Advertisement for orthosearch.org.uk
Results 21 - 40 of 1327
Results per page:
The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1668 - 1674
1 Dec 2015
Bao H Liu Z Yan P Qiu Y Zhu F

A self-control ratio, the spine-pelvis index (SPI), was proposed for the assessment of patients with adolescent idiopathic scoliosis (AIS) in this study. The aim was to evaluate the disproportionate growth between the spine and pelvis in these patients using SPI. A total of 64 female patients with thoracic AIS were randomly enrolled between December 2010 and October 2012 (mean age 13 years, standard deviation (. sd. ) 2.17; 9 to 18) and a further 73 healthy female patients with a mean age of 12.4 years (mean age 12.4 years, . sd. 2.24; 9 to 18), were randomly selected from a normal control database at our centre. The radiographic parameters measured included length of spine (LOS), height of spine (HOS), length of thoracic vertebrae (LOT), height of thoracic vertebrae (HOT), width of pelvis (WOP), height of pelvis (HOP) and width of thorax (WOT). SPI was defined as the ratio LOS/HOP. The SPI and LOT/HOP in patients with AIS showed a significant increase when compared with normal girls (p < 0.001 and p < 0.001 respectively), implying an abnormal pattern of growth of the spine relative to the pelvis in patients with AIS. . No significant difference in SPI was found in different age groups in the control group, making the SPI an age-independent parameter with a mean value of 2.219 (2.164 to 2.239). We also found that the SPI was not related to maturity in the control group. . This study, for the first time, used a self-control ratio to confirm the disproportionate patterns of growth of the spine and pelvis in patients with thoracic AIS, highlighting that the SPI is not affected by age or maturity. Cite this article: Bone Joint J 2015;97-B:1668–74


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1508 - 1512
1 Nov 2006
Wimsey S Pickard R Shaw G

Magnification of anteroposterior radiographs of the pelvis is variable. To improve the accuracy of templating, reliable and radiographer-friendly methods of scaling are necessary. We assessed two methods of scaling digital radiographs of the pelvis: placing a coin of known diameter in the plane of interest between the patient’s thighs, and using a caliper to measure the bony width of the pelvis. A total of 39 patients who had recently undergone hemiarthroplasty of the hip or total hip replacement were enrolled in the study. The accuracy of the methods was assessed by comparing the actual diameter of the head of the prosthesis with the measured on-screen value. The coin method was within a mean of 1.12% (0% to 2.38%) of the actual measurement, the caliper group within 6.99% (0% to 16.67%). The coin method was significantly more accurate (p < 0.001). It was also reliable and radiographer friendly. We recommend it as the method of choice for scaling radiographs of the pelvis before hip surgery


Bone & Joint 360
Vol. 11, Issue 5 | Pages 12 - 15
1 Oct 2022


Bone & Joint 360
Vol. 11, Issue 4 | Pages 11 - 14
1 Aug 2022


Bone & Joint 360
Vol. 11, Issue 3 | Pages 14 - 17
1 Jun 2022


Bone & Joint 360
Vol. 11, Issue 1 | Pages 17 - 20
1 Feb 2022


Bone & Joint 360
Vol. 11, Issue 2 | Pages 15 - 18
1 Apr 2022


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 261 - 266
1 Feb 2017
Laitinen MK Parry MC Albergo JI Grimer RJ Jeys LM

Aims. Due to the complex anatomy of the pelvis, limb-sparing resections of pelvic tumours achieving adequate surgical margins, can often be difficult. The advent of computer navigation has improved the precision of resection of these lesions, though there is little evidence comparing resection with or without the assistance of navigation. Our aim was to evaluate the efficacy of navigation-assisted surgery for the resection of pelvic bone tumours involving the posterior ilium and sacrum. . Patients and Methods. Using our prospectively updated institutional database, we conducted a retrospective case control study of 21 patients who underwent resection of the posterior ilium and sacrum, for the treatment of a primary sarcoma of bone, between 1987 and 2015. The resection was performed with the assistance of navigation in nine patients and without navigation in 12. We assessed the accuracy of navigation-assisted surgery, as defined by the surgical margin and how this affects the rate of local recurrence, the disease-free survival and the effects on peri-and post-operative morbidity. . Results. The mean age of the patients was 36.4 years (15 to 66). The mean size of the tumour was 10.9 cm. In the navigation-assisted group, the margin was wide in two patients (16.7%), marginal in six (66.7%) and wide-contaminated in one (11.1%) with no intralesional margin. In the non-navigated-assisted group; the margin was wide in two patients (16.7%), marginal in five (41.7%), intralesional in three (25.0%) and wide-contaminated in two (16.7%). Local recurrence occurred in two patients in the navigation-assisted group (22.2%) and six in the non-navigation-assisted group (50.0%). The disease-free survival was significantly better when operated with navigation-assistance (p = 0.048). The blood loss and operating time were less in the navigated-assisted group, as was the risk of a foot drop post-operatively. Conclusion . The introduction of navigation-assisted surgery for the resection of tumours of the posterior ilium and sacrum has increased the safety for the patients and allows for a better oncological outcome. . Cite this article: Bone Joint J 2017;99-B:261–6


Bone & Joint 360
Vol. 4, Issue 1 | Pages 14 - 16
1 Feb 2015

The February 2015 Hip & Pelvis Roundup. 360 . looks at: Hip arthroplasty in Down syndrome; Bulk femoral autograft successful in acetabular reconstruction; Arthroplasty follow-up: is the internet the solution?; Total hip arthroplasty following acetabular fracture; Salvage arthroplasty following failed hip internal fixation; Bone banking sensible financially and clinically; Allogenic blood transfusion in arthroplasty


Bone & Joint 360
Vol. 4, Issue 6 | Pages 8 - 10
1 Dec 2015

The December 2015 Hip & Pelvis Roundup. 360 . looks at: Vitamin E infusion helpful in polyethylene; Hip replacement in fracture and arthritis; Non-surgical treatment for arthritis; Cost and approach in hip surgery; Who does well in FAI surgery?; AAOS Thromboembolism guidelines; Thromboprophylaxis and periprosthetic joint infection; Fluid collections not limited to metal-on-metal THR


Bone & Joint Research
Vol. 6, Issue 10 | Pages 577 - 583
1 Oct 2017
Sallent A Vicente M Reverté MM Lopez A Rodríguez-Baeza A Pérez-Domínguez M Velez R

Objectives. To assess the accuracy of patient-specific instruments (PSIs) versus standard manual technique and the precision of computer-assisted planning and PSI-guided osteotomies in pelvic tumour resection. Methods. CT scans were obtained from five female cadaveric pelvises. Five osteotomies were designed using Mimics software: sacroiliac, biplanar supra-acetabular, two parallel iliopubic and ischial. For cases of the left hemipelvis, PSIs were designed to guide standard oscillating saw osteotomies and later manufactured using 3D printing. Osteotomies were performed using the standard manual technique in cases of the right hemipelvis. Post-resection CT scans were quantitatively analysed. Student’s t-test and Mann–Whitney U test were used. Results. Compared with the manual technique, PSI-guided osteotomies improved accuracy by a mean 9.6 mm (p < 0.008) in the sacroiliac osteotomies, 6.2 mm (p < 0.008) and 5.8 mm (p < 0.032) in the biplanar supra-acetabular, 3 mm (p < 0.016) in the ischial and 2.2 mm (p < 0.032) and 2.6 mm (p < 0.008) in the parallel iliopubic osteotomies, with a mean linear deviation of 4.9 mm (p < 0.001) for all osteotomies. Of the manual osteotomies, 53% (n = 16) had a linear deviation > 5 mm and 27% (n = 8) were > 10 mm. In the PSI cases, deviations were 10% (n = 3) and 0 % (n = 0), respectively. For angular deviation from pre-operative plans, we observed a mean improvement of 7.06° (p < 0.001) in pitch and 2.94° (p < 0.001) in roll, comparing PSI and the standard manual technique. Conclusion. In an experimental study, computer-assisted planning and PSIs improved accuracy in pelvic tumour resections, bringing osteotomy results closer to the parameters set in pre-operative planning, as compared with standard manual techniques. Cite this article: A. Sallent, M. Vicente, M. M. Reverté, A. Lopez, A. Rodríguez-Baeza, M. Pérez-Domínguez, R. Velez. How 3D patient-specific instruments improve accuracy of pelvic bone tumour resection in a cadaveric study. Bone Joint Res 2017;6:577–583. DOI: 10.1302/2046-3758.610.BJR-2017-0094.R1


Bone & Joint 360
Vol. 3, Issue 5 | Pages 10 - 12
1 Oct 2014

The October 2014 Hip & Pelvis Roundup. 360 . looks at: functional acetabular orientation; predicting re-admission following THR; metal ions and resurfacing; lipped liners increase stability; all anaesthetics equal in hip fracture surgery; revision hip surgery in very young patients; and uncemented hips


Bone & Joint 360
Vol. 4, Issue 5 | Pages 10 - 12
1 Oct 2015

The October 2015 Hip & Pelvis Roundup. 360 . looks at: Smoking and complications in arthroplasty; Smoking cessation beneficial in arthroplasty; Intermediate care and arthroplasty; Do we still need cell salvage?; Femoroacetabular impingement in the Japanese population; Trunnionosis or taperosis and geometry; Decontamination for staphylococcus aureus works!; Policeman or opportunity? Quality improvement with registries; Death rates higher in readmission to other hospitals


Bone & Joint 360
Vol. 10, Issue 6 | Pages 15 - 18
1 Dec 2021


Bone & Joint 360
Vol. 3, Issue 2 | Pages 8 - 9
1 Apr 2014

The April 2014 Hip & Pelvis Roundup. 360 . looks at: Recent arthroplasty and flight; whether that squeak could be a fracture; diagnosing early infected hip replacement; impaction grafting at a decade; whether squeaking is more common than previously thought; femoral offset associated with post THR outcomes; and periprosthetic fracture stabilisation


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 11 | Pages 1481 - 1488
1 Nov 2010
Guthrie HC Owens RW Bircher MD

High energy fractures of the pelvis are a challenging problem both in the immediate post-injury phase and later when definitive fixation is undertaken. No single management algorithm can be applied because of associated injuries and the wide variety of trauma systems that have evolved around the world. Initial management is aimed at saving life and this is most likely to be achieved with an approach that seeks to identify and treat life-threatening injuries in order of priority. Early mortality after a pelvic fracture is most commonly due to major haemorrhage or catastrophic brain injury. In this article we review the role of pelvic binders, angiographic embolisation, pelvic packing, early internal fixation and blood transfusion with regard to controlling haemorrhage. Definitive fixation seeks to prevent deformity and reduce complications. We believe this should be undertaken by specialist surgeons in a hospital resourced, equipped and staffed to manage the whole spectrum of major trauma. We describe the most common modes of internal fixation by injury type and review the factors that influence delayed mortality, adverse functional outcome, sexual dysfunction and venous thromboembolism


The Journal of Bone & Joint Surgery British Volume
Vol. 42-B, Issue 3 | Pages 432 - 443
1 Aug 1960
Dommisse GF

1. The strength of the pelvic arch depends on the integrity of the anterior interpubic ligament, whose strength has been demonstrated by dissections. Once that ligament is divided the sacro-iliac ligaments offer little resistance to opening out of the pelvis. 2. The structure of the pelvis and hips is compared to an arcade formed by a central and two lateral arches. The weight of the trunk is transmitted to the lower limbs through this arcade. 3. Fractures of the pelvis are classified according to the mechanism of production. The case for anatomical reposition and internal fixation is stated, and case histories are given to illustrate the disabilities due to persistent deformity. 4. Reduction can be achieved as late as two or three weeks after injury. However, if early operation for visceral injury is necessary, there is a strong case for combining this with open reduction and fixation. In some cases the patient's general condition may preclude such procedures, but more usually the additional manipulations cause little additional operative shock and are fully justified by the subsequent increased comfort of the patient and the greater ease of nursing


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1472 - 1477
1 Nov 2014
Vioreanu MH Parry MC Haddad FS Duncan CP

The Unified Classification System (UCS) emphasises the key principles in the assessment and management of peri-prosthetic fractures complicating partial or total joint replacement. We tested the inter- and intra-observer agreement for the UCS as applied to the pelvis and femur using 20 examples of peri-prosthetic fracture in 17 patients. Each subtype of the UCS was represented by at least one case. Specialist orthopaedic surgeons (experts) and orthopaedic residents (pre-experts) assessed reliability on two separate occasions. For the pelvis, the UCS showed inter-observer agreement of 0.837 (95% confidence intervals (CI) 0.798 to 0.876) for the experts and 0.728 (95% CI 0.689 to 0.767) for the pre-experts. The intra-observer agreement for the experts was 0.861 (95% CI 0.760 to 0.963) and 0.803 (95% 0.688 to 0.918) for the pre-experts. For the femur, the UCS showed an inter-observer kappa value of 0.805 (95% CI 0.765 to 0.845) for the experts and a value of 0.732 (95% CI 0.690 to 0.773) for the pre-experts. The intra-observer agreement was 0.920 (95% CI 0.867 to 0.973) for the experts, and 0.772 (95% CI 0.652 to 0.892) for the pre-experts. This corresponds to a substantial and ‘almost perfect’ inter- and intra-observer agreement for the UCS for peri-prosthetic fractures of the pelvis and femur. We hope that unifying the terminology of these injuries will assist in their assessment, treatment and outcome. Cite this article: Bone Joint J 2014;96-B:1472–7


Bone & Joint 360
Vol. 4, Issue 2 | Pages 10 - 12
1 Apr 2015

The April 2015 Hip & Pelvis Roundup. 360 . looks at: Goal-directed fluid therapy in hip fracture; Liberal blood transfusion no benefit in the longer term; Repeated measures: increased accuracy or compounded errors?; Peri-acetabular osteotomy safer than perhaps thought?; Obesity and peri-acetabular osteotomy: poor bedfellows; Stress fracture in peri-acetabular osteotomy; Infection and tantalum implants; Highly crosslinked polyethylene really does work


Bone & Joint 360
Vol. 10, Issue 4 | Pages 14 - 17
1 Aug 2021