It has been hypothesized that patellofemoral pain, a common knee condition in adolescents and young adults, may be a precursor of degenerative joint changes and may ultimately lead to patellofemoral osteoarthritis. Since both conditions share several mechanical disease characteristics, such as altered contact area between the femur and patella and increased joint stress, we investigated whether these conditions share similar and different shape characteristics of the patella compared with normal controls. This cross-sectional study compared three different study populations: 32 patellofemoral pain subjects (mean age, 32 years (22 to 45); 72% female); 56 isolated radiological patellofemoral osteoarthritis subjects (mean age, 54 years (44 to 58); 89% female); and 80 healthy control subjects (mean age, 52 years (44 to 58); 74% female). Measurements included questionnaires, and lateral and skyline radiographs of the knee. Two separate 30-point 2D statistical shape models of the patella were created from the lateral and skyline radiographs. A general linear model was used to test for differences in standardized shape modes (a specific shape variant of the patella) between patellofemoral osteoarthritis, patellofemoral pain, and controls, using Bonferroni correction and adjustment for body mass index and gender.Objectives
Methods
Patient-specific glenoid guides (PSGs) claim an improvement in
accuracy and reproducibility of the positioning of components in
total shoulder arthroplasty (TSA). The results have not yet been
confirmed in a prospective clinical trial. Our aim was to assess
whether the use of PSGs in patients with osteoarthritis of the shoulder
would allow accurate and reliable implantation of the glenoid component. A total of 17 patients (three men and 14 women) with a mean age
of 71 years (53 to 81) awaiting TSA were enrolled in the study.
Pre- and post-operative version and inclination of the glenoid were
measured on CT scans, using 3D planning automatic software. During
surgery, a congruent 3D-printed PSG was applied onto the glenoid
surface, thus determining the entry point and orientation of the
central guide wire used for reaming the glenoid and the introduction
of the component. Manual segmentation was performed on post-operative
CT scans to compare the planned and the actual position of the entry
point (mm) and orientation of the component (°).Aims
Patients and Methods
This study aimed to examine the effects of SRT1720, a potent SIRT1 activator, on osteoarthritis (OA) progression using an experimental OA model. Osteoarthritis was surgically induced by destabilization of the medial meniscus in eight-week-old C57BL/6 male mice. SRT1720 was administered intraperitoneally twice a week after surgery. Osteoarthritis progression was evaluated histologically using the Osteoarthritis Research Society International (OARSI) score at four, eight, 12 and 16 weeks. The expression of SIRT1, matrix metalloproteinase 13 (MMP-13), a disintegrin and metalloproteinase with thrombospondin motifs-5 (ADAMTS-5), cleaved caspase-3, PARP p85, and acetylated nuclear factor (NF)-κB p65 in cartilage was examined by immunohistochemistry. Synovitis was also evaluated histologically. Primary mouse epiphyseal chondrocytes were treated with SRT1720 in the presence or absence of interleukin 1 beta (IL-1β), and gene expression changes were examined by real-time polymerase chain reaction (PCR).Objectives
Methods
The aim of this study was to compare the post-operative radiographic
and clinical outcomes between kinematically and mechanically aligned
total knee arthroplasties (TKAs). A total of 60 TKAs (30 kinematically and 30 mechanically aligned)
were performed in 60 patients with varus osteoarthritis of the knee
using a navigation system. The angles of orientation of the joint
line in relation to the floor, the conventional and true mechanical
axis (tMA) (the line from the centre of the hip to the lowest point
of the calcaneus) were compared, one year post-operatively, on single-leg
and double-leg standing long leg radiographs between the groups.
The range of movement and 2011 Knee Society Scores were also compared
between the groups at that time.Aims
Patients and Methods
Arthroscopy of the native hip is an established diagnostic and therapeutic procedure. Its application in the symptomatic replaced hip is still being explored. We describe the use of arthroscopy of the hip in 24 symptomatic patients following total hip replacement, resurfacing arthroplasty of the hip and partial resurfacing (study group), and compared it with arthroscopy of the native hip in 24 patients (control group). A diagnosis was made or confirmed at arthroscopy in 23 of the study group and a therapeutic arthroscopic intervention resulted in relief of symptoms in ten of these. In a further seven patients it led to revision hip replacement. In contrast, arthroscopy in the control group was diagnostic in all 24 patients and the resulting arthroscopic therapeutic intervention provided symptomatic relief in 21. The mean operative time in the study group (59.7 minutes (35 to 93)) was less than in the control group (71 minutes (40 to 100), p = 0.04) but the arthroscopic approach was more difficult in the arthroplasty group. We suggest that arthroscopy has a role in the management of patients with a symptomatic arthroplasty when other investigations have failed to provide a diagnosis.
We evaluated clinical and radiographic outcomes of total shoulder
arthroplasty (TSA) using the second-generation Trabecular Metal
(TM) Glenoid component. The first generation component was withdrawn
in 2005 after a series of failures were reported. Between 2009 and
2012, 40 consecutive patients with unilateral TSA using the second-generation
component were enrolled in this clinical study. The mean age of
the patients was 63.8 years (40 to 75) and the mean follow-up was
38 months (24 to 42). Patients were evaluated using the Constant score (CS), the American
Shoulder and Elbow Surgeons (ASES) score and routine radiographs.Aims
Methods
Deformity of the proximal femur in fibrous dysplasia
leads to deviation of the mechanical axis of the hip, which may lead
to the development of secondary osteoarthritis (OA). This study
investigated the prevalence and predisposing factors for the development
of OA in patients with fibrous dysplasia of the proximal femur.
We reviewed the records of 209 patients from our institutional database
with fibrous dysplasia of the proximal femur, investigating possible predisposing
factors including patient demographics, the extent of the coxa vara
deformity, the presence of peri-articular disease, and the overall
burden of skeletal disease. Of the 209 patients, 24 (12%) had radiological
evidence of OA in the ipsilateral hip. The prevalence was significantly
higher in patients with polyostotic fibrous dysplasia compared with
those with monostotic disease (p <
0.001). In a subgroup analysis of
patients with polyostotic disease, the extent of deformity (quantified
using the neck–shaft angle), and the presence of peri-articular
disease (whether in the head of the femur or the acetabulum) were
significant predictors of osteoarthritis (neck–shaft angle likelihood
ratio (LR) = 0.847 per 1° increase, p = 0.004; presence of lesion
in the head of the femur LR = 9.947, p = 0.027; presence of lesion
in the acetabulum LR = 11.231, p = 0.014). Our data suggest that patients with polyostotic fibrous dysplasia
have a high risk of developing secondary OA of the hips. This risk
is higher in patients with peri-articular disease, and those with
a more severe deformity of proximal femur. Cite this article:
In Japan, osteoarthritis (OA) of the hip secondary
to acetabular dysplasia is very common, and there are few data concerning
the pathogeneses and incidence of femoroacetabular impingement (FAI).
We have attempted to clarify the radiological prevalence of painful
FAI in a cohort of Japanese patients and to investigate the radiological findings.
We identified 176 symptomatic patients (202 hips) with Tönnis grade
0 or 1 osteoarthritis, whom we prospectively studied between August
2011 and July 2012. There were 61 men (65 hips) and 115 women (137
hips) with a mean age of 51.8 years (11 to 83). Radiological analyses
included the α-angle, centre–edge angle, cross-over sign, pistol
grip deformity and femoral head neck ratio. Of the 202 hips, 79
(39.1%) had acetabular dysplasia, while 80 hips (39.6%) had no known
aetiology. We found evidence of FAI in 60 hips (29.7%). Radiological
FAI findings associated with cam deformity were the most common.
There was a significant relationship between the pistol grip deformity
and both the α-angle (p <
0.001) and femoral head–neck ratio
(p = 0.024). Radiological evidence of symptomatic FAI was not uncommon
in these Japanese patients. Cite this article:
We report the incidence and intensity of persistent
pain in patients with an otherwise uncomplicated total ankle replacement
(TAR). Arthroscopic debridement was performed in selected cases
and the clinical outcome was analysed. Among 120 uncomplicated TARs, there was persistent pain with
a mean visual analogue scale (VAS) of 2.7 (0 to 8). The intensity
of pain decreased in 115 ankles (95.8%). Exercise or walking for
more than 30 minutes was the most common aggravating factor (62
ankles, 68.1%). The character of the pain was most commonly described
as dull (50 ankles, 54.9%) and located on the medial aspect of the
joint (43 ankles, 47.3%). A total of seven ankles (5.8%) underwent subsequent arthroscopy.
These patients had local symptoms and a VAS for pain ≥ 7 on exertion.
Impingement with fibrosis and synovitis was confirmed. After debridement,
the median VAS decreased from 7 to 3 and six patients were satisfied.
The median VAS for pain and the American Orthopaedic Foot and Ankle
Society score of the ankles after debridement was similar to that
of the uncomplicated TARs (p = 0.496 and p = 0.066, respectively). Although TAR reduces the intensity of pain, residual pain is
not infrequent even in otherwise uncomplicated TARs and soft-tissue
impingement is the possible cause. Cite this article:
We assessed the long-term (20 years) outcome
of closed reduction and immobilisation in 19 patients with an isolated
fracture of the posterior malleolus of the ankle treated at a single
hospital between 1985 and 1990. The assessments used were an Olerud
functional questionnaire score, physical examination using a loaded
dorsal and plantar range of movement measurement, radiological analysis
of medial joint space widening, the Cedell score for anatomical
alignment of all three malleoli, and the radiological presence of
osteoarthritic change. There were excellent or good results in 14 patients (74%) according
to the Olerud score, in 18 patients (95%) according to loaded dorsal
and plantar range of movement assessment, in 16 patients (84%) as
judged by the Cedell score, and for osteoarthritis 18 patients (95%)
had an excellent or good score. There were no poor outcomes. There was
no correlation between the size of the fracture gap and the proportion
of the tibiotalar contact area when compared with the clinical results
(gap size: rho values -0.16 to 0.04, p ≥ 0.51; tibiotalar contact
area: rho values -0.20 to -0.03, p ≥ 0.4). Conservative treatment
of ‘isolated’ posterior malleolar fractures resulted in good clinical
and radiological outcome in this series at long-term follow-up.
The efficacy of circumpatellar electrocautery in reducing the incidence of post-operative anterior knee pain is unknown. We conducted a single-centre, outcome-assessor and patient-blinded, parallel-group, randomised, controlled trial to compare circumpatellar electrocautery with no electrocautery in total knee replacement in the absence of patellar resurfacing. Patients requiring knee replacement for primary osteoarthritis were randomly assigned circumpatellar electrocautery (intervention group) or no electrocautery (control group). The primary outcome measure was the incidence of anterior knee pain. A secondary measure was the standardised clinical and patient-reported outcomes determined by the American Knee Society scores and the Western Ontario and McMaster Universities (WOMAC) osteoarthritis index. A total of 131 knees received circumpatellar electrocautery and 131 had no electrocautery. The overall incidence of anterior knee pain at follow-up at one year was 26% (20% to 31%), with 19% (12% to 26%) in the intervention group and 32% (24% to 40%) in the control group (p = 0.02). The relative risk reduction from electrocautery was 40% (9% to 61%) and the number needed to treat was 7.7 (4.3 to 41.4). The intervention group had a better mean total WOMAC score at follow-up at one year compared with the control group (16.3 (0 to 77.7) Our study suggests that in the absence of patellar resurfacing electrocautery around the margin of the patella improves the outcome of total knee replacement.
Osteoarthritis (OA) is an important cause of
pain, disability and economic loss in humans, and is similarly important in
the horse. Recent knowledge on post-traumatic OA has suggested opportunities
for early intervention, but it is difficult to identify the appropriate
time of these interventions. The horse provides two useful mechanisms
to answer these questions: 1) extensive experience with clinical
OA in horses; and 2) use of a consistently predictable model of
OA that can help study early pathobiological events, define targets
for therapeutic intervention and then test these putative therapies.
This paper summarises the syndromes of clinical OA in horses including
pathogenesis, diagnosis and treatment, and details controlled studies
of various treatment options using an equine model of clinical OA.
We examined the reliability of radiological findings in predicting segmental instability in 112 patients (56 men, 56 women) with a mean age of 66.5 years (27 to 84) who had degenerative disease of the lumbar spine. They underwent intra-operative biomechanical evaluation using a new measurement system. Biomechanical instability was defined as a segment with a neutral zone >
2 mm/N. Risk factor analysis to predict instability was performed on radiographs (range of segmental movement, disc height), MRI (Thompson grade, Modic type), and on the axial CT appearance of the facet (type, opening, vacuum and the presence of osteophytes, subchondral erosion, cysts and sclerosis) using multivariate logistic regression analysis with a forward stepwise procedure. The facet type was classified as sagittally orientated, coronally orientated, anisotropic or wrapped. Stepwise multivariate regression analysis revealed that facet opening was the strongest predictor for instability (odds ratio 5.022, p = 0.009) followed by spondylolisthesis, MRI grade and subchondral sclerosis. Forward stepwise multivariate logistic regression indicated that spondylolisthesis, MRI grade, facet opening and subchondral sclerosis of the facet were risk factors. Symptoms evaluated by the Short-Form 36 and visual analogue scale showed that patients with an unstable segment were in significantly more pain than those without. Furthermore, the surgical procedures determined using the intra-operative measurement system were effective, suggesting that segmental instability influences the symptoms of lumbar degenerative disease.
Bone mineral density (BMD) around the femoral component has been reported to decrease after total knee replacement (TKR) because of stress shielding. Our aim was to determine whether a cemented mobile-bearing component reduced the post-operative loss of BMD. In our study 28 knees receiving a cemented fixed-bearing TKR were matched with 28 receiving a cemented mobile-bearing TKR. They underwent dual-energy x-ray absorptiometry, pre-operatively and at three weeks and at three, six, 12, 18 and 24 months post-operatively. The patients were not taking medication to improve the BMD. The pre-operative differences in the BMD of the femoral neck, wrist, lumbar spine and knee in the two groups were not significant. The BMD of the femur decreased postoperatively in the fixed-bearing group, but not the mobile-bearing group. The difference in the post-operative change in the BMD in the two groups was statistically significant (p <
0.05) at 18 and 24 months. Our findings show that a cemented mobile-bearing TKR has a favourable effect on the BMD of the distal femur after TKR in the short term. Further study is required to determine the long-term effects.
In an osteological collection of 3100 specimens, 70 were found with unilateral clavicular fractures which were matched with 70 randomly selected normal specimens. This formed the basis of a study of the incidence of arthritis of the acromioclavicular joint and the effect of clavicular fracture on the development of arthritis in the ipsilateral acromioclavicular joint. This was graded visually on a severity scale of 0 to 3. The incidence of moderate to severe arthritis of the acromioclavicular joint in normal specimens was 77% (100 specimens). In those with a clavicular fracture, 66 of 70 (94%) had arthritis of the acromioclavicular joint, compared to 63 of 70 (90%) on the non-injured contralateral side (p = 0.35). Clavicles with shortening of 15 mm or less had no difference in the incidence of arthritis compared to those with shortening greater than 15 mm (p = 0.25). The location of the fracture had no effect on the development of arthritis.
The patellar clunk syndrome describes painful catching, grinding or jumping of the patella when the knee moves from a flexed to an extended position after total knee replacement (TKR). The posterior stabilised TKR had been noted to have a higher incidence of this problem. Mobile-bearing posteriorly stabilised TKRs have been introduced to improve patellar tracking and related problems by a mechanism of self-alignment. We evaluated the patellar clunk syndrome in 113 knees in 93 patients with such a TKR at a mean follow-up of 2.3 years (2.0 to 3.2). The syndrome was identified in 15 knees (13.3%). Logistic regression analysis showed that the absolute value of the post-operative angle of patellar tilt was significantly associated with the occurrence of patellar clunk (p = 0.025). Patellar tracking should be carefully checked during surgery.
We retrospectively reviewed 35 cemented unicompartmental knee replacements performed for medial unicompartmental osteoarthritis of the knee in 31 patients ≤50 years old (mean 46, 31 to 49). Patients were assessed clinically and radiologically using the Knee Society scores at a mean follow-up of 9.7 years (5 to 16) and survival at 12 years was calculated. The mean Knee Society Function Score improved from 54 points (25 to 64) pre-operatively to 89 (80 to 100) post-operatively (p <
0.0001). Six knees required revision, four for polyethylene wear treated with an isolated exchange of the tibial insert, one for aseptic loosening and one for progression of osteoarthritis. The 12-year survival according to Kaplan-Meier was 80.6% with revision for any reason as the endpoint. Despite encouraging clinical results, polyethylene wear remains a major concern affecting the survival of unicompartmental knee replacement in patients younger than 50.
The generally-accepted treatment for large, displaced fractures of the glenoid associated with traumatic anterior dislocation of the shoulder is operative repair. In this study, 14 consecutive patients with large (>
5 mm), displaced (>
2 mm) anteroinferior glenoid rim fractures were treated non-operatively if post-reduction radiographs showed a centred glenohumeral joint. After a mean follow-up of 5.6 years (2.8 to 8.4), the mean Constant score and subjective shoulder value were 98% (90% to 100%) and 97% (90% to 100%), respectively. There were no redislocations or subluxations, and the apprehension test was negative. All fragments healed with an average intra-articular step of 3.0 mm (0.5 to 11). No patient had symptoms of osteoarthritis, which was mild in two shoulders and moderate in one. Traumatic anterior dislocation of the shoulder, associated with a large displaced glenoid rim fracture can be successfully treated non-operatively, providing the glenohumeral joint is concentrically reduced on the anteroposterior radiograph.
The aim of this study was to assess whether a femoral component which retained the neck reduced the incidence of leg-length inequality following total hip arthroplasty. A retrospective review was undertaken of 130 consecutive primary total hip arthroplasties performed between April 1996 and April 2004 using such an implant. There were 102 suitable patients for the study. Standardised pre- and post-operative pelvic radiographs were measured by an independent investigator to the nearest millimetre. The leg-length inequality was reduced from a mean pre-operative value of −0.71 cm to a mean of 0.11 cm post-operatively. Of the 102 patients 24 (23.5%) had an equal leg-length post-operatively, and 95 (93.1%) had a leg-length inequality between −1 cm and 1 cm.
After obtaining informed consent, 80 patients were randomised to undergo a navigated or conventional total knee replacement. All received a cemented, unconstrained, cruciate-retaining implant with a rotating platform. Full-length standing and lateral radiographs and CT scans of the hip, knee and ankle joint were carried out five to seven days after operation. No notable differences were found between computer-assisted navigation and conventional implantation techniques as regards the rotational alignment of the femoral or tibial components. Although the deviation from the transepicondylar axis was relatively low, there was a considerable range of deviation for the tibial rotational alignment. There was no statistically significant difference regarding the occurrence pattern of outliers in mechanical malalignment but the number of outliers was reduced in the navigated group.