Advertisement for orthosearch.org.uk
Results 21 - 40 of 503
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 36 - 42
1 Jun 2020
Nishitani K Kuriyama S Nakamura S Umatani N Ito H Matsuda S

Aims. This study aimed to evaluate the association between the sagittal alignment of the femoral component in total knee arthroplasty (TKA) and new Knee Society Score (2011KSS), under the hypothesis that outliers such as the excessive extended or flexed femoral component were related to worse clinical outcomes. Methods. A group of 156 knees (134 F:22 M) in 133 patients with a mean age 75.8 years (SD 6.4) who underwent TKA with the cruciate-substituting Bi-Surface Knee prosthesis were retrospectively enrolled. On lateral radiographs, γ angle (the angle between the distal femoral axis and the line perpendicular to the distal rear surface of the femoral component) was measured, and the patients were divided into four groups according to the γ angle. The 2011KSSs among groups were compared using the Kruskal-Wallis test. A secondary regression analysis was used to investigate the association between the 2011KSS and γ angle. Results. According to the mean and SD of γ angle (γ, 4.0 SD 3.0°), four groups (Extended or minor flexed group, −0.5° ≤ γ < 2.5° (n = 54)), Mild flexed group (2.5° ≤ γ < 5.5° (n = 63)), Moderate flexed group (5.5° ≤ γ < 8.5° (n = 26)), and Excessive flexed group (8.5° ≤ γ (n = 13)) were defined. The Excessive flexed group showed worse 2011KSSs in all subdomains (Symptoms, Satisfaction, Expectations, and Functional activities) than the Mild flexed group. Secondary regression showed a convex upward function, and the scores were highest at γ = 3.0°, 4.0°, and 3.0° in Satisfaction, Expectations, and Functional activities, respectively. Conclusion. The groups with a sagittal alignment of the femoral component > 8.5° showed inferior clinical outcomes in 2011KSSs. Secondary regression analyses showed that mild flexion of the femoral component was associated with the highest score. When implanting the Bi-Surface Knee prosthesis surgeons should pay careful attention to avoiding flexing the femoral component extensively during TKA. Our findings may be applicable to other implant designs. Cite this article: Bone Joint J 2020;102-B(6 Supple A):36–42


The Bone & Joint Journal
Vol. 104-B, Issue 8 | Pages 963 - 971
1 Aug 2022
Sun Z Liu W Liu H Li J Hu Y Tu B Wang W Fan C

Aims. Heterotopic ossification (HO) is a common complication after elbow trauma and can cause severe upper limb disability. Although multiple prognostic factors have been reported to be associated with the development of post-traumatic HO, no model has yet been able to combine these predictors more succinctly to convey prognostic information and medical measures to patients. Therefore, this study aimed to identify prognostic factors leading to the formation of HO after surgery for elbow trauma, and to establish and validate a nomogram to predict the probability of HO formation in such particular injuries. Methods. This multicentre case-control study comprised 200 patients with post-traumatic elbow HO and 229 patients who had elbow trauma but without HO formation between July 2019 and December 2020. Features possibly associated with HO formation were obtained. The least absolute shrinkage and selection operator regression model was used to optimize feature selection. Multivariable logistic regression analysis was applied to build the new nomogram: the Shanghai post-Traumatic Elbow Heterotopic Ossification Prediction model (STEHOP). STEHOP was validated by concordance index (C-index) and calibration plot. Internal validation was conducted using bootstrapping validation. Results. Male sex, obesity, open wound, dislocations, late definitive surgical treatment, and lack of use of non-steroidal anti-inflammatory drugs were identified as adverse predictors and incorporated to construct the STEHOP model. It displayed good discrimination with a C-index of 0.80 (95% confidence interval 0.75 to 0.84). A high C-index value of 0.77 could still be reached in the internal validation. The calibration plot showed good agreement between nomogram prediction and observed outcomes. Conclusion. The newly developed STEHOP model is a valid and convenient instrument to predict HO formation after surgery for elbow trauma. It could assist clinicians in counselling patients regarding treatment expectations and therapeutic choices. Cite this article: Bone Joint J 2022;104-B(8):963–971


The Bone & Joint Journal
Vol. 104-B, Issue 4 | Pages 486 - 494
4 Apr 2022
Liu W Sun Z Xiong H Liu J Lu J Cai B Wang W Fan C

Aims. The aim of this study was to develop and internally validate a prognostic nomogram to predict the probability of gaining a functional range of motion (ROM ≥ 120°) after open arthrolysis of the elbow in patients with post-traumatic stiffness of the elbow. Methods. We developed the Shanghai Prediction Model for Elbow Stiffness Surgical Outcome (SPESSO) based on a dataset of 551 patients who underwent open arthrolysis of the elbow in four institutions. Demographic and clinical characteristics were collected from medical records. The least absolute shrinkage and selection operator regression model was used to optimize the selection of relevant features. Multivariable logistic regression analysis was used to build the SPESSO. Its prediction performance was evaluated using the concordance index (C-index) and a calibration graph. Internal validation was conducted using bootstrapping validation. Results. BMI, the duration of stiffness, the preoperative ROM, the preoperative intensity of pain, and grade of post-traumatic osteoarthritis of the elbow were identified as predictors of outcome and incorporated to construct the nomogram. SPESSO displayed good discrimination with a C-index of 0.73 (95% confidence interval 0.64 to 0.81). A high C-index value of 0.70 could still be reached in the interval validation. The calibration graph showed good agreement between the nomogram prediction and the outcome. Conclusion. The newly developed SPESSO is a valid and convenient model which can be used to predict the outcome of open arthrolysis of the elbow. It could assist clinicians in counselling patients regarding the choice and expectations of treatment. Cite this article: Bone Joint J 2022;104-B(4):486–494


Bone & Joint Open
Vol. 4, Issue 3 | Pages 129 - 137
1 Mar 2023
Patel A Edwards TC Jones G Liddle AD Cobb J Garner A

Aims. The metabolic equivalent of task (MET) score examines patient performance in relation to energy expenditure before and after knee arthroplasty. This study assesses its use in a knee arthroplasty population in comparison with the widely used Oxford Knee Score (OKS) and EuroQol five-dimension index (EQ-5D), which are reported to be limited by ceiling effects. Methods. A total of 116 patients with OKS, EQ-5D, and MET scores before, and at least six months following, unilateral primary knee arthroplasty were identified from a database. Procedures were performed by a single surgeon between 2014 and 2019 consecutively. Scores were analyzed for normality, skewness, kurtosis, and the presence of ceiling/floor effects. Concurrent validity between the MET score, OKS, and EQ-5D was assessed using Spearman’s rank. Results. Postoperatively the OKS and EQ-5D demonstrated negative skews in distribution, with high kurtosis at six months and one year. The OKS demonstrated a ceiling effect at one year (15.7%) postoperatively. The EQ-5D demonstrated a ceiling effect at six months (30.2%) and one year (39.8%) postoperatively. The MET score did not demonstrate a skewed distribution or ceiling effect either at six months or one year postoperatively. Weak-moderate correlations were noted between the MET score and conventional scores at six months and one year postoperatively. Conclusion. In contrast to the OKS and EQ-5D, the MET score was normally distributed postoperatively with no ceiling effect. It is worth consideration as an arthroplasty outcome measure, particularly for patients with high expectations. Cite this article: Bone Jt Open 2023;4(3):129–137


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 735 - 743
1 Jul 2024
Gelfer Y Cavanagh SE Bridgens A Ashby E Bouchard M Leo DG Eastwood DM

Aims. There is a lack of high-quality research investigating outcomes of Ponseti-treated idiopathic clubfeet and correlation with relapse. This study assessed clinical and quality of life (QoL) outcomes using a standardized core outcome set (COS), comparing children with and without relapse. Methods. A total of 11 international centres participated in this institutional review board-approved observational study. Data including demographics, information regarding presentation, treatment, and details of subsequent relapse and management were collected between 1 June 2022 and 30 June 2023 from consecutive clinic patients who had a minimum five-year follow-up. The clubfoot COS incorporating 31 parameters was used. A regression model assessed relationships between baseline variables and outcomes (clinical/QoL). Results. Overall, 293 patients (432 feet) with a median age of 89 months (interquartile range 72 to 113) were included. The relapse rate was 37%, with repeated relapse in 14%. Treatment considered a standard part of the Ponseti journey (recasting, repeat tenotomy, and tibialis anterior tendon transfer) was performed in 35% of cases, with soft-tissue release and osteotomies in 5% and 2% of cases, respectively. Predictors of relapse included duration of follow-up, higher initial Pirani score, and poor Evertor muscle activity. Relapse was associated with poorer outcomes. Conclusion. This is the first multicentre study using a standardized COS following clubfoot treatment. It distinguishes patients with and without relapse in terms of clinical outcomes and QoL, with poorer outcomes in the relapse group. This tool allows comparison of treatment methods and outcomes, facilitates information sharing, and sets family expectations. Predictors of relapse encourage us to create appropriate treatment pathways to reduce relapse and improve outcome. Cite this article: Bone Joint J 2024;106-B(7):735–743


Bone & Joint Open
Vol. 4, Issue 3 | Pages 188 - 197
15 Mar 2023
Pearson NA Tutton E Gwilym SE Joeris A Grant R Keene DJ Haywood KL

Aims. To systematically review qualitative studies of patients with distal tibia or ankle fracture, and explore their experience of injury and recovery. Methods. We undertook a systematic review of qualitative studies. Five databases were searched from inception to 1 February 2022. All titles and abstracts were screened, and a subset were independently assessed. Methodological quality was appraised using the Critical Appraisal Skills Programme (CASP) checklist. The GRADE-CERQual checklist was used to assign confidence ratings. Thematic synthesis was used to analyze data with the identification of codes which were drawn together to form subthemes and then themes. Results. From 2,682 records, 15 studies were reviewed in full and four included in the review. A total of 72 patients were included across the four studies (47 female; mean age 50 years (17 to 80)). Methodological quality was high for all studies, and the GRADE-CERQual checklist provided confidence that the findings were an adequate representation of patient experience of distal tibia or ankle fracture. A central concept of ‘being the same but different’ conveyed the substantial disruption to patients’ self-identity caused by their injury. Patient experience of ‘being the same but different’ was expressed through three interrelated themes, with seven subthemes: i) being proactive where persistence, doing things differently and keeping busy prevailed; ii) living with change including symptoms, and living differently due to challenges at work and leisure; and iii) striving for normality, adapting while lacking in confidence, and feeling fearful and concerned about the future. Conclusion. Ankle injuries were disruptive, draining, and impacted on patients’ wellbeing. Substantial short- and longer-term challenges were experienced during recovery. Rehabilitation and psychosocial treatment strategies may help to ameliorate these challenges. Patients may benefit from clinicians being cognisant of patient experience when assessing, treating, and discussing expectations and outcomes with patients. Cite this article: Bone Jt Open 2023;4(3):188–197


The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 386 - 393
1 Mar 2022
Neufeld ME Liechti EF Soto F Linke P Busch S Gehrke T Citak M

Aims. The outcome of repeat septic revision after a failed one-stage exchange for periprosthetic joint infection (PJI) in total knee arthroplasty (TKA) remains unknown. The aim of this study was to report the infection-free and all-cause revision-free survival of repeat septic revision after a failed one-stage exchange, and to determine whether the Musculoskeletal Infection Society (MSIS) stage is associated with subsequent infection-related failure. Methods. We retrospectively reviewed all repeat septic revision TKAs which were undertaken after a failed one-stage exchange between 2004 and 2017. A total of 33 repeat septic revisions (29 one-stage and four two-stage) met the inclusion criteria. The mean follow-up from repeat septic revision was 68.2 months (8.0 months to 16.1 years). The proportion of patients who had a subsequent infection-related failure and all-cause revision was reported and Kaplan-Meier survival for these endpoints was determined. Patients were categorized according to the MSIS staging system, and the association with subsequent infection was analyzed. Results. At the most recent follow-up, 17 repeat septic revisions (52%) had a subsequent infection-related failure and the five-year infection-free survival was 59% (95% confidence interval (CI) 39 to 74). A total of 19 underwent a subsequent all-cause revision (58%) and the five-year all-cause revision-free survival was 47% (95% CI 28 to 64). The most common indication for the first subsequent aseptic revision was loosening. The MSIS stage of the host status (p = 0.663) and limb status (p = 1.000) were not significantly associated with subsequent infection-related failure. Conclusion. Repeat septic revision after a failed one-stage exchange TKA for PJI is associated with a high rate of subsequent infection-related failure and all-cause revision. Patients should be counselled appropriately to manage expectations. The host and limb status according to the MSIS staging system were not associated with subsequent infection-related failure. Cite this article: Bone Joint J 2022;104-B(3):386–393


Bone & Joint Open
Vol. 2, Issue 11 | Pages 909 - 920
10 Nov 2021
Smith T Clark L Khoury R Man M Hanson S Welsh A Clark A Hopewell S Pfeiffer K Logan P Crotty M Costa M Lamb SE

Aims. This study aims to assess the feasibility of conducting a pragmatic, multicentre randomized controlled trial (RCT) to test the clinical and cost-effectiveness of an informal caregiver training programme to support the recovery of people following hip fracture surgery. Methods. This will be a mixed-methods feasibility RCT, recruiting 60 patients following hip fracture surgery and their informal caregivers. Patients will be randomized to usual NHS care, versus usual NHS care plus a caregiver-patient dyad training programme (HIP HELPER). This programme will comprise of three, one-hour, one-to-one training sessions for the patient and caregiver, delivered by a nurse, physiotherapist, or occupational therapist. Training will be delivered in the hospital setting pre-patient discharge. It will include practical skills for rehabilitation such as: transfers and walking; recovery goal setting and expectations; pacing and stress management techniques; and introduction to the HIP HELPER Caregiver Workbook, which provides information on recovery, exercises, worksheets, and goal-setting plans to facilitate a ‘good’ recovery. After discharge, patients and caregivers will be supported in delivering rehabilitation through three telephone coaching sessions. Data, collected at baseline and four months post-randomization, will include: screening logs, intervention logs, fidelity checklists, quality assurance monitoring visit data, and clinical outcomes assessing quality of life, physical, emotional, adverse events, and resource use outcomes. The acceptability of the study intervention and RCT design will be explored through qualitative methods with 20 participants (patients and informal caregivers) and 12 health professionals. Discussion. A multicentre recruitment approach will provide greater external validity across population characteristics in England. The mixed-methods approach will permit in-depth examination of the intervention and trial design parameters. The findings will inform whether and how a definitive trial may be undertaken to test the effectiveness of this caregiver intervention for patients after hip fracture surgery. Cite this article: Bone Jt Open 2021;2(11):909–920


Bone & Joint Open
Vol. 5, Issue 9 | Pages 758 - 765
12 Sep 2024
Gardner J Roman ER Bhimani R Mashni SJ Whitaker JE Smith LS Swiergosz A Malkani AL

Aims. Patient dissatisfaction following primary total knee arthroplasty (TKA) with manual jig-based instruments has been reported to be as high as 30%. Robotic-assisted total knee arthroplasty (RA-TKA) has been increasingly used in an effort to improve patient outcomes, however there is a paucity of literature examining patient satisfaction after RA-TKA. This study aims to identify the incidence of patients who were not satisfied following RA-TKA and to determine factors associated with higher levels of dissatisfaction. Methods. This was a retrospective review of 674 patients who underwent primary TKA between October 2016 and September 2020 with a minimum two-year follow-up. A five-point Likert satisfaction score was used to place patients into two groups: Group A were those who were very dissatisfied, dissatisfied, or neutral (Likert score 1 to 3) and Group B were those who were satisfied or very satisfied (Likert score 4 to 5). Patient demographic data, as well as preoperative and postoperative patient-reported outcome measures, were compared between groups. Results. Overall, 45 patients (6.7%) were in Group A and 629 (93.3%) were in Group B. Group A (vs Group B) had a higher proportion of male sex (p = 0.008), preoperative chronic opioid use (p < 0.001), preoperative psychotropic medication use (p = 0.01), prior anterior cruciate ligament (ACL) reconstruction (p < 0.001), and preoperative symptomatic lumbar spine disease (p = 0.004). Group A was also younger (p = 0.023). Multivariate analysis revealed preoperative opioid use (p = 0.012), prior ACL reconstruction (p = 0.038), male sex (p = 0.006), and preoperative psychotropic medication use (p = 0.001) as independent predictive factors of patient dissatisfaction. Conclusion. The use of RA-TKA demonstrated a high rate of patient satisfaction (629 of 674, 93.3%). Demographics for patients not satisfied following RA-TKA included: male sex, chronic opioid use, chronic psychotropic medication use, and prior ACL reconstruction. Patients in these groups should be identified preoperatively and educated on realistic expectations given their comorbid conditions. Cite this article: Bone Jt Open 2024;5(9):758–765


Bone & Joint Open
Vol. 5, Issue 4 | Pages 277 - 285
8 Apr 2024
Khetan V Baxter I Hampton M Spencer A Anderson A

Aims. The mean age of patients undergoing total knee arthroplasty (TKA) has reduced with time. Younger patients have increased expectations following TKA. Aseptic loosening of the tibial component is the most common cause of failure of TKA in the UK. Interest in cementless TKA has re-emerged due to its encouraging results in the younger patient population. We review a large series of tantalum trabecular metal cementless implants in patients who are at the highest risk of revision surgery. Methods. A total of 454 consecutive patients who underwent cementless TKA between August 2004 and December 2021 were reviewed. The mean follow-up was ten years. Plain radiographs were analyzed for radiolucent lines. Patients who underwent revision TKA were recorded, and the cause for revision was determined. Data from the National Joint Registry for England, Wales, Northern Island, the Isle of Man and the States of Guernsey (NJR) were compared with our series. Results. No patients in our series had evidence of radiolucent lines on their latest radiological assessment. Only eight patients out of 454 required revision arthroplasty, and none of these revisions were indicated for aseptic loosening of the tibial baseplate. When compared to data from the NJR annual report, Kaplan-Meier estimates from our series (2.94 (95% confidence interval (CI) 1.24 to 5.87)) show a significant reduction in cumulative estimates of revision compared to all cemented (4.82 (95% CI 4.69 to 4.96)) or cementless TKA (5.65 (95% CI 5.23 to 6.10)). Our data (2.94 (95% CI 1.24 to 5.87)) also show lower cumulative revision rates compared to the most popular implant (PFC Sigma Cemented Knee implant fixation, 4.03 (95% CI 3.75 to 4.33)). The prosthesis time revision rate (PTIR) estimates for our series (2.07 (95% CI 0.95 to 3.83)) were lower than those of cemented cases (4.53 (95% CI 4.49 to 4.57)) from NJR. Conclusion. The NexGen trabecular (tantalum) cementless implant has lower revision rates in our series compared to all cemented implants and other types of cementless implants, and its use in younger patients should be encouraged. Cite this article: Bone Jt Open 2024;5(4):277–285


Bone & Joint Open
Vol. 2, Issue 6 | Pages 422 - 432
22 Jun 2021
Heath EL Ackerman IN Cashman K Lorimer M Graves SE Harris IA

Aims. This study aims to describe the pre- and postoperative self-reported health and quality of life from a national cohort of patients undergoing elective total conventional hip arthroplasty (THA) and total knee arthroplasty (TKA) in Australia. For context, these data will be compared with patient-reported outcome measures (PROMs) data from other international nation-wide registries. Methods. Between 2018 to 2020, and nested within a nationwide arthroplasty registry, preoperative and six-month postoperative PROMs were electronically collected from patients before and after elective THA and TKA. There were 5,228 THA and 8,299 TKA preoperative procedures as well as 3,215 THA and 4,982 TKA postoperative procedures available for analysis. Validated PROMs included the EuroQol five-dimension five-level questionnaire (EQ-5D-5L; range 0 to 100; scored worst-best health), Oxford Hip/Knee Scores (OHS/OKS; range 0 to 48; scored worst-best hip/knee function) and the 12-item Hip/Knee disability and Osteoarthritis Outcome Score (HOOS-12/KOOS-12; range 0 to 100; scored best-worst hip/knee health). Additional items included preoperative expectations, patient-perceived improvement, and postoperative satisfaction. Descriptive analyses were undertaken. Results. For THA and TKA patients respectively, the patient profile was 2,850 (54.5%) and 4,684 (56.4%) female, mean age 66.8 years (SD 10.6) and 67.5 (SD 8.8), and mean BMI 29.9 kg/m. 2. (SD 7.7) and 32.5 kg/m. 2. (SD 7.0). The proportion of THA and TKA patients who reported their joint as ‘much better’ was 2,946 (92.6%) and 4,020 (81.6%) respectively, and the majority of patients were ‘satisfied’ or ‘very satisfied’ with their procedure (2,754 (86.5%) and 3,981 (80.8%)). There were 311 (9.7%) of THA patients and 516 (10.5%) of TKA patients who reported ‘dissatisfied’ or ‘very dissatisfied’ with their surgery. Conclusion. Large improvements in pain, function, and overall health were evident following primary THA and TKA. Approximately 10% of patients reported dissatisfaction with their surgery. Future analyses will focus on factors contributing to dissatisfaction after arthroplasty. Cite this article: Bone Jt Open 2021;2(6):422–432


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 964 - 970
1 May 2021
Ling DI Schneider B Ode G Lai EY Gulotta LV

Aims. To investigate the impact of the Charlson and Elixhauser comorbidity indices on patient-reported outcomes measures (PROMs) following shoulder arthroplasty. Methods. Patients undergoing total shoulder arthroplasty (TSA), reverse shoulder arthroplasty (RSA), or hemiarthroplasty (HA) from 2016 to 2018 were identified, along with the Charlson and Elixhauser comorbidities listed as their secondary diagnoses in the electronic medical records. Patients were matched to our institution’s registry to obtain their PROMs, including shoulder-specific (American Shoulder and Elbow Society (ASES) and Shoulder Activity Scale (SAS)) and general health scales (12-Item Short Form Survey (SF-12) and Patient-Reported Outcomes Measurement Information System-Pain Interference). Linear regression models adjusting for age and sex were used to evaluate the association between increasing number of comorbidities and PROM scores. A total of 1,817 shoulder arthroplasties were performed: 1,017 (56%) TSA, 726 (40%) RSA, and 74 (4%) HA. The mean age was 67 years (SD 10), and 936 (52%) of the patients were female. Results. The most common comorbidities were obesity (1,256, 69%) and hypertension (990, 55%). Patients with more comorbidities had lower ASES and SAS scores at baseline (p < 0.001). Elixhauser comorbidities continued to negatively impact ASES and SAS scores at one year (p = 0.002) and two-year follow-up (p = 0.002). Patients with more comorbidities reported greater pain interference on PROMIS at baseline (p = 0.007), but not at two years. Higher number of Charlson comorbidities were associated with lower scores on the SF-12 mental component at baseline (p < 0.001) and two years (p = 0.020). Higher number of Elixhauser comorbidities were associated with lower SF-12 physical component scores at baseline (p < 0.001) and two years (p = 0.004). Conclusion. Higher number of comorbidities was associated with lower baseline scores and worse outcomes on both shoulder-specific and general health PROMs. The presence of specific comorbidities may be used during shared decision-making to manage expectations for patients undergoing shoulder arthroplasty. Cite this article: Bone Joint J 2021;103-B(5):964–970


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 946 - 950
1 May 2021
Ashdown T Hayter E Morris JA Clough OT Little M Hardman J Anakwe RE

Aims. The results of surgery for Dupuytren’s disease can be compromised by the potential for disease recurrence and loss of function. Selecting which patients will benefit from repeat surgery, when to operate, and what procedure to undertake requires judgement and an understanding of patient expectations and functional needs. We undertook this study to investigate patient outcomes and satisfaction following repeat limited fasciectomy for recurrent Dupuytren’s disease. Methods. We prospectively identified all patients presenting with recurrence of Dupuytren’s disease who were selected for surgical treatment with repeat limited fasciectomy surgery between January 2013 and February 2015. Patients were assessed preoperatively, and again at a minimum of five years postoperatively. We identified 43 patients who were carefully selected for repeat fasciectomy involving 54 fingers. Patients with severe or aggressive disease with extensive skin involvement were not included; in our practice, these patients are instead counselled and preferentially treated with dermofasciectomy. The primary outcome measured was change in the Michigan Hand Outcomes Questionnaire (MHQ) score. Secondary outcomes were change in finger range of motion, flexion contracture, Semmes-Weinstein monofilament (SWM) values, and overall satisfaction. Results. There was a significant improvement in MHQ scores, across all domains, with a mean overall score increase of 24 points (p < 0.001). The summed flexion contracture across the metacarpophalangeal joint (MCPJ) and the proximal interphalangeal joint (PIPJ) reduced from means of 72.0° (SD 15.9°) to 5.6° (SD 6.8°) (p < 0.001). A significant increase in maximal flexion was seen at the MCPJ (p < 0.001) but not the PIPJ (p = 0.550). The mean overall satisfaction score from the visual analogue scale was 8.9 (7.9 to 10.0). Complications were uncommon although five fingers showed reduced sensibility at final follow-up. Conclusion. Our study shows that repeat limited fasciectomy for selected patients presenting with recurrence of Dupuytren’s disease can be an effective and safe treatment resulting in excellent patient-reported outcomes and levels of satisfaction. Cite this article: Bone Joint J 2021;103-B(5):946–950


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1405 - 1413
1 Aug 2021
Ogura K Fujiwara T Morris CD Boland PJ Healey JH

Aims. Rotating-hinge knee prostheses are commonly used to reconstruct the distal femur after resection of a tumour, despite the projected long-term burden of reoperation due to complications. Few studies have examined the factors that influence their failure and none, to our knowledge, have used competing risk models to do so. The purpose of this study was to determine the risk factors for failure of a rotating-hinge knee distal femoral arthroplasty using the Fine-Gray competing risk model. Methods. We retrospectively reviewed 209 consecutive patients who, between 1991 and 2016, had undergone resection of the distal femur for tumour and reconstruction using a rotating-hinge knee prosthesis. The study endpoint was failure of the prosthesis, defined as removal of the femoral component, the tibial component, or the bone-implant fixation; major revision (exchange of the femoral component, tibial component, or the bone-implant fixation); or amputation. Results. Multivariate Fine-Gray regression analyses revealed different hazards for each Henderson failure mode: percentage of femoral resection (p = 0.001) and extent of quadriceps muscle resection (p = 0.005) for overall prosthetic failure; extent of quadriceps muscle resection (p = 0.002) and fixation of femoral component (p = 0.011) for type 2 failure (aseptic loosening); age (p = 0.009) and percentage of femoral resection (p = 0.019) for type 3 failure (mechanical failure); and type of joint resection (p = 0.037) for type 4 (infection) were independent predictors. A bone stem ratio of > 2.5 reliably predicted aseptic loosening. Conclusion. We identified independent risk factors for overall and cause-specific prosthetic failure after rotating-hinge knee distal femoral arthroplasty using a competing risk Fine-Gray model. A bone stem ratio > 2.5 reliably predicts aseptic loosening. An accurate knowledge of the risks of distal femoral arthroplasty after resection for tumour assists surgical planning and managing patient expectations. Cite this article: Bone Joint J 2021;103-B(8):1405–1413


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 105 - 112
1 Jan 2021
Lynch JT Perriman DM Scarvell JM Pickering MR Galvin CR Neeman T Smith PN

Aims. Modern total knee arthroplasty (TKA) prostheses are designed to restore near normal kinematics including high flexion. Kneeling is a high flexion, kinematically demanding activity after TKA. The debate about design choice has not yet been informed by six-degrees-of-freedom in vivo kinematics. This prospective randomized clinical trial compared kneeling kinematics in three TKA designs. Methods. In total, 68 patients were randomized to either a posterior stabilized (PS-FB), cruciate-retaining (CR-FB), or rotating platform (CR-RP) design. Of these patients, 64 completed a minimum one year follow-up. Patients completed full-flexion kneeling while being imaged using single-plane fluoroscopy. Kinematics were calculated by registering the 3D implant models onto 2D-dynamic fluoroscopic images and exported for analysis. Results. CR-FB designs had significantly lower maximal flexion (mean 116° (SD 2.1°)) compared to CR-RP (123° (SD 1.6°)) and PS-FB (125° (SD 2.1°)). The PS-FB design displayed a more posteriorly positioned femur throughout flexion. Furthermore, the CR-RP femur was more externally rotated throughout kneeling. Finally, individual patient kinematics showed high degrees of variability within all designs. Conclusion. The increased maximal flexion found in the PS-FB and CR-RP designs were likely achieved in different ways. The PS-FB design uses a cam-post to hold the femur more posteriorly preventing posterior impingement. The external rotation within the CR-RP design was surprising and hasn’t previously been reported. It is likely due to the polyethylene bearing being decoupled from flexion. The findings of this study provide insights into the function of different knee arthroplasty designs in the context during deep kneeling and provide clinicians with a more kinematically informed choice for implant selection and may allow improved management of patients' functional expectations. Cite this article: Bone Joint J 2021;103-B(1):105–112


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 845 - 851
1 Jul 2020
Goh GS Liow MHL Tay YWA Chen JY Xu S Pang H Tay DK Chia S Lo N Yeo S

Aims. While patients with psychological distress have poorer short-term outcomes after total knee arthroplasty (TKA), their longer-term function is unknown. We aimed to 1) assess the influence of preoperative mental health status on long-term functional outcomes, quality of life, and patient satisfaction; and 2) analyze the change in mental health after TKA, in a cohort of patients with no history of mental health disorder, with a minimum of ten years’ follow-up. Methods. Prospectively collected data of 122 patients undergoing primary unilateral TKA in 2006 were reviewed. Patients were assessed pre- and postoperatively at two and ten years using the Knee Society Knee Score (KSKS) and Function Score (KSFS); Oxford Knee Score (OKS); and the Mental (MCS) and Physical Component Summary (PCS) which were derived from the 36-Item Short-Form Health Survey questionnaire (SF-36). Patients were stratified into those with psychological distress (MCS < 50, n = 51) and those without (MCS ≥ 50, n = 71). Multiple regression was used to control for age, sex, BMI, Charlson Comorbidity Index (CCI), and baseline scores. The rate of expectation fulfilment and satisfaction was compared between patients with low and high MCS. Results. There was no difference in the mean KSKS, KSFS, OKS, and SF-36 PCS at two years or ten years after TKA. Equal proportions of patients in each group attained the minimal clinically important difference for each score. Psychologically distressed patients had a comparable rate of satisfaction (91.8% (47/51) vs 97.1% (69/71); p = 0.193) and fulfilment of expectations (89.8% vs 97.1%; p = 0.094). The proportion of distressed patients declined from 41.8% preoperatively to 29.8% at final follow-up (p = 0.021), and their mean SF-36 MCS improved by 10.4 points (p < 0.001). Conclusion. Patients with poor mental health undergoing TKA may experience long-term improvements in function and quality of life that are comparable to those experienced by their non-distressed counterparts. These patients also achieved a similar rate of satisfaction and expectation fulfilment. Undergoing TKA was associated with improvements in mental health in distressed patients, although this effect may be due to residual confounding. Cite this article: Bone Joint J 2020;102-B(7):845–851


Bone & Joint Open
Vol. 1, Issue 6 | Pages 272 - 280
19 Jun 2020
King D Emara AK Ng MK Evans PJ Estes K Spindler KP Mroz T Patterson BM Krebs VE Pinney S Piuzzi NS Schaffer JL

Virtual encounters have experienced an exponential rise amid the current COVID-19 crisis. This abrupt change, seen in response to unprecedented medical and environmental challenges, has been forced upon the orthopaedic community. However, such changes to adopting virtual care and technology were already in the evolution forecast, albeit in an unpredictable timetable impeded by regulatory and financial barriers. This adoption is not meant to replace, but rather augment established, traditional models of care while ensuring patient/provider safety, especially during the pandemic. While our department, like those of other institutions, has performed virtual care for several years, it represented a small fraction of daily care. The pandemic required an accelerated and comprehensive approach to the new reality. Contemporary literature has already shown equivalent safety and patient satisfaction, as well as superior efficiency and reduced expenses with musculoskeletal virtual care (MSKVC) versus traditional models. Nevertheless, current literature detailing operational models of MSKVC is scarce. The current review describes our pre-pandemic MSKVC model and the shift to a MSKVC pandemic workflow that enumerates the conceptual workflow organization (patient triage, from timely care provision based on symptom acuity/severity to a continuum that includes future follow-up). Furthermore, specific setup requirements (both resource/personnel requirements such as hardware, software, and network connectivity requirements, and patient/provider characteristics respectively), and professional expectations are outlined. MSKVC has already become a pivotal element of musculoskeletal care, due to COVID-19, and these changes are confidently here to stay. Readiness to adapt and evolve will be required of individual musculoskeletal clinical teams as well as organizations, as established paradigms evolve. Cite this article: Bone Joint Open 2020;1-6:272–280


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 101 - 104
1 Nov 2014
Lombardi Jr AV Berend KR Adams JB

Previous studies of failure mechanisms leading to revision total knee replacement (TKR) performed between 1986 and 2000 determined that many failed early, with a disproportionate amount accounted for by infection and implant-associated factors including wear, loosening and instability. Since then, efforts have been made to improve implant performance and instruct surgeons in best practice. Recently our centre participated in a multi-centre evaluation of 844 revision TKRs from 2010 to 2011. The purpose was to report a detailed analysis of failure mechanisms over time and to see if failure modes have changed over the past 10 to 15 years. Aseptic loosening was the predominant mechanism of failure (31.2%), followed by instability (18.7%), infection (16.2%), polyethylene wear (10.0%), arthrofibrosis (6.9%) and malalignment (6.6%). The mean time to failure was 5.9 years (ten days to 31 years), 35.3% of all revisions occurred at less than two years, and 60.2% in the first five years. With improvements in implant and polyethylene manufacture, polyethylene wear is no longer a leading cause of failure. Early mechanisms of failure are primarily technical errors. In addition to improving implant longevity, industry and surgeons must work together to decrease these technical errors. All reports on failure of TKR contain patients with unexplained pain who not infrequently have unmet expectations. Surgeons must work to achieve realistic patient expectations pre-operatively, and therefore, improve patient satisfaction post-operatively. Cite this article: Bone Joint J 2014;96-B(11 Suppl A):101–4


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 9 | Pages 1253 - 1258
1 Sep 2010
Scott CEH Howie CR MacDonald D Biant LC

Up to 20% of patients are not satisfied with the outcome following total knee replacement (TKR). This study investigated the pre- and post-operative predictors of dissatisfaction in a large cohort of patients undergoing TKR. We assessed 1217 consecutive patients between 2006 and 2008 both before operation and six months after, using the Short-form (SF)-12 health questionnaire and the Oxford Knee Score. Detailed information concerning comorbidity was also gathered. Satisfaction was measured at one year when 18.6% (226 of 1217) of patients were unsure or dissatisfied with their replacement and 81.4% (911 of 1217) were satisfied or very satisfied. Multivariate regression analysis was performed to identify independent predictors of dissatisfaction. Significant (p < 0.001) predictors at one year included the pre-operative SF-12 mental component score, depression and pain in other joints, the six-month SF-12 score and poorer improvement in the pain element of the Oxford Knee Score. Patient expectations were highly correlated with satisfaction. Satisfaction following TKR is multifactorial. Managing the expectations and mental health of the patients may reduce dissatisfaction. However, the most significant predictor of dissatisfaction is a painful total knee replacement


Bone & Joint 360
Vol. 4, Issue 3 | Pages 17 - 18
1 Jun 2015

The June 2015 Wrist & Hand Roundup360 looks at: Collagenase and Dupuytren’s disease – a genuine alternative to surgery?; iPad PROMise?; Should we learn how to do endoscopic carpal tunnel release?; Two-week radiographs a relic of the past?; Bible? Aspirate or excise?; Patient expectations and trapeziometacarpal osteoarthritis; Splintage in the treatment of sagittal band incompetence and extensor tendon subluxation