Advertisement for orthosearch.org.uk
Results 21 - 40 of 47
Results per page:
Bone & Joint Research
Vol. 9, Issue 4 | Pages 192 - 199
1 Apr 2020
Pijls BG Sanders IMJG Kujiper EJ Nelissen RGHH

Aims

Induction heating is a noninvasive, nonantibiotic treatment modality that can potentially be used to cause thermal damage to the bacterial biofilm on the metal implant surface. The purpose of this study was to determine the effectiveness of induction heating on killing Staphylococcus epidermidis from biofilm and to determine the possible synergistic effect of induction heating and antibiotics.

Methods

S. epidermidis biofilms were grown on titanium alloy (Ti6Al4V) coupons for 24 hours (young biofilm) and seven days (mature biofilm). These coupons with biofilm were heated to temperatures of 50°C, 55°C, 60°C, 65°C, 70°C, 80°C, and 90°C for 3.5 minutes and subsequently exposed to vancomycin and rifampicin at clinically relevant concentrations.


Bone & Joint Research
Vol. 6, Issue 5 | Pages 296 - 306
1 May 2017
Samara E Moriarty TF Decosterd LA Richards RG Gautier E Wahl P

Objectives

Thermal stability is a key property in determining the suitability of an antibiotic agent for local application in the treatment of orthopaedic infections. Despite the fact that long-term therapy is a stated goal of novel local delivery carriers, data describing thermal stability over a long period are scarce, and studies that avoid interference from specific carrier materials are absent from the orthopaedic literature.

Methods

In this study, a total of 38 frequently used antibiotic agents were maintained at 37°C in saline solution, and degradation and antibacterial activity assessed over six weeks. The impact of an initial supplementary heat exposure mimicking exothermically curing bone cement was also tested as this material is commonly used as a local delivery vehicle. Antibiotic degradation was assessed by liquid chromatography coupled to mass spectrometry, or by immunoassays, as appropriate. Antibacterial activity over time was determined by the Kirby-Bauer disk diffusion assay.


The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1537 - 1544
1 Nov 2017
Wahl P Guidi M Benninger E Rönn K Gautier E Buclin T Magnin J Livio F

Aims

Calcium sulphate (CaSO4) is a resorbable material that can be used simultaneously as filler of a dead space and as a carrier for the local application of antibiotics. Our aim was to describe the systemic exposure and the wound fluid concentrations of vancomycin in patients treated with vancomycin-loaded CaSO4 as an adjunct to the routine therapy of bone and joint infections.

Patients and Methods

A total of 680 post-operative blood and 233 wound fluid samples were available for analysis from 94 implantations performed in 87 patients for various infective indications. Up to 6 g of vancomycin were used. Non-compartmental pharmacokinetic analysis was performed on the data from 37 patients treated for an infection of the hip.


Bone & Joint 360
Vol. 2, Issue 2 | Pages 1 - 1
1 Apr 2013
Ollivere BJ


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 159 - 162
1 Feb 2006
Hakkalamani S Rawal A Hennessy MS Parkinson RW


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1154 - 1159
1 Sep 2011
Parsons NR Hiskens R Price CL Achten J Costa ML

The poor reporting and use of statistical methods in orthopaedic papers has been widely discussed by both clinicians and statisticians. A detailed review of research published in general orthopaedic journals was undertaken to assess the quality of experimental design, statistical analysis and reporting. A representative sample of 100 papers was assessed for compliance to CONSORT and STROBE guidelines and the quality of the statistical reporting was assessed using a validated questionnaire. Overall compliance with CONSORT and STROBE guidelines in our study was 59% and 58% respectively, with very few papers fulfilling all criteria. In 37% of papers patient numbers were inadequately reported; 20% of papers introduced new statistical methods in the ‘results’ section not previously reported in the ‘methods’ section, and 23% of papers reported no measurement of error with the main outcome measure. Taken together, these issues indicate a general lack of statistical rigour and are consistent with similar reviews undertaken in a number of other scientific and clinical research disciplines. It is imperative that the orthopaedic research community strives to improve the quality of reporting; a failure to do so could seriously limit the development of future research.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 276 - 280
1 Feb 2012
Buijze GA Weening AA Poolman RW Bhandari M Ring D

Using inaccurate quotations can propagate misleading information, which might affect the management of patients. The aim of this study was to determine the predictors of quotation inaccuracy in the peer-reviewed orthopaedic literature related to the scaphoid. We randomly selected 100 papers from ten orthopaedic journals. All references were retrieved in full text when available or otherwise excluded. Two observers independently rated all quotations from the selected papers by comparing the claims made by the authors with the data and expressed opinions of the reference source. A statistical analysis determined which article-related factors were predictors of quotation inaccuracy. The mean total inaccuracy rate of the 3840 verified quotes was 7.6%. There was no correlation between the rate of inaccuracy and the impact factor of the journal. Multivariable analysis identified the journal and the type of study (clinical, biomechanical, methodological, case report or review) as important predictors of the total quotation inaccuracy rate.

We concluded that inaccurate quotations in the peer-reviewed orthopaedic literature related to the scaphoid were common and slightly more so for certain journals and certain study types. Authors, reviewers and editorial staff play an important role in reducing this inaccuracy.


Bone & Joint Research
Vol. 5, Issue 3 | Pages 95 - 100
1 Mar 2016
Pilge H Fröbel J Prodinger PM Mrotzek SJ Fischer JC Zilkens C Bittersohl B Krauspe R

Objectives

Venous thromboembolism (VTE) is a major potential complication following orthopaedic surgery. Subcutaneously administered enoxaparin has been used as the benchmark to reduce the incidence of VTE. However, concerns have been raised regarding the long-term administration of enoxaparin and its possible negative effects on bone healing and bone density with an increase of the risk of osteoporotic fractures. New oral anticoagulants such as rivaroxaban have recently been introduced, however, there is a lack of information regarding how these drugs affect bone metabolism and post-operative bone healing.

Methods

We measured the migration and proliferation capacity of mesenchymal stem cells (MSCs) under enoxaparin or rivaroxaban treatment for three consecutive weeks, and evaluated effects on MSC mRNA expression of markers for stress and osteogenic differentiation.


Bone & Joint 360
Vol. 4, Issue 6 | Pages 31 - 35
1 Dec 2015
Ahmed SS

The number of clinical negligence claims in the UK is constantly increasing. As a specialty, trauma and orthopaedic surgery has one of the highest numbers of negligence claims.1 This study analyses NHS Litigation Authority (NHSLA) claims in trauma and orthopaedics between 2004 and 2014.

A formal request was made to the NHSLA under the Freedom of Information Act in order to obtain all data related to claims against orthopaedic surgery. It was found that the number of claims, and percentage of successful claims, has been constantly increasing over this period, with compensation paid of over £349 million.* Errors in clinical management accounted for the highest number of closed claims (2933 claims), costing over £119 million.*

The level of compensation paid out has a significant financial impact on the NHS. Reforms need to be made in order to tackle the high cost of legal fees generated by these claims, which further drain the limited resources available to the NHS.


The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 81 - 87
1 Jan 2016
Miska M Findeisen S Tanner M Biglari B Studier-Fischer S Grützner PA Schmidmaier G Moghaddam A

Methods

Between 2005 and 2012, 50 patients (23 female, 27 male) with nonunion of the humeral shaft were included in this retrospective study. The mean age was 51.3 years (14 to 88). The patients had a mean of 1.5 prior operations (sd 1.2;1 to 8).

All patients were assessed according to a specific risk score in order to devise an optimal and individual therapy plan consistent with the Diamond Concept. In 32 cases (64%), a change in the osteosynthesis to an angular stable locking compression plate was performed. According to the individual risk an additional bone graft and/or bone morphogenetic protein-7 (BMP-7) were applied.

Results

A successful consolidation of the nonunion was observed in 37 cases (80.4%) with a median healing time of six months (IQR 6). Younger patients showed significantly better consolidation. Four patients were lost to follow-up. Revision was necessary in a total of eight (16%) cases. In the initial treatment, intramedullary nailing was most common.


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 875 - 879
1 Jul 2015
Fernandez MA Griffin XL Costa ML

Hip fracture is a common injury associated with high mortality, long-term disability and huge socio-economic burden. Yet there has been relatively little research into best treatment, and evidence that has been generated has often been criticised for its poor quality. Here, we discuss the advances made towards overcoming these criticisms and the future directions for hip fracture research: how co-ordinating existing national infrastructures and use of now established clinical research networks will likely go some way towards overcoming the practical and financial challenges of conducting large trials. We highlight the importance of large collaborative pragmatic trials to inform decision/policy makers and the progress made towards reaching a consensus on a core outcome set to facilitate data pooling for evidence synthesis and meta-analysis.

These advances and future directions are a priority in order to establish the high-quality evidence base required for this important group of patients.

Cite this article: Bone Joint J 2015;97-B:875–9.


Bone & Joint 360
Vol. 4, Issue 2 | Pages 17 - 20
1 Apr 2015

The April 2015 Wrist & Hand Roundup360 looks at: Non-operative hand fracture management; From the sublime to the ridiculous?; A novel approach to carpal tunnel decompression; Osteoporosis and functional scores in the distal radius; Ulnar variance and force distribution; Tourniquets in carpal tunnel under the spotlight; Scaphoid fractures reclassified; Osteoporosis and distal radial fracture fixation; PROMISing results in the upper limb


Bone & Joint 360
Vol. 2, Issue 6 | Pages 1 - 1
1 Dec 2013
Ollivere BJ


Bone & Joint 360
Vol. 3, Issue 3 | Pages 21 - 22
1 Jun 2014

The June 2014 Foot & Ankle Roundup360 looks at: peroneal tendon tears associated with calcaneal fractures; syndesmosis procedure for first ray deformities; thromboprophylaxis not necessary in elective Ilizarov surgery; ankle replacement gaining traction in academic centres; some evidence for PRP and; fusion nailing and osteotomy an effective treatment for symptomatic tibial malunion


Bone & Joint 360
Vol. 3, Issue 3 | Pages 37 - 39
1 Jun 2014

The June 2014 Research Roundup360 looks at:Intraoperative irrigation a balance of toxicities; Ibandronate effective in bone marrow oedema; Risk stratification in damage control surgery; Osteoblast like cells potentially safe; Better wear and antibacterial?; Assessing outcomes in hip fracture.


Bone & Joint 360
Vol. 3, Issue 4 | Pages 5 - 8
1 Aug 2014
Budd H Ollivere B Norrish A

While the demand for orthopaedic surgical expertise in the developing world is in critically short supply, short-term remedy from visiting doctors cannot solve this long-term healthcare problem. Capacity building by senior and training orthopaedic surgeons from established Western training programmes can offer a significant contribution to the orthopaedic patient in the developing world and the gains for those visiting are extremely valuable. We report on several visits by a UK orthopaedic team to a hospital in Kabul, Afghanistan and discuss the operative and non-operative case mix and the benefits in terms of local capacity building and the unique experience of those visiting.


Bone & Joint 360
Vol. 3, Issue 4 | Pages 35 - 38
1 Aug 2014
Hammerberg EM


Bone & Joint Research
Vol. 6, Issue 5 | Pages 323 - 330
1 May 2017
Pijls BG Sanders IMJG Kuijper EJ Nelissen RGHH

Objectives

Infection of implants is a major problem in elective and trauma surgery. Heating is an effective way to reduce the bacterial load in food preparation, and studies on hyperthermia treatment for cancer have shown that it is possible to heat metal objects with pulsed electromagnetic fields selectively (PEMF), also known as induction heating. We therefore set out to answer the following research question: is non-contact induction heating of metallic implants effective in reducing bacterial load in vitro?

Methods

Titanium alloy cylinders (Ti6Al4V) were exposed to PEMF from an induction heater with maximum 2000 watts at 27 kHz after being contaminated with five different types of micro-organisms: Staphylococcus epidermidis; Staphylococcus aureus; Pseudomonas aeruginosa; spore-forming Bacillus cereus; and yeast Candida albicans. The cylinders were exposed to incremental target temperatures (35°C, 45°C, 50°C, 55°C, 60°C, 65°C, 70°C) for up to 3.5 minutes.


Bone & Joint 360
Vol. 1, Issue 1 | Pages 32 - 32
1 Feb 2012
Barbieri CH


Bone & Joint 360
Vol. 1, Issue 5 | Pages 19 - 21
1 Oct 2012

The October 2012 Shoulder & Elbow Roundup360 looks at: fast-absorbing suture anchors for use in shoulder labral tears; double-row rotator cuff repair; degenerate massive rotator cuff tears addressed with partial repair; open and arthroscopic stabilisation of Bankart lesions; predicting the risk of revision humeral head replacement; arthroscopic treatment for frozen shoulder; and long-term follow-up of the Bristow-Latarjet procedure.