Advertisement for orthosearch.org.uk
Results 21 - 40 of 232
Results per page:
The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 46 - 55
1 Jan 2021
Grzelecki D Walczak P Szostek M Grajek A Rak S Kowalczewski J

Aims. Calprotectin (CLP) is produced in neutrophils and monocytes and released into body fluids as a result of inflammation or infection. The aim of this study was to evaluate the utility of blood and synovial CLP in the diagnosis of chronic periprosthetic joint infection (PJI). Methods. Blood and synovial fluid samples were collected prospectively from 195 patients undergoing primary or revision hip and knee arthroplasty. Patients were divided into five groups: 1) primary total hip and knee arthroplasty performed due to idiopathic osteoarthritis (OA; n = 60); 2) revision hip and knee arthroplasty performed due to aseptic failure of the implant (AR-TJR; n = 40); 3) patients with a confirmed diagnosis of chronic PJI awaiting surgery (n = 45); 4) patients who have finished the first stage of the PJI treatment with the use of cemented spacer and were qualified for replantation procedure (SR-TJR; n = 25), and 5) patients with rheumatoid arthritis undergoing primary total hip and knee arthroplasty (RA; n = 25). CLP concentrations were measured quantitatively in the blood and synovial fluid using an immunoturbidimetric assay. Additionally, blood and synovial CRP, blood interleukin-6 (IL-6), and ESR were measured, and a leucocyte esterase (LE) strip test was performed. Results. Patients with PJI had higher CLP concentrations than those undergoing aseptic revision in blood (median PJI 2.14 mg/l (interquartile range (IQR) 1.37 to 3.56) vs AR-TJR 0.66 mg/l (IQR 0.3 to 0.83); p < 0.001) and synovial fluid samples (median PJI 20.46 mg/l (IQR 14.3 to 22.36) vs AR-TJR 0.7 mg/l (IQR 0.41 to 0.95); p < 0.001). With a cut-off value of 1.0 mg/l, blood CLP showed a sensitivity, specificity, positive predictive value, and negative predictive value of 93.3%, 87.5%, 89.4%, and 92.1%, respectively. For synovial fluid with a cut-off value of 1.5 mg/l, these were 95.6%, 95%, 95.5%, and 95%, respectively. Conclusion. This small study suggests that synovial and blood CLP are useful markers in chronic PJI diagnosis with similar or higher sensitivity and specificity than routinely used markers such as CRP, ESR, IL-6, and LE. CLP was not useful to differentiate patients with PJI from those with rheumatoid arthritis. Cite this article: Bone Joint J 2021;103-B(1):46–55


Bone & Joint Research
Vol. 9, Issue 5 | Pages 202 - 210
1 May 2020
Trotter AJ Dean R Whitehouse CE Mikalsen J Hill C Brunton-Sim R Kay GL Shakokani M Durst AZE Wain J McNamara I O’Grady J

Aims. This pilot study tested the performance of a rapid assay for diagnosing prosthetic joint infection (PJI), which measures synovial fluid calprotectin from total hip and knee revision patients. Methods. A convenience series of 69 synovial fluid samples from revision patients at the Norfolk and Norwich University Hospital were collected intraoperatively (52 hips, 17 knees) and frozen. Synovial fluid calprotectin was measured retrospectively using a new commercially available lateral flow assay for PJI diagnosis (Lyfstone AS) and compared to International Consensus Meeting (ICM) 2018 criteria and clinical case review (ICM-CR) gold standards. Results. According to ICM, 24 patients were defined as PJI positive and the remaining 45 were negative. The overall accuracy of the lateral flow test compared to ICM was 75.36% (52/69, 95% CI 63.51% to 84.95%), sensitivity and specificity were 75.00% (18/24, 95% CI 53.29% to 90.23%) and 75.56% (34/45, 95% CI 60.46% to 87.12%), respectively, positive predictive value (PPV) was 62.07% (18/29, 95% CI 48.23% to 74.19%) and negative predictive value (NPV) was 85.00% (34/40, 95% CI 73.54% to 92.04%), and area under the receiver operating characteristic (ROC) curve (AUC) was 0.78 (95% CI 0.66 to 0.87). Patient data from discordant cases were reviewed by the clinical team to develop the ICM-CR gold standard. The lateral flow test performance improved significantly when compared to ICM-CR, with accuracy increasing to 82.61% (57/69, 95% CI 71.59% to 90.68%), sensitivity increasing to 94.74% (18/19, 95% CI 73.97% to 99.87%), NPV increasing to 97.50% (39/40, 95% CI 85.20% to 99.62%), and AUC increasing to 0.91 (95% CI 0.81 to 0.96). Test performance was better in knees (100.00% accurate (17/17, 95% CI 80.49% to 100.00%)) compared to hips (76.92% accurate (40/52, 95% CI 63.16% to 87.47%)). Conclusion. This study demonstrates that the calprotectin lateral flow assay could be an effective diagnostic test for PJI, however additional prospective studies testing fresh samples are required. Cite this article:Bone Joint Res. 2020;9(5):202–210


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1218 - 1229
1 Oct 2019
Lerch TD Eichelberger P Baur H Schmaranzer F Liechti EF Schwab JM Siebenrock KA Tannast M

Aims. Abnormal femoral torsion (FT) is increasingly recognized as an additional cause for femoroacetabular impingement (FAI). It is unknown if in-toeing of the foot is a specific diagnostic sign for increased FT in patients with symptomatic FAI. The aims of this study were to determine: 1) the prevalence and diagnostic accuracy of in-toeing to detect increased FT; 2) if foot progression angle (FPA) and tibial torsion (TT) are different among patients with abnormal FT; and 3) if FPA correlates with FT. Patients and Methods. A retrospective, institutional review board (IRB)-approved, controlled study of 85 symptomatic patients (148 hips) with FAI or hip dysplasia was performed in the gait laboratory. All patients had a measurement of FT (pelvic CT scan), TT (CT scan), and FPA (optical motion capture system). We allocated all patients to three groups with decreased FT (< 10°, 37 hips), increased FT (> 25°, 61 hips), and normal FT (10° to 25°, 50 hips). Cluster analysis was performed. Results. We found a specificity of 99%, positive predictive value (PPV) of 93%, and sensitivity of 23% for in-toeing (FPA < 0°) to detect increased FT > 25°. Most of the hips with normal or decreased FT had no in-toeing (false-positive rate of 1%). Patients with increased FT had significantly (p < 0.001) more in-toeing than patients with decreased FT. The majority of the patients (77%) with increased FT walk with a normal foot position. The correlation between FPA and FT was significant (r = 0.404, p < 0.001). Five cluster groups were identified. Conclusion. In-toeing has a high specificity and high PPV to detect increased FT, but increased FT can be missed because of the low sensitivity and high false-negative rate. These results can be used for diagnosis of abnormal FT in patients with FAI or hip dysplasia undergoing hip arthroscopy or femoral derotation osteotomy. However, most of the patients with increased FT walk with a normal foot position. This can lead to underestimation or misdiagnosis of abnormal FT. We recommend measuring FT with CT/MRI scans in all patients with FAI. Cite this article: Bone Joint J 2019;101-B:1218–1229


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1300 - 1306
1 Oct 2019
Oliver WM Smith TJ Nicholson JA Molyneux SG White TO Clement ND Duckworth AD

Aims. The primary aim of this study was to develop a reliable, effective radiological score to assess the healing of humeral shaft fractures, the Radiographic Union Score for HUmeral fractures (RUSHU). The secondary aim was to assess whether the six-week RUSHU was predictive of nonunion at six months after the injury. Patients and Methods. Initially, 20 patients with radiographs six weeks following a humeral shaft fracture were selected at random from a trauma database and scored by three observers, based on the Radiographic Union Scale for Tibial fractures system. After refinement of the RUSHU criteria, a second group of 60 patients with radiographs six weeks after injury, 40 with fractures that united and 20 with fractures that developed nonunion, were scored by two blinded observers. Results. After refinement, the interobserver intraclass correlation coefficient (ICC) was 0.79 (95% confidence interval (CI) 0.67 to 0.87), indicating substantial agreement. At six weeks after injury, patients whose fractures united had a significantly higher median score than those who developed nonunion (10 vs 7; p < 0.001). A receiver operating characteristic curve determined that a RUSHU cut-off of < 8 was predictive of nonunion (area under the curve = 0.84, 95% CI 0.74 to 0.94). The sensitivity was 75% and specificity 80% with a positive predictive value (PPV) of 65% and a negative predictive value of 86%. Patients with a RUSHU < 8 (n = 23) were more likely to develop nonunion than those with a RUSHU ≥ 8 (n = 37, odds ratio 12.0, 95% CI 3.4 to 42.9). Based on a PPV of 65%, if all patients with a RUSHU < 8 underwent fixation, the number of procedures needed to avoid one nonunion would be 1.5. Conclusion. The RUSHU is reliable and effective in identifying patients at risk of nonunion of a humeral shaft fracture at six weeks after injury. This tool requires external validation but could potentially reduce the morbidity associated with delayed treatment of an established nonunion. Cite this article: Bone Joint J 2019;101-B:1300–1306


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 246 - 252
1 Mar 2019
Iwata E Scarborough M Bowden G McNally M Tanaka Y Athanasou NA

Aims. The aim of this study was to determine the diagnostic utility of histological analysis in spinal biopsies for spondylodiscitis (SD). Patients and Methods. Clinical features, radiology, results of microbiology, histology, and laboratory investigations in 50 suspected SD patients were evaluated. In 29 patients, the final (i.e. treatment-based) diagnosis was pyogenic SD; in seven patients, the final diagnosis was mycobacterial SD. In pyogenic SD, the neutrophil polymorph (NP) infiltrate was scored semi-quantitatively by determining the mean number of NPs per (×400) high-power field (HPF). Results. Of the 29 pyogenic SD patients, 17 had positive microbiology and 21 positive histology (i.e. one or more NPs per HPF on average). All non-SD patients showed less than one NP per HPF. The presence of one or more NPs per HPF had a diagnostic sensitivity of 72.4%, specificity 100%, accuracy 100%, positive predictive value (PPV) 81.0%, and negative predictive value (NPV) 61.9%. Sensitivity, specificity, and accuracy were greater using the criterion of positive histology and/or microbiology than positive histology or microbiology alone. Granulomas were identified histologically in seven mycobacterial SD patients, and positive microbiology was detected in four. Conclusion. The diagnosis of pyogenic SD was more often confirmed by positive histology (one or more NPs per HPF on average) than by microbiology, although diagnostic sensitivity was greater when both histology and microbiology were positive. Cite this article: Bone Joint J 2019;101-B:246–252


Bone & Joint Research
Vol. 9, Issue 5 | Pages 219 - 224
1 May 2020
Yang B Fang X Cai Y Yu Z Li W Zhang C Huang Z Zhang W

Aims. Preoperative diagnosis is important for revision surgery after prosthetic joint infection (PJI). The purpose of our study was to determine whether reverse transcription-quantitative polymerase chain reaction (RT-qPCR), which is used to detect bacterial ribosomal RNA (rRNA) preoperatively, can reveal PJI in low volumes of aspirated fluid. Methods. We acquired joint fluid samples (JFSs) by preoperative aspiration from patients who were suspected of having a PJI and failed arthroplasty; patients with preoperative JFS volumes less than 5 ml were enrolled. RNA-based polymerase chain reaction (PCR) and bacterial culture were performed, and diagnostic efficiency was compared between the two methods.According to established Musculoskeletal Infection Society (MSIS) criteria, 21 of the 33 included patients were diagnosed with PJI. Results. RNA-based PCR exhibited 57.1% sensitivity, 91.7% specificity, 69.7% accuracy, 92.3% positive predictive value, and 55.0% negative predictive value. The corresponding values for culture were 28.6%, 83.3%, 48.5%, 75.0%, and 40.0%, respectively. A significantly higher sensitivity was thus obtained with the PCR method versus the culture method. Conclusion. In situations in which only a small JFS volume can be acquired, RNA-based PCR analysis increases the utility of preoperative puncture for patients who require revision surgery due to suspected PJI. Cite this article:Bone Joint Res. 2020;9(5):219–224


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1176 - 1182
1 Sep 2017
Berger P Van Cauter M Driesen R Neyt J Cornu O Bellemans J

Aims. The purpose of this current multicentre study is to analyse the presence of alpha-defensin proteins in synovial fluid using the Synovasure lateral flow device and to determine its diagnostic reliability and accuracy compared with the prosthetic joint infection (PJI) criteria produced by the Musculoskeletal Infection Society (MSIS). Patients and Methods. A cohort of 121 patients comprising 85 total knee arthroplasties and 36 total hip arthroplasties was prospectively evaluated between May 2015 and June 2016 in three different orthopaedic centres. The tests were performed on patients with a chronically painful prosthesis undergoing a joint aspiration in a diagnostic pathway or during revision surgery. Results. Based on the MSIS criteria, 34 patients (28%) would have had a PJI, and 87 patients had no PJI. Testing with the lateral flow device had a sensitivity of 97.1% (95% confidence intervals (CI) 84.5 to 99.9) and a specificity of 96.6% (95% CI 90.3 to 99.2). The positive predictive value was 91.7% (95% CI 77.7% to 98.3), and the negative predictive value was 98.8% (95% CI 93.6 to 99.9). Receiver operator characteristics analysis demonstrated an area under the curve for the Synovasure test of 0.97 (95% CI 0.93 to 1.00). Conclusion. Our findings suggest that the Synovasure test has an excellent diagnostic performance to confirm or reject the diagnosis of a PJI. The results are promising for the care of the painful or problematic knee and hip joint arthroplasty and the test should be considered as part of the diagnostic toolbox for PJIs. Cite this article: Bone Joint J 2017;99-B:1176–82


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 713 - 719
1 Jun 2011
Duckworth AD Ring D McQueen MM

A suspected fracture of the scaphoid remains difficult to manage despite advances in knowledge and imaging methods. Immobilisation and restriction of activities in a young and active patient must be balanced against the risks of nonunion associated with an undiagnosed and undertreated fracture of the scaphoid. The assessment of diagnostic tests for a suspected fracture of the scaphoid must take into account two important factors. First, the prevalence of true fractures among suspected fractures is low, which greatly reduces the probability that a positive test will correspond with a true fracture, as false positives are nearly as common as true positives. This situation is accounted for by Bayesian statistics. Secondly, there is no agreed reference standard for a true fracture, which necessitates the need for an alternative method of calculating diagnostic performance characteristics, based upon a statistical method which identifies clinical factors tending to associate (latent classes) in patients with a high probability of fracture. The most successful diagnostic test to date is MRI, but in low-prevalence situations the positive predictive value of MRI is only 88%, and new data have documented the potential for false positive scans. The best strategy for improving the diagnosis of true fractures among suspected fractures of the scaphoid may well be to develop a clinical prediction rule incorporating a set of demographic and clinical factors which together increase the pre-test probability of a fracture of the scaphoid, in addition to developing increasingly sophisticated radiological tests


The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1545 - 1551
1 Nov 2017
Makki D Elgamal T Evans P Harvey D Jackson G Platt S

Aims. The aim of this paper was to present the clinical features of patients with musculoskeletal sources of methicillin-sensitive Staphylococcus aureus (MSSA) septicaemia. Patients and Methods. A total of 137 patients presented with MSSA septicaemia between 2012 and 2015. The primary source of infection was musculoskeletal in 48 patients (35%). Musculoskeletal infection was considered the primary source of septicaemia when endocarditis and other obvious sources were excluded. All patients with an arthroplasty at the time were evaluated for any prosthetic involvement. . Results. The most common site of infection was the spine, which occurred in 28 patients (58%), and was associated with abscess formation in 16. Back pain was the presenting symptom in these patients, with a positive predictive value of 100%. A total of 24 patients had a total of 42 arthroplasties of the hip or knee in situ. Prosthetic joint infection occurred in six of these patients (25%). In five patients, the infection originated outside the musculoskeletal system. Three patients (6%) with MSSA septicaemia from a musculoskeletal sources died. . Conclusion. Amongst the musculoskeletal sources of MSSA septicaemia, the spine was the most commonly involved. We recommend an MRI scan of the whole spine and pelvis in patients with MSSA septicaemia with back pain, when the primary source of infection has not been identified or clinical examination is unreliable. Cite this article: Bone Joint J 2017;99-B:1545–51


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 990 - 993
1 Jul 2005
Bar-On E Mashiach R Inbar O Weigl D Katz K Meizner I

Club foot was diagnosed by ultrasonography in 91 feet (52 fetuses) at a mean gestational age of 22.1 weeks (14 to 35.6). Outcome was obtained by chart review in 26 women or telephone interview in 26. Feet were classified as normal, positional deformity, isolated club foot or complex club foot. At initial diagnosis, 69 feet (40 fetuses) were classified as isolated club foot and 22 feet (12 fetuses) as complex club foot. The diagnosis was changed after follow-up ultrasound scan in 13 fetuses (25%), and the final ultrasound diagnosis was normal in one fetus, isolated club foot in 31 fetuses, and complex club foot in 20 fetuses. At birth, club foot was found in 79 feet in 43 infants for a positive predictive value of 83%. Accuracy of the specific diagnosis of isolated club foot or complex club foot was lower; 63% at the initial ultrasound scan and 73% at the final scan. The difference in diagnostic accuracy between isolated and complex club foot was not statistically significant. In no case was postnatal complex club foot undiagnosed on fetal ultrasound and all inaccuracies were overdiagnoses. Karyotyping was performed in 25 cases. Abnormalities were noted in three fetuses, all with complex club foot and with additional findings on ultrasound


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 889 - 892
1 Jul 2008
Al-Shawi A Badge R Bunker T

We have examined the accuracy of 143 consecutive ultrasound scans of patients who subsequently underwent shoulder arthroscopy for rotator-cuff disease. All the scans and subsequent surgery were performed by an orthopaedic surgeon using a portable ultrasound scanner in a one-stop clinic. There were 78 full thickness tears which we confirmed by surgery or MRI. Three moderate-size tears were assessed as partial-thickness at ultrasound scan (false negative) giving a sensitivity of 96.2%. One partially torn and two intact cuffs were over-diagnosed as small full-thickness tears by ultrasound scan (false positive) giving a specificity of 95.4%. This gave a positive predictive value of 96.2% and a negative predictive value of 95.4%. Estimation of tear size was more accurate for large and massive tears at 96.5% than for moderate (88.8%) and small tears (91.6%). These results are equivalent to those obtained by several studies undertaken by experienced radiologists. We conclude that ultrasound imaging of the shoulder performed by a sufficiently-trained orthopaedic surgeon is a reliable time-saving practice to identify rotator-cuff integrity


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 699 - 705
1 May 2013
Chin KF Misra VP Sicuri GM Fox M Sinisi M

We investigated the predictive value of intra-operative neurophysiological investigations in obstetric brachial plexus injuries. Between January 2005 and June 2011 a total of 32 infants of 206 referred to our unit underwent exploration of the plexus, including neurolysis. The findings from intra-operative electromyography, sensory evoked potentials across the lesion and gross muscular response to stimulation were evaluated. A total of 22 infants underwent neurolysis alone and ten had microsurgical reconstruction. Of the former, one was lost to follow-up, one had glenoplasty and three had subsequent nerve reconstructions. Of the remaining 17 infants with neurolysis, 13 (76%) achieved a modified Mallet score > 13 at a mean age of 3.5 years (0.75 to 6.25). Subluxation or dislocation of the shoulder is a major confounding factor. The positive predictive value and sensitivity of the intra-operative EMG for C5 were 100% and 85.7%, respectively, in infants without concurrent shoulder pathology. The positive and negative predictive values, sensitivity and specificity of the three investigations combined were 77%, 100%, 100% and 57%, respectively. In all, 20 infants underwent neurolysis alone for C6 and three had reconstruction. All of the former and one of the latter achieved biceps function of Raimondi grade 5. The positive and negative predictive values, sensitivity and specificity of electromyography for C6 were 65%, 71%, 87% and 42%, respectively. Our method is effective in evaluating the prognosis of C5 lesion. Neurolysis is preferred for C6 lesions. Cite this article: Bone Joint J 2013;95-B:699–705


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 4 | Pages 571 - 576
1 Apr 2005
Savarino L Granchi D Cenni E Baldini N Greco M Giunti A

There is no diagnostic, non-invasive method for the early detection of loosening after total hip arthroplasty. In a pilot study, we have analysed two serum markers of bone remodelling, procollagen I C-terminal extension peptide (PICP) and cross-linked N-terminal telopeptide (NTx), as well as the diagnostic performance of NTx for the assessment of osteolysis. We recruited 21 patients with loosening (group I), 18 with a well-fixed prosthesis (group II) and 17 at the time of primary arthroplasty for osteoarthritis (OA) (group III). Internal normal reference ranges were obtained from 30 healthy subjects (group IV). The serum PICP level was found to be significantly lower in patients with OA and those with loosening, when compared with those with stable implants, while the NTx level was significantly increased only in the group with loosening, suggesting that collagen degradation depended on the altered bone turnover induced by the implant. This hypothesis was reinforced by the finding that the values in the pre-surgery patients and stable subjects were comparable with the reference range of younger healthy subjects. A high specificity and positive predictive value for NTx provided good diagnostic evidence of agreement between the test and the clinical and radiological evaluations. The NTx level could be used to indicate stability of the implant. However, further prospective, larger studies are necessary


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 10 | Pages 1389 - 1394
1 Oct 2011
Soubeyrand M Ciais G Wassermann V Kalouche I Biau D Dumontier C Gagey O

Disruption of the interosseous membrane is easily missed in patients with Essex-Lopresti syndrome. None of the imaging techniques available for diagnosing disruption of the interosseous membrane are completely dependable. We undertook an investigation to identify whether a simple intra-operative test could be used to diagnose disruption of the interosseous membrane during surgery for fracture of the radial head and to see if the test was reproducible. We studied 20 cadaveric forearms after excision of the radial head, ten with and ten without disruption of the interosseous membrane. On each forearm, we performed the radius joystick test: moderate lateral traction was applied to the radial neck with the forearm in maximal pronation, to look for lateral displacement of the proximal radius indicating that the interosseous membrane had been disrupted. Each of six surgeons (three junior and three senior) performed the test on two consecutive days. Intra-observer agreement was 77% (95% confidence interval (CI) 67 to 85) and interobserver agreement was 97% (95% CI 92 to 100). Sensitivity was 100% (95% CI 97 to 100), specificity 88% (95% CI 81 to 93), positive predictive value 90% (95% CI 83 to 94), and negative predictive value 100%). This cadaveric study suggests that the radius joystick test may be useful for detecting disruption of the interosseous membrane in patients undergoing open surgery for fracture of the radial head and is reproducible. A confirmatory study in vivo is now required


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1351 - 1360
1 Oct 2006
Rajasekaran S Babu JN Dheenadhayalan J Shetty AP Sundararajan SR Kumar M Rajasabapathy S

Limb-injury severity scores are designed to assess orthopaedic and vascular injuries. In Gustilo type-IIIA and type-IIIB injuries they have poor sensitivity and specificity to predict salvage or outcome. We have designed a trauma score to grade the severity of injury to the covering tissues, the bones and the functional tissues, grading the three components from one to five. Seven comorbid conditions known to influence the management and prognosis have been given a score of two each. The score was validated in 109 consecutive open injuries of the tibia, 42 type-IIIA and 67 type-IIIB. The total score was used to assess the possibilities of salvage and the outcome was measured by dividing the injuries into four groups according to their scores as follows: group I scored less than 5, group II 6 to 10, group III 11 to 15 and group IV 16 or more. A score of 14 to indicate amputation had the highest sensitivity and specificity. Our trauma score compared favourably with the Mangled Extremity Severity score in sensitivity (98% and 99%), specificity (100% and 17%), positive predictive value (100% and 97.5%) and negative predictive value (70% and 50%), respectively. A receiver-operating characteristic curve constructed for 67 type-IIIB injuries to assess the efficiency of the scores to predict salvage, showed that the area under the curve for this score was better (0.988 (± 0.013 . sem. )) than the Mangled Extremity Severity score (0.938 (± 0.039 . sem. )). All limbs in group IV and one in group III underwent amputation. Of the salvaged limbs, there was a significant difference in the three groups for the requirement of a flap for wound cover, the time to union, the number of surgical procedures required, the total days as an in-patient and the incidence of deep infection (p < 0.001 for all). The individual scores for covering and functional tissues were also found to offer specific guidelines in the management of these complex injuries. The scoring system was found to be simple in application and reliable in prognosis for both limb-salvage and outcome measures in type-IIIA and type-IIIB open injuries of the tibia


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 2 | Pages 275 - 276
1 Mar 1990
Bough B Thakore J Davies M Dowling F

The reproduction of symptoms on arthrography of the lumbar facet joint has been accepted as a screening procedure before localised spinal fusion. We studied the histology of 127 facet joints removed at operation from 84 patients, who had previously had facet arthrography. The specificity of the arthrographic results for degenerative joint disease was 75% but their sensitivity was only 59%. This gave a positive predictive value of 85%, but a negative predictive value of only 43%. We conclude that the production of symptoms during facet arthrography is of little value as a screening procedure


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 3 | Pages 516 - 518
1 May 1990
Rojviroj S Sirichativapee W Kowsuwon W Wongwiwattananon J Tamnanthong N Jeeravipoolvarn P

We studied pressure in the carpal tunnel in patients with carpal tunnel syndrome and in normal control subjects, using a slit catheter and recording in the neutral position, 90 degrees dorsiflexion, and 90 degrees palmarflexion of the wrist. For each position the mean pressure in the patients was very significantly higher than in the controls, the highest pressure being in 90 degrees dorsiflexion, and the lowest in the neutral position. Using an upper limit of normal pressure of 5.5 mmHg in the neutral position gave a diagnostic sensitivity of 78.7%, a specificity of 78.1%, an accuracy of 78.5%, and a positive predictive value of 87.3%


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 1 | Pages 28 - 33
1 Jan 1995
Athanasou N Pandey R de Steiger R Crook D Smith P

We assessed the efficacy of intraoperative frozen-section histology in detecting infection in failed arthroplasties in 106 hips and knees. We found inflammatory changes consistent with infection (an average of one or more neutrophil polymorphs or plasma cells per high-power field in several samples) in 18 cases; there was a significant growth on bacterial culture in 20 cases. Compared with the bacterial cultures, the frozen sections provided two false-negative results and three false-positive results (sensitivity, 90%; specificity, 96%; and accuracy, 95%). The positive predictive value was 88%, the negative value, 98%. These results support the inclusion of intra-operative frozen-section histology in any protocol for revision arthroplasty for loose components


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 1 | Pages 83 - 89
1 Jan 2003
Yeom JS Kim WJ Choy WS Lee CK Chang BS Kang JW

We analysed the CT scans and radiographs of 76 vertebrae in 49 patients who underwent vertebroplasty for painful osteoporotic compression fractures. Leaks of cement were classified into three types: those via the basivertebral vein (type B), via the segmental vein (type S), and through a cortical defect (type C). More leaks were identified on CT scans than on radiographs by a factor of 1.5 (74/49). Most type-B (93%) and type-S (86%) leaks were missed or underestimated on a lateral radiograph which is usually the only view used during the injection of cement. Of the leaks into the spinal canal, only 7% (2/28) were correctly identified on radiographs. The areas on lateral radiographs where this type of leak may be observed were divided into four zones, and their diagnostic value in predicting a leak into the spinal canal was evaluated. The results showed that cement in the neural foramina had the highest positive predictive value (86%)


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 1 | Pages 37 - 44
1 Jan 2003
Röder C Eggli S Aebi M Busato A

We analysed follow-up data from 18 486 primary total hip arthroplasties performed between 1967 and 2001 to assess the validity of clinical procedures in diagnosing loosening of prosthetic components. Sensitivity, specificity and predictive values were estimated with the radiological definition of loose or not loose as the ‘gold standard’. The prevalence of acetabular loosening increased from 0.6% to 13.9% during the period of the study and that of femoral loosening from 0.9% to 12.1%. Sensitivities and positive predictive values were low, suggesting that clinical procedures could not replace radiological assessment in the identification of loose prostheses. Specificities and negative predictive values were constantly above 0.86. The possibility of there being a prosthesis which is not loose in asymptomatic patients was consequently very high, particularly during the first five to six years after operation. The necessity of periodic clinical and radiological follow-up examinations of asymptomatic patients during the first five to six years after operation remains questionable. Symptomatic patients, however, require radiological assessment