Advertisement for orthosearch.org.uk
Results 21 - 40 of 40
Results per page:
Bone & Joint Research
Vol. 7, Issue 1 | Pages 46 - 57
1 Jan 2018
Zhou J Zhou XG Wang JW Zhou H Dong J

Objective

In the present study, we aimed to assess whether gelatin/β-tricalcium phosphate (β-TCP) composite porous scaffolds could be used as a local controlled release system for vancomycin. We also investigated the efficiency of the scaffolds in eliminating infections and repairing osteomyelitis defects in rabbits.

Methods

The gelatin scaffolds containing differing amounts of of β-TCP (0%, 10%, 30% and 50%) were prepared for controlled release of vancomycin and were labelled G-TCP0, G-TCP1, G-TCP3 and G-TCP5, respectively. The Kirby-Bauer method was used to examine the release profile. Chronic osteomyelitis models of rabbits were established. After thorough debridement, the osteomyelitis defects were implanted with the scaffolds. Radiographs and histological examinations were carried out to investigate the efficiency of eliminating infections and repairing bone defects.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1154 - 1159
1 Sep 2012
Gibbs DMR Green TP Esler CN

Controversy remains regarding the optimal post-operative analgesic regimen following total knee replacement. A delicate balance is required between the provision of adequate pain relief and early mobilisation. By reviewing 29 randomised trials we sought to establish whether local infiltration of analgesia directly into the knee during surgery provides better pain relief and a more rapid rehabilitation. Although we were able to conclude that local infiltration can provide improved post-operative pain relief, and to suggest the most promising technique of administration, there is no evidence that it reduces hospital stay.


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1027 - 1035
1 Aug 2016
Pereira LC Kerr J Jolles BM

Aims

Using a systematic review, we investigated whether there is an increased risk of post-operative infection in patients who have received an intra-articular corticosteroid injection to the hip for osteoarthritis prior to total hip arthroplasty (THA).

Methods

Studies dealing with an intra-articular corticosteroid injection to the hip and infection following subsequent THA were identified from databases for the period between 1990 to 2013. Retrieved articles were independently assessed for their methodological quality.


Bone & Joint 360
Vol. 4, Issue 1 | Pages 32 - 33
1 Feb 2015

The February 2015 Research Roundup360 looks at: Markers of post-traumatic ankle arthritis; Mangoes, trees and Solomon Islanders; Corticosteroid injection and ulnar neuropathy; Moral decision-making: the secret skill?; Biomechanical studies under the spotlight; Anaesthetic risk and hip replacement


The Bone & Joint Journal
Vol. 97-B, Issue 4 | Pages 539 - 543
1 Apr 2015
Lawendy A Bihari A Sanders DW McGarr G Badhwar A Cepinskas G

Compartment syndrome, a devastating consequence of limb trauma, is characterised by severe tissue injury and microvascular perfusion deficits. We hypothesised that leucopenia might provide significant protection against microvascular dysfunction and preserve tissue viability. Using our clinically relevant rat model of compartment syndrome, microvascular perfusion and tissue injury were directly visualised by intravital video microscopy in leucopenic animals. We found that while the tissue perfusion was similar in both groups (38.8% (standard error of the mean (sem) 7.1), 36.4% (sem 5.7), 32.0% (sem 1.7), and 30.5% (sem 5.35) continuously-perfused capillaries at 45, 90, 120 and 180 minutes compartment syndrome, respectively versus 39.2% (sem 8.6), 43.5% (sem 8.5), 36.6% (sem 1.4) and 50.8% (sem 4.8) at 45, 90, 120 and 180 minutes compartment syndrome, respectively in leucopenia), compartment syndrome-associated muscle injury was significantly decreased in leucopenic animals (7.0% (sem 2.0), 7.0%, (sem 1.0), 9.0% (sem 1.0) and 5.0% (sem 2.0) at 45, 90, 120 and 180 minutes of compartment syndrome, respectively in leucopenia group versus 18.0% (sem 4.0), 23.0% (sem 4.0), 32.0% (sem 7.0), and 20.0% (sem 5.0) at 45, 90, 120 and 180 minutes of compartment syndrome in control, p = 0.0005). This study demonstrates that the inflammatory process should be considered central to the understanding of the pathogenesis of cellular injury in compartment syndrome.

Cite this article: Bone Joint J 2015;97-B:539–43


Bone & Joint 360
Vol. 3, Issue 2 | Pages 16 - 17
1 Apr 2014

The April 2014 Shoulder & Elbow Roundup360 looks at: arthroscopic capsular release successful after six months; MCIC in cuff surgery; analgesia following arthroscopic cuff repair; platelet-rich fibrin; and cuff tear and suprascapular nerve neuropathy?


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 9 | Pages 1173 - 1177
1 Sep 2006
Kean J Wigderowitz CA Coventry DM

We performed a double-blind, randomised controlled trial to assess the effectiveness of a continuous-infusion brachial plexus block with levobupivacaine compared with that of a standard single injection for the management of post-operative pain after surgery on the shoulder.

Eight patients were randomised to receive a pre-operative brachial plexus block using 30 ml of levobupivacaine 0.5% with adrenaline 1:200 000 followed by insertion of a 20-gauge polyamide catheter. This was connected to a disposable elastometric pump, set immediately after surgery to administer a continuous flow of levobupivacaine 0.25% at a rate of 5 ml per hour. The other eight patients were randomised to receive only the initial injection of 30 ml. The study was double-blinded with the aid of sham catheters and clamped pumps.

All patients were given regular paracetamol and were prescribed morphine through a patient-controlled analgesia pump. Motor and sensory block assessments, visual analogue scale pain scores and consumption of morphine were recorded after the operation and then at 6, 12 and 24 hours after administration of the block.

Satisfactory motor and sensory block was achieved in all patients. The mean visual analogue scale pain score at 12 hours and consumption of morphine at 24 hours after injection were significantly lower (p < 0.05) in the continuous-infusion group. This group also took longer to request their first additional analgesia and reported a significantly higher overall level of satisfaction.

Our study has shown that continuous interscalene infusion of levobupivacaine is an effective method of post-operative analgesia after major surgery of the shoulder.


Bone & Joint 360
Vol. 3, Issue 5 | Pages 25 - 28
1 Oct 2014

The October 2014 Trauma Roundup360 looks at: proximal humeral fractures in children; quadrilateral surface plates in transverse acetabular fractures; sleep deprivation and poor outcomes in trauma; bipolar hemiarthroplasty; skeletal traction; forefoot fractures; telemedicine in trauma; ketamine infusion for orthopaedic injuries; and improved functional outcomes seen with trauma networks.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 120 - 123
1 Nov 2013
Drexler M Dwyer T Chakravertty R Farno A Backstein D

Total knee replacement (TKR) is one of the most common operations in orthopaedic surgery worldwide. Despite its scientific reputation as mainly successful, only 81% to 89% of patients are satisfied with the final result. Our understanding of this discordance between patient and surgeon satisfaction is limited. In our experience, focus on five major factors can improve patient satisfaction rates: correct patient selection, setting of appropriate expectations, avoiding preventable complications, knowledge of the finer points of the operation, and the use of both pre- and post-operative pathways. Awareness of the existence, as well as the identification of predictors of patient–surgeon discordance should potentially help with enhancing patient outcomes.

Cite this article: Bone Joint J 2013;95-B, Supple A:120–3.


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1556 - 1561
1 Nov 2013
Irwin A Khan SK Jameson SS Tate RC Copeland C Reed MR

In our department we use an enhanced recovery protocol for joint replacement of the lower limb. This incorporates the use of intravenous tranexamic acid (IVTA; 15 mg/kg) at the induction of anaesthesia. Recently there was a national shortage of IVTA for 18 weeks; during this period all patients received an oral preparation of tranexamic acid (OTA; 25 mg/kg). This retrospective study compares the safety (surgical and medical complications) and efficacy (reduction of transfusion requirements) of OTA and IVTA. During the study period a total of 2698 patients received IVTA and 302 received OTA. After adjusting for a range of patient and surgical factors, the odds ratio (OR) of receiving a blood transfusion was significantly higher with IVTA than with OTA (OR 0.48 (95% confidence interval 0.26 to 0.89), p = 0.019), whereas the safety profile was similar, based on length of stay, rate of readmission, return to theatre, deep infection, stroke, gastrointestinal bleeding, myocardial infarction, pneumonia, deep-vein thrombosis and pulmonary embolism. The financial benefit of OTA is £2.04 for a 70 kg patient; this is amplified when the cost saving associated with significantly fewer blood transfusions is considered.

Although the number of patients in the study is modest, this work supports the use of OTA, and we recommend that a randomised trial be undertaken to compare the different methods of administering tranexamic acid.

Cite this article: Bone Joint J 2013;95-B:1556–61.


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1587 - 1594
1 Dec 2013
Ibrahim MS Twaij H Giebaly DE Nizam I Haddad FS

The outcome after total hip replacement has improved with the development of surgical techniques, better pain management and the introduction of enhanced recovery pathways. These pathways require a multidisciplinary team to manage pre-operative education, multimodal pain control and accelerated rehabilitation. The current economic climate and restricted budgets favour brief hospitalisation while minimising costs. This has put considerable pressure on hospitals to combine excellent results, early functional recovery and shorter admissions.

In this review we present an evidence-based summary of some common interventions and methods, including pre-operative patient education, pre-emptive analgesia, local infiltration analgesia, pre-operative nutrition, the use of pulsed electromagnetic fields, peri-operative rehabilitation, wound dressings, different surgical techniques, minimally invasive surgery and fast-track joint replacement units.

Cite this article: Bone Joint J 2013;95-B:1587–94.


Bone & Joint 360
Vol. 1, Issue 1 | Pages 23 - 24
1 Feb 2012


Bone & Joint 360
Vol. 1, Issue 5 | Pages 10 - 12
1 Oct 2012

The October 2012 Hip & Pelvis Roundup360 looks at: diagnosing the infected hip replacement; whether tranexamic acid has a low complication rate; the relationship between poor cementing technique and early failure of resurfacing; debridement and retention for the infected replacement; triple-tapered stems and bone mineral density; how early discharge can be bad for your sleep; an updated QFracture algorithm to predict the risk of an osteoporotic fracture; and local infiltration analgesia and total hip replacement.


Bone & Joint 360
Vol. 1, Issue 3 | Pages 12 - 14
1 Jun 2012

The June 2012 Knee Roundup360 looks at: ACI and mosaicplasty; ACI after microfracture; exercise therapy and the degenerate medial meniscal tear; intra-articular bupivacaine or ropivacaine at knee arthroscopy; lateral trochlear inclination and patellofemoral osteoarthritis; bone loss and ACL reconstruction; assessing stability using the contralateral knee; tranexamic acid and a useful review of knee replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 6 | Pages 856 - 862
1 Jun 2012
Piper SL Laron D Manzano G Pattnaik T Liu X Kim HT Feeley BT

Peri-tendinous injection of local anaesthetic, both alone and in combination with corticosteroids, is commonly performed in the treatment of tendinopathies. Previous studies have shown that local anaesthetics and corticosteroids are chondrotoxic, but their effect on tenocytes remains unknown. We compared the effects of lidocaine and ropivacaine, alone or combined with dexamethasone, on the viability of cultured bovine tenocytes. Tenocytes were exposed to ten different conditions: 1) normal saline; 2) 1% lidocaine; 3) 2% lidocaine; 4) 0.2% ropivacaine; 5) 0.5% ropivacaine; 6) dexamethasone (dex); 7) 1% lidocaine+dex; 8) 2% lidocaine+dex; 9) 0.2% ropivacaine+dex; and 10) 0.5% ropivacaine+dex, for 30 minutes. After a 24-hour recovery period, the viability of the tenocytes was quantified using the CellTiter-Glo viability assay and fluorescence-activated cell sorting (FACS) for live/dead cell counts. A 30-minute exposure to lidocaine alone was significantly toxic to the tenocytes in a dose-dependent manner, but a 30-minute exposure to ropivacaine or dexamethasone alone was not significantly toxic.

Dexamethasone potentiated ropivacaine tenocyte toxicity at higher doses of ropivacaine, but did not potentiate lidocaine tenocyte toxicity. As seen in other cell types, lidocaine has a dose-dependent toxicity to tenocytes but ropivacaine is not significantly toxic. Although dexamethasone alone is not toxic, its combination with 0.5% ropivacaine significantly increased its toxicity to tenocytes. These findings might be relevant to clinical practice and warrant further investigation.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 8 | Pages 1079 - 1084
1 Aug 2010
Muirhead-Allwood S Sandiford N Skinner JA Hua J Kabir C Walker PS

We present the 10- to 17-year results of 112 computer-assisted design computer-assisted manufacture femoral components. The total hip replacements were performed between 1992 and 1998 in 111 patients, comprising 53 men and 58 women. Their mean age was 46.2 years (24.6 to 62.2) with a mean follow-up of 13 years (10 to 17). The mean Harris Hip Score improved from 42.4 (7 to 99) to 90.3 (38 to 100), the mean Oxford Hip Score from 43.1 (12 to 59) to 18.2 (12 to 51) and the mean Western Ontario MacMasters University Osteoarthritis Index score from 57.0 (7 to 96) to 11.9 (0 to 85). There was one revision due to failure of the acetabular component but no failures of the femoral component. There were no revisions for aseptic loosening. The worst-case survival in this cohort of custom femoral components at 13.2 years follow-up was 98.2% (95% confidence interval 95 to 99). Overall survival of this series of total hip replacements was 97.3% (95% confidence interval 95 to 99).

These results are comparable with the best medium- to long-term results for femoral components used in primary total hip replacement with any means of fixation.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 738 - 744
1 Jun 2008
Pang H Lo N Yang K Chong H Yeo S

We have performed a prospective double-blind, randomised controlled trial over two years to evaluate the efficacy and safety of an intra-operative peri-articular injection of triamcinolone acetonide in patients undergoing medial unicondylar knee replacement. We randomised 90 patients into two equal groups. The study group received an injection of triamcinolone acetonide, bupivacaine, and epinephrine into the peri-articular tissues at the end of the operation. The control group received the same injection mixture but without the addition of triamcinolone. The peri-operative analgesic regimen was standardised.

The study group reported a significant reduction in pain (p = 0.014 at 12 hours, p = 0.031 at 18 hours and p = 0.031 at 24 hours) and had a better range of movement (p = 0.023 at three months). There was no significant difference in the rate of infection and no incidence of tendon rupture in either group.

The addition of corticosteroid to the peri-articular injection after unicondylar knee replacement had both immediate and short-term benefits in terms of relief from pain, and rehabilitation with no increased risk of infection.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 823 - 827
1 Jun 2006
White TO Clutton RE Salter D Swann D Christie J Robinson CM

The stress response to trauma is the summation of the physiological response to the injury (the ‘first hit’) and by the response to any on-going physiological disturbance or subsequent trauma surgery (the ‘second hit’).

Our animal model was developed in order to allow the study of each of these components of the stress response to major trauma. High-energy, comminuted fracture of the long bones and severe soft-tissue injuries in this model resulted in a significant tropotropic (depressor) cardiovascular response, transcardiac embolism of medullary contents and activation of the coagulation system. Subsequent stabilisation of the fractures using intramedullary nails did not significantly exacerbate any of these responses.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 814 - 820
1 Jun 2008
Chu CR Izzo NJ Coyle CH Papas NE Logar A

We have studied the effects of bupivacaine on human and bovine articular chondrocytes in vitro. Time-lapse confocal microscopy of human articular chondrocytes showed > 95% cellular death after exposure to 0.5% bupivacaine for 30 minutes. Human and bovine chondrocytes exposed to 0.25% bupivacaine had a time-dependent reduction in viability, with longer exposure times resulting in higher cytotoxicity. Cellular death continued even after removal of 0.25% bupivacaine. After exposure to 0.25% bupivacaine for 15 minutes, flow cytometry showed bovine chondrocyte viability to be 41% of saline control after seven days. After exposure to 0.125% bupivacaine for up to 60 minutes, the viability of both bovine and human chondrocytes was similar to that of control groups.

These data show that prolonged exposure 0.5% and 0.25% bupivacaine solutions are potentially chondrotoxic.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 4 | Pages 477 - 483
1 Apr 2006
Iwasa J Ochi M Uchio Y Adachi N Kawasaki K

We have investigated the changes in anterior laxity of the knee in response to direct electrical stimulation of eight normal and 45 reconstructed anterior cruciate ligaments (ACLs). In the latter, the mean time from reconstruction was 26.7 months (24 to 32). The ACL was stimulated electrically using a bipolar electrode probe during arthroscopy. Anterior laxity was examined with the knee flexed at 20° under a force of 134 N applied anteriorly to the tibia using the KT-2000 knee arthrometer before, during and after electrical stimulation.

Anterior tibial translation in eight normal and 17 ACL-reconstructed knees was significantly decreased during stimulation, compared with that before stimulation. In 28 knees with reconstruction of the ACL, in 22 of which the grafts were found to have detectable somatosensory evoked potentials during stimulation, anterior tibial translation was not decreased. These findings suggest that the ACL-hamstring reflex arc in normal knees may contribute to the functional stability and that this may not be fully restored after some reconstructions of the ACL.