Recent publications have drawn attention to the fact that some brands of joint replacement may contain variants which perform significantly worse (or better) than their ‘siblings’. As a result, the National Joint Registry has performed much more detailed analysis on the larger families of knee arthroplasties in order to identify exactly where these differences may be present and may hitherto have remained hidden. The analysis of the Nexgen knee arthroplasty brand identified that some posterior-stabilized combinations have particularly high revision rates for aseptic loosening of the tibia, and consequently a medical device recall has been issued for the Nexgen ‘option’ tibial component which was implicated. More elaborate signal detection is required in order to identify such variation in results in a routine fashion if patients are to be protected from such variation in outcomes between closely related implant types. Cite this article:
Instability is a common cause of failure after total hip arthroplasty. A novel reverse total hip has been developed, with a femoral cup and acetabular ball, creating enhanced mechanical stability. The purpose of this study was to assess the implant fixation using radiostereometric analysis (RSA), and the clinical safety and efficacy of this novel design. Patients with end-stage osteoarthritis were enrolled in a prospective cohort at a single centre. The cohort consisted of 11 females and 11 males with mean age of 70.6 years (SD 3.5) and BMI of 31.0 kg/m2 (SD 5.7). Implant fixation was evaluated using RSA as well as Western Ontario and McMaster Universities Osteoarthritis Index, Harris Hip Score, Oxford Hip Score, Hip disability and Osteoarthritis Outcome Score, 38-item Short Form survey, and EuroQol five-dimension health questionnaire scores at two-year follow-up. At least one acetabular screw was used in all cases. RSA markers were inserted into the innominate bone and proximal femur with imaging at six weeks (baseline) and six, 12, and 24 months. Independent-samples Aims
Methods
The aim of this review is to evaluate the current
available literature evidencing on peri-articular hip endoscopy
(the third compartment). A comprehensive approach has been set on
reports dealing with endoscopic surgery for recalcitrant trochanteric
bursitis, snapping hip (or coxa-saltans; external and internal),
gluteus medius and minimus tears and endoscopy (or arthroscopy)
after total hip arthroplasty. This information can be used to trigger
further research,
Cite this article:
Cite this article:
Most proximal humeral fractures are stable injuries of the ageing population, and can be successfully treated non-operatively. The management of the smaller number of more complex displaced fractures is more controversial and new fixation techniques have greatly increased the range of fractures that may benefit from surgery. This article explores current concepts in the classification and clinical aspects of these injuries, reviewing the indications,
The credibility and creativity of an author may be gauged by the number of scientific papers he or she has published, as well as the frequency of citations of a particular paper reflecting the impact of the data on the area of practice. The object of this study was to identify and analyse the qualities of the top 100 cited papers in orthopaedic surgery. The database of the Science Citation Index of the Institute for Scientific Information (1945 to 2008) was used. A total of 1490 papers were cited more than 100 times, with the top 100 being subjected to further analysis. The majority originated in the United States, followed by the United Kingdom. The top 100 papers were published in seven specific orthopaedic journals. Analysis of the most-cited orthopaedic papers allows us a unique insight into the qualitites, characteristics and clinical
Cite this article:
Fixation techniques used in the treatment of slipped capital femoral epiphysis (SCFE) that allow continued growth of the femoral neck, rather than inducing epiphyseal fusion in situ, have the advantage of allowing remodelling of the deformity. The aims of this study were threefold: to assess whether the Free-Gliding (FG) SCFE screw prevents further slip; to establish whether, in practice, it enables lengthening and gliding; and to determine whether the age of the patient influences the extent of glide. All patients with SCFE who underwent fixation using FG SCFE screws after its introduction at our institution, with minimum three years’ follow-up, were reviewed retrospectively as part of ongoing governance. All pre- and postoperative radiographs were evaluated. The demographics of the patients, the grade of slip, the extent of lengthening of the barrel of the screw and the restoration of Klein’s line were recorded. Subanalysis was performed according to sex and age.Aims
Methods