Advertisement for orthosearch.org.uk
Results 21 - 40 of 209
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 1 | Pages 78 - 81
1 Jan 1994
Vanderwilde R Morrey B Melberg M Vinh T

The management of radial head fractures complicated by ligamentous disruption remains a matter of controversy. The use of a silicone radial head implant to provide temporary stability is thought to help to protect the ligaments during healing. The reported complications of long-term implantation of a silicone replacement include fracture, dislocation, synovitis, lymphadenitis and subchondral resorption. We now report one case in which an inflammatory process resulted in generalised cartilage degeneration. This has not previously been noted


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 7 | Pages 1040 - 1044
1 Sep 2003
Ikeda M Yamashina Y Kamimoto M Oka Y

Between 1996 and 2000, we treated ten patients with severely comminuted fractures of the radial head using low-profile mini-plates. Their mean age was 42 years (24 to 71). Three fractures were Mason type III and seven were Mason-Johnston type IV. At a mean follow-up of 28.5 months (15 to 44), all fractures had united. The plates were removed in nine patients. No patient had difficulty with daily activities or symptoms of instability of the elbow. The mean range of flexion of the elbow was from 7° to 135°, with 74° of supination and 85° of pronation. According to the Broberg and Morrey functional elbow index, the mean score was 90.7 points (73 to 100), and the outcome was excellent in three patients, good in six and fair in one. These results compare favourably with those reported previously. The technique is applicable to severely comminuted fractures of the radial head which otherwise would require excision


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 1 | Pages 64 - 65
1 Jan 1983
Good C Wicks M

We describe two boys with bilateral deformity of the upper end of the radius. The condition appears to predispose to non-traumatic posterior dislocation of the radial head and is associated with posterior bowing of the upper end of the ulna. This problem has not been previously described


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1545 - 1550
1 Nov 2007
Koslowsky TC Mader K Dargel J Koebke J Hellmich M Pennig D

We have evaluated four different fixation techniques for the reconstruction of a standard Mason type-III fracture of the radial head in a sawbone model. The outcome measurements were the quality of the reduction, and stability. A total of 96 fractures was created. Six surgeons were involved in the study and each reconstructed 16 fractures with 1.6 mm fine-threaded wires (Fragment Fixation System (FFS)), T-miniplates, 2 mm miniscrews and 2 mm Kirschner (K-) wires; four fractures being allocated to each method using a standard reconstruction procedure. The quality of the reduction was measured after definitive fixation. Biomechanical testing was performed using a transverse plane shear load in two directions to the implants (parallel and perpendicular) with respect to ultimate failure load and displacement at 50 N. A significantly better quality of reduction was achieved using the FFS wires (Tukey’s post hoc tests, p < 0.001) than with the other devices with a mean step in the articular surface and the radial neck of 1.04 mm (. sd. 0.96) for the FFS, 4.25 mm (. sd. 1.29) for the miniplates, 2.21 mm (. sd. 1.06) for the miniscrews and 2.54 mm (. sd. 0.98) for the K-wires. The quality of reduction was similar for K-wires and miniscrews, but poor for miniplates. The ultimate failure load was similar for the FFS wires (parallel, 196.8 N (. sd. 46.8), perpendicular, 212.5 N (. sd. 25.6)), miniscrews (parallel, 211.8 N (. sd. 47.9), perpendicular, 208.0 N (. sd. 65.9)) and K-wires (parallel, 200.4 N (. sd. 54.5), perpendicular, 165.2 N (. sd. 37.9)), but significantly worse (Tukey’s post hoc tests, p < 0.001) for the miniplates (parallel, 101.6 N (. sd. 43.1), perpendicular, 122.7 N (. sd. 40.7)). There was a significant difference in the displacement at 50 N for the miniplate (parallel, 4.8 mm (. sd. 2.8), perpendicular, 4.8 mm (. sd. 1.7)) vs FFS (parallel, 2.1 mm (. sd. 0.8), perpendicular, 1.9 mm (. sd. 0.7)), miniscrews (parallel, 1.8 mm (. sd. 0.5), perpendicular, 2.3 mm (. sd. 0.8)) and K-wires (parallel, 2.2 mm (. sd. 1.8), perpendicular, 2.4 mm (. sd. 0.7; Tukey’s post hoc tests, p < 0.001)). The fixation of a standard Mason type-III fracture in a sawbone model using the FFS system provides a better quality of reduction than that when using conventional techniques. There was a significantly better stability using FFS implants, miniscrews and K-wires than when using miniplates


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1618 - 1619
1 Dec 2020
Klug A Nagy A Gramlich Y Hoffmann R


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 3 | Pages 378 - 381
1 May 1986
Hudson D De Beer J

Isolated traumatic dislocation of the radial head in children is not as rare as sometimes supposed. Attention to detail in radiographic interpretation is the key to diagnosis. Early closed reduction and immobilisation in an above-elbow plaster in 90 degrees of flexion and full supination for three to six weeks is recommended. Seven cases are presented, two of which were treated operatively and had unsatisfactory results. The applied anatomy, management and complications are discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 33-B, Issue 1 | Pages 65 - 73
1 Feb 1951
Penrose JH

1. The posterior Monteggia fracture usually conforms to a typical pattern. 2. Its incidence is greatest among middle-aged women. 3. The mechanism of the injury is probably similar to that of the dislocated elbow. Excessive rotation of the forearm plays no part in its production. 4. Internal fixation of the ulna combined with excision of the whole radial head, or of its detached segment, is suggested as the treatment of choice. 5. The functional results after operation are excellent, but some slight permanent restriction of movement is to be expected


The Journal of Bone & Joint Surgery British Volume
Vol. 39-B, Issue 2 | Pages 278 - 287
1 May 1957
McDougall A White J

1. Dislocation or sublaxation of the inferior radio-ulnar joint in association with fractures of the head of radius is discussed. 2. The incidence of the complication is greater than is generally supposed, and figures are given to support this finding. 3. The subluxation is not always associated with symptoms, and the degree of displacement may not be sufficient to be recognised clinically. 4. The anatomy and mechanism of the displacement have been investigated experimentally, and the results of the experiments are described


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 4 | Pages 577 - 581
1 Jul 1993
Oner F Diepstraten A

Seven children with chronic post-traumatic dislocation of the radial head were treated by open reduction and ligament reconstruction by a triceps tendon slip. In the four patients with anterior dislocation, good results were achieved; in the two with anterolateral dislocations bowing of the ulna persisted and subluxation recurred. One patient with an anterior dislocation developed a radio-ulnar synostosis. For anterolateral dislocations, we advise the combining of open reduction and ligament reconstruction with osteotomy of the ulna


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 6 | Pages 918 - 923
1 Nov 1997
Gendi NST Axon JMC Carr AJ Pile KD Burge PD Mowat AG

We carried out a survival analysis of elbow synovectomy (ES) and excision of the radial head (RHE) performed on 171 rheumatoid elbows. The failure criteria were revision surgery (performed or desired) and/or the presence of significant or severe pain. The cumulative survival was 81% at one year which thereafter decreased by an average of 2.6% per year. The strongest predictor for success was a low preoperative range of supination-pronation when corresponding survival curves were compared. A low range of flexion-extension also predicted failure. Combining both factors gave better prediction (failure: 6.3% v 67%), but a long duration of elbow symptoms before surgery predicted failure (72%, p = 0.04). At review, there was a mean gain of 50° in supination-pronation and 11° in flexion-extension; both correlated with success. Failure correlated with recurrence of synovitis, elbow instability, ulnar neuropathy, poor general mobility and poor upper-limb function. The last was independently affected by the severity of RA in the ipsilateral shoulder. Our findings show that although the short-term result of ES and RHE in rheumatoid arthritis is good, the long-term outcome is poor except in a subgroup with more than 50% limitation of forearm rotation


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 4 | Pages 639 - 642
1 Aug 1987
Hirayama T Takemitsu Y Yagihara K Mikita A

Nine children with chronic post-traumatic dislocation of the head of the radius were treated by an osteotomy of the ulna with over-correction of the angular deformity and with elongation of the bone. Satisfactory results were obtained in eight cases, the only poor outcome following a three-year delay between the initial injury and the reposition. The interosseous membrane of the forearm appeared to be the most important structure in maintaining the corrected position of the radial head


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 3 | Pages 422 - 424
1 May 1995
Arcalis Arce A Marti Garin D Molero Garcia V Pedemonte Jansana J

Since 1986 we have treated 15 patients with fractures of the head of the radius limited to one or two fragments (Mason type II) by open reduction and internal fixation with the Fibrin Adhesive System. At a mean follow-up of over two years, all but one of the results were excellent. This method is recommended for the treatment of selected fractures of the radial head followed by early mobilisation


The Journal of Bone & Joint Surgery British Volume
Vol. 33-B, Issue 2 | Pages 244 - 247
1 May 1951
Essex-Lopresti P


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 5 | Pages 846 - 847
1 Nov 1988
Freedman L Luk K Leong J


The Journal of Bone & Joint Surgery British Volume
Vol. 59-B, Issue 4 | Pages 402 - 407
1 Nov 1977
Lloyd-Roberts G Bucknill T

The results of operation for traumatic anterior dislocation of the head of the radius in eight children have been reviewed. We are satisfied on the basis of the results obtained and the outcome in one untreated patient that operative reduction is fully justified, provided that the annular ligament is reconstructed and internal fixation employed. We have not seen unilateral congenital dislocation and doubt its existence. Secondary subluxation of the distal radio-ulnar joint has been noted in an untreated patient.


The Journal of Bone & Joint Surgery British Volume
Vol. 51-B, Issue 4 | Pages 707 - 710
1 Nov 1969
Wood SK

Two cases of an unusual injury to the proximal end of the radius in children are reported illustrating a pitfall of closed manipulation. A review of the literature suggests that this injury is comparatively rare and is likely to be followed by permanent restriction of rotation of the forearm.


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 964 - 969
1 Sep 2024
Wang YC Song JJ Li TT Yang D Lv ZB Wang ZY Zhang ZM Luo Y

Aims. To propose a new method for evaluating paediatric radial neck fractures and improve the accuracy of fracture angulation measurement, particularly in younger children, and thereby facilitate planning treatment in this population. Methods. Clinical data of 117 children with radial neck fractures in our hospital from August 2014 to March 2023 were collected. A total of 50 children (26 males, 24 females, mean age 7.6 years (2 to 13)) met the inclusion criteria and were analyzed. Cases were excluded for the following reasons: Judet grade I and Judet grade IVb (> 85° angulation) classification; poor radiograph image quality; incomplete clinical information; sagittal plane angulation; severe displacement of the ulna fracture; and Monteggia fractures. For each patient, standard elbow anteroposterior (AP) view radiographs and corresponding CT images were acquired. On radiographs, Angle P (complementary to the angle between the long axis of the radial head and the line perpendicular to the physis), Angle S (complementary to the angle between the long axis of the radial head and the midline through the proximal radial shaft), and Angle U (between the long axis of the radial head and the straight line from the distal tip of the capitellum to the coronoid process) were identified as candidates approximating the true coronal plane angulation of radial neck fractures. On the coronal plane of the CT scan, the angulation of radial neck fractures (CTa) was measured and served as the reference standard for measurement. Inter- and intraobserver reliabilities were assessed by Kappa statistics and intraclass correlation coefficient (ICC). Results. Angle U showed the strongest correlation with CTa (p < 0.001). In the analysis of inter- and intraobserver reliability, Kappa values were significantly higher for Angles S and U compared with Angle P. ICC values were excellent among the three groups. Conclusion. Angle U on AP view was the best substitute for CTa when evaluating radial neck fractures in children. Further studies are required to validate this method. Cite this article: Bone Joint J 2024;106-B(9):964–969


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 227 - 231
1 Feb 2020
Lee SH Nam DJ Yu HK Kim JW

Aims. The purpose of this study was to evaluate the relationships between the degree of injury to the medial and lateral collateral ligaments (MCL and LCL) and associated fractures in patients with a posterolateral dislocation of the elbow, using CT and MRI. Methods. We retrospectively reviewed 64 patients who presented between March 2009 and March 2018 with a posterolateral dislocation of the elbow and who underwent CT and MRI. CT revealed fractures of the radial head, coronoid process, and medial and lateral humeral epicondyles. MRI was used to identify contusion of the bone and collateral ligament injuries by tear, partial or complete tear. Results. A total of 54 patients had a fracture; some had more than one. Radial head fractures were found in 25 patients and coronoid fractures in 42. Lateral and medial humeral epicondylar fractures were found in eight and six patients, respectively. Contusion of the capitellum was found in 43 patients and rupture of the LCL was seen in all patients (partial in eight and complete in 56), there was complete rupture of the MCL in 37 patients, partial rupture in 19 and eight had no evidence of rupture. The LCL tear did not significantly correlate with the presence of fracture, but the MCL rupture was complete in patients with a radial head fracture (p = 0.047) and there was significantly increased association in those without a coronoid fracture (p = 0.015). Conclusion. In posterolateral dislocation of the elbow, LCL ruptures are mostly complete, while the MCL exhibits various degrees of injury, which are significantly associated with the associated fractures. Cite this article: Bone Joint J 2020;102-B(2):227–231


The Bone & Joint Journal
Vol. 95-B, Issue 10 | Pages 1383 - 1387
1 Oct 2013
Lanting BA Ferreira LM Johnson JA Athwal GS King GJW

We measured the tension in the interosseous membrane in six cadaveric forearms using an in vitro forearm testing system with the native radial head, after excision of the radial head and after metallic radial head replacement. The tension almost doubled after excision of the radial head during simulated rotation of the forearm (p = 0.007). There was no significant difference in tension in the interosseous membrane between the native and radial head replacement states (p = 0.09). Maximal tension occurred in neutral rotation with both the native and the replaced radial head, but in pronation if the radial head was excised. Under an increasing axial load and with the forearm in a fixed position, the rate of increase in tension in the interosseous membrane was greater when the radial head was excised than for the native radial head or replacement states (p = 0.02). As there was no difference in tension between the native and radial head replacement states, a radial head replacement should provide a normal healing environment for the interosseous membrane after injury or following its reconstruction. Load sharing between the radius and ulna becomes normal after radial head Replacement. As excision of the radial head significantly increased the tension in the interosseous membrane it may potentially lead to its attritional failure over time. Cite this article: Bone Joint J 2013;95-B:1383–7


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1362 - 1369
1 Nov 2019
Giannicola G Calella P Bigazzi P Mantovani A Spinello P Cinotti G

Aims. The aim of this study was to analyze the results of two radiocapitellar prostheses in a large case series followed prospectively, with medium-term follow-up. Patients and Methods. A total of 31 patients with a mean age of 54 years (27 to 73) were analyzed; nine had primary osteoarthritis (OA) and 17 had post-traumatic OA, three had capitellar osteonecrosis, and two had a fracture. Overall, 17 Lateral Resurfacing Elbow (LRE) and 14 Uni-Elbow Radio-Capitellum Implant (UNI-E) arthroplasties were performed. Pre- and postoperative assessment involved the Mayo Elbow Performance Score (MEPS), the Quick Disabilities of the Arm, Shoulder and Hand (Q-DASH) score, and the modified American Shoulder Elbow Surgeons (m-ASES) score. Results. The mean follow-up was 6.8 years (3.8 to 11.5). The mean MEPS, m-ASES, and Q-DASH scores improved significantly by 50 (p < 0.001), 55 (p < 0.001), and 54 points (p < 0.001), respectively, with no differences being detected between the implants. Preoperative pronation and supination were worse in patients in whom the UNI-E was used. Two patients with the UNI-E implant had asymptomatic evidence of gross loosening. Conclusion. Radiocapitellar arthroplasty yielded a significant improvement in elbow function at a mean follow-up of 6.8 years, with a high implant survival rate when the LRE was used in patients with primary or post-traumatic OA, without radial head deformity, and when the UNI-E was used in patients in whom radial head excision was indicated. Cite this article: Bone Joint J 2019;101-B:1362–1369