Advertisement for orthosearch.org.uk
Results 21 - 31 of 31
Results per page:
The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 603 - 609
1 May 2018
Schnetzke M Rick S Raiss P Walch G Loew M

Aims

The aim of this study was to evaluate the clinical and radiological outcome of using an anatomical short-stem shoulder prosthesis to treat primary osteoarthritis of the glenohumeral joint.

Patients and Methods

A total of 66 patients (67 shoulders) with a mean age of 76 years (63 to 92) were available for clinical and radiological follow-up at two different timepoints (T1, mean 2.6 years, sd 0.5; T2, mean 5.3 years, sd 0.7). Postoperative radiographs were analyzed for stem angle, cortical contact, and filling ratio of the stem. Follow-up radiographs were analyzed for timing and location of bone adaptation (cortical bone narrowing, osteopenia, spot welds, and condensation lines). The bone adaptation was classified as low (between zero and three features of bone remodelling around the humeral stem) or high (four or more features).


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 610 - 614
1 May 2019
Aibinder WR Bartels DW Sperling JW Sanchez-Sotelo J

Aims

Shoulder arthroplasty using short humeral components is becoming increasingly popular. Some such components have been associated with relatively high rates of adverse radiological findings. The aim of this retrospective review was to evaluate the radiological humeral bone changes and mechanical failure rates with implantation of a short cementless humeral component in anatomical (TSA) and reverse shoulder arthroplasty (RSA).

Patients and Methods

A total of 100 shoulder arthroplasties (35 TSA and 65 RSA) were evaluated at a mean of 3.8 years (3 to 8.3). The mean age at the time of surgery was 68 years (31 to 90). The mean body mass index was 32.7 kg/m2 (17.3 to 66.4).


The Bone & Joint Journal
Vol. 101-B, Issue 6 | Pages 627 - 634
1 Jun 2019
King JJ Dalton SS Gulotta LV Wright TW Schoch BS

Aims

Acromial fractures following reverse shoulder arthroplasty (RSA) have a wide range of incidences in reported case series. This study evaluates their incidence following RSA by systematically reviewing the current literature.

Materials and Methods

A systematic review using the search terms “reverse shoulder”, “reverse total shoulder”, or “inverted shoulder” was performed using PubMed, Web of Science, and Cochrane databases between 1 January 2010 and 31 March 2018. Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were used. Studies were included if they reported on RSA outcomes and the incidence rate of acromial and/or scapular spine fractures. The rate of these fractures was evaluated for primary RSA, revision RSA, RSA indications, and RSA implant design.


Bone & Joint 360
Vol. 6, Issue 4 | Pages 2 - 7
1 Aug 2017
Titchener AG Tambe AA Clark DI


Bone & Joint 360
Vol. 5, Issue 4 | Pages 29 - 31
1 Aug 2016


The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1204 - 1208
1 Sep 2013
Kerens B Boonen B Schotanus MGM Lacroix H Emans PJ Kort NP

Although it has been suggested that the outcome after revision of a unicondylar knee replacement (UKR) to total knee replacement (TKR) is better when the mechanism of failure is understood, a comparative study on this subject has not been undertaken.

A total of 30 patients (30 knees) who underwent revision of their unsatisfactory UKR to TKR were included in the study: 15 patients with unexplained pain comprised group A and 15 patients with a defined cause for pain formed group B. The Oxford knee score (OKS), visual analogue scale for pain (VAS) and patient satisfaction were assessed before revision and at one year after revision, and compared between the groups.

The mean OKS improved from 19 (10 to 30) to 25 (11 to 41) in group A and from 23 (11 to 45) to 38 (20 to 48) in group B. The mean VAS improved from 7.7 (5 to 10) to 5.4 (1 to 8) in group A and from 7.4 (2 to 9) to 1.7 (0 to 8) in group B. There was a statistically significant difference between the mean improvements in each group for both OKS (p = 0.022) and VAS (p = 0.002). Subgroup analysis in group A, performed in order to define a patient factor that predicts outcome of revision surgery in patients with unexplained pain, showed no pre-operative differences between both subgroups.

These results may be used to inform patients about what to expect from revision surgery, highlighting that revision of UKR to TKR for unexplained pain generally results in a less favourable outcome than revision for a known cause of pain.

Cite this article: Bone Joint J 2013;95-B:1204–8.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 587 - 592
1 May 2011
Kim Y Kim J Park J Joo J

We reviewed the results of 84 total hip replacements performed with a short metaphyseal-fitting anatomical cementless femoral component in 84 unselected consecutive patients with a mean age of 78.9 years (70 to 88). The mean follow-up was 4.6 years (4 to 5). The mean pre-operative Harris hip score was 26 points (0 to 56), which improved to 89 (61 to 100) at the final follow-up. No patient had thigh pain. The mean pre-operative Western Ontario and McMaster Universities osteoarthritis index score was 61 points (48 to 75), which improved to 21 (6 to 46). The mean University of California, Los Angeles activity score was 5.5 points (3 to 7) at the final follow-up. Osseointegration was seen in all femoral and acetabular components. All hips had grade 1 stress shielding of the proximal femur. No acetabular or femoral osteolysis was identified.

These results demonstrate that a short metaphyseal-fitting femoral component achieves optimal fixation without diaphyseal anchorage in elderly patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 9 | Pages 1222 - 1224
1 Sep 2005
Sheng P Jämsen E Lehto MUK Konttinen YT Pajamäki J Halonen P

We report a consecutive series of 16 revision total knee arthroplasties using the Total Condylar III system in 14 patients with inflammatory arthritis which were performed between 1994 and 2000. There were 11 women and three men with a mean age of 59 years (36 to 78). The patients were followed up for 74 months (44 to 122).

The mean pre-operative Knee Society score of 37 points (0 to 77) improved to 88 (61 to 100) at follow-up (t-test, p < 0.001) indicating very good overall results. The mean range of flexion improved from 62° (0° to 120°) to 98° (0° to 145°) (t-test, p < 0.05) allowing the patients to stand from a sitting position. The mean Knee Society pain score improved from 22 (10 to 45) to 44 (20 to 50) (t-test, p < 0.05). No knee had definite loosening, although five showed asymptomatic radiolucent lines. Complications were seen in three cases, comprising patellar pain, patellar fracture and infection.

These results suggest that the Total Condylar III system can be used successfully in revision total knee arthroplasty in inflammatory arthritis.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 1110 - 1115
1 Aug 2006
Ong KL Kurtz SM Manley MT Rushton N Mohammed NA Field RE

The effects of the method of fixation and interface conditions on the biomechanics of the femoral component of the Birmingham hip resurfacing arthroplasty were examined using a highly detailed three-dimensional computer model of the hip. Stresses and strains in the proximal femur were compared for the natural femur and for the femur resurfaced with the Birmingham hip resurfacing. A comparison of cemented versus uncemented fixation showed no advantage of either with regard to bone loading. When the Birmingham hip resurfacing femoral component was fixed to bone, proximal femoral stresses and strains were non-physiological. Bone resorption was predicted in the inferomedial and superolateral bone within the Birmingham hip resurfacing shell. Resorption was limited to the superolateral region when the stem was not fixed. The increased bone strain observed adjacent to the distal stem should stimulate an increase in bone density at that location. The remodelling of bone seen during revision of failed Birmingham hip resurfacing implants appears to be consistent with the predictions of our finite element analysis.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 9 | Pages 1158 - 1163
1 Sep 2006
Tai CC Cross MJ

We carried out a prospective study of 118 hydroxyapatite-coated, cementless total knee replacements in patients who were ≤ 55 years of age and who had primary (92; 78%) or post-traumatic (26; 22%) osteoarthritis. The mean period of follow-up was 7.9 years (5 to 12.5). The Knee Society clinical scores improved from a pre-operative mean of 98 (0 to 137) to a mean of 185 (135 to 200) at five years, and 173 (137 to 200) at ten years. There were two revisions of the tibial component because of aseptic loosening, and one case of polyethylene wear requiring further surgery. There was no osteolysis or progressive radiological loosening of any other component. At 12 years, the overall rate of implant survival was 97.5% (excluding exchange of spacer) and 92.1% (including exchange of spacer).

Cementless total knee replacement can achieve excellent long-term results in young, active patients with osteoarthritis. In contrast to total hip replacement, polyethylene wear, osteolysis and loosening of the prosthesis were not major problems for these patients, although it is possible that this observation could change with longer periods of follow-up.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 5 | Pages 562 - 575
1 May 2006
Boileau P Sinnerton RJ Chuinard C Walch G