cumulative success rate of 76.4% at six years, with no further failures after that time. Seven knees have been revised, in most cases for deterioration of the contralateral compartment. The operation is recommended as a satisfactory and durable form of treatment for osteoarthritis affecting a single tibiofemoral compartment


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 4 | Pages 567 - 571
1 Aug 1985
Ogilvie-Harris D Bauer M Corey P

In a double-blind, randomised, prospective study of 139 patients undergoing arthroscopic meniscectomy, those receiving a prostaglandin inhibitor (naproxen sodium) had significantly less pain, less synovitis and less effusion. They had significantly more rapid return of movement and of quadriceps function; their return to work and to sport also was significantly faster. It is recommended that, provided there are no contraindications, a prostaglandin inhibitor should be used after arthroscopic procedures


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 6 | Pages 945 - 949
1 Nov 1993
Maffulli N Binfield P King J Good C

We made a prospective arthroscopic study of 106 skeletally mature male sportsmen with an average age of 28.35 years (16.8 to 44) who presented with an acute haemarthrosis of the knee due to sporting activities. We excluded those with patellar dislocations, radiographic bone injuries, extra-articular ligamentous lesions or a previous injury to the same joint. The anterior cruciate ligament (ACL) was intact in 35 patients, partially disrupted in 28 and completely ruptured in 43. In the patients with an ACL lesion, associated injuries included meniscal tears (17 patients), cartilaginous loose bodies (6), and minimal osteochondral fractures of the patella (2), the tibial plateau (3) or the femoral condyle (9). We found no age-related trend in the pattern of ACL injuries. Isolated injuries included one small osteochondral fracture of the patella, and one partial and one total disruption of the posterior cruciate ligament. Three patients had cartilaginous loose bodies, and no injury was detected in five. Acute traumatic haemarthrosis indicates a serious ligament injury until proved otherwise, and arthroscopy is needed to complement careful history and clinical examination. All cases with a tense effusion developing within 12 hours of injury should have an aspiration. If haemarthrosis is confirmed, urgent admission and arthroscopy are indicated


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 3 | Pages 345 - 351
1 May 1992
Leung K So W Shen W Hui P

The Gamma nail was introduced for the treatment of peritrochanteric fractures with the theoretical advantage of a load-sharing femoral component which could be implanted by a closed procedure. We report a randomised prospective study of 186 fractures treated by either the Gamma nail or a dynamic hip screw. Gamma nails were implanted with significantly shorter screening times, smaller incisions, and less intraoperative bleeding. The Gamma nail group had a shorter convalescence and earlier full weight-bearing, but there was no significant difference in mortality within six months, postoperative mobility, or hip function at review. More intra-operative complications were recorded in the Gamma nail group, mainly due to the mismatching of the femoral component of the nail to the small femurs of Chinese people. Use of a smaller modified nail reduced these complications. We conclude that with careful surgical technique and the modified femoral component, the Gamma nail is an advance in the treatment of peritrochanteric fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 2 | Pages 185 - 188
1 Mar 1985
Archer I Dickson R

A study of 130 scoliotic children with curves measuring 10 degrees or more has been performed in order to elucidate the importance of stature, growth and development. Girls with adolescent idiopathic curves measuring 15 degrees or more were taller than girls with smaller idiopathic curves and taller than those whose scoliosis was secondary to leg-length inequality (pelvic tilt scoliosis). No differences were observed as regards growth velocity or development. The increased standing height may be genetic but the uncoiling effect of the normal kyphosis to give a flat lateral profile is a more likely cause. The familial trend in idiopathic scoliosis may therefore be explained by the genetically determined shape of the spine in the median (sagittal) plane.


Bone & Joint Research
Vol. 4, Issue 11 | Pages 176 - 180
1 Nov 2015
Mirghasemi SA Rashidinia S Sadeghi MS Talebizadeh M Rahimi N

Objectives

There are various pin-in-plaster methods for treating fractures of the distal radius. The purpose of this study is to introduce a modified technique of ‘pin in plaster’.

Methods

Fifty-four patients with fractures of the distal radius were followed for one year post-operatively. Patients were excluded if they had type B fractures according to AO classification, multiple injuries or pathological fractures, and were treated more than seven days after injury. Range of movement and functional results were evaluated at three and six months and one and two years post-operatively. Radiographic parameters including radial inclination, tilt, and height, were measured pre- and post-operatively.


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1336 - 1344
1 Oct 2018
Powell AJ Crua E Chong BC Gordon R McAuslan A Pitto RP Clatworthy MG

Aims

This study compares the PFC total knee arthroplasty (TKA) system in a prospective randomized control trial (RCT) of the mobile-bearing rotating-platform (RP) TKA against the fixed-bearing (FB) TKA. This is the largest RCT with the longest follow-up where cruciate-retaining PFC total knee arthroplasties are compared in a non-bilateral TKA study.

Patients and Methods

A total of 167 patients (190 knees with 23 bilateral cases), were recruited prospectively and randomly assigned, with 91 knees receiving the RP and 99 knees receiving FB. The mean age was 65.5 years (48 to 82), the mean body mass index (BMI) was 29.7 kg/m2 (20 to 52) and 73 patients were female. The Knee Society Score (KSS), Knee Society Functional Score (KSFS), Oxford Knee Score (OKS), Western Ontario and McMaster Universities Arthritis Index (WOMAC), and 12-Item Short-Form Health Survey Physical and Mental Component Scores (SF-12 PCS, SF-12 MCS) were gathered and recorded preoperatively, at five-years’ follow-up, and at ten years’ follow-up. Additionally, Knee Injury and Osteoarthritis Outcome Scores (KOOS) were collected at five- and ten-year follow-ups. The prevalence of radiolucent lines (RL) on radiographs and implant survival were recorded at five- and ten-year follow-ups.


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 2 | Pages 179 - 182
1 Mar 1987
Weatherley C Draycott V O'Brien J Benson D Gopalakrishnan K Evans J O'Brien J

A prospective study to investigate changes in the rib hump or rib deformity after correction of the lateral curvature in adolescent idiopathic scoliosis is reported. The operative treatment for 47 patients was by a Harrington distraction rod and posterior fusion. Before operation and at follow-up, measurements of the Cobb angle, of vertebral rotation, and of the rib deformity were taken. Despite operative correction of the lateral curve, there was a progression of the rib deformity in 64% of the cases after four years. Correction of the lateral curve may thus have no effect on vertebral rotation and cannot be guaranteed to effect a permanent reduction of the rib hump


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 194 - 199
1 Feb 2012
Hoffart H Langenstein E Vasak N

The aim of this prospective single-centre study was to assess the difference in clinical outcome between total knee replacement (TKR) using computerised navigation and that of conventional TKR. We hypothesised that navigation would give a better result at every stage within the first five years. A total of 195 patients (195 knees) with a mean age of 70.0 years (39 to 89) were allocated alternately into two treatment groups, which used either conventional instrumentation (group A, 97 knees) or a navigation system (group B, 98 knees). After five years, complete clinical scores were available for 121 patients (62%). A total of 18 patients were lost to follow-up. Compared with conventional surgery, navigated TKR resulted in a better mean Knee Society score (p = 0.008). The difference in mean Knee Society scores over time between the two groups was not constant (p = 0.006), which suggests that these groups differed in their response to surgery with time. No significant difference in the frequency of malalignment was seen between the two groups.

In summary, computerised navigation resulted in a better functional outcome at five years than conventional techniques. Given the similarity in mechanical alignment between the two groups, rotational alignment may prove to be a better method of identifying differences in clinical outcome after navigated surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 2 | Pages 306 - 306
1 Mar 2002
COLERIDGE S


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 2 | Pages 307 - 307
1 Mar 2002
ROACH R


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 2 | Pages 306 - 307
1 Mar 2002
ACKROYD CE NEWMAN JH


The Bone & Joint Journal
Vol. 96-B, Issue 5 | Pages 641 - 645
1 May 2014
Tsutsumimoto T Yui M Uehara M Ohta H Kosaku H Misawa H

Little information is available about the incidence and outcome of incidental dural tears associated with microendoscopic lumbar decompressive surgery. We prospectively examined the incidence of dural tears and their influence on the outcome six months post-operatively in 555 consecutive patients (mean age 47.4 years (13 to 89)) who underwent this form of surgery. The incidence of dural tears was 5.05% (28/555). The risk factors were the age of the patient and the procedure of bilateral decompression via a unilateral approach. The rate of recovery of the Japanese Orthopaedic Association score in patients with dural tears was significantly lower than that in those without a tear (77.7% vs 87.6%; p < 0.02), although there were no significant differences in the improvement of the Oswestry Disability Index between the two groups. Most dural tears were small, managed by taking adequate care of symptoms of low cerebrospinal fluid pressure, and did not require direct dural repair. Routine MRI scans were undertaken six months post-operatively; four patients with a dural tear had recurrent or residual disc herniation and two had further stenosis, possibly because the dural tear prevented adequate decompression and removal of the fragments of disc during surgery; as yet, none of these patients have undergone further surgery.

Cite this article: Bone Joint J 2014;96-B:641–5.


The Journal of Bone & Joint Surgery British Volume
Vol. 62-B, Issue 1 | Pages 7 - 11
1 Feb 1980
Noble J Erat K

Of 250 patients scheduled for meniscectomy 50 had symptoms which subsided and operation could be deferred; of the remaining 200 only 73 per cent were found to have a significant tear. It is shown that the risks of removing a normal meniscus far exceed those of leaving a tear in the posterior third. Statistical analysis of clinical features revealed no reliable diagnostic pattern.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 2 | Pages 176 - 179
1 Feb 2009
Daniel J Ziaee H Pradhan C McMinn DJW

We describe the findings at six years in an ongoing prospective clinicoradiological and metal ion study in a cohort of 26 consecutive male patients with unilateral Birmingham Hip Resurfacing arthroplasties with one of two femoral head sizes (50 mm and 54 mm). Their mean age was 52.9 years (29 to 67). We have previously shown an early increase in the 24-hour urinary excretion of metal ions, reaching a peak at six months (cobalt) and one year (chromium) after operation. Subsequently there is a decreasing trend in excretion of both cobalt and chromium. The levels of cobalt and chromium in whole blood also show a significant increase at one year, followed by a decreasing trend until the sixth year.


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 6 | Pages 932 - 937
1 Nov 1993
Parmar H Triffitt P Gregg P

We report a prospective trial of 66 patients with intraarticular fractures of the calcaneum. All fractures were assessed by CT. Patients with displaced fractures were randomised to receive either conservative (n = 31) or operative treatment (n = 25). Undisplaced fractures (n = 10) were treated conservatively. Operation involved open reduction of the posterior subtalar joint, and fixation with Kirschner wires. All 66 patients were reviewed at a minimum of one year (mean 23 months). After conservative treatment the undisplaced fractures had slightly better results than the displaced fractures. There was no significant difference in outcome between the operatively and the conservatively treated displaced fractures. We have also documented prospectively the natural history of the injury, which is of use in assessing prognosis for both clinical and medicolegal purposes.


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 2 | Pages 251 - 253
1 Mar 1987
Fairclough J Colhoun E Johnston D Williams L

Of 693 elderly patients admitted with suspected hip fractures, 43 had normal radiographs and were investigated by isotope bone scan. The 30 patients (70%) with normal scans were mobilised and none developed a fracture. All 13 of the patients with specific bone scan abnormalities were subsequently proved to have fractures, five of which became displaced. Clearly conventional radiography does not exclude fracture of the femoral neck in elderly patients; bone scanning is advisable in doubtful cases.


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 5 | Pages 730 - 732
1 Nov 1988
Fidler M

Two cases of burst fracture of the upper lumbar spine are reported. In both cases the narrowing of the spinal canal shown by CT scans was progressively relieved by natural remodelling. The need for operative decompression should be assessed clinically and not from CT scans only.