Advertisement for orthosearch.org.uk
Results 21 - 39 of 39
Results per page:
The Bone & Joint Journal
Vol. 99-B, Issue 3 | Pages 383 - 392
1 Mar 2017
Handoll HH Keding A Corbacho B Brealey SD Hewitt C Rangan A

Aims

The PROximal Fracture of the Humerus Evaluation by Randomisation (PROFHER) randomised clinical trial compared the operative and non-operative treatment of adults with a displaced fracture of the proximal humerus involving the surgical neck. The aim of this study was to determine the long-term treatment effects beyond the two-year follow-up.

Patients and Methods

Of the original 250 trial participants, 176 consented to extended follow-up and were sent postal questionnaires at three, four and five years after recruitment to the trial. The Oxford Shoulder Score (OSS; the primary outcome), EuroQol 5D-3L (EQ-5D-3L), and any recent shoulder operations and fracture data were collected. Statistical and economic analyses, consistent with those of the main trial were applied.


Bone & Joint Research
Vol. 6, Issue 8 | Pages 522 - 529
1 Aug 2017
Ali AM Newman SDS Hooper PA Davies CM Cobb JP

Objectives

Unicompartmental knee arthroplasty (UKA) is a demanding procedure, with tibial component subsidence or pain from high tibial strain being potential causes of revision. The optimal position in terms of load transfer has not been documented for lateral UKA. Our aim was to determine the effect of tibial component position on proximal tibial strain.

Methods

A total of 16 composite tibias were implanted with an Oxford Domed Lateral Partial Knee implant using cutting guides to define tibial slope and resection depth. Four implant positions were assessed: standard (5° posterior slope); 10° posterior slope; 5° reverse tibial slope; and 4 mm increased tibial resection. Using an electrodynamic axial-torsional materials testing machine (Instron 5565), a compressive load of 1.5 kN was applied at 60 N/s on a meniscal bearing via a matching femoral component. Tibial strain beneath the implant was measured using a calibrated Digital Image Correlation system.


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 927 - 933
1 Jul 2017
Poltaretskyi S Chaoui J Mayya M Hamitouche C Bercik MJ Boileau P Walch G

Aims

Restoring the pre-morbid anatomy of the proximal humerus is a goal of anatomical shoulder arthroplasty, but reliance is placed on the surgeon’s experience and on anatomical estimations. The purpose of this study was to present a novel method, ‘Statistical Shape Modelling’, which accurately predicts the pre-morbid proximal humeral anatomy and calculates the 3D geometric parameters needed to restore normal anatomy in patients with severe degenerative osteoarthritis or a fracture of the proximal humerus.

Materials and Methods

From a database of 57 humeral CT scans 3D humeral reconstructions were manually created. The reconstructions were used to construct a statistical shape model (SSM), which was then tested on a second set of 52 scans. For each humerus in the second set, 3D reconstructions of four diaphyseal segments of varying lengths were created. These reconstructions were chosen to mimic severe osteoarthritis, a fracture of the surgical neck of the humerus and a proximal humeral fracture with diaphyseal extension. The SSM was then applied to the diaphyseal segments to see how well it predicted proximal morphology, using the actual proximal humeral morphology for comparison.


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 37 - 43
1 Jan 2016
Beverland DE O’Neill CKJ Rutherford M Molloy D Hill JC

Ideal placement of the acetabular component remains elusive both in terms of defining and achieving a target. Our aim is to help restore original anatomy by using the transverse acetabular ligament (TAL) to control the height, depth and version of the component. In the normal hip the TAL and labrum extend beyond the equator of the femoral head and therefore, if the definitive acetabular component is positioned such that it is cradled by and just deep to the plane of the TAL and labrum and is no more than 4mm larger than the original femoral head, the centre of the hip should be restored. If the face of the component is positioned parallel to the TAL and psoas groove the patient specific version should be restored. We still use the TAL for controlling version in the dysplastic hip because we believe that the TAL and labrum compensate for any underlying bony abnormality.

The TAL should not be used as an aid to inclination. Worldwide, > 75% of surgeons operate with the patient in the lateral decubitus position and we have shown that errors in post-operative radiographic inclination (RI) of > 50° are generally caused by errors in patient positioning. Consequently, great care needs to be taken when positioning the patient. We also recommend 35° of apparent operative inclination (AOI) during surgery, as opposed to the traditional 45°.

Cite this article: Bone Joint J 2016;98-B(1 Suppl A):37–43.


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1111 - 1117
1 Aug 2015
Chiu CK Kwan MK Chan CYW Schaefer C Hansen-Algenstaedt N

We undertook a retrospective study investigating the accuracy and safety of percutaneous pedicle screws placed under fluoroscopic guidance in the lumbosacral junction and lumbar spine. The CT scans of patients were chosen from two centres: European patients from University Medical Center Hamburg-Eppendorf, Germany, and Asian patients from the University of Malaya, Malaysia. Screw perforations were classified into grades 0, 1, 2 and 3. A total of 880 percutaneous pedicle screws from 203 patients were analysed: 614 screws from 144 European patients and 266 screws from 59 Asian patients. The mean age of the patients was 58.8 years (16 to 91) and there were 103 men and 100 women. The total rate of perforation was 9.9% (87 screws) with 7.4% grade 1, 2.0% grade 2 and 0.5% grade 3 perforations. The rate of perforation in Europeans was 10.4% and in Asians was 8.6%, with no significant difference between the two (p = 0.42). The rate of perforation was the highest in S1 (19.4%) followed by L5 (14.9%). The accuracy and safety of percutaneous pedicle screw placement are comparable to those cited in the literature for the open method of pedicle screw placement. Greater caution must be taken during the insertion of L5 and S1 percutaneous pedicle screws owing to their more angulated pedicles, the anatomical variations in their vertebral bodies and the morphology of the spinal canal at this location.

Cite this article: Bone Joint J 2015; 97-B:1111–17.


The Bone & Joint Journal
Vol. 97-B, Issue 4 | Pages 558 - 563
1 Apr 2015
Windolf M Fischer MF Popp AW Matthys R Schwieger K Gueorguiev B Hunter JB Slongo TF

End caps are intended to prevent nail migration (push-out) in elastic stable intramedullary nailing. The aim of this study was to investigate the force at failure with and without end caps, and whether different insertion angles of nails and end caps would alter that force at failure.

Simulated oblique fractures of the diaphysis were created in 15 artificial paediatric femurs. Titanium Elastic Nails with end caps were inserted at angles of 45°, 55° and 65° in five specimens for each angle to create three study groups. Biomechanical testing was performed with axial compression until failure. An identical fracture was created in four small adult cadaveric femurs harvested from two donors (both female, aged 81 and 85 years, height 149 cm and 156 cm, respectively). All femurs were tested without and subsequently with end caps inserted at 45°.

In the artificial femurs, maximum force was not significantly different between the three groups (p = 0.613). Push-out force was significantly higher in the cadaveric specimens with the use of end caps by an up to sixfold load increase (830 N, standard deviation (SD) 280 vs 150 N, SD 120, respectively; p = 0.007).

These results indicate that the nail and end cap insertion angle can be varied within 20° without altering construct stability and that the risk of elastic stable intramedullary nailing push–out can be effectively reduced by the use of end caps.

Cite this article: Bone Joint J 2015;97-B:558–63.


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1510 - 1514
1 Nov 2014
Ring J Talbot CL Clough TM

We present a review of litigation claims relating to foot and ankle surgery in the NHS in England during the 17-year period between 1995 and 2012.

A freedom of information request was made to obtain data from the NHS litigation authority (NHSLA) relating to orthopaedic claims, and the foot and ankle claims were reviewed.

During this period of time, a total of 10 273 orthopaedic claims were made, of which 1294 (12.6%) were related to the foot and ankle. 1036 were closed, which comprised of 1104 specific complaints. Analysis was performed using the complaints as the denominator. The cost of settling these claims was more than £36 million.

There were 372 complaints (33.7%) involving the ankle, of which 273 (73.4%) were related to trauma. Conditions affecting the first ray accounted for 236 (21.4%), of which 232 (98.3%) concerned elective practice. Overall, claims due to diagnostic errors accounted for 210 (19.0%) complaints, 208 (18.8%) from alleged incompetent surgery and 149 (13.5%) from alleged mismanagement.

Our findings show that the incorrect, delayed or missed diagnosis of conditions affecting the foot and ankle is a key area for improvement, especially in trauma practice.

Cite this article: Bone Joint J 2014;96-B:1510–14.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 889 - 892
1 Jul 2008
Al-Shawi A Badge R Bunker T

We have examined the accuracy of 143 consecutive ultrasound scans of patients who subsequently underwent shoulder arthroscopy for rotator-cuff disease. All the scans and subsequent surgery were performed by an orthopaedic surgeon using a portable ultrasound scanner in a one-stop clinic. There were 78 full thickness tears which we confirmed by surgery or MRI. Three moderate-size tears were assessed as partial-thickness at ultrasound scan (false negative) giving a sensitivity of 96.2%. One partially torn and two intact cuffs were over-diagnosed as small full-thickness tears by ultrasound scan (false positive) giving a specificity of 95.4%. This gave a positive predictive value of 96.2% and a negative predictive value of 95.4%. Estimation of tear size was more accurate for large and massive tears at 96.5% than for moderate (88.8%) and small tears (91.6%). These results are equivalent to those obtained by several studies undertaken by experienced radiologists.

We conclude that ultrasound imaging of the shoulder performed by a sufficiently-trained orthopaedic surgeon is a reliable time-saving practice to identify rotator-cuff integrity.


The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 436 - 441
1 Apr 2014
Twaij H Oussedik S Hoffmeyer P

The maintenance of quality and integrity in clinical and basic science research depends upon peer review. This process has stood the test of time and has evolved to meet increasing work loads, and ways of detecting fraud in the scientific community. However, in the 21st century, the emphasis on evidence-based medicine and good science has placed pressure on the ways in which the peer review system is used by most journals.

This paper reviews the peer review system and the problems it faces in the digital age, and proposes possible solutions.

Cite this article: Bone Joint J 2014;96-B:436–41.


Bone & Joint Research
Vol. 2, Issue 6 | Pages 96 - 101
1 Jun 2013
Harvie P Whitwell D

Objectives

Guidelines for the management of patients with metastatic bone disease (MBD) have been available to the orthopaedic community for more than a decade, with little improvement in service provision to this increasingly large patient group. Improvements in adjuvant and neo-adjuvant treatments have increased both the number and overall survival of patients living with MBD. As a consequence the incidence of complications of MBD presenting to surgeons has increased and is set to increase further. The British Orthopaedic Oncology Society (BOOS) are to publish more revised detailed guidelines on what represents ‘best practice’ in managing patients with MBD. This article is designed to coincide with and publicise new BOOS guidelines and once again champion the cause of patients with MBD.

Methods

A series of short cases highlight common errors frequently being made in managing patients with MBD despite the availability of guidelines.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 3 | Pages 332 - 336
1 Mar 2011
Konan S Rayan F Meermans G Witt J Haddad FS

There have been considerable recent advances in the understanding and management of femoroacetabular impingement and associated labral and chondral pathology. We have developed a classification system for acetabular chondral lesions. In our system, we use the six acetabular zones previously described by Ilizaliturri et al. The cartilage is then graded on a scale of 0 to 4 as follows: grade 0, normal articular cartilage lesions; grade 1, softening or wave sign; grade 2, cleavage lesion; grade 3, delamination; and grade 4, exposed bone. The site of the lesion is further classed as A, B or C based on whether the lesion is less than one-third of the distance from the acetabular rim to the cotyloid fossa, one-third to two-thirds of the same distance and greater than two-thirds of the distance, respectively. In order to validate the classification system, six surgeons graded ten video recordings of hip arthroscopy.

Our findings showed a high intra-observer reliability of the classification system with an intraclass correlation coefficient of 0.81 and a high interobserver reliability with an intraclass correlation coefficient of 0.88.

We have developed a simple reproducible classification system for lesions of the acetabular cartilage, which it is hoped will allow standardised documentation to be made of damage to the articular cartilage, particularly that associated with femoroacetabular impingement.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1183 - 1188
1 Sep 2011
Biau DJ Meziane M Bhumbra RS Dumaine V Babinet A Anract P

The purpose of this study was to define immediate post-operative ‘quality’ in total hip replacements and to study prospectively the occurrence of failure based on these definitions of quality. The evaluation and assessment of failure were based on ten radiological and clinical criteria. The cumulative summation (CUSUM) test was used to study 200 procedures over a one-year period. Technical criteria defined failure in 17 cases (8.5%), those related to the femoral component in nine (4.5%), the acetabular component in 32 (16%) and those relating to discharge from hospital in five (2.5%). Overall, the procedure was considered to have failed in 57 of the 200 total hip replacements (28.5%). The use of a new design of acetabular component was associated with more failures. For the CUSUM test, the level of adequate performance was set at a rate of failure of 20% and the level of inadequate performance set at a failure rate of 40%; no alarm was raised by the test, indicating that there was no evidence of inadequate performance.

The use of a continuous monitoring statistical method is useful to ensure that the quality of total hip replacement is maintained, especially as newer implants are introduced.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 4 | Pages 422 - 423
1 Apr 2008
Atrey A Leslie I Carvell J Gupte C Shepperd JAN Powell J Gibb PA

The British Orthopaedic Association has endorsed a website, www.orthoconsent.com, allowing surgeons free access to a bank of pre-written consent forms. These are designed to improve the level of information received by the patient and lessen the risk of successful litigation against surgeons and Health Trusts.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 9 | Pages 1121 - 1136
1 Sep 2006
Petrie A

Although the importance of sound statistical principles in the design and analysis of data has gained prominence in recent years, biostatistics, the application of statistics to the analysis of biological and medical data, is still a subject which is poorly understood and often mishandled. This review introduces, in the context of orthopaedic research, the terminology and the principles involved in simple data analysis, and outlines areas of medical statistics that have gained prominence in recent years. It also lists and provides an insight into some of the more common errors that occur in published orthopaedic journals and which are frequently encountered at the review stage in papers submitted to the Journal of Bone and Joint Surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1281 - 1286
1 Oct 2009
Olsen M Davis ET Chiu M Gamble P Tumia N Boyle RA Schemitsch EH

The computed neck-shaft angle and the size of the femoral component were recorded in 100 consecutive hip resurfacings using imageless computer-navigation and compared with the angle measured before operation and with actual component implanted. The reliability of the registration was further analysed using ten cadaver femora. The mean absolute difference between the measured and navigated neck-shaft angle was 16.3° (0° to 52°). Navigation underestimated the measured neck-shaft angle in 38 patients and the correct implant size in 11. Registration of the cadaver femora tended to overestimate the correct implant size and provided a low level of repeatability in computing the neck-shaft angle.

Prudent pre-operative planning is advisable for use in conjunction with imageless navigation since misleading information may be registered intraoperatively, which could lead to inappropriate sizing and positioning of the femoral component in hip resurfacing.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 9 | Pages 1121 - 1127
1 Sep 2008
Sikorski JM

The advent of computer-assisted knee replacement surgery has focused interest on the alignment of the components. However, there is confusion at times between the alignment of the limb as a whole and that of the components. The interaction between them is discussed in this article. Alignment is expressed relative to some reference axis or plane and measurements will vary depending on what is selected as the reference. The validity of different reference axes is discussed. Varying prosthetic alignment has direct implications for surrounding soft-tissue tension. In this context the interaction between alignment and soft-tissue balance is explored and the current knowledge of the relationship between alignment and outcome is summarised.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1274 - 1280
1 Oct 2009
Robinson PM Muir LT

Procedures performed at the incorrect anatomical site are commonly perceived as being relatively rare. However, they can be a devastating event for patients and doctors. Evidence from the United Kingdom and North America suggests that wrong-site, wrong-procedure and wrong-patient events occur more commonly than we think. Furthermore, their incidence may be increasing as NHS Trusts increase the volume and complexity of procedures undertaken in order to cope with increasing demands on the system. In previous studies from North America orthopaedic surgery has been found to be the worst-offending specialty.

In this paper we review the existing literature on wrong-site surgery and analyse data from the National Patient Safety Agency and NHS Litigation Authority on 292 cases of wrong-site surgery in England and Wales. Orthopaedic surgery accounted for 87 (29.8%) of these cases. In the year 2006 to 2007, the rate of wrong-site surgery in England and Wales was highest in orthopaedic surgery, in which the estimated rate was 1:105 712 cases.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 9 | Pages 1207 - 1211
1 Sep 2006
Ashford RU McCarthy SW Scolyer RA Bonar SF Karim RZ Stalley PD

The most appropriate protocol for the biopsy of musculoskeletal tumours is controversial, with some authors advocating CT-guided core biopsy. At our hospital the initial biopsies of most musculoskeletal tumours has been by operative core biopsy with evaluation by frozen section which determines whether diagnostic tissue has been obtained and, if possible, gives the definitive diagnosis. In order to determine the accuracy and cost-effectiveness of this protocol we have undertaken a retrospective audit of biopsies of musculoskeletal tumours performed over a period of two years.

A total of 104 patients had biopsies according to this regime. All gave the diagnosis apart from one minor error which did not alter the management of the patient. There was no requirement for re-biopsy. This protocol was more labour-intensive and 38% more costly than CT-guided core biopsy (AU$1804 vs AU$1308). However, the accuracy and avoidance of the anxiety associated with repeat biopsy outweighed these disadvantages.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 5 | Pages 562 - 575
1 May 2006
Boileau P Sinnerton RJ Chuinard C Walch G