A clay containing hydroxyapatite (HA) was developed for use as a filling material between an uncemented implant and bone. It consists of 55% HA granules greater than 0.1 mm in size with a homogeneous pore distribution and a porosity of 35% to 48% in a saline solution of sodium alginate (6%). Ti-6A1-4V alloy rods with smooth surfaces were implanted into the distal medullary canal of one osteotomised tibia of 32 Japanese white rabbits. Sixteen rods were inserted with HA clay and 16 without the clay to act as a control group. Six of each group were killed at one week and ten at 12 weeks postoperatively. The pull-out strength of the implants with HA clay was significantly greater at 12 weeks (p <
0.05), as was the percentage of the area of the new bone (p <
0.05). The study suggests that HA clay has an osteoconductive property, allowing adequate bone fixation across a
There are two techniques widely used to determine the rotational
alignment of the components in total knee arthroplasty (TKA); gap
balancing (GB) and measured resection (MR). Which technique is the
best remains controversial. We aimed to investigate this in a systematic
review and meta-analysis. In accordance with the methods of Cochrane, databases were searched
for all randomised controlled trials in the literature between January
1986 and June 2015 comparing radiographic and clinical outcomes
between the use of these two tecniques. Meta-analysis involved the
use of the Revman5.3 software provided by Cochrane collaboration.Aims
Materials and Methods
The success of total knee replacement (TKR) depends
on optimal soft-tissue balancing, among many other factors. The
objective of this study is to correlate post-operative anteroposterior
(AP) translation of a posterior cruciate ligament-retaining TKR
with clinical outcome at two years. In total 100 patients were divided
into three groups based on their AP translation as measured by the
KT-1000 arthrometer. Group 1 patients had AP translation <
5
mm, Group 2 had AP translation from 5 mm to 10 mm, and Group 3 had
AP translation >
10 mm. Outcome assessment included range of movement
of the knee, the presence of flexion contractures, hyperextension,
knee mechanical axes and functional outcome using the Knee Society
score, Oxford knee score and the Short-Form 36 questionnaire. At two years, patients in Group 2 reported significantly better
Oxford knee scores than the other groups (p = 0.045). A positive
correlation between range of movement and AP translation was noted,
with patients in group 3 having the greatest range of movement (mean
flexion: 117.9° (106° to 130°)) (p <
0.001). However, significantly
more patients in Group 3 developed hyperextension >
10° (p = 0.01). In this study, the best outcome for cruciate-ligament retaining
TKR was achieved in patients with an AP translation of 5 mm to 10
mm.
A cortical bone graft on a muscle pedicle was taken from the ulna and transferred to bridge a complete defect of the radius in 16 dogs. In 14 control dogs a free graft was used, that is, one without a muscle pedicle. Union in the group with pedicle grafts was far superior to that in the group with free grafts, mainly because in those with pedicle grafts there was good subperiosteal new bone formation from active viable periosteum. In six of the pedicle grafts the viability of some osteocytes was retained over a 12-week period and in five the graft was almost completely replaced by new bone.
Aims. Periprosthetic fracture and implant loosening are two of the major reasons for revision surgery of cementless implants. Optimal implant fixation with minimal bone damage is challenging in this procedure. This pilot study investigates whether vibratory implant insertion is gentler compared to consecutive single blows for acetabular component implantation in a surrogate polyurethane (PU) model. Methods. Acetabular components (cups) were implanted into 1 mm nominal under-sized cavities in PU foams (15 and 30 per cubic foot (PCF)) using a vibratory implant insertion device and an automated impaction device for single blows. The impaction force, remaining polar
Aims. To evaluate whether low-intensity pulsed ultrasound (LIPUS) accelerates bone healing at osteotomy sites and promotes functional recovery after open-wedge high tibial osteotomy (OWHTO). Methods. Overall, 90 patients who underwent OWHTO without bone grafting were enrolled in this nonrandomized retrospective study, and 45 patients treated with LIPUS were compared with 45 patients without LIPUS treatment in terms of bone healing and functional recovery postoperatively. Clinical evaluations, including the pain visual analogue scale (VAS) and Japanese Orthopaedic Association (JOA) score, were performed preoperatively as well as six weeks and three, six, and 12 months postoperatively. The progression rate of
Aims. In this study, we aimed to explore surgical variations in the Femoral Neck System (FNS) used for stable fixation of Pauwels type III femoral neck fractures. Methods. Finite element models were established with surgical variations in the distance between the implant tip and subchondral bone, the
The recently published Prophylactic Antibiotic Regimens In Tumor Surgery (PARITY) trial found no benefit in extending antibiotic prophylaxis from 24 hours to five days after endoprosthetic reconstruction for lower limb bone tumours. PARITY is the first randomized controlled trial in orthopaedic oncology and is a huge step forward in understanding antibiotic prophylaxis. However, significant
Aims. Multiligament knee injuries (MLKI) are devastating injuries that can result in significant morbidity and time away from sport. There remains considerable variation in strategies employed for investigation, indications for operative intervention, outcome reporting, and rehabilitation following these injuries. At present no study has yet provided a comprehensive overview evaluating the extent, range, and overall summary of the published literature pertaining to MLKI. Our aim is to perform a methodologically rigorous scoping review, mapping the literature evaluating the diagnosis and management of MLKI. Methods. This scoping review will address three aims: firstly, to map the current extent and nature of evidence for diagnosis and management of MLKI; secondly, to summarize and disseminate existing research findings to practitioners; and thirdly, to highlight
Aims. Proper preoperative planning benefits fracture reduction, fixation, and stability in tibial plateau fracture surgery. We developed and clinically implemented a novel workflow for 3D surgical planning including patient-specific drilling guides in tibial plateau fracture surgery. Methods. A prospective feasibility study was performed in which consecutive tibial plateau fracture patients were treated with 3D surgical planning, including patient-specific drilling guides applied to standard off-the-shelf plates. A postoperative CT scan was obtained to assess whether the screw directions, screw lengths, and plate position were performed according the preoperative planning. Quality of the fracture reduction was assessed by measuring residual intra-articular incongruence (maximum
Aims. The aim of the study was to investigate whether the primary stability of press-fit acetabular components can be improved by altering the impaction procedure. Methods. Three impaction procedures were used to implant acetabular components into human cadaveric acetabula using a powered impaction device. An impaction frequency of 1 Hz until complete component seating served as reference. Overimpaction was simulated by adding ten strokes after complete component seating. High-frequency implantation was performed at 6 Hz. The lever-out moment of the acetabular components was used as measure for primary stability. Permanent bone deformation was assessed by comparison of double micro-CT (µCT) measurements before and after impaction. Acetabular component deformation and impaction forces were recorded, and the extent of bone-implant contact was determined from 3D laser scans. Results. Overimpaction reduced primary acetabular component stability (p = 0.038) but did not significantly increase strain release after implantation (p = 0.117) or plastic deformations (p = 0.193). Higher press-fits were associated with larger polar
Aims. Sagittal plane imbalance (SPI), or asymmetry between extension and flexion
Aims. The objectives of this study were to assess the effect of anterior cruciate ligament (ACL) resection on flexion-extension
Aims. The aim of this study was to assess the effect of posterior cruciate ligament (PCL) resection on flexion-extension
Aims. The Chopart joint complex is a joint between the midfoot and hindfoot. The static and dynamic support system of the joint is critical for maintaining the medial longitudinal arch of the foot. Any dysfunction leads to progressive collapsing flatfoot deformity (PCFD). Often, the tibialis posterior is the primary cause; however, contrary views have also been expressed. The present investigation intends to explore the comprehensive anatomy of the support system of the Chopart joint complex to gain insight into the cause of PCFD. Methods. The study was conducted on 40 adult embalmed cadaveric lower limbs. Chopart joint complexes were dissected, and the structures supporting the joint inferiorly were observed and noted. Results. The articulating bones exhibit features like a cuboid shelf and navicular beak, which appear to offer inferior support to the joint. The expanse of the spring ligament complex is more medial than inferior, while the superomedial part is more extensive than the intermediate and inferoplantar parts. The spring ligament is reinforced by the tendons in the superomedial part (the main tendon of tibialis posterior), the inferomedial part (the plantar slip of tibialis posterior), and the master knot of Henry positioned just inferior to the
Aims. The aims of this study were to determine the effect of osteophyte excision on deformity correction and soft tissue
Aims. Machine-learning (ML) prediction models in orthopaedic trauma hold great promise in assisting clinicians in various tasks, such as personalized risk stratification. However, an overview of current applications and critical appraisal to peer-reviewed guidelines is lacking. The objectives of this study are to 1) provide an overview of current ML prediction models in orthopaedic trauma; 2) evaluate the completeness of reporting following the Transparent Reporting of a multivariable prediction model for Individual Prognosis Or Diagnosis (TRIPOD) statement; and 3) assess the risk of bias following the Prediction model Risk Of Bias Assessment Tool (PROBAST) tool. Methods. A systematic search screening 3,252 studies identified 45 ML-based prediction models in orthopaedic trauma up to January 2023. The TRIPOD statement assessed transparent reporting and the PROBAST tool the risk of bias. Results. A total of 40 studies reported on training and internal validation; four studies performed both development and external validation, and one study performed only external validation. The most commonly reported outcomes were mortality (33%, 15/45) and length of hospital stay (9%, 4/45), and the majority of prediction models were developed in the hip fracture population (60%, 27/45). The overall median completeness for the TRIPOD statement was 62% (interquartile range 30 to 81%). The overall risk of bias in the PROBAST tool was low in 24% (11/45), high in 69% (31/45), and unclear in 7% (3/45) of the studies. High risk of bias was mainly due to analysis domain concerns including small datasets with low number of outcomes, complete-case analysis in case of missing data, and no reporting of performance measures. Conclusion. The results of this study showed that despite a myriad of potential clinically useful applications, a substantial part of ML studies in orthopaedic trauma lack transparent reporting, and are at high risk of bias. These problems must be resolved by following established guidelines to instil confidence in ML models among patients and clinicians. Otherwise, there will remain a sizeable
Aims. Cementless acetabular components rely on press-fit fixation for initial stability. In certain cases, initial stability is more difficult to obtain (such as during revision). No current study evaluates how a surgeon’s impaction technique (mallet mass, mallet velocity, and number of strikes) may affect component fixation. This study seeks to answer the following research questions: 1) how does impaction technique affect a) bone strain generation and deterioration (and hence implant stability) and b) seating in different density bones?; and 2) can an impaction technique be recommended to minimize risk of implant loosening while ensuring seating of the acetabular component?. Methods. A custom drop tower was used to simulate surgical strikes seating acetabular components into synthetic bone. Strike velocity and drop mass were varied. Synthetic bone strain was measured using strain gauges and stability was assessed via push-out tests. Polar